Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning: Preprint

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

KCl-UCl 3 molten salts investigated by Ab Initio Molecular Dynamics (AIMD) simulations

Ab Initio Molecular Dynamics (AIMD) simulations are performed on molten KCl-UCl3 salt mixtures to determine energies, heat capacities, and densities. The density-dependent energy correction (DFT-dDsC), Grimme et al.'s DFT-D3, and Langreth & Lundqvist (vdW-cx) models are used for dispersion forces and combined with the Perdew-Burke-Ernzerhof (PBE) exchange-correlation potential with a Hubbard U parameter for the 5f electrons of uranium. After validating predictions for the end-member systems to literature data, KCl-UCl 3 mixtures are studied at select temperatures. Densities and energies both deviate from ideal solution behavior, with the maximum deviation occurring around 36% UCl 3 for mixing energies and slightly lower (29% UCl3) for densities. Compared to the NaCl-UCl 3 system, which was previously investigated using the same simulation methodologies, the KCl-UCl 3 density and mixing energy deviations from ideal solution behavior are larger by almost a factor of two. No deviation from ideal solution behavior for heat capacity was observed. The AIMD predictions for mixing energies and densities agree qualitatively with experimental data, though the spread in data obtained from the various dispersion force models utilized, measurements, and empirical estimates makes strong conclusions difficult. The dependence of thermodynamic and thermophysical properties on composition is correlated with the local chemistry of the solution phase, in particular, the tendency of UCl 3 to form network structures.

36 MATERIALS SCIENCE↗

KCl-UCl 3 molten salts investigated by Ab Initio Molecular Dynamics (AIMD) simulations: A comparative study with three dispersion models

Ab Initio Molecular Dynamics (AIMD) simulations are performed on molten KCl-UCl 3 salt mixtures to determine energies, heat capacities, and densities. The density-dependent energy correction (DFT-dDsC), Grimme et al.’s DFT-D3, and Langreth & Lundqvist (vdW-cx) models are used for dispersion forces and combined with the Perdew-Burke-Ernzerhof (PBE) exchange-correlation potential with a Hubbard U param eter for the 5$f$ electrons of uranium. After validating predictions for the end-member systems to literature data, KCl-UCl 3 mixtures are studied at select temperatures. Densities and energies both deviate from ideal solution behavior, with the maximum deviation occurring around 36% UCl 3 for mixing energies and slightly lower (29% UCl 3 ) for densities. Compared to the NaCl-UCl 3 system, which was previously investigated using the same simulation methodologies, the KCl-UCl 3 density and mixing energy deviations from ideal solution behavior are larger by almost a factor of two. No deviation from ideal solution behavior for heat capacity was observed. The AIMD predictions for mixing energies and densities agree qualitatively with experimental data, though the spread in data obtained from the various dispersion force models utilized, measurements, and empirical estimates makes strong conclusions difficult. The dependence of thermodynamic and thermophysical properties on composition is correlated with the local chemistry of the solution phase, in particular, the tendency of UCl 3 to form network structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Influence of Mesoscale Particle Structure on the Electrode Degradation and Resultant Electrochemistry of Lithium Ion Cells With Nickel Rich Lithium Nickel Manganese Cobalt Oxide Positive Electrodes

Nickel-rich lithium nickel manganese cobalt oxide, NMC (LiNi x Mn y Co z O 2 ), materials are desirable positive electrodes in lithium ion batteries, providing high capacity and energy density. The mesoscale structure of NMC materials is commonly a polycrystalline aggregate, providing opportunity for short lithium ion transport distance of the small primary particles, yet facile material handling due to the larger secondary particles. On (de)lithiation the NMC unit cell changes volume, where the anisotropic strain can result in secondary particle fracture. This secondary particle fracture process during cycling has been associated with several degradation modes of NMC materials in LIBs. In this work, a milling process was determined whereby the secondary particles could be pre-fractured with retention of the parent primary particle crystallographic structure, crystallite size, and morphology, providing the ability to unambiguously determine the influence of NMC secondary particle size and mesostructure on resultant functional behavior. The bulk and interfacial properties and electrochemistry of as-received commercially obtained polycrystal NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 , PC NMC) and its milled MPC NMC counterpart were compared. The smaller secondary particle size, higher surface area MPC NMC was found to result in 1) greater cathode tortuosity, 2) reduced surface Ni on the cycled MPC cathodes consistent with surface reconstruction, and 3) increased Ni deposition on the anodes from cathode-anode crosstalk. These factors manifested in unfavorable electrochemical behavior of MPC with lower functional capacity at both 1C and C/10 rates and higher impedance over extended moderate voltage (dis)charge cycling.

36 MATERIALS SCIENCE↗

Future material demand for automotive lithium-based batteries

The world is shifting to electric vehicles to mitigate climate change. Here, we quantify the future demand for key battery materials, considering potential electric vehicle fleet and battery chemistry developments as well as second-use and recycling of electric vehicle batteries. We find that in a lithium nickel cobalt manganese oxide dominated battery scenario, demand is estimated to increase by factors of 18–20 for lithium, 17–19 for cobalt, 28–31 for nickel, and 15–20 for most other materials from 2020 to 2050, requiring a drastic expansion of lithium, cobalt, and nickel supply chains and likely additional resource discovery. However, uncertainties are large. Key factors are the development of the electric vehicles fleet and battery capacity requirements per vehicle. If other battery chemistries were used at large scale, e.g. lithium iron phosphate or novel lithium-sulphur or lithium-air batteries, the demand for cobalt and nickel would be substantially smaller. Closed-loop recycling plays a minor, but increasingly important role for reducing primary material demand until 2050, however, advances in recycling are necessary to economically recover battery-grade materials from end-of-life batteries. Second-use of electric vehicles batteries further delays recycling potentials.

25 ENERGY STORAGE↗

SIRIUS: Science-Driven Data Management for Multi-Tiered Storage

The data sets being generated by large applications on very large-scale systems are increasing in both size and complexity. At the same time, there are new ways available to store and access these data sets. The goal in this project is to develop software that applications can use to make use of new and existing storage technologies in more sophisticated ways. One challenge in scientific data management is handling ‘hot’ vs ‘cold’ data. Data that is hot is data that is needed (or will be needed soon) in order for the program to continue progressing, while cold data is either output (and so will not be need further during the life of the program) or will not be needed until significantly later in the program’s run. Hot data should be stored in a way that allows fast access. On most systems, economic factors lead to an inverse relationship between storage performance and storage capacity and so fast access storage is limited. This makes it important to correctly place hot and cold data and avoid cold data unnecessarily consuming precious resources. In this reporting period, we addressed this challenge in various ways and at various levels. Data management frameworks offer only limited control to applications in how data is stored. We have added software capabilities for seamlessly moving data between layers of the storage technology using promote and demote functions to existing software frameworks. This gives direct control to applications in deciding what priority data receives. Additionally, we integrated different storage layer management frameworks in order to allow data to be exchanged and moved between storage layers in a consistent way across the application. Further, applications are not always able to directly decide what storage level makes sense for a given piece of data without an understanding of the underlying storage technologies. Data storage frameworks are often positioned to make these sorts of decisions in service of the application. We have added machine-learning based capabilities to data staging frameworks in order to make intelligent decisions about where data should be stored given learning about patterns in previous usage of similar data.

97 MATHEMATICS AND COMPUTING↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Normal mode description of phases of matter: Application to heat capacity

Understanding thermodynamics in liquids at the atomic level is challenging because of strong atomic interactions and lack of spatial symmetry. Recent prior theoretical works have focused on describing heat capacity of liquids in terms of phonon-like excitations but often rely on fitting factors and assumptions. In this work, we propose characterizing various phases in terms of instantaneous normal modes (INMs) of structural snapshots from molecular dynamics simulations of single-element systems over wide ranges of temperature and pressure. We use the INMs to build a mode-level microscopic description of heat capacity and demonstrate that heat capacity of liquids can be described by a combination of both solidlike and gaslike degrees of freedom, leading to a more unified framework to fundamentally describe heat capacity of all three phases of matter: solid, liquid, and gas. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Nominal Energy Storage at Existing Hydropower Reservoirs in the US

Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.

13 HYDRO ENERGY↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Application of sensitivity analysis in DYMOND/Dakota to fuel cycle transition scenarios

The ability to perform sensitivity analysis has been enabled for the nuclear fuel cycle simulator DYMOND through its coupling with the design and analysis toolkit Dakota. To test and demonstrate these new capabilities, a transition scenario and multi-parameter study were devised. The transition scenario represents a partial transition from the US nuclear fleet to a closed fuel cycle with small modular LWRs and fast reactors fueled by reprocessed used nuclear fuel. Four uncertain parameters in this transition were studied – start date of reprocessing, total reprocessing capacity, the nuclear energy demand growth, and the rate at which the fast reactors are deployed – with respect to their impact on four response metrics. The responses – total natural uranium consumed, maximum annual enrichment capacity required, total disposed mass, and total cost of the nuclear fuel cycle – were chosen based on measures known to be of interest in transition scenarios and to be significantly impacted by the varying parameters. Furthermore, analysis of this study was performed both from the direct sampling and through surrogate models developed in Dakota to calculate the global sensitivity measures Sobol’ indices. This example application of this new capability showed that the most consequential parameter to most metrics was the share of new build capacity that is fast reactors. However, for the cost metric, the scaling factor of the energy demand growth was significant and had synergistic behavior with the fast reactor new build share.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Predictive Equations for Adult Pulmonary Function in Zhejiang Province, China

Background. Accurate interpretation of lung function tests requires appropriate spirometry reference values derived from large-scale population-specific epidemiological surveys. The aim of this cross-sectional study was to establish normal spirometric values for the population of healthy, nonsmoking Han Chinese adults residing in Zhejiang province, China. Methods. We measured lung function parameters such as forced expiratory volume in 1 s, forced vital capacity, peak expiratory flow, maximal midexpiratory flow, and diffusion capacity for carbon monoxide and considered age, height, and weight as independent factors that may modify these parameters. The clinical data were divided into the study arm and validation group. The study arms were used to construct predictive equations using stepwise multiple linear regression, and data from the validation group were used to assess the robustness of the equations. Results. The 3866 participants were randomized into a study arm (n = 1,949) and a validation arm (n = 1,917). Lung function parameters had a negative association with age and a positive association with height. Data from the two groups were similar. Predictive equations were constructed from the study arm, and the validation group was used to test the feasibility of the reference equations. Conclusions. The reference values we derived can be used to evaluate lung function in this cohort in both epidemiological studies and clinical practice.

Dong, Li↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Mixing-Controlled Compression Ignition Combustion with Low-Lifecycle-CO 2 Fuels

Reducing lifecycle carbon-dioxide (CO 2 ) and toxic emissions via electrification or switching to carbon-free fuels is not currently feasible for many off-road, rail, and marine applications. This is due to factors including excessive cost, weight, or size of a battery of sufficient capacity to meet the application requirements, lack of infrastructure, insufficient time for recharging, demanding duty cycles, and severe ambient conditions. The guiding vision for the activities described herein is to enable rapid, cost-effective reductions of the environmental impacts of such applications by using improved, high efficiency engine combustion strategies with currently available and emerging low lifecycle-CO 2 fuels (LLCFs). This report summarizes progress toward achieving this vision in two project areas. The first is a Technology Commercialization Fund (TCF) project focused on facilitating the commercialization of ducted fuel injection (DFI) with LLCFs. The second is a more fundamental, Advanced Combustion Engines (ACE) research project focused on elucidating a new strategy called lean mixing-controlled combustion (LMCC) for use with emerging LLCFs.

33 ADVANCED PROPULSION SYSTEMS↗

A Framework Using Applied Process Analysis Methods to Assess Water Security in the Vu Gia–Thu Bon River Basin, Vietnam

The Vu Gia–Thu Bon (VG–TB) river basin is facing numerous challenges to water security, particularly in light of the increasing impacts of climate change. These challenges, including salinity intrusion, shifts in rainfall patterns, and reduced water supply in downstream areas, are of great concern. This study comprehensively assessed the current state of water security in the basin using robust statistical analysis methods such as the Process Analysis Method (PAM), SMART principle, and Analytic Hierarchy Process (AHP). This resulted in the development of a comprehensive assessment framework for water security in the VG–TB river basin. This framework identified five key dimensions, with basin development activities (0.32), the ability to meet water needs (0.24), and natural disaster resilience (0.19) being the most crucial and water resource potential being the least crucial (0.11) according to the AHP methodology. The latter also highlighted 15 indicators, four of which are particularly influential, including waste resources (0.54), flood (0.53), water storage capacity (0.45), and basin governance (0.42). Furthermore, 28 variables with high weight factors were identified. This framework aligns with the UN-Water water security definition and addresses the global water sustainability criteria outlined in Sustainable Development Goal 6 (SDG6). It enables the computation of a comprehensive Water Security Index (WSI) for specific regions, providing a strong foundation for decision-making and policy formulation. It aims to enhance water security in the context of climate change and support sustainable basin development, thereby guiding future research and policy decisions in water resource management.

54 ENVIRONMENTAL SCIENCES↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗