Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building design optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solid Modeling of Crew Exploration Vehicle Structure Concepts for Mass Optimization

Parametric solid and surface models of the crew exploration vehicle (CEV) command module (CM) structure concepts are developed for rapid finite element analyses, structural sizing and estimation of optimal structural mass. The effects of the structural configuration and critical design parameters on the stress distribution are visualized, examined to arrive at an efficient design. The CM structural components consisted of the outer heat shield, inner pressurized crew cabin, ring bulkhead and spars. For this study only the internal cabin pressure load case is considered. Component stress, deflection, margins of safety and mass are used as design goodness criteria. The design scenario is explored by changing the component thickness parameters and materials until an acceptable design is achieved. Aluminum alloy, titanium alloy and an advanced composite material properties are considered for the stress analysis and the results are compared as a part of lessons learned and to build up a structural component sizing knowledge base for the future CEV technology support. This independent structural analysis and the design scenario based optimization process may also facilitate better CM structural definition and rapid prototyping.

Mukhopadhyay, Vivek↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Design and Implementation of Smart Buildings: A Review of Current Research Trend

The building sector is one of the largest contributors to the world’s total energy use and greenhouse gas emissions. Advancements in building energy technologies have played a critical role in enhancing the energy sustainability of the built environment. Extensive research and new techniques in energy and environmental systems for buildings have recently emerged to address the global challenges. This study reviews existing articles in the literature, mostly since 2000, to explore technological advancement in building energy and environmental systems that can be applied to smart homes and buildings. This review study focuses on an overview of the design and implementation of energy-related smart building technologies, including energy management systems, renewable energy applications, and current advanced smart technologies for optimal function and energy-efficient performance. To review the advancement in building energy-related technologies, a systematic review process is adopted based on available published reviews and research types of articles. Review-type articles are first assessed to explore the current literature on the relevant keywords and to capture major research scopes. Research-type papers are then examined to investigate associated keywords and work scopes, including objectives, focuses, limitations, and future needs. Throughout the comprehensive literature review, this study identifies various techniques of smart home/building applications that have provided detailed solutions or guidelines in different applications to enhance the quality of people’s daily activities and the sustainability of the built environmental system. This paper shows trends in human activities and technology advancements in digital solutions with energy management systems and practical designs. Understanding the overall energy flow between a building and its environmentally connected systems is also important for future buildings and community levels. This paper assists in understanding the pathway toward future smart homes/buildings and their technologies for researchers in related research fields.

renewable system integration↗

Design of Superconducting Optoelectronic Networks for Neuromorphic Computing

We have previously proposed a novel hardware platform (SOEN) for neuromorphic computing based on superconducting optoelectronics that presents many of the features necessary for information processing in the brain. Here we discuss the design and training of networks of neurons and synapses based on this technology. We present circuit models for the simplest neurons and synapses that we can use to build networks. We discuss the further abstracted integrate and fire model that we use for evolutionary optimization of small networks of these neurons. We show that we can use the TENNLab evolutionary optimization programming framework to design small networks for logic, control and classification tasks. We plan to use the results as feedback to inform our neuron design.

Buckley, Sonia↗

A Game-Theoretic Quantum Algorithm for Solving Magic Squares

Variational quantum algorithms (VQAs) offer a promising near-term approach to finding optimal quantum strategies for playing non-local games. These games test quantum correlations beyond classical limits and enable entanglement verification. In this work, we present a variational framework for the Magic Square Game (MSG), a two-player non-local game with perfect quantum advantage. We construct a value Hamiltonian that encodes the game’s parity and consistency constraints, then optimize parameterize quantum circuits to minimize this cost. Our approach build on the stabilizer formalism, leverages commutation structure for circuit design, and is hardware-efficient. Compared to existing work, our contribution emphasizes algebraic structure an interpretability. We validate our method through numerical experiments and outline generalizations to larger games.

Chehade, Sarah [ORNL]↗

Design of Experiments, Model Calibration and Data Assimilation

This presentation provides an overview of emulation, calibration and experiment design for computer experiments. Emulation refers to building a statistical surrogate from a carefully selected and limited set of model runs to predict unsampled outputs. The standard kriging approach to emulation of complex computer models is presented. Calibration refers to the process of probabilistically constraining uncertain physics/engineering model inputs to be consistent with observed experimental data. An initial probability distribution for these parameters is updated using the experimental information. Markov chain Monte Carlo (MCMC) algorithms are often used to sample the calibrated parameter distribution. Several MCMC algorithms commonly employed in practice are presented, along with a popular diagnostic for evaluating chain behavior. Space-filling approaches to experiment design for selecting model runs to build effective emulators are discussed, including Latin Hypercube Design and extensions based on orthogonal array skeleton designs and imposed symmetry requirements. Optimization criteria that further enforce space-filling, possibly in projections of the input space, are mentioned. Designs to screen for important input variations are summarized and used for variable selection in a nuclear fuels performance application. This is followed by illustration of sequential experiment design strategies for optimization, global prediction, and rare event inference.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase 1 Development Report for the SESSA Toolkit.

The Site Exploitation System for Situational Awareness ( SESSA ) tool kit , developed by Sandia National Laboratories (SNL) , is a comprehensive de cision support system for crime scene data acquisition and Sensitive Site Exploitation (SSE). SESSA is an outgrowth of another SNL developed decision support system , the Building R estoration Operations Optimization Model (BROOM), a hardware/software solution for data acquisition, data management, and data analysis. SESSA was designed to meet forensic crime scene needs as defined by the DoD's Military Criminal Investigation Organiza tion (MCIO) . SESSA is a very comprehensive toolki t with a considerable amount of database information managed through a Microsoft SQL (Structured Query Language) database engine, a Geographical Information System (GIS) engine that provides comprehensive m apping capabilities, as well as a an intuitive Graphical User Interface (GUI) . An electronic sketch pad module is included. The system also has the ability to efficiently generate necessary forms for forensic crime scene investigations (e.g., evidence submittal, laboratory requests, and scene notes). SESSA allows the user to capture photos on site, and can read and generate ba rcode labels that limit transcription errors. SESSA runs on PC computers running Windows 7, but is optimized for touch - screen tablet computers running Windows for ease of use at crime scenes and on SSE deployments. A prototype system for 3 - dimensional (3 D) mapping and measur e ments was also developed to complement the SESSA software. The mapping system employs a visual/ depth sensor that captures data to create 3D visualizations of an interior space and to make distance measurements with centimeter - level a ccuracy. Output of this 3D Model Builder module provides a virtual 3D %22walk - through%22 of a crime scene. The 3D mapping system is much less expensive and easier to use than competitive systems. This document covers the basic installation and operation of th e SESSA tool kit in order to give the user enough information to start using the tool kit . SESSA is currently a prototype system and this documentation covers the initial release of the tool kit . Funding for SESSA was provided by the Department of Defense (D oD), Assistant Secretary of Defense for Research and Engineering (ASD(R&E)) Rapid Fielding (RF) organization. The project was managed by the Defense Forensic Science Center (DFSC) , formerly known as the U.S. Army Criminal Investigation Laboratory (USACIL) . ACKNOWLEDGEMENTS The authors wish to acknowledge the funding support for the development of the Site Exploitation System for Situational Awareness (SESSA) toolkit from the Department of Defense (DoD), Assistant Secretary of Defense for Research and Engineering (ASD(R&E)) Rapid Fielding (RF) organization. The project was managed by the Defense Forensic Science Center (DFSC) , formerly known as the U.S. Army Criminal Investigation Laboratory (USACIL). Special thanks to Mr. Garold Warner, of DFSC, who served as the Project Manager. Individuals that worked on the design, functional attributes, algorithm development, system arc hitecture, and software programming include: Robert Knowlton, Brad Melton, Robert Anderson, and Wendy Amai.

Knowlton, Robert G.↗

Monolithic Telescope-Based Star Tracker Final Report CRADA No. TC02205.0

This was a collaborative effort between LLNS as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Millennium Space Systems, Inc. ("MSS" or "Participant"), to work on a Star Tracker based on the LLNL-developed monolithic telescope ("MonoTele"). The technical objectives of this CRADA were (1) to build, launch, and characterize a Star Tracker based on an existing Model V4 monolithic telescope, and (2) to design an optimized star tracker based on a wide field of view monolithic telescope.

42 ENGINEERING↗

Advances and directions of ion nitriding/carburizing

Ion nitriding and carburizing are plasma activated thermodynamic processes for the production of case hardened surface layers not only for ferrous materials, but also for an increasing number of nonferrous metals. When the treatment variables are properly controlled, the use of nitrogenous or carbonaceous glow discharge medium offers great flexibility in tailoring surface/near-surface properties independently of the bulk properties. The ion nitriding process has reached a high level of maturity and has gained wide industrial acceptance, while the more recently introduced ion carburizing process is rapidly gaining industrial acceptance. The current status of plasma mass transfer mechanisms into the surface regarding the formation of compound and diffusion layers in ion nitriding and carbon build-up ion carburizing is reviewed. In addition, the recent developments in design and construction of advanced equipment for obtaining optimized and controlled case/core properties is summarized. Also, new developments and trends such as duplex plasma treatments and alternatives to dc diode nitriding are highlighted.

Spalvins, Talivaldis↗

BETO 2021 Peer Review - Continuous Enzymatic Hydrolysis Development (CEHD) WBS 2.4.1.101

The Continuous Enzymatic Hydrolysis Development (CEHD) project aims to reduce the cost and commercialization scale-up risks of biorefinery sugar-lignin production through development of a deployable continuous enzymatic hydrolysis (CEH) process. Through the use of external cross flow membrane filtration loops coupled to enzymatic hydrolysis (EH) reactors, pretreated biomass solids and enzymes are retained for reaction while solubilized product sugars are removed in situ, with high extents of conversion achieved through a series of reactor-membrane unit stages. The CEHD project is focused on advancing CEH as a transformational, process-intensified, lower-cost method for producing soluble clarified biomass sugars and insoluble lignin-rich streams than traditional batch enzymatic hydrolysis (BEH). The project's primary objective is to reduce the cost of CEH to be compellingly lower than conventional BEH, 10% lower in year 1 and 20% lower in year 3 (end of project). A related objective is to expand CEH's operating envelope to increase process efficiency. Through more thorough de-risking and demonstration of CEH, in conjunction with building a suite of modeling and optimization tools that allow for more facile rigorous in silico evaluation of novel CEH designs and modalities, this project intends to elevate industry interest in adopting CEH as an improvement over conventional batch processing. This project was merit reviewed in FY20. It's now in its first year of a new 3-year plan spanning FY21-FY23.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scenario Analysis of Peak Demand Savings for Commercial Buildings with Thermal Mass in California

This paper reports on the potential impact of demand response (DR) strategies in commercial buildings in California based on the Demand Response Quick Assessment Tool (DRQAT), which uses EnergyPlus simulation prototypes for office and retail buildings. The study describes the potential impact of building size, thermal mass, climate, and DR strategies on demand savings in commercial buildings. Sensitivity analyses are performed to evaluate how these factors influence the demand shift and shed during the peak period. The whole-building peak demand of a commercial building with high thermal mass in a hot climate zone can be reduced by 30percent using an optimized demand response strategy. Results are summarized for various simulation scenarios designed to help owners and managers understand the potential savings for demand response deployment. Simulated demand savings under various scenarios were compared to field-measured data in numerous climate zones, allowing calibration of the prototype models. The simulation results are compared to the peak demand data from the Commercial End-Use Survey for commercial buildings in California. On the economic side, a set of electricity rates are used to evaluate the impact of the DR strategies on economic savings for different thermal mass and climate conditions. Our comparison of recent simulation to field test results provides an understanding of the DR potential in commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BEopt-CA (Ex) -- A Tool for Optimal Integration of EE/DR/ES+PV in Existing California Homes. Cooperative Research and Development Final Report, CRADA Number CRD-11-429

Opportunities for combining energy efficiency, demand response, and energy storage with PV are often missed, because the required knowledge and expertise for these different technologies exist in separate organizations or individuals. Furthermore, there is a lack of quantitative tools to optimize energy efficiency, demand response and energy storage with PV, especially for existing buildings. Our goal is to develop a modeling tool, BEopt-CA (Ex), with capabilities to facilitate identification and implementation of a balanced integration of energy efficiency (EE), demand response (DR), and energy storage (ES) with photovoltaics (PV) within the residential retrofit market. To achieve this goal, we will adapt and extend an existing tool -- BEopt -- that is designed to identify optimal combinations of efficiency and PV in new home designs. In addition, we will develop multifamily residential modeling capabilities for use in California, to facilitate integration of distributed solar power into the grid in order to maximize its value to California ratepayers. The project is follow-on research that leverages previous California Solar Initiative RD&D investment in the BEopt software. BEopt facilitates finding the least cost combination of energy efficiency and renewables to support integrated DSM (iDSM) and Zero Net Energy (ZNE) in California residential buildings. However, BEopt is currently focused on modeling single-family houses and does not include satisfactory capabilities for modeling multifamily homes. The project brings BEopt's existing modeling and optimization capabilities to multifamily buildings, including duplexes, triplexes, townhouses, flats, and low-rise apartment buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning for Advanced Building Construction: Preprint

High-efficiency retrofits can play a key role in reducing carbon emissions associated with buildings if processes can be scaled-up to reduce cost, time, and disruption. Here we demonstrate an artificial intelligence/computer vision (AI/CV)- enabled framework for converting exterior build scans and dimensional data directly into manufacturing and installation specifications for overclad panels. In our workflow point clouds associated with LiDAR-scanned buildings are segmented into a facade feature space, vectorized features are extracted using an iterative random-sampling consensus algorithm, and from this representation an optimal panel design plan satisfying manufacturing constraints is generated. This system and the corresponding construction process is demonstrated on a test facade structure constructed at the National Renewable Energy Laboratory (NREL). We also include a brief summary of a techno-economic study designed to estimate the potential energy and cost impact of this new system.

building retrofits↗

Machine Learning for Advanced Building Construction

High-efficiency retrofits can play a key role in reducing carbon emissions associated with buildings if processes can be scaled-up to reduce cost, time, and disruption. Here we demonstrate an artificial intelligence/computer vision (AI/CV)-enabled framework for converting exterior build scans and dimensional data directly into manufacturing and installation specifications for overclad panels. In our workflow point clouds associated with LiDAR-scanned buildings are segmented into a facade feature space, vectorized features are extracted using an iterative random-sampling consensus algorithm, and from this representation an optimal panel design plan satisfying manufacturing constraints is generated. This system and the corresponding construction process is demonstrated on a test facade structure constructed at the National Renewable Energy Laboratory (NREL). We also include a brief summary of a techno-economic study designed to estimate the potential energy and cost impact of this new system.

build scans↗

Field Investigation of an Air-Source Cold Climate Heat Pump

In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.

Cold Climate Heat Pump↗