Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “authorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Resource management based on physical authentication and authorization

Systems and methods are disclosed that provide for management of resources of one or more systems included in an access-controlled area of a distributed site of an electric power delivery system. In certain embodiments, one or more users entering and access-controlled area may be identified via physical access control credentials provided to an associated access control system. A determination may be made as to whether the users have access rights to one or more hardware and/or software resources of systems included in the access-controlled area. Based on the determination, control signals may be generated by the access control system to enable and/or disable associated resources.

Gammel, Dennis↗

Designing Flexibility into the Authorized Radioactive Contents of the 9982 Shipping Package

The 9982 radioactive material shipping package, or the 9982, differs from the others by allowing a multitude of radionuclides instead of a single defined set. While allowing flexibility, this requires more justification on why these contents would be worthwhile and why they would not cause various safety hazards when shipped together. The latter was covered through mass limit calculations, and the potential uses for the package are shown through comparison with historical shipments. Here, the mass limits were already calculated[1] and used to show three example shipments are suitable for the 9982 as well. Plutonium stored in 3013 containers[2], training sources shipped in 9977 packages[3], and americium standards shipped in 9978 packages[4] were all analyzed. The mass of each radionuclide and the corresponding mass limit were used to first determine if the listed content could be shipped. If so, the maximum allowed mass of such contents is also calculated in order to see if the 200-gram fissile limit for the 9982 would be violated if additional material was packed. The sum-of-the-fractions method produces contents that do not violate the mass limits or exceed the 200-gram fissile limit. These sets also serve as realistic examples of what may be shipped in the 9982. Well-founded example contents will help the approval of the package by showing its compatibility with previously shipped material. Unfounded hypothetical contents would not show the usefulness of having a wide variety of allowed radionuclides. More contents may be developed in order to incorporate other radionuclides that were not present in these three examples. The light elements will also need to be evaluated due to their exclusion currently preventing some materials from being allowed in the 9982.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

01-16 DOE Authorization Strategy

DOE-STD-1189-2016 Process Standard – Stage Gates Establishment of Regulatory Requirements Clarity of Path Forward Integration of Safety and Design Reduce Project Risk by Establishing Regulatory Certainty through formal regulatory approvals. Flexibility in risk analysis and presentation methods. ANSI/ANS 15.21, DOE-STD-3009, LMP/TICAP

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters

Purpose: The aim of dual isotope positron emission tomography (DIPET) is to create two separate images of two coinjected PET radiotracers. DIPET shortens the duration of the study, reduces patient discomfort, and produces perfectly coregistered images compared to the case when two radiotracers would be imaged independently (sequential PET studies). Reconstruction of data from such simultaneous acquisition of two PET radiotracers is difficult because positron decay of any isotope creates only 511 keV photons; therefore, the isotopes cannot be differentiated based on the detected energy. Methods: Recently, the authors have proposed a DIPET technique that uses a combination of radiotracer A which is a pure positron emitter (such as{sup 18}F or {sup 11}C) and radiotracer B in which positron decay is accompanied by the emission of a high-energy (HE) prompt gamma (such as {sup 38}K or {sup 60}Cu). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons allow the authors to identify the lines-of-response (LORs) of isotope B. These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm. In this work the authors propose a new version of the DIPET EM-based reconstruction algorithm that allows the authors to include an additional, independent estimate of radiotracer A distribution which may be obtained if radioisotopes are administered using a staggered injections method. In this work the method is tested on simple simulations of static PET acquisitions. Results: The authors’ experiments performed using Monte-Carlo simulations with static acquisitions demonstrate that the combined method provides better results (crosstalk errors decrease by up to 50%) than the positron-gamma DIPET method or staggered injections alone. Conclusions: The authors demonstrate that the authors’ new EM algorithm which combines information from triple coincidences with prompt gammas and staggered injections improves the accuracy of DIPET reconstructions for static acquisitions so they reach almost the benchmark level calculated for perfectly separated tracers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed algorithm is effective for lung lobe segmentation in absence of auxiliary structures such as vessels and airways. The most challenging cases are those with mostly incomplete, absent, or near-absent fissures and in cases with poorly revealed fissures due to high image noise. However, the authors observe good performance even in the majority of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0.92 for FGT% and r = 0.93 for |FGT|, and the automated segmentation is not statistically significantly different (p = 0.46 for FGT% and p = 0.55 for |FGT|). The bilateral correlation between left breasts and right breasts for the FGT% is 0.94, 0.92, and 0.95 for reader 1, reader 2, and the FCM-Atlas, respectively; likewise, for the |FGT|, it is 0.92, 0.92, and 0.93, respectively. For the spatial segmentation agreement, the automated algorithm achieves a DSC of 0.69 ± 0.1 when compared to reader 1 and 0.61 ± 0.1 for reader 2, respectively, while the DSC between the two readers’ manual segmentation is 0.67 ± 0.15. Additional robustness analysis shows that the segmentation performance of the authors' method is stable both with respect to selecting different cases and to varying the number of cases needed to construct the prior probability atlas. The authors' results also show that the proposed FCM-Atlas method outperforms the commonly used two-cluster FCM-alone method. The authors' method runs at ∼5 min for each 3D bilateral MR scan (56 slices) for computing the FGT% and |FGT|, compared to ∼55 min needed for manual segmentation for the same purpose. Conclusions: The authors' method achieves robust segmentation and can serve as an efficient tool for processing large clinical datasets for quantifying the fibroglandular tissue content in breast MRI. It holds a great potential to support clinical applications in the future including breast cancer risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resolution enhancement of lung 4D-CT via group-sparsity

Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as quantitatively, the ability of their approach to achieve more accurate and better localized results over bicubic interpolation as well as a related state-of-the-art approach. The authors also show results on some datasets with tumor, to further emphasize the clinical importance of their method.Conclusions: The authors have proposed to improve the superior-inferior resolution of 4D-CT by estimating intermediate slices. The authors’ approach exploits neighboring constraints in the group-sparsity framework, toward the goal of achieving better localization and noise robustness. The authors’ results are encouraging, and positively demonstrate the role of group-sparsity for 4D-CT resolution enhancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the New Decommissioning Regulation to the Nuclear Licensed Facilities (NLF) at Fontenay-aux-Roses's Nuclear Center (CEA)

This abstract describes the application of the new decommissioning regulation on all Nuclear Licensed Facilities (NLF is to say INB in French) at Fontenay-aux-Roses's Center (CEA/FAR). The decommissioning process has been applied in six buildings which are out of the new nuclear perimeter proposed (buildings no 7, no 40, no 94, no 39, no 52/1 and no 32) and three buildings have been reorganized (no 54, no 91 and no 53 instead of no 40 and no 94) in order to increase the space for temporary nuclear waste disposal and to reduce the internal transports of nuclear waste on the site. The advantages are the safety and radioprotection improvements and a lower operating cost. A global safety file was written in 2002 and 2003 and was sent to the French Nuclear Authority on November 2003. The list of documents required is given in the paragraph I of this paper. The main goals were two ministerial decrees (one decree for each NLF) getting the authorization to modify the NLF perimeter and to carry out cleaning and dismantling activities leading to the whole decommissioning of all NLF. Some specific authorizations were necessary to carry out the dismantling program during the decommissioning procedure. They were delivered by the French Nuclear Safety Authority (FNSA) or with limited delegation by the General Executive Director (GED) on the CEA Fontenay-aux-Roses's Center, called internal authorization. Some partial dismantling or decontamination examples are given below: - evaporator for the radioactive liquid waste treatment station (building no 53): FNSA authorization: phase realised in 2002/2003. - disposal tanks for the radioactive liquid waste treatment station (building no 53) FNSA authorization: phase realised in 2004, - incinerator for the radioactive solid waste treatment station (building no 07): FNSA authorization: operation realised in 2004, - research equipments in the building no. 54 and building no. 91: internal authorization ; realised in 2005, - sample-taking to characterize solvent contained in one tank of Petrus installation (NLF 57, building 18) for radiological and chemical analysis needed to prepare the treatment and the evacuation of these wastes : internal authorization ; realised in june 2005. It was possible to plan the whole decommissioning process on the Nuclear Licensed Facilities of Fontenay-aux-Roses's Center (CEA/FAR) taking into account the French new regulation and to plan a coherent and continue program activity for the dismantling process. For the program not to be interrupted during the administrative process (2003-2006), specific authorisations have been delivered by the French Nuclear Safety Authority or by the General Executive Director (GED) on the CEA Fontenay-aux- Roses's Center (internal authorization). The time schedule to complete the entire program is until 2017 for NLF 'Procede' (NLF no 165) and until 2018 for NLF 'Support' (NLF no 166). Since 1999, an annual press meeting has been organised by the Fontenay-aux-Roses's Center Head Executive Manager.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TH-C-204-00: Medical Physics Workshop: An Update On the Journal’s Improvement Activities and Guidance On Writing and Reviewing Papers

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗