Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “apparent size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Inverse-designed metasurfaces with facile fabrication parameters

Abstract Optical metasurfaces are planar nanostructured devices that are industrially attractive in part because they utilize high-throughput microelectronic fabrication techniques for implementation. It is therefore critical to develop design paradigms that can balance the realization of highly efficient wavefront responses together with device manufacturability. We introduce a gradient-based design framework for freeform metasurfaces in which nanoscale elements are explicitly constrained to feature basic shapes, nearly uniform feature sizes, and exceptionally low aspect ratios. In spite of the apparent uniformity of the metasurface geometric features, the devices are able to utilize nonlocal near-field optical coupling to achieve highly efficient and extreme wavefront scattering beyond conventional design methodologies. Utilizing this approach, we design facile high-numerical-aperture devices such as beam deflectors and large-area metalenses capable of diffraction-limited focusing. We anticipate that these concepts can facilitate the design and integration of metasurfaces into monolithic optical systems.

Optics↗

Quantification of arterial plaque and lumen density with MDCT

Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-{mu}{sup *}d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c{sup *}exp(-a{sup *}d{sup b}) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density {rho} (g/cm{sup 3}). This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal Growth in Gels from the Mechanisms of Crystal Growth to Control of Polymorphism: New Trends on Theoretical and Experimental Aspects

A gel can be considered to be a two-phase (liquid and solid) system, which lacks flow once it reaches a stationary state. The solid phase is usually a tridimensional polymeric mesh, while the liquid phase is usually found in three forms: contained in great cavities, retained in the capillary pores between micelles, or adsorbed on the surface of a micelle. The influence of the use of gels in crystal growth is diverse and depends on the type of gel being used. A decrease in solubility of any solute in the liquid may occur if the solvent interacts extensively with the polymeric section, hence, the nucleation in gels in these cases apparently occurs at relatively low supersaturations. However, if the pore size is small enough, there is a possibility that a higher supersaturation is needed, due to the compartmentalization of solvents. Finally, this may also represent an effect in the diffusion of substances. This review is divided into three main parts; the first evaluates the theory and practice used for the obtainment of polymorphs. The second part describes the use of gels into crystallogenesis of different substances. The last part is related to the particularities of protein crystal polymorphism, as well as modern trends in gel growth for high-resolution X-ray crystallography.

36 MATERIALS SCIENCE↗

Glass production differences for equal-diameter impact craters

A thermodynamic model of meteorite impact is used to investigate the possibility that the creation of two impact craters of the same apparent diameter may have been accompanied by dissimilar shock heating regimes. For small craters, the idea may be concisely represented by the question of which event produces more glass, a large slow meteorite or a small fast one, if the resulting craters are of the same diameter. So that the results may be most apparent, the only parameters varied in this study are meteorite size and impact velocity. Identical basaltic material is assumed for meteorite and target. For impact velocities between 10 and 70 km/sec, an available model determines the radius of a spherical meteorite which would produce a crater diameter of 20 cm.

Rehfuss, D. E.↗

Mercury and Mars - The role of ionospheric conductivity in the acceleration of magnetospheric particles

Although Mercury and Mars appear to have magnetospheres of comparable size, Mercury's magnetosphere accelerates charged particles, whereas Mars' magnetosphere apparently does not. We propose that this difference results from the fact that rapid steady-state convection, and the associated particle acceleration, cannot occur in a Martian magnetosphere because of its connection to a highly conducting ionosphere. Mercury, which has no conducting ionosphere and probably an insufficiently conducting surface, can exhibit rapid solar-wind-induced convection and hence particle acceleration in its magnetospheric tail.

Hill, T. W.↗

Radio observations of interplanetary magnetic field structures out of the ecliptic

New observations of the out-of-the ecliptic trajectories of type 3 solar radio bursts have been obtained from simultaneous direction finding measurements on two independent satellite experiments, IMP-6 with spin plane in the ecliptic, and RAE-2 with spin plane normal to the ecliptic. Burst exciter trajectories were observed which originated at the active region and then crossed the ecliptic plane at about 0.8 AU. A considerable large scale north-south component of the interplanetary magnetic field is followed by the exciters. The apparent north-south and east-west angular source sizes observed by the two spacecraft are approximately equal, and range from 25 deg at 600 KHz to 110 deg at 80 KHz.

Fitzenreiter, R. J.↗

Radio observations of interplanetary magnetic field structures out of the ecliptic

Observations of the out-of-ecliptic trajectories of type III solar radio bursts have been obtained from simultaneous direction-finding measurements in two independent satellite experiments, IMP-6 with spin plane in the ecliptic and RAE-2 with spin plane normal to the ecliptic. Burst-exciter trajectories were observed which originated at the active region and then crossed the ecliptic plane at about 0.8 AU. A considerable large-scale north-south component of the interplanetary magnetic field followed by the exciters is found. The apparent north-south and east-west angular source sizes observed by the two spacecraft are approximately equal, and range from 25 deg at 600 kHz to 110 deg at 80 kHz.

Fitzenreiter, R. J.↗

Convection effects in protein crystal growth

Protein crystals for X-ray diffraction study are usually grown resting on the bottom of a hanging drop of a saturated protein solution, with slow evaporation to the air in a small enclosed cell. The evaporation rate is controlled by hanging the drop above a reservoir of water, with its saturation vapor pressure decreased by a low concentration of a passive solute. The drop has a lower solute concentration, and its volume shrinks by evaporation until the molecular concentrations match. Protein crystals can also be grown from a seed crystal suspended or supported in the interior of a supersaturated solution. The main analysis of this report concerns this case because it is less complicated than hanging-drop growth. Convection effects have been suggested as the reason for the apparent cessation of growth at a certain rather small crystal size. It seeems that as the crystal grows, the number of dislocations increases to a point where further growth is hindered. Growth in the microgravity environment of an orbiting space vehicle has been proposed as a method for obtaining larger crystals. Experimental observations of convection effects during the growth of protein crystals have been reported.

Roberts, Glyn O.↗

Compression strength failure mechanisms in unidirectional composite laminates containing a hole

Experiments on graphite-epoxy laminated plates containing unloaded small holes show that these laminates are notch insensitive. That is, the uniaxial strength of these laminates with small holes exceeds the strength predicted by a point stress criterion using the stress concentration factor for the in-plane stress field. Laminates containing large holes exhibit notch sensitive behavior and consequently their strength is reasonably well predicted by the stress concentration effect. This hole size effect is manifested both in tension and in compression. Apparently, some mechanism must cause in-plane stress relief for laminates containing small holes. The purpose of this research was to study the influence of geometric nonlinearity on the micromechanical response of a filamentary composite material in the presence of a strain gradient caused by a discontinuity such as a hole. A mathematical model was developed at the micromechanical level to investigate this geometrically nonlinear effect.

Johnson, Eric R.↗

Examination of Short- and Long-Range Atomic Order Nanocrystalline SiC and Diamond by Powder Diffraction Methods

The real atomic structure of nanocrystals determines unique, key properties of the materials. Determination of the structure presents a challenge due to inherent limitations of standard powder diffraction techniques when applied to nanocrystals. Alternate methodology of the structural analysis of nanocrystals (several nanometers in size) based on Bragg-like scattering and called the "apparent lattice parameter" (alp) is proposed. Application of the alp methodology to examination of the core-shell model of nanocrystals will be presented. The results of application of the alp method to structural analysis of several nanopowders were complemented by those obtained by determination of the Atomic Pair Distribution Function, PDF. Based on synchrotron and neutron diffraction data measured in a large diffraction vector of up to Q = 25 Angstroms(exp -1), the surface stresses in nanocrystalline diamond and SiC were evaluated.

Palosz, B.↗

Automated Eddy Current Inspection on Space Shuttle Hardware

Over the life time of the Space Shuttle program, metal parts used for the Reusable Solid Rocket Motors (RSRMs) have been nondestructively inspected for cracks and surface breaking discontinuities using magnetic particle (steel) and penetrant methods. Although these inspections adequately screened for critical sized cracks in most regions of the hardware, it became apparent after detection of several sub-critical flaws that the processes were very dependent on operator attentiveness and training. Throughout the 1990's, eddy current inspections were added to areas that had either limited visual access or were more fracture critical. In the late 1990's. a project was initiated to upgrade NDE inspections with the overall objective of improving inspection reliability and control. An automated eddy current inspection system was installed in 2001. A figure shows one of the inspection bays with the robotic axis of the system highlighted. The system was programmed to inspect the various case, nozzle, and igniter metal components that make up an RSRM. both steel and aluminum. For the past few years, the automated inspection system has been a part of the baseline inspection process for steel components. Although the majority of the RSRM metal part inventory ts free of detectable surface flaws, a few small, sub-critical manufacturing defects have been detected with the automated system. This paper will summarize the benefits that have been realized with the current automated eddy current system, as well as the flaws that have been detected.

Hartmann, John↗

Full Inversion of Solar Relativistic Electron Events Measured by the Helios Spacecraft

The Parker Solar Probe and the incoming Solar Orbiter mission will provide measurements of solar energetic particle (SEP) events at close heliocentric distances from the Sun. Up to present, the largest data set of SEP events in the inner heliosphere are the observations by the two Helios spacecraft. Aims.We re-visit a sample of 15 solar relativistic electron events measured by the Helios mission with the goal of better characterizing the injection histories of solar energetic particles and their interplanetary transport conditions at heliocentric distances <1AU. Methods. The measurements provided by the E6 instrument on board Helios provide us with the electron directional distributionsin eight di erent sectors that we use to infer the detailed evolution of the electron pitch-angle distributions. The results of a Monte Carlo interplanetary transport model, combined with a full inversion procedure, were used to fit the observed directional intensities in the 300–800 keV nominal energy channel. Unlike previous studies, we have considered both the energy and angular responses of the detector. This method allowed us to infer the electron release time profile at the source and determine the electron interplanetary transport conditions. Results. We discuss the duration of the release time profiles and the values of the radial mean free path, and compare them with thevalues reported previously in the literature using earlier approaches. Five of the events show short injection histories (<30 min) at the Sun and ten events show long-lasting (>30 min) injections. The values of mean free path range from 0.02AU to 0.27AU.Conclusions. The inferred injection histories match with the radio and soft X-ray emissions found in literature.We find no dependence of the radial mean free path on the radial distance. In addition, we find no apparent relation between the strength of interplanetary scattering and the size of the solar particle release.

Pacheco, D.↗

Large-scale space use of large juvenile and adult smalltooth sawfish Pristis pectinata: implications for management

The smalltooth sawfish Pristis pectinata is an endangered species endemic to the Atlantic Ocean. The only known viable populations occur in the USA along both coasts of Florida and in the western Bahamas. Little is known about habitat use and movement ecology of large juvenile and adult smalltooth sawfish. Although Critical Habitat — a management designation in the USA — has been identified for small juveniles, it has yet to be identified for these life stages. Between May 2016 and April 2019, we used passive acoustic telemetry and 3 large data sharing networks of receivers to track movements of 43 large juvenile and adult smalltooth sawfish. During this study, 24 females and 19 males were implanted with transmitters with estimated 4 or 10 yr battery lives. These tagged individuals were detected off the southeastern USA on 461 receivers ranging from off the coast of Brunswick, Georgia, to the lower Florida Keys, and along the Gulf coast to Apalachee Bay, Florida. Seasonal migrations were undertaken by 58% (43% mature; 57% immature) of the tagged individuals, with the remainder being apparent residents of their tagging locations. Tagged sawfish from both size classes and of both sexes migrated, which indicates that neither sex nor length is a predictor of whether a sawfish will migrate or not. Although both coasts of Florida were used for migration, most individuals consistently used the same coast when they migrated. The areas surrounding Boca Grande, Cape Canaveral, and the lower Florida Keys were heavily visited sites that could be further evaluated as potential Critical Habitat for these life stages. Understanding the movement patterns of this Critically Endangered species is essential for creating policies to protect areas important for promoting growth of the population.

Pristis pectinata Habitat use · Acoustic monitorin↗

Mineral composition of Al-rich float rocks in Jezero crater as seen by Super-Cam

During its traverse across the Jezero crater floor and western fan, the Perseverance rover encountered > 4000 float rocks – of variable size (up to ~ 50 cm) scattered on the ground without apparent connection to the surrounding stratigraphy [1]. Analysis performed using the SuperCam instrument’s [2,3,4], Laser Induced Breakdown Spectroscopy (LIBS) revealed a high concentration of Al 2 O 3 , Cr, Ti and Ni [5], and very low of Fe, Mg, Ca and Na [5, 1]. SuperCam’s infrared reflectance spectroscopy (IRS, between 1.3 and 2.6 μm) showed the presence of Al-rich aqueous alteration minerals (characteristic absorption bands of kaolinite and Al-smectites at 1.4 and 2.2 μm) as well as some (likely Cr-) spinels, identified uthrough their broad asymmetric 2 μm band, responsible for the concavity of IR spectra. These mineral species alone do not fully account for the spectral shapes; hence, the objective is to further investigate spectral modeling to determine the most probable mineral assemblages. Here, we present the results of modeling 17 light-toned float rocks, up to Sol 924, complementary to [1].

C. Royer↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

VLBI observations of SS 433 at 3.6 and 13 centimeters

SS 433 was detected and partially resolved at 2290 MHz on baselines with fringe spacings of 1.4, 0.1, and 0.003 arcsec. It was also detected at 8420 MHz on a baseline with a fringe spacing of 0.009 arcsec. Simple models of the source, consistent with the limited data, have elongated structures greater than 0.1 arcsec in size with position angles in 1979 May that were within about 10 deg of the position angle of the apparent bulges of the supernova remnant W50. The data also imply that the source contains a core less than 0.002 arcsec in size with a brightness temperature greater than 10 to the 9th K. The bright core and aligned structures that seem to be present in SS 433 and W50 resemble the structures seen in powerful extragalactic radio sources which are many orders of magnitude larger.

Walker, R. C.↗

Unique Challenges Accompany Thick-Shell CdSe/nCdS (n > 10) Nanocrystal Synthesis

Thick-shell CdSe/nCdS (n {ge} 10) nanocrystals were recently reported that show remarkably suppressed fluorescence intermittency or 'blinking' at the single-particle level as well as slow rates of Auger decay. Unfortunately, whereas CdSe/nCdS nanocrystal synthesis is well-developed up to n {le} 6 CdS monolayers (MLs), reproducible syntheses for n {ge} 10 MLs are less understood. Known procedures sometimes result in homogeneous CdS nucleation instead of heterogeneous, epitaxial CdS nucleation on CdSe, leading to broad and multimodal particle size distributions. Critically, obtained core/shell sizes are often below those desired. This article describes synthetic conditions specific to thick-shell growth (n {ge} 10 and n {ge} 20 MLs) on both small (sub2 nm) and large (>4.5 nm) CdSe cores. We find added secondary amine and low concentration of CdSe cores and molecular precursors give desired core/shell sizes. Amine-induced, partial etching of CdSe cores results in apparent shell-thicknesses slightly beyond those desired, especially for very-thick shells (n {ge} 20 MLs). Thermal ripening and fast precursor injection lead to undesired homogeneous CdS nucleation and incomplete shell growth. Core/shells derived from small CdSe (1.9 nm) have longer PL lifetimes and more pronounced blinking at single-particle level compared with those derived from large CdSe (4.7 nm). We expect our new synthetic approach will lead to a larger throughput of these materials, increasing their availability for fundamental studies and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size effects in the magnetic properties of ε-Fe{sub 2}O{sub 3} nanoparticles

We report the results of comparative analysis of magnetic properties of the systems based on ε-Fe{sub 2}O{sub 3}, nanoparticles with different average sizes (from ∼3 to 9 nm) and dispersions. The experimental data for nanoparticles higher than 6–8 nm in size are consistent with the available data, specifically, the transition to the magnetically ordered state occurs at a temperature of ∼500 K and the anomalies of magnetic properties observed in the range of 80–150 K correspond to the magnetic transition. At the same time, Mőssbauer and ferromagnetic resonance spectroscopy data as well as the results of static magnetic measurements show that at room temperature all the investigated samples contain ε-Fe{sub 2}O{sub 3} particles that exhibit the superparamagnetic behavior. It was established that the magnetic properties of nanoparticles significantly change with a decrease in their size to ∼6 nm. According to high-resolution electron microscopy and Mőssbauer spectroscopy data, the particle structure can be attributed to the ε–modification of trivalent iron oxide; meanwhile, the temperature of the magnetic order onset in these particles is increased, the well-known magnetic transition in the range of 80–150 K does not occur, the crystallographic magnetic anisotropy constant is significantly reduced, and the surface magnetic anisotropy plays a decisive role. This is apparently due to redistribution of cations over crystallographic positions with decreasing particle size, which was established using Mössbauer spectra. As the particle size is decreased and the fraction of surface atoms is increased, the contribution of an additional magnetic subsystem formed in a shell of particles smaller than ∼4 nm becomes significant, which manifests itself in the static magnetic measurements as paramagnetic contribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗