Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

CI-MBPT line strengths and atomic probabilities for some transitions of neutral iodine

Iodine is a promising alternative to expensive xenon as a propellant for electric propulsion devices. Iodine optical spectroscopy is a valuable diagnostic tool for optimization of the iodine propellant. Recently, some measurements have been conducted with cells containing iodine plasma, and iodine atomic absorption at several wavelengths (911, 906, 206 and 1315 nm) was measured with a Ti:sapphire laser. Motivated by these experiments and future applications, here we have calculated line strengths and atomic probabilities for the transitions between different types of 5s 2 5p 5 , 5s 2 5p 4 6s, 5s 2 5p 4 6p and 5s 2 5p 4 5d states of atomic iodine, using configuration-interaction many-body perturbation theory. Since experimental transition data for atomic iodine are only available for a relatively small number of transitions, we also performed calculations for the bromine atom, to further validate our approach. We found good agreement between our theory and available experimental data for both elements in most cases. Therefore, we believe that our predicted line strengths and transition probabilities are quite reliable and will be useful for iodine spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic oxygen density determination in the effluent of the COST reference source using in situ effective lifetime measurements in the presence of a liquid interface

Abstract Spatially resolved, absolute densities of atomic oxygen are measured for several helium-based admixtures in the effluent of the COST Reference Microplasma Jet using two-photon absorption laser induced fluorescence (TALIF). Admixtures investigated include a helium-only admixture, four helium/oxygen admixtures (0.1 % , 0.5 % , 0.6 % , and 1.0 % oxygen), and a helium/water admixture (2500 ppm water), chosen to coincide with previously published characterizations of plasma-treated liquid. The atomic oxygen TALIF signal is calibrated for density using the noble gas xenon, which possesses a very similar two-photon excitation and fluorescence scheme. Measurements are conducted for the jet operating in ambient air with both an open effluent and a liquid surface present, allowing for comparison with liquid phase measurements conducted under similar conditions. The presence of a water surface does not appear to alter the background chemistry in the effluent but reduces O densities close to the liquid interface when compared to a similar distance from the nozzle in an open effluent case. This may be the result of a reduction in flow velocity caused by the liquid obstructing the gas flow. Additionally, measurements near the liquid surface revealed a region of atomic oxygen well outside of where the core of the effluent impinges on the liquid. This is likely relevant for applications as it considerably expands the surface area subject to O absorption. Critically, in situ measurements of the effective lifetimes of the laser-excited 3p 3 P J state of atomic oxygen were recorded in the effluent by employing a picosecond (ps) laser and a nanosecond (ns) ICCD. By experimentally determining the contribution from collisional quenching via the in situ effective lifetime measurements, significant improvements in the accuracy of the atomic oxygen density calibration were made, with differences of approximately 30 % from existing methods of estimating quenching rates at atmospheric pressure. Finally, spatially resolved atomic oxygen densities allow for an investigation of O formation and extinction pathways in the effluent and a comparison between admixtures.

laser diagnostics↗

Search for two neutrino double electron capture of 124 Xe and 126 Xe in the full exposure of the LUX detector

Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidence of a signal was observed, allowing us to set 90\% C.L. lower limits for the half-lives of these decays of $2.0\times10^{21}$~years for $^{124}$Xe and $1.9\times10^{21}$~years for $^{126}$Xe.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part B. safe termination of DEMO plasmas

An optimized plasma current ramp-down strategy is critical for safe and fast termination of plasma discharges in a tokamak demonstration fusion reactor (DEMO), both in planned and emergency scenarios, avoiding plasma disruptions and excessive heat loads to the first wall. Plasma stability limits and machine-specific technical requirements constrain the stable envelope through which the plasma must be navigated. Large amounts of auxiliary heating are required throughout the ramp-down phase, to avoid a radiative collapse in the presence of intrinsic tungsten and seeded xenon impurities, as quantitatively estimated in this work. As the plasma current is reduced, the current density becomes increasingly peaked, reflected by a growing value of the internal inductance $\ell$ $i3$ , resulting in reduced controllability of the vertical position of the plasma. The feasibility of different plasma current ramp-down rates is tested by applying an automated optimization framework embedding the RAPTOR core transport solver. Optimal time traces for plasma current $I$ $p$ $(t)$ and plasma elongation $κ(t)$ are proposed, to satisfy an $I$ $p$ -dependent upper limit on the plasma internal inductance, as obtained from vertical stability studies using the CREATE-NL code, as well as a constraint on the time evolution of $q$ 95 , to avoid an ideal MHD mode. A negative current density near the plasma edge is observed in our simulations, even for the most conservative $I$ $p$ ramp-down rate, indicating significant transient dynamics due to a large resistive time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of radiated-power for low aspect ratio fusion plasmas

Investigating radiated power in fusion plasmas is of utmost importance to understand the effect of undesired impurities, such as metals, in present devices, or also desired impurities, such as noble gasses, to purposefully radiate a large fraction of power in future devices. These studies are especially important for high Z impurities which will play a crucial role in future generation fusion pilot plants. In this work, we have developed a power radiation analysis module, which is used to investigate 2D distributions of impurity densities and radiated power asymmetries caused due to both plasma rotation and the cooling rate dependence on temperature profile for the cases of experimental NSTX plasmas and designed scenarios for the spherical tokamak advanced reactor (STAR), both being low aspect ratio tokamaks. Two different atomic databases have been tested during this work to study their impact on the radiated power distribution, especially for high Z impurities. Also in PRAM, self-consistent calculations of two-dimensional electron, main ion, and impurity ion densities are carried out using one-dimensional input density, temperature, and rotation profiles. In the case of NSTX, discharges with high rotation of ∼ 170 km s, measured with charge exchange recombination spectroscopy, have been investigated. Rotation-induced charge separation, leading to an electrostatic potential, is calculated iteratively to a self-consistent solution while testing high Z impurities to observe any 2D asymmetry in the core radiated power due to centrifugal forces. The STAR design, being much larger (R = 4 m), is projected to have a much lower rotation, and is shown to have low rotation-induced asymmetries, on the order of ten percent or less, between the low field and high field sides. However, another effect not due to rotation but to the dependence of impurity cooling rates on temperature can lead to radiation peaking off-axis, near the plasma edge. This effect is noticeable for argon in NSTX, for example, but can also be enhanced for certain impurities at much higher temperatures projected for STAR (T e0 ~ 32 keV), for example for undesired tungsten or possibly desired xenon.

NSTX↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double diffraction imaging of x-ray induced structural dynamics in single free nanoparticles

Abstract Because of their high photon flux, x-ray free-electron lasers (FEL) allow to resolve the structure of individual nanoparticles via coherent diffractive imaging (CDI) within a single x-ray pulse. Since the inevitable rapid destruction of the sample limits the achievable resolution, a thorough understanding of the spatiotemporal evolution of matter on the nanoscale following the irradiation is crucial. We present a technique to track x-ray induced structural changes in time and space by recording two consecutive diffraction patterns of the same single, free-flying nanoparticle, acquired separately on two large-area detectors opposite to each other, thus examining both the initial and evolved particle structure. We demonstrate the method at the extreme ultraviolet (XUV) and soft x-ray Free-electron LASer in Hamburg (FLASH), investigating xenon clusters as model systems. By splitting a single XUV pulse, two diffraction patterns from the same particle can be obtained. For focus intensities of about 2 × 10 12 W cm −2 we observe still largely intact clusters even at the longest delays of up to 650 picoseconds of the second pulse, indicating that in the highly absorbing systems the damage remains confined to one side of the cluster. Instead, in case of five times higher flux, the diffraction patterns show clear signatures of disintegration, namely increased diameters and density fluctuations in the fragmenting clusters. Future improvements to the accessible range of dynamics and time resolution of the approach are discussed.

Sauppe, M. (ORCID:0000000163123102)↗

Experimental studies on photoabsorption by endohedral fullerene ions with a focus on Xe@C 60 + confinement resonances

A brief overview on the status of experimental investigations into photoionization and fragmentation of fullerenes and endohedral fullerenes by absorption of a single short-wavelength photon is presented. The focus of this paper is on the endohedral Xe@C 60 + molecular ion in which a xenon atom is centrally encapsulated inside a C$^{+}_{60}$ fullerene cage. Confinement resonances that result from the interference of Xe photoelectron matter waves emerging from the C$^{+}_{60}$ cavity were studied by exposing Xe@C 60 + ions to synchrotron radiation of 60 to 150 eV energy which is the region of the well-known giant atomic Xe 4d excitation resonance. Photoions Xe@C n q+ (with final charge states q = 2,3,4 of the product ions and numbers of carbon atoms left in the cage) were recorded as a function of photon energy and cross sections for the individual reaction channels were determined. In addition to previous work, new final channels (q = 2; n = 60, 58 and q = 4; n = 58, 56) were observed, and thus, about 70% of the oscillator strength expected for the encapsulated Xe atom in the investigated energy range could be recovered. The present results establish the first and, so far, only conclusive experimental observation of confinement resonances in an endohedral fullerene. The data are in remarkable agreement with relativistic R-matrix calculations that accompanied the previous experimental work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First tungsten radiation studies in DIII-D’s ITER baseline demonstration discharges

Abstract ITER Baseline Scenario plasmas were studied in DIII-D using krypton and xenon gases as a proxy for the tungsten that will be present in ITER. These impurities were chosen for having the same radiative loss rate Lz as tungsten would exhibit in the hotter ITER core. Results show that the scenario with these core radiators spans the range of impurity concentration and W radiated fraction expected for ITER, and up to 50% higher values, explored at zero injected torque, as well as 1 Nm and full co-torque injection with T ∼ 3 Nm. Stationary discharges with duration >2–4 τ R are achieved with f rad ⩾ 30% leading to a reduction in confinement of ∼10%, and a comparison with real metal radiators in the same range of f rad shows that the higher Lz at the lower temperatures in these plasmas yields too pessimistic results on the survivability and performance of this scenario in ITER. Simulations of ITER power balance including W radiation show that with concentration up to three times higher than in the DIII-D plasmas the scenario can be stationary, remaining at acceptable core radiated fraction values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Dark Matter Search Results from 4.2 Tonne−Years of Exposure of the LUX-ZEPLIN (LZ) Experiment

We report results of a search for nuclear recoils induced by weakly interacting massive particle (WIMP) dark matter using the LUX-ZEPLIN (LZ) two-phase xenon time projection chamber. This analysis uses a total exposure of 4.2 ±0.1 tonne-years from 280 live days of LZ operation, of which 3.3 ± 0.1 tonne-years and 220 live days are new. A technique to actively tag background electronic recoils from 214 Pb 𝛽 decays is featured for the first time. Enhanced electron-ion recombination is observed in two-neutrino double electron capture decays of 124 Xe, representing a noteworthy new background. After removal of artificial signal-like events injected into the dataset to mitigate analyzer bias, we find no evidence for an excess over expected backgrounds. World-leading constraints are placed on spin-independent (SI) and spin-dependent WIMP-nucleon cross sections for masses ≥9 GeV/𝑐 2 . The strongest SI exclusion set is 2.2×10 −48 cm 2 at the 90% confidence level and the best SI median sensitivity achieved is 5.1 ×10 −48 cm 2 , both for a mass of 40 GeV/𝑐 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Closing the Accuracy Gap in Tandem Photovoltaic Testing: An Accessible and Efficient Spectral Tuning Method Using LED-Based Simulators for Research Laboratories and Industry

Accurate performance calibration of multijunction (MJ) solar cells is critical for advancing this technology toward large-scale terrestrial application, yet existing testing methods developed by photovoltaics calibration laboratories remain prohibitively complex and resource intensive for most research laboratories. Current approaches rely on expensive multisource simulators and/or intricate spectral tuning algorithms, limiting accessibility and hindering standardized comparisons of emerging MJ technologies such as perovskite-based tandems. This paper introduces a streamlined spectral irradiance adjustment method for light-emitting diode (LED)-based solar simulators, which are increasingly adopted in the photovoltaics community due to their versatility and cost-effectiveness. The method we present bins LED channels into groups based on the number of junctions of the MJ photovoltaic device under test (DUT) and their corresponding band gaps and incorporates an automated tuning algorithm that eliminates the need to adjust each channel’s irradiance individually. This tuning algorithm requires the relative spectral responsivities of both the DUT and a broadband reference cell, as well as a calibrated spectroradiometer. Measurement validation across various MJ devices, including III-V and perovskite/silicon tandems, demonstrates excellent agreement within 1% with well-established xenon-tungsten multisource simulators and associated tuning algorithms. By enabling precise spectral tuning with readily available equipment and a simple tuning algorithm, our approach bridges the measurement accuracy gap between research laboratories and accredited testing facilities, fostering more reliable device comparisons and accelerating the translation of MJ technologies into real-world energy systems.

14 SOLAR ENERGY↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗