Investigation of island size effect on radiation distribution during attached and detached plasmas in the island divertor of W7-X
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.
We report simultaneous control of the large edge localized modes (ELMs) and divertor heat fluxes in a metal wall environment is a critical issue for steady-state operation of a tokamak fusion reactors. Here we report a sustained ELM suppression scenario achieved in the EAST tokamak compatible with radiative divertor using different seeding impurity species over a wide range of conditions. A low-n mode appears, as manifested by the oscillations of a radiation front near the X-point. This mode appears to drive strong particle transport and tungsten exhaust, which is essential to the maintenance of the ELM-stable state. We have developed a model to explain the mode excitation, by coupling the impurity radiative condensation instability to drift waves, which could explain some characteristics of the low-n mode well. The low-n mode may offer a new ELM-stable scenario compatible with radiative divertor for future fusion reactors.
Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.
Laser heating of a gas in a cylindrical liner held in by a thin foil window is a critical process in the MagLIF (magnetized liner inertial fusion) concept. Window burn-through and gas heating for OMEGA scale MagLIF cylinders as a function of time have been determined using spectrally integrated soft x-ray diagnostics. Window laser absorption is classified in terms of the emitted x-rays from the window plasma as a function of laser energy, and shows that laser energy absorbed is weakly dependent on incident intensity. Radiation-hydrodynamic simulations overestimate the amount of laser energy absorbed by the window as evidenced by the increase in x-ray radiation across several photon energy bands compared to experiments. Gas temperatures inferred from soft x-ray emission from the front 1 mm of the liner are shown to evolve in time in a similar manner to simulation predictions. In conclusion, soft x-ray emission from the gas within the region of the liner that is normally imploded is shown to meet the 100 eV requirements set by the initial point design for laser-driven MagLIF.
We report solids irradiated by energetic photons can be eroded in two modes, depending on the radiation intensity. High average, low-peak power sources, e.g., synchrotron radiation and high-order harmonics, induce desorption of the material at a low etch rate. In contrast, high-peak-power radiation from extreme ultraviolet and x-ray lasers usually causes a massive removal of the material even by a single shot. In this contribution, an effective material erosion is reported in PMMA exposed to multiple accumulated pulses generated by the free-electron x-ray-laser Linac Coherent Light Source (LCLS, tuned at a photon energy of 830 eV in this study, operated in Menlo Park at Stanford, CA, USA) at a fluence below the single-pulse ablation threshold. The effect is caused by polymer-chain scissions initiated by single photons carrying enough energy to break the C—C bounds. High efficiency of the erosion is supposed to occur due to a correlation of the single-photon effects. The subthreshold damage exhibits a nonlinear dose dependence resulting from a competition between chain scissions and cross-linking processes. The cross-linking is proven by Raman spectroscopy of the irradiated polymer. Two theoretical models of the x-ray free-electron-laser-induced erosion are suggested, which provide an excellent agreement with the experimental results.
Modest effects of deuterium and carbon radiation opacity in the Super-X and snowflake divertor plasmas are predicted for MAST Upgrade tokamak with core plasma input power 2.5–5 MW and plasma current 1 MA. The radiation transport modeling is based on the SOLPS-EIRENE and UEDGE code divertor plasma predictions. Two radiation transport models are used: one is based on a full radiation transport equation implemented in the radiation transport and collisional-radiative code CRETIN (without feedback on the background plasma), and another is an internal self-consistent UEDGE model with ionization, recombination, and heating rates corrected for Ly α line trapping based on the escape probability model implemented in CRETIN. In MAST-U, the Super-X and snowflake divertor plasmas are predicted to reach detached regimes at lower upstream densities than the standard divertor, and the conclusion still holds with radiation transport effects included. At neutral densities m -3 , modest Ly α deuterium line trapping with optical depths 10–15 is predicted in the Super-X divertor. Divertor plasmas are optically thin to other Lyman and Balmer lines, as well as to strong C III and C IV lines that are responsible for most of divertor radiated power. Insignificant changes (within a few percent) to divertor deuterium ionization and recombination rates are found. Radiation fluxes on outer divertor target are modified within a factor of 2–3 when the radiation transport is accounted for, and a similar variation is found due to the line shape models that define the absorption and emission line profiles in the radiation transport modeling. The predicted Lyman and Balmer spectral intensities are significantly modified due to radiation trapping. A measurement of divertor radiation transport effects is discussed using the Ly β /Ba α line ratio. In the snowflake divertor configuration, divertor plasmas are found to be optically thin to Lyman series lines within a large range of parameter variations that include upstream density, divertor transport coefficients, and magnetic configurations. Finally, modest radiation transport effects are only found in a few cases with strongest divertor transport and magnetic configurations closest to the ideal snowflake configuration, however, the plasma background models that were used are yet to be validated with an experiment.
For routine radiological operations, lost radioactive sources, decommissioning and cleanup of nuclear facilities, and radiological terrorist events such as Radioactive Dispersive Devices (RDDs) or Radiological Exposure Devices (REDs), individuals are tasked with accurately locating both point and distributed sources of radiation. Radiation workers must often practice these tasks, whether part of initial training or periodically as part of formal or informal exercises or drills. In such circumstances, it is desirable to have an accurate recreation of a radioactive source, including a method of detecting it, which does not include dangerous amounts of radiation. The goal of this research was to develop a radiation simulation technology that uses IEEE 802.11x W-LAN protocol, i.e. Wi-Fi sources and detectors for these, as an inexpensive, precise and accurate method of replicating sources of gamma radiation. For this work, existing 802.11x sources were used. Software was developed for use with an Android smartphone to detect the presence of these sources. The measurements followed the expected behavior as a function of distance from the sources, mimicking that of gamma radiation, thus demonstrating the fundamental principle of operation. The ultimate system will be used in an outreach program to interest students in the radiation protection field.
Many X-ray bright active galactic nuclei (AGNs) are predicted to follow an extended stage of obscured black hole growth. In support of this picture we examine the X-ray undetected AGNs in the COSMOS field and compare their host galaxies with X-ray bright AGNs. We examine galaxies with M {sub *} > 10{sup 9.5} M {sub ⊙} for the presence of AGNs at redshifts z = 0.5–3. We select AGNs in the infrared using Spitzer and Herschel detections and use color selection techniques to select AGNs within strongly star-forming hosts. We stack Chandra X-ray data of galaxies with an infrared (IR) detection but lacking an X-ray detection to obtain soft and hard fluxes, allowing us to measure the energetics of these AGNs. We find a clear correlation between X-ray luminosity and IR AGN luminosity in the stacked galaxies. We also find that X-ray undetected AGNs all lie on the main sequence—the tight correlation between the star formation rate and M {sub *} that holds for the majority of galaxies, regardless of mass or redshift. This work demonstrates that there is a higher population of obscured AGNs than previously thought.
Understanding the speciation and local structure of metal solutes in molten salts is essential for predicting thermal properties and the redox and corrosion potentials of molten salts for next-generation nuclear reactors and concentrated solar power plant applications. Here, we employ X-ray absorption spectroscopy combined with electron paramagnetic resonance (EPR) measurements to investigate the effects of electron irradiation on 0.1 wt % NiCl 2 dissolved in molten eutectic KCl-ZnCl 2 salt. Radiation-driven reduction of Ni 2+ leading to nucleation and growth of Ni nanoparticles is studied as a function of electron dose (3–15 MGy) and temperature. Quantitative X-ray absorption near edge structure and linear combination fitting are utilized to investigate the extent of reduction as a function of the electron dose and temperature. A multiple-scattering (MS) approach is used for extended X-ray absorption fine structure analysis to deduce the size of the Ni nanoparticles formed and to understand the effect of the dose on the local structure of the nanoparticles. EPR studies on solidified NiCl 2 dissolved in molten eutectic KCl-ZnCl 2 salt show the formation of magnetic Ni nanoparticles.
Six nominally repeat neon shattered pellet injection (SPI) shutdowns of stable DIII-D Super H-modes are studied to understand the 3D properties of the radiation and impurity transport. The radiation efficiency and radiation peaking determine whether first wall melting is expected following disruption mitigation in ITER. Previous studies make use of axisymmetric approximations to infer radiation efficiencies, but validating the high efficiency required by ITER necessitates improved accuracy, and this work contributes by exploring the 3D radiation and density structures that will inform forward modeling. When the neon shatter plume produced by the SPI reaches the plasma edge, m/n = 3/1 and 2/1 island O-points are observed to align with the injection trajectory in five out of six cases, suggesting that the injected material seeds the island O-points. Field aligned neon structures emitting Ne-I line radiation drift at 1 km/s in the ion diamagnetic drift direction during the pre-TQ, tracking the motion of the m/n = 2/1 island O-point. Neon fragments penetrate to the q = 2 surface by the time of the TQ. Techniques to constrain the 3D emissivity are explored, and one method constrains a 3D flux tube that is consistent with the radiation data, and when mapped to the interferometers, intersects the lasers that measure the highest density. The resulting structure derived from the radiation measurements exists near the 2/1 island X-point. In five repeatable discharges, the peak of the radiation in the toroidal direction exists in a 120° toroidal sector where the injection occurs, in contrast with the outlier discharge where the toroidal peak exists in the complementary 240° toroidal sector far from the injector, and where a 50% lower density rise is observed. In conclusion, the n = 1 phase behavior is markedly different in the outlier discharge, suggesting a possible dependence of the radiation structure and the assimilation efficiency on MHD.
Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.
Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.
Radiation therapy plays a prominent role in breast cancer treatment, but the high doses of radiation damage both healthy and cancerous cells. Therefore, additional research is needed into combination therapies that could preferentially radiosensitize cancer cells compared to surrounding healthy tissue without causing deleterious side effects. Histone deacetylase inhibitor drugs (HDACis) have been tested as radiosensitizers in both basic research and clinical trials, but the long exposure time typically used in these treatments and the lack of matched healthy cell controls often leave aspects of their mechanism of action unclear. Here, we show that transient (2 h) trichostatin A (TSA) treatment of cancerous and non-tumorigenic breast epithelial cell lines increases immediate DNA damage and decreases long term cell viability in both cell types at high radiation doses. Transient TSA treatment also causes an increase in DNA damage signals after 5 Gy X-rays in other cancer and healthy cell types: A375 melanoma cells and BJ5-ta fibroblasts. This suggests that chromatin decompaction acts to increase cellular vulnerability to initial DNA damage from high doses of radiation in a cell type independent manner that does not rely on changes to DNA repair pathways caused by longer TSA treatment. However, responses to lower doses of radiation and long term survival are more cell type specific: only MCF7 cells experience an effect of TSA on DNA damage after 1 Gy X-ray radiation while MCF10a cells experience somewhat more evident cell viability effects of combined TSA and radiation treatment long term.
The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.
The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.
The major goal of this project was to study the atomic and radiation physics of photoionized plasmas driven by a broadband x-ray flux and its impact on plasma x-ray heating and ionization, emissivity and opacity, and radiation-hydrodynamics. This problem is relevant to the physics of accretion disks surrounding black holes, x-ray binaries, and active galactic nuclei in astrophysics. In addition, it is also important for understanding non-equilibrium laboratory plasmas driven by a distribution of photons. To this end, and motivated by previous and ongoing gas-cell experiments performed by the PI at the Z facility of Sandia National Laboratories, we developed a new experimental platform at the 1MA Zebra pulsed power accelerator of the University of Nevada, Reno based on using a gas jet produced by a supersonic nozzle. The gas jet is turned into a photoionized plasma driven by the x- ray flux from a wire-array z-pinch. Establishing this new experimental platform at Zebra was a major goal of this project. In addition, we have also dedicated effort to continue complementary experiments at the Z facility using the gas-cell photoionized plasma set up with support from the Fundamental Science Program at Z as well as to perform data processing and analysis, and theory and modeling simulations, including electron kinetics and radiation-hydrodynamics. Since we seek to test and establish what physics models are needed to describe photoionized plasma guided by experimental observation, these complementary experimental efforts were central to achieving the goals of this project.
Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.