Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIGGLER MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Statistical Analysis of Crossed Undulator for Polarization Control in a SASE FEL

There is a growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. In this paper, we study the crossed undulator scheme (K.-J. Kim, Nucl. Instrum. Methods A 445, 329 (2000)) for rapid polarization control in a self-amplified spontaneous emission (SASE) free electron laser (FEL). Because a SASE source is a temporally chaotic light, we perform a statistical analysis on the state of polarization using FEL theory and simulations. We show that by adding a small phase shifter and a short (about 1.3 times the FEL power gain length), 90{sup o} rotated planar undulator after the main SASE planar undulator, one can obtain circularly polarized light--with over 80% polarization--near the FEL saturation.

43 PARTICLE ACCELERATORS↗

Coherent optical transition radiation and self-amplified spontaneous emission generated by chicane-compressed electron beams

Observations of strongly enhanced optical transition radiation (OTR) following significant bunch compression of photoinjector beams by a chicane have been reported during the commissioning of the Linac Coherent Light Source (LCLS) accelerator and recently at the Advanced Photon Source (APS) linac. These localized transverse spatial features involve signal enhancements of nearly a factor of 10 and 100 in the APS case at the 150-MeV and 375-MeV OTR stations, respectively. They are consistent with a coherent process seeded by noise and may be evidence of a longitudinal space charge (LSC) microbunching instability which leads to coherent OTR (COTR) emissions. Additionally, we suggest that localized transverse structure in the previous self-amplified spontaneous emission (SASE) free-electron laser (FEL) data at APS in the visible-UV regime as reported at FEL02 may be attributed to such beam structure entering the FEL undulators and inducing the SASE startup at those structures. Separate beam structures 120 microns apart in x and 2.9 nm apart in wavelength were reported. The details of these observations and operational parameters will be presented.

43 PARTICLE ACCELERATORS↗

Generation of attosecond x-ray pulses with a multi-cycle two-color ESASE scheme

Generation of attosecond x-ray pulses is attracting much attention within the x-ray free-electron laser (FEL) user community. Several schemes using extremely short laser pulses to manipulate the electron bunches have been proposed. In this paper, we extend the attosecond two-color ESASE scheme proposed by Zholents et al. to the long optical cycle regime using a second detuned laser and a tapered undulator. Both lasers can be about ten-optical-cycles long, with the second laser frequency detuned from the first to optimize the contrast between the central and side current spikes. A tapered undulator mitigates the degradation effect of the longitudinal space charge (LSC) force in the undulator and suppresses the FEL gain of all side current peaks. Simulations using the LCLS parameters show a single attosecond x-ray spike of {approx} 110 attoseconds can be produced. The second laser can also be detuned to coherently control the number of the side x-ray spikes and the length of the radiation pulse.

43 PARTICLE ACCELERATORS↗

Analysis of Shot Noise Suppression for Electron Beams

Shot noise can affect the performance of free-electron lasers (FELs) by driving instabilities (e.g., the microbunching instability) or by competing with seeded density modulations. Recent papers have proposed suppressing shot noise to enhance FEL performance. In this paper we use a one-dimensional (1D) model to calculate the noise amplification from an energy modulation (e.g., electron interactions from space charge or undulator radiation) followed by a dispersive section. We show that, for a broad class of interactions, selecting the correct dispersive strength suppresses shot noise across a wide range of frequencies. The final noise level depends on the beam's energy spread and the properties of the interaction potential. We confirm and illustrate our analytical results with 1D simulations.

43 PARTICLE ACCELERATORS↗

Beam Conditioning for Free Electron Lasers:Consequences and Methods

The consequences of beam conditioning in four example cases [VISA, a soft x-ray free-electron laser (FEL), LCLS, and a 'Greenfield' FEL] are examined. It is shown that in emittance limited cases, proper conditioning reduces sensitivity to the transverse emittance and, furthermore, allows for stronger focusing in the undulator. Simulations show higher saturation power, with gain lengths reduced by a factor of 2 or more. The beam dynamics in a general conditioning system are studied, with 'matching conditions' derived for achieving conditioning without growth in the effective emittance. Various conditioning lattices are considered, and expressions derived for the amount of conditioning provided in each case when the matching conditions are satisfied. These results show that there is no fundamental obstacle to producing beam conditioning, and that the problem can be reduced to one of proper lattice design. Nevertheless, beam conditioning will not be easy to implement in practice.

43 PARTICLE ACCELERATORS↗

Ultra-small-angle x-ray scattering at the Advanced Photon Source.

The design and operation of a versatile ultra-small-angle X-ray scattering (USAXS) instrument at the Advanced Photon Source (APS) at Argonne National Laboratory are presented. The instrument is optimized for the high brilliance and low emittance of an APS undulator source. It has angular and energy resolutions of the order of 10{sup -4}, accurate and repeatable X-ray energy tunability over its operational energy range from 8 to 18 keV, and a dynamic intensity range of 10{sup 8} to 10{sup 9}, depending on the configuration. It further offers quantitative primary calibration of X-ray scattering cross sections, a scattering vector range from 0.0001 to 1 {angstrom}{sup -1}, and stability and reliability over extended running periods. Its operational configurations include one-dimensional collimated (slit-smeared) USAXS, two-dimensional collimated USAXS and USAXS imaging. A robust data reduction and data analysis package, which was developed in parallel with the instrument, is available and supported at the APS.

43 PARTICLE ACCELERATORS↗

High-pressure X-ray diffraction studies of potassium chlorate

Two static high-pressure X-ray diffraction (XRD) studies of potassium chlorate have been performed at pressures of up to {approx}14.3 GPa in a diamond anvil cell at ambient temperature using the 16 ID-B undulator beamline at the Advanced Photon Source for the X-ray source. The first experiment was conducted to ascertain decomposition rates of potassium chlorate as a function of pressure. Below 2 GPa, the sample was observed to decompose rapidly in the presence of the X-ray beam and release oxygen. Above 2 GPa (near the phase I phase II transition), the decomposition rate dramatically slowed so that good quality XRD patterns could be acquired. This suggests a phase-dependent decomposition rate. In the second study, X-ray diffraction spectra were collected at pressures from 2 to 14.3 GPa by aligning virgin portions of the sample into the focused X-ray beam at each pressure. The results suggest the co-existence of mixed monoclinic (I) and rhombohedral (II) phases of potassium chlorate near 2 GPa. At pressures beyond 4 GPa, the XRD patterns show a very good fit to KClO{sub 3} in the rhombohedral phase with space group R3m, in agreement with earlier studies. No further phase transitions were observed with pressure. Decompression of the sample to ambient pressure indicated mixed phases I and II coupled with a small amount of synchrotron X-ray-induced decomposition product. The equation of state within this pressure regime has been determined.

43 PARTICLE ACCELERATORS↗

The BioCAT undulator beamline 18ID: A facility for biological non-crystalline diffraction and x-ray absorption spectroscopy at the APS

The 18ID undulator beamline of the Biophysics Collaborative Access Team at the Advanced Photon Source, Argonne, IL, USA, is a high-performance instrument designed for, and dedicated to, the study of partially ordered and disordered biological materials using the techniques of small-angle X-ray scattering, fiber diffraction, and X-ray absorption spectroscopy. The beamline and associated instrumentation are described in detail and examples of the representative experimental results are presented.

43 PARTICLE ACCELERATORS↗

High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam

A pre-focused X-ray beam at 12 keV and 9 keV has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam. The BioCAT undulator X-ray beamline 18ID at the Advanced Photon Source was used to generate the pre-focused beam containing 1.2 x 10{sup 13} photons s{sup -1} using a sagittal-focusing double-crystal monochromator and a bimorph mirror. The capillary entrance was aligned with the focal point of the pre-focused beam in order to accept the full flux of the undulator beam. Two alignment configurations were tested: (i) where the center of the capillary was aligned with the pre-focused beam ('in-line') and (ii) where one side of the capillary was aligned with the beam ('off-line'). The latter arrangement delivered more flux (3.3 x 10{sup 12} photons s{sup -1}) and smaller spot sizes ({le}10 {micro}m FWHM in both directions) for a photon flux density of 4.2 x 10{sup 10} photons s{sup -1} {micro}m{sup -2}. The combination of the beamline main optics with a large-working-distance (approximately 24 mm) capillary used in this experiment makes it suitable for many microprobe fluorescence applications that require a micrometer-size X-ray beam and high flux density. These features are advantageous for biological samples, where typical metal concentrations are in the range of a few ng cm{sup -2}. Micro-XANES experiments are also feasible using this combined optical arrangement.

43 PARTICLE ACCELERATORS↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

BioCARS: a synchrotron resource for time-resolved X-ray science

BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick-Baez mirror system capable of focusing the X-ray beam to a spot size of 90 {micro}m horizontal by 20 {micro}m vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to {approx}4 x 10{sup 10} photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450-2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.

43 PARTICLE ACCELERATORS↗

Bent Bragg–Laue monochromator for high-energy X-rays

A bent Bragg–Laue monochromator (BLM) is proposed for high-energy X-ray (~25–60 keV) beamlines. The BLM has the unique feature of bi-directional focusing. A sagittally bent Laue crystal can focus the large horizontal fan of a bending magnet or wiggler source. A meridionally bent Bragg crystal focuses the beam vertically and corrects for the anticlastic bending effects of the Laue crystal. This monochromator geometry relies on the crystal orientations being optimized. We show that the focusing condition and Rowland condition can be simultaneously satisfied at a given energy. A detailed ray tracings indicate that a BLM can provide similar energy resolution and higher flux density compared to a sagittally bent double-Laue monochromator configuration. A prototype BLM with a symmetric Bragg crystal and an asymmetric Laue crystal was tested. Matching of the bend radii of the two crystals in the meridional direction was demonstrated. Generally, the horizontal acceptance of the sagittally bent Laue crystal is limited by the large curvature. This horizontal BLM acceptance could be increased by translating the Laue crystal along its sagittal bending axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aluminum coatings in the undulator vacuum chamber for the linac coherance light source.

A prototype vacuum chamber is under development at the advanced photon source that is intended for use in the linac coherent light source at Stanford linear accelerator center. The chamber will be fabricated from the austenite stainless steels. The chamber requires a continuous aluminum coating on the inner surface in order to reduce the wakefield losses to a level within the resistivity budget. The method being presented here is unique in that it can be applied to a fully fabricated chamber 5 mm high, 12.5 mm wide, and 3460 mm long. In existing methods the chamber aperture has been much larger than is used here. This paper describes a method applicable for these smaller cross sections. This process uses a pair of small electrodes, centered in the aperture, where they are attached to a high-frequency AC power supply. In this configuration each electrode is connected to the opposite polarity of the other. The chamber cavity is filled with argon gas to facilitate the formation of a glow discharge causing the aluminum electrodes to sputter onto the chamber walls. This paper presents the laboratory test results from small samples up to the full- sized assemblies.

36 MATERIALS SCIENCE↗

Development of a model superconducting helical undulator for the ILC positron source.

The helical undulator for the proposed International Linear Collider (ILC) positron source requires high-permeability steel poles and superconducting coils to meet the ILC parameters. A short-model undulator with a period of 14 mm was designed, fabricated including high-permeability steel poles, and tested in LHe. The ends of the model were designed to wind the Nb{sub 3}Sn double helix without any conductor joints. After a few quenches in the first excitation test, the current density in the coil reached 1.28 kA/mm{sup 2}, which was approximately 90% of the estimated short-sample critical current density. The periodic on-axis fields were mapped at two azimuth angles. Excluding the end fields, the standard deviation of the field amplitudes and higher harmonic coefficients for the periodic field were less than 7 x 10{sup -3} and 5 x 10{sup -3}, respectively.

36 MATERIALS SCIENCE↗

A possibility for using an APPLE undulator to generate a photon beam with transverse optical modes.

We investigate use of an APPLE-type undulator for generating Laguerre-Gaussian (LG) and Hermite-Gaussian (HG) mode beams. We find that the second harmonic radiation in the circular mode corresponds to an LG beam with l=1, and the second harmonic in the linear mode corresponds to an HG beam with l=1. The combination of an APPLE undulator and conventional monochromator optics may provide an opportunity for a new type of experimental research in the synchrotron radiation community.

43 PARTICLE ACCELERATORS↗

LCLS undulator production.

Design and construction of the undulators for the linac coherent light source (LCLS) at the Stanford Linear Accelerator Center (SLAC) is the responsibility of Argonne National Laboratory (ANL). A full-scale prototype undulator was constructed in-house and extensively tested at Argonne's advanced photon source (APS). The device was tunable to well within the LCLS requirements and was stable for five years. Experience constructing the prototype undulator led us to conclude that with appropriate engineering design and detailed assembly procedures, precision undulators can be constructed by highly-qualified industrial vendors without undulator-construction experience. Argonne's detailed technological knowledge and experience were transferred to the successful bidders who produced outstanding undulators. Our production concept for the 3.4-m-long, fixed-gap, planar-hybrid undulators with a 30-mm period is discussed. Manufacturing, quality assurance, and acceptance testing details are also presented.

43 PARTICLE ACCELERATORS↗

The Advanced Photon Source pulsed deflecting cavity RF system.

The Advanced Photon Source Deflecting Cavity System for producing short X-ray pulses uses two multi-cell, S-band cavities to apply a deflecting voltage to the stored electron beam ahead of an undulator that supports a beamline utilizing picosecond X-rays. Two additional multi-cell cavities are then used to cancel out the perturbation and restore the electron beam to its nominal orbit. The pulsed rf system driving the deflecting cavities is described. Design tradeoffs are discussed with emphasis on topology considerations and digital control loops making use of sampling technology in a manner consistent with the present state of the art.

43 PARTICLE ACCELERATORS↗