Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dynamic signal recovery in distribution grids using compressive lossy measurements

Distribution system state estimation requires reliable aggregation of the measured data. However, the large volume of the measured data imposes a significant stress on the underlying communication infrastructure. With the challenges associated with measurement availability, current distribution systems are typically unobservable. To cope with the unobservability issue, compressive sensing theory allows us to recover system state information from a small number of measurements provided the states of the distribution system exhibit sparsity. In this paper, we evaluate the robustness of an updated Kalman filtered modified compressive sensing (KF-ModCS) technique that dynamically estimates the grid states using a small fraction of measured data. In practice, measurements used for sparsity based state estimation may also be intermittent due to communication network induced losses. Further, to understand the effect of packet losses on KF-ModCS, we provide an upper bound for the expected variances of the state estimation error for a given rate of information loss. This upper bound is further improved if the support set of the sparse signal that characterizes the state dynamics does not change over time and/or the reduced model is observable. Simulations based on two practical data sets collected from actual customers in a distribution grid validate the theoretical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compressibility measurements of gases using externally heated pressure vessels.

Most of the data collected under conditions of high temperature and pressure have been determined using a thick-walled bomb of carefully measured and fixed volume which is externally heated by an electric furnace or a thermostatically controlled bath. There are numerous variations on the basic method depending on the pressure-temperature range of interest, and the particular gas or gas mixture being studied. The construction and calibration of the apparatus is discussed, giving attention to the pressure vessel, the volume of the bomb, the measurement of pressure, the control and measurement of temperature, and the measurement of the amount and composition of gas in the bomb.

Presnall, D. C.↗

Wireless Fluid-Level Measurement System Equips Boat Owners

While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

Source record↗

YF 102 in-duct combustor noise measurements with a turbine nozzle, volume 1

The internal noise generated by an Avco Lycoming YF-102 engine combustor installed in a test rig was recorded. Two configurations were tested one with and one without the first stage turbine nozzle installed. Acoustic probes and accessories were used. Internal dynamic pressure level measurements were made at ten locations within the combustor. The combustor rig, the test procedures, and data acquisition and reduction systems are described. Tables and plots of narrow band and one third octave band pressure level spectra are included.

Wilson, C. A.↗

Alaska: Glaciers of Kenai Fjords National Park and Katmai National Park and Preserve (Chapter 12)

Much recent research points to the shrinkage of the Earth's small glaciers, however, few studies have been performed to quantify the amount of change over time. We measured glacier-extent changes in two national parks in southeastern Alaska. There are hundreds of glaciers in Kenai Fjords National Park (KEFJ) and Katmai National Park and Preserve (KATM) covering over 2373 sq km of parkland. There are two primary areas of glaciation in KEFJ - the Harding Icefield and the Grewingk-Yalik Glacier Complex, and three primary areas of glaciation in KATM - the Mt. Douglas area, the Kukak Volcano to Mt. Katmai area and the Mt. Martin area. We performed glacier mapping using satellite imagery, from the 1970s, 1980s, and from 2000. Results of the analysis show that there has been a reduction in the amount of glacier ice cover in the two parks over the study period, of approximately 22 sq km of ice, approximately - 1.6% from 1986 to 2000 (for KEFJ), and of approximately 76 sq km of glacier ice, or about -7.7% from 1986187 to 2000 (for KATM). In the future, measurements of surface elevation changes of these ice masses should be acquired; together with our extent-change measurements, the volume change of the ice masses can then be determined to estimate their contribution to sea-level rise. The work is a continuation of work done in KEFJ, but in KATM, our measurements represent the first comprehensive study of the glaciers in this remote, little-studied area.

Giffen, Bruce A.↗

ATMOS/ATLAS-3 Measurements of Stratospheric Chlorine and Reactive Nitrogen Partitioning Inside and Outside the November 1994 Antarctic Vortex

Partitioning between HCl and ClONO2 and among the main components of the reactive nitrogen family (NO, NO2, HNO3, ClONO2, N2O5, and HO2NO2) has been studied inside and outside the Antarctic stratospheric vortex based on ATMOS profiles measured at sunrise during the 3-12 November 1994 ATLAS-3 Shuttle mission. Elevated mixing ratios of HCl in the lower stratosphere with a peak of approximately 2.9 ppbv (10(exp -9) parts per volume) were measured inside the vortex near 500 K potential temperature (approximately 19 km). Maximum ClONO2 mixing ratios of approximately 1.2, approximately 1.4, and approximately 0.9 ppbv near 700 K (approximately 25 km) were measured inside, at the edge, and outside the vortex, respectively. Model calculations reproduce the higher levels of HCl and NO(x) (NO + NO2) inside the lower stratospheric vortex both driven by photochemical processes initiated by low O3. The high HCl at low O3 results from chemical production of HC1 via the reaction of enhanced Cl with CH4, limited production of ClONO2, and the descent of inorganic chlorine from higher altitudes.

Rinsland, C. P.↗

Optical measurements of soot in premixed flames

Two laser diagnostic techniques were used to measure soot volume fractions, number densities and soot particle radii in premixed propane/oxygen flat flames. The two techniques were two wavelength extinction, using 514.5 to 632.8 nm and 457.9 to 632.8 nm wavelength combinations, and extinction/scattering using 514.5 nm light. The flames were fuel rich and had cold gas velocities varying from 3.4 to 5.5 cm/s. Measurements were made at various heights above the sintered bronze, water colored flat flame burner with the equivalence ratio and cold gas velocity fixed. Also, measurements were made at a fixed height above the burner and fixed cold gas velocity while varying the equivalence ratio. Both laser techniques are based on the same underlying assumptions of particle size distribution and soot optical properties. Full Mie theory was used to determine the extinction coefficients and the scattering efficiencies. Temperature measurements in the flame were made using infrared radiometry and fine wire thermocouples. Good agreement between the two techniques in terms of soot particle radii, number density and volume fraction was found for intensity ratios between 0.1 and 0.8.

Lyons, Valerie J.↗

Bulk modulus measurement at mHz frequencies and high-pressure using synchrotron x-ray radiation

We report an experimental protocol for measuring the frequency dependence of the bulk modulus carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. An oscillating pressure perturbation characterized by x-ray diffraction produces a volume strain measured by imaging. Together, these yield the bulk modulus of the sample. In this work, we report data at 3 mHz as an example of the possibility of providing these data for the frequency range of 1 mHz–100 mHz.

47 OTHER INSTRUMENTATION↗

Infiltration/cure modeling of resin transfer molded composite materials using advanced fiber architectures

A model was developed which can be used to simulate infiltration and cure of textile composites by resin transfer molding. Fabric preforms were resin infiltrated and cured using model generated optimized one-step infiltration/cure protocols. Frequency dependent electromagnetic sensing (FDEMS) was used to monitor in situ resin infiltration and cure during processing. FDEMS measurements of infiltration time, resin viscosity, and resin degree of cure agreed well with values predicted by the simulation model. Textile composites fabricated using a one-step infiltration/cure procedure were uniformly resin impregnated and void free. Fiber volume fraction measurements by the resin digestion method compared well with values predicted using the model.

Loos, Alfred C.↗

Optical measurements of soot and temperature profiles in premixed propane-oxygen flames

Two laser diagnostic techniques were used to measure soot volume fractions, number densities and soot particle radii in premixed propane/oxygen flat flames. The two techniques used were two wavelength extinction, using 514.5 nm to 632.8 nm and 457.9 nm to 632.8 nm wavelength combinations, and extinction/scattering using 514.5 nm light. The flames wre fuel-rich (equivalence ratios from 2.1 to 2.8) and had cold gas velocities varying from 3.4 to 5.5 cm/s. Measurements were made at various heights above the sintered-bronze, water-cooled flat flame burner with the equivalence ratio and cold gas velocity fixed. Also, measurements were made at a fixed height above the burner and fixed cold gas velocity while varying the equivalence ratio. Both laser techniques are based on the same underlying assumptions of particle size distribution and soot optical properties. Full Mie theory was used to determine the extinction coefficients K sub ext, and the scattering efficiencies, Q sub vv. Temperature measurements in the flames were made using infrared radiometry. Good agreement between the two techniques in terms of soot particle radii, number density and volume fraction was found for intensity ratios (I/I sub o) between 0.1 and 0.8. For intensity ratios higher or lower than this range, the differences in extinction coefficients at the wavelengths chosen for the two-wavelength method are too small to give accurate results for comparing particle radii and number densities. However, when comparing only soot volume fractions, the agreement between the two techniques continued to be good for intensity ratios up to 0.95.

Lyons, Valerie J.↗

Optical measurements of soot and temperature profiles in premixed propane-oxygen flames

Two laser diagnostic techniques were used to measure soot volume fractions, number densities and soot particle radii in premixed propane/oxygen flat flames. The two techniques used were two wavelength extinction, using 514.5 nm to 632.8 nm and 457.9 nm to 632.8 nm wavelength combinations, and extinction/scattering using 514.5 nm light. The flames were fuel-rich (equivalence ratios from 2.1 to 2.8) and had cold gas velocities varying from 3.4 to 5.5 cm/s. Measurements were made at various heights above the sintered-bronze, water-cooled flat flame burner with the equivalence ratio and cold gas velocity fixed. Also, measurements were made at a fixed height above the burner and fixed cold gas velocity while varying the equivalence ratio. Both laser techniques are based on the same underlying assumptions of particle size distribution and soot optical properties. Full Mie theory was used to determine the extinction coefficients K sub ext, and the scattering efficiencies, Q sub vv. Temperature measurements in the flames were made using infrared radiometry. Good agreement between the two techniques in terms of soot particle radii, number density and volume fraction was found for intensity ratios (I/I sub o) between 0.1 and 0.8. For intensity ratios higher or lower than this range, the differences in extinction coefficients at the wavelengths chosen for the two-wavelength method are too small to give accurate results for comparing particle radii and number densities. However, when comparing only soot volume fractions, the agreement between the two techniques continued to be good for intensity ratios up to 0.95.

Lyons, V. J.↗

Development of an Inline Urine Monitoring System for the International Space Station

Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

Broyan, James Lee, Jr.↗

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Non-NASA Center↗

Measurement of coronal X-ray emission lines from Capella

The Einstein Observatory's Focal Plane Crystal Spectrometer has detected X-ray emission lines due to O VIII, Fe XVII, and Fe XX, from the binary star system Capella. Line luminosities are well fitted by an emitting plasma at a single temperature of 6.29 + or - 0.01 - 0.03 million K, and a volume emission measure of about 8.6 x 10 to the 52nd/cu cm, corresponding to the low temperature component previously observed. A high temperature component is undetectable, since the observed lines are not produced in plasma at temperatures above about 20 million K. Nearly isothermal plasma would be expected if many of the magnetically confined coronal loops have similar sizes and pressures, and a second population of longer loops would be required to account for the hotter component. An alternative interpretation of the observed X-ray line emission and upper limit is that the plasma contains a continuous distribution of emission measure versus temperature that rises sharply to 3 million K and then falls by nearly a decade to 16 million. An extrapolation of the loop sizes suggested by this alternative to hotter, longer loops may also account for the higher temperature emission.

Vedder, P. W.↗

Cloud volume studies

A time history of cloud growth for the Titan 3 launch was obtained by using optical data provided by three Askania trackers (position of the cloud) and three Hasselblad cameras (cloud volume). Two quasi-independent measurements of ground cloud volume as a function of time were obtained. Aircraft time in the cloud, as measured by the rapid response nephelometer onboard the aircraft, was used for determining cloud volume. Cloud volume from aircraft measurements for the entire operation is summarized.

Bendura, R. J.↗

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos 𝜈𝑒 observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the “gallium anomaly,” which could be interpreted as evidence for oscillations between 𝜈𝑒 and sterile neutrino (𝜈 𝑠 ) states. A 3.414-MCi 51 Cr 𝜈 𝑒 source was placed at the center of two nested Ga volumes and measurements were made of the production of 71 Ge through the charged current reaction, 71 Ga ⁢(𝜈 𝑒 ,𝑒 − ) ⁢71 Ge, at two average distances. The measured production rates for the inner and the outer targets, respectively, are [54.9$^{+2.5}_{−2.4}$⁢(stat) ± 1.4⁢(syst)] and [55.6$^{+2.7}_{−2.6}$⁢(stat) ± 1.4⁢(syst)] atoms of 71 Ge/𝑑. The ratio (𝑅) of the measured rate of 71 Ge production at each distance to the expected rate from the known cross section and experimental efficiencies are 𝑅 in = 0.79 ± 0.05 and 𝑅 out = 0.77 ± 0.05. The ratio of the outer to the inner result is 0.97 ± 0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20%–24% lower than expected, thus reaffirming the anomaly. Furthermore, these results are consistent with 𝜈 𝑒 → 𝜈 𝑠 oscillations with a relatively large Δ⁢𝑚 2 (>0.5 eV 2 ) and mixing sin 2 ⁡2⁢𝜃 (≈ 0.4).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma viscosity elevations with simulated weightlessness

A hypothesis correlating an increase in blood viscosity during bed rest to a decrease in aerobic capacity during simulated weightlessness is tested. Eight human subjects were studied on the sixth day of bed rest during two consecutive 10-d bed rest periods separated by a 14-d recovery interval designed to simulate the flight-layover schedule of Shuttle astronauts. Plasma viscosity and volume were measured, together with maximal aerobic capacity (VO2max). An increase in hematocrit, plasma protein, and fibrinogen concentrations was found, contributing to an elevation in plasma viscosity. VO2max decreased significantly in the first, but not the second bed rest cycle, and though many individuals exhibited a decrease in plasma volume and aerobic capacity coupled with elevated plasma viscosity, correlations between these variables were lacking. It is concluded that the decrease in VO2max observed following simulated weightlessness cannot be attributed to alterations in muscle blood flow resulting from increased blood viscosity.

Martin, D. G.↗

Measurement of G-phase volume fraction and number density in duplex stainless steels using transmission electron microscopy

Duplex stainless steels (DSS) have a high toughness and strength due the presence of both austenitic and ferritic phases. These alloys have had limited use in power production applications due to thermal embrittlement caused by spinodal decomposition and development of G-phase precipitates in the ferrite. Lean grade DSS alloys (e.g., 2101, 2003) may offer improved thermal stability due to the reduction of Cr- and Ni-equivalent elements when compared to standard grade compositions (e.g., 2205, 2209). The abundance of the G-phase was measured in five duplex stainless steels, three wrought alloys (2101, 2003, 2205) and their matching filler metals (2101-w, 2209-w), after aging at 427 °C for 1000 h and 10,000 h. The G-phase volume fraction, number density, size, and precipitate spacing were found using quantitative analysis of transmission electron microscopy dark field images and the composition of G-phase precipitates on other clusters were characterized with atom probe tomography (APT). In the welded alloys, the G-phase was found to develop rapidly, relative to the wrought material. A positive correlation was found between the nickel equivalent composition of the alloy and the G-phase volume fraction. The alloys 2205, 2209, and 2101-w, which are higher in Cr and Ni, all showed significant G-phase precipitation, further strengthening the hypothesis that lean grade DSS alloys are more thermally stable against precipitation in the ferrite. Electron diffraction showed a secondary phase present in the 2101 wrought alloy at 10,000 h, but it was not crystallographically consistent with the G-phase; APT showed the presence of nanoclusters rich in both nickel and copper for this alloy. In conclusion, no secondary phases or clusters were found in 2003 after 10,000 h of aging, so it may be a candidate alloy for applications that require long-life times at high operating temperatures.

36 MATERIALS SCIENCE↗