Simultaneous Vibration and Acoustic Measurements of a Store in Compressible Open Cavity Flow.
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Explore the source record for details and available documents.
Measured and predicted longitudinal vibrations of liquid propellant two-stage launch vehicle
Apparatus measures work function of possibly contaminated surface of specimen of metal or other electrically conductive material. Measures work function of specimen indirectly, by vibrating capacitive measurement of contact potential. Work function of specimen affected by microstructure and by contamination.
We performed the experiments on measurement of vibration amplitudes for microparticles in gas and water with laser heterodyne receiver of scattered radiation. The measured vibration amplitude values are about 20 nm.
Laser Doppler vibrometry is a well proven tool for the non-contact measurement of vibration. The scanning of several measurement points allows to visualize the deflection shape of the component, ideally a 3D-operating deflection shape, if a 3-D scanner is applied. Measuring the points sequentially, however, requires stationary behavior during the measurement time. This cannot be guaranteed for many real objects. Therefore, a multipoint laser Doppler vibrometer has been developed by Polytec and the University of Stuttgart with Bosch as industrial partner. A short description of the measurement system is given. Applications for the parallel measurement of the vibration of several points are shown for non-stationary vibrating Bosch components such as power-tools or valves.
The characteristics of a holographic interferometer, which is based on the interaction of counterpropagating light waves on reflective holograms in cubic photorefractive sillenite crystals of the (100) cut and designed for measuring surface vibration spectra from specularly reflecting objects, have been theoretically analysed and experimentally studied. The experiments showed that an interferometer of this type, based on an Bi{sub 12}TiO{sub 20} : Fe,Cu crystal, makes it possible to measure vibrations with an amplitude of 5 pm. An analysis performed with allowance for the shot and thermal noise of the photodetector showed that vibrations with an amplitude below 1 pm can be measured. A model is proposed to describe the experimentally found strong temperature dependence of the light interaction on reflection holograms in a Bi{sub 12}TiO{sub 20} : Ca crystal. This model takes into account the influence of temperature on the photoinduced charge redistribution over deep donor and shallow trap centres, as well as the drift of the interference pattern in the crystal due to the thermooptical effect and linear expansion of the crystal.
It is clear that additional experience and validation of Control Structures Interaction (CSI) techniques are needed in controlling the structural dynamics of flexible spacecraft. It is also clear that the effects of the space environment such as weightlessness dictate that this be done in space. Unfortunately, orbital tests are difficult to achieve because of the high cost of the test article, the launch into orbit, the instrumentation, and communication systems. The Low-power Atmospheric Compensation Experiment (LACE) Satellite has provided an opportunity to achieve a CSI test in space for very little cost. First, the CSI test rode piggy-back and did not interfere with the primary objective of LACE. Second, the novel technique of using ground based measurements of vibration of the orbiting satellite was employed. The LACE has a heavy central body to which is attached booms with lengths as long as 150 feet. The ground measurements were obtained using laser Doppler radar at the MIT Lincoln Laboratory Firepond Facility. The initial tests demonstrated the accuracy of the vibration measurements and obtained structural responses for enhancing the accuracy of the mathematical model of the structural dynamics. Germanium corner-cube retroreflectors attached to the central body and a boom deployed to 18 feet ensured a high strength return signal. Subsequent tests demonstrated the ability of an open-loop damper to attenuate the vibrations of the orbiting satellite. The LACE test results are important in contributing to the validation of a CSI technique, and demonstrating a novel ground measurement technique for orbital tests that is accurate but which has very low cost.
Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.
A Small Business Innovation Research (SBIR) sponsorship from NASA's Dryden Flight Research Center, assisted MetroLaser, of Irvine, California, in the development of a self-aligned laser vibrometer system. VibroMet, capable of measuring surface vibrations in a variety of industries, provides information on the structural integrity and acoustical characteristics of manufactured products. This low-cost, easy-to-use sensor performs vibration measurement from distances of up to three meters without the need for adjustment. The laser beam is simply pointed at the target and the system then uses a compact laser diode to illuminate the surface and to subsequently analyze the reflected light. The motion of the surface results in a Doppler shift that is measured with very high precision. VibroMet is considered one of the many behind-the-scenes tools that can be relied on to assure the quality, reliability and safety of everything from airplane panels to disk brakes
Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.
Spectroscopic technique for measurement of nonequilibrium shock front rotational, vibrational, and electronic temperatures
The vibration characteristics of a composite fan blade for high-tip-speed applications were determined theoretically and the results compared with measured data. The theoretical results were obtained using a computerized capability consisting of NASTRAN coupled with composite mechanics by way of pre- and postprocessors. The predicted vibration frequencies and mode shapes were in reasonable agreement with the measured data. Theoretical results showed that different laminate configurations from the same composite system had only small effects on the blade frequency. However, the use of adhesively bonded titanium/beryllium laminar composites may improve considerably the blade vibration characteristics.
The vibration characteristics of a composite fan blade for high-tip-speed applications were determined theoretically and the results compared with measured data. The theoretical results were obtained using a computerized capability consisting of NASTRAN coupled with composite mechanics by way of pre- and postprocessors. The predicted vibration frequencies and mode shapes were in reasonable agreement with the measured data. Theoretical results showed that different laminate configurations from the same composite system had only small effects on the blade frequency. However, the use of adhesively bonded titanium/beryllium laminar composites may improve considerably the blade vibration characteristics.
The vibrational density of states (DOS) of hydrogen trapped at dislocations in deformed PdH{sub 0.0008} has been measured at 4 and 295 K with incoherent inelastic neutron scattering. The vibrational DOS at 4 K exhibits features characteristic of the low-temperature {beta}-Pd hydride phase while the characteristic peak in the 295 K DOS corresponds to the solid-solution {alpha}-Pd phase. This is evidence of a {alpha}{yields}{beta} transition at low temperature within the distorted environment of dislocations.
Enhancing the spatial and temporal resolution of vibration measurements and modal analysis could significantly benefit dynamic modelling, analysis, and health monitoring of structures. For example, spatially high-density mode shapes are critical for accurate vibration-based damage localization. In experimental or operational modal analysis, higher (frequency) modes, which may be outside the frequency range of the measurement, contain local structural features that can improve damage localization as well as the construction and updating of the modal-based dynamic model of the structure. In general, the resolution of vibration measurements can be increased by enhanced hardware. Traditional vibration measurement sensors such as accelerometers have high-frequency sampling capacity; however, they are discrete point-wise sensors only providing sparse, low spatial sensing resolution measurements, while dense deployment to achieve high spatial resolution is expensive and results in the mass-loading effect and modification of structure's surface. Non-contact measurement methods such as scanning laser vibrometers provide high spatial and temporal resolution sensing capacity; however, they make measurements sequentially that requires considerable acquisition time. As an alternative non-contact method, digital video cameras are relatively low-cost, agile, and provide high spatial resolution, simultaneous, measurements. Combined with vision based algorithms (e.g., image correlation or template matching, optical flow, etc.), video camera based measurements have been successfully used for experimental and operational vibration measurement and subsequent modal analysis. However, the sampling frequency of most affordable digital cameras is limited to 30–60 Hz, while high-speed cameras for higher frequency vibration measurements are extremely costly. This work develops a computational algorithm capable of performing vibration measurement at a uniform sampling frequency lower than what is required by the Shannon-Nyquist sampling theorem for output-only modal analysis. In particular, the spatio-temporal uncoupling property of the modal expansion of structural vibration responses enables a direct modal decoupling of the temporally-aliased vibration measurements by existing output-only modal analysis methods, yielding (full-field) mode shapes estimation directly. Then the signal aliasing properties in modal analysis is exploited to estimate the modal frequencies and damping ratios. Furthermore, the proposed method is validated by laboratory experiments where output-only modal identification is conducted on temporally-aliased acceleration responses and particularly the temporally-aliased video measurements of bench-scale structures, including a three-story building structure and a cantilever beam.
The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.
Noncontacting displacement measuring technique and applications to vibration testing