Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dynamic pressure transducer system for pulsed plasma flow diagnosis.

The response characteristics of high sensitivity piezoelectric pressure transducers suitable for use in the plasma flow induced by megawatt-level electric discharges in low density (less than 1 Torr) gases are described. The uniquely designed probe records the initial impingement of a large magnitude total pressure pulse, followed by the flow of primary interest with order-of-magnitude smaller signals. Effects relating to probe and support accelerations, blast shielding and probe heating are evaluated and accounted for in a probe system with a sensitivity of 40 V/atm.

York, T. M.↗

Subminiature transducers for measuring forces and deformation of heart muscle

Two subminiature transducers, one measuring muscle forces and one measuring muscle displacement, can be inserted into heart muscle without interfering with it. Probe, approximately 1 mm (0.04 in), causes no damage to heart muscle. Probe can be rotated to different positions to measure muscle forces from various directions.

Feldstein, C.↗

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.↗

A high-temperature wideband pressure transducer

Progress in the development of a pressure transducer for measurement of the pressure fluctuations in the high temperature environment of a jet exhaust is reported. A condenser microphone carrier system was adapted to meet the specifications. A theoretical analysis is presented which describes the operation of the condenser microphone in terms of geometry, materials, and other physical properties. The analysis was used as the basis for design of a prototype high temperature microphone. The feasibility of connecting the microphone to a converter over a high temperature cable operating as a half-wavelength transmission line was also examined.

Zuckerwar, A. J.↗

Application of rotor mounted pressure transducers to analysis of inlet turbulence

Miniature pressure transducers installed near the leading edge of a fan blade were used to diagnose the non-uniform flow entering a subsonic tip speed turbofan on a static test stand. The pressure response of the blade to the inlet flow variations was plotted in a form which shows the space-time history of disturbances ingested by the rotor. Also, periodically sampled data values were auto- and cross-correlated as if they had been acquired from fixed hot wire anemometers at 150 equally spaced angles around the inlet. With a clean inlet and low wind, evidence of long, narrow turbulence eddies was easily found both in the boundary layer of the fan duct and outside the boundary layer. The role of the boundary layer was to follow and amplify disturbances in the outer flow. These eddies frequently moved around the inlet with a corkscrew motion as they passed through.

Hanson, D. B.↗

Myocardium wall thickness transducer and measuring method

A miniature transducer for measuring changes of thickness of the myocardium is described. The device is easily implantable without traumatizing the subject, without affecting the normal muscle behavior, and is removable and implantable at a different muscle location. Operating features of the device are described.

Feldstein, C.↗

Catheter tip force transducer for cardiovascular research

A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

Feldstein, C.↗

Vacuum mounting for piezoelectric transducers

Special housing couples piezoelectric transducers to nonporous surfaces for ultrasonic or acoustic-emission testing. Device, while providing sound isolation on flat or nonflat surfaces, can be attached and detached quickly. Vacuum sealing mechanism eliminates need for permanent or semipermanent bonds, viscous coupling liquids, weights, magnets, tape, or springs ordinarily used.

Tiede, D. A.↗

Improved myocardium transducer

Method of implanting myocardium transducer uses special indented pins that are caught and securely held by epicardial fibers. Pins are small enough to cause minimum of trauma to myocardium during implantation or removal.

Culler, V. H.↗

High-temperature capacitive pressure transducer

Capacitive pressure transducer operates continuously at temperatures as high 1,2000 F, and has been evaluated over full-scale differential pressure range of + or - 10 psi (69 x 1000 N/sq m).

Egger, R. L.↗

Ultrathin films as photomechanical transducer

Stretched ultrathin, metallized polyimide film is used as photochemical transducer for detection and measurement of total exposure to light. Film is potential nonelectrical replacement for solar cells.

Fedors, R. F.↗

Optically selective, acoustically resonant gas detecting transducer

A gas analyzer is disclosed which responds to the resonant absorption or emission spectrum of a specific gas by producing an acoustic resonance in a chamber containing a sample of that gas, and which measures the amount of that emission or absorption by measuring the strength of that acoustic resonance, e.g., the maximum periodic pressure, velocity or density achieved. In the preferred embodiment, a light beam is modulated periodically at the acoustical resonance frequency of a closed chamber which contains an optically dense sample of the gas of interest. Periodic heating of the absorbing gas by the light beam causes a cyclic expansion, movement, and pressure within the gas. An amplitude is reached where the increased losses were the cyclic radiation energy received. A transducing system is inclined for converting the pressure variations of the resonant gas into electronic readout signals.

Dimeff, J.↗

Pressure transducer

A pressure transducer is described in which the sensing element is a crystal of the monomeric charge transfer complex of pyrene and tetracyanoethylene.

Rembaum, A.↗

Comparison of concurrent strain gage- and pressure transducer-measured flight loads on a lifting reentry vehicle and correlation with wind tunnel predictions

Concurrent strain gage and pressure transducer measured flight loads on a lifting reentry vehicle are compared and correlated with wind tunnel-predicted loads. Subsonic, transonic, and supersonic aerodynamic loads are presented for the left fin and control surfaces of the X-24B lifting reentry vehicle. Typical left fin pressure distributions are shown. The effects of variations in angle of attack, angle of sideslip, and Mach number on the left fin loads and rudder hinge moments are presented in coefficient form. Also presented are the effects of variations in angle of attack and Mach number on the upper flap, lower flap, and aileron hinge-moment coefficients. The effects of variations in lower flap hinge moments due to changes in lower flap deflection and Mach number are presented in terms of coefficient slopes.

Tang, M. H.↗

Attaching strain transducers to fragile materials

A-shaped clamp prevents damage to thin, brittle specimens and supports displacement transducer away from heated zone. Also it defines reference points for strain measurement on specimen surface thus preventing specimen cracking due to unequal thermal expansion between clamp and holder.

Duggan, M. F.↗

Adaptation of ion beam technology to microfabrication of solid state devices and transducers

A number of areas were investigated to determine the potential uses of ion beam techniques in the construction of solid state devices and transducers and the packaging of implantable electronics for biomedical applications. The five areas investigated during the past year were: (1) diode-like devices fabricated on textured silicon; (2) a photolithographic technique for patterning ion beam sputtered PVC (polyvinyl chloride); (3) use of sputtered Teflon as a protective coating for implantable pressure sensors; (4) the sputtering of Macor to seal implantable hybrid circuits; and (5) the use of sputtered Teflon to immobilize enzymes.

Topich, J. A.↗