At least 343 records · Page 19

Navigation analysis for Viking 1979, option B

A parametric study performed for 48 trans-Mars reference missions in support of the Viking program is reported. The launch dates cover several months in the year 1979, and each launch date has multiple arrival dates in 1980. A plot of launch versus arrival dates with case numbers designated for reference purposes is included. The analysis consists of the computation of statistical covariance matrices based on certain assumptions about the ground-based tracking systems. The error model statistics are listed in tables. Tracking systems were assumed at three sites: Goldstone, California; Canberra, Australia; and Madrid, Spain. The tracking data consisted of range and Doppler measurements taken during the tracking intervals starting at E-30(d) and ending at E-10(d) for the control data and ending at E-18(h) for the knowledge data. The control and knowledge covariance matrices were delivered to the Planetary Mission Analysis Branch for inputs into a delta V dispersion analysis.

Mitchell, P. H.↗

Measurement of the power spectral density of phase of the hydrogen maser

Hydrogen masers are being developed for the Deep Space Network as improved frequency standards, in order to achieve better timing accuracies, reduced Doppler residuals, and lower phase noise in the tracking system. Performance data for the masers are given in two forms: time domain performance, useful for analyzing time keeping systems and Doppler systems; and frequency domain performance, useful for analyzing tracking systems. Particular attention is given to frequency domain performance, as obtained from both time domain measurements and direct measurements.

Sward, A.↗

Calibration of the Space Shuttle Microwave Scanning Beam Landing System using a laser tracker

Verification tests of the Space Shuttle Microwave Scanning Beam Landing System (MSBLS) performed with respect to the Precision Laser Tracking System are reported. MSBLS ground station measurements of the azimuth, elevation and range of a NASA Jetstar aircraft equipped with a laser retroreflector, a MSBLS antenna and commissioning instruments including a MSBLS navigation set of the type installed in the Orbiter, during the performance of radial, orbital and glideslope runs with respect to the ground station were compared with laser ground station measurements of aircraft position. Data obtained from flight testing at Shuttle landing sites reveal MSBLS distance measuring equipment performance to be very good, with elevation errors found at very low elevation angles and azimuth errors as a function of aircraft attitude. The Precision Laser Tracking System has thus proven to be a satisfactory instrument for determining MSBLS performance, and an ideal instrument for its calibration.

Ford, K.↗

Combined Feature Based and Shape Based Visual Tracker for Robot Navigation

We have developed a combined feature based and shape based visual tracking system designed to enable a planetary rover to visually track and servo to specific points chosen by a user with centimeter precision. The feature based tracker uses invariant feature detection and matching across a stereo pair, as well as matching pairs before and after robot movement in order to compute an incremental 6-DOF motion at each tracker update. This tracking method is subject to drift over time, which can be compensated by the shape based method. The shape based tracking method consists of 3D model registration, which recovers 6-DOF motion given sufficient shape and proper initialization. By integrating complementary algorithms, the combined tracker leverages the efficiency and robustness of feature based methods with the precision and accuracy of model registration. In this paper, we present the algorithms and their integration into a combined visual tracking system.

Deans, J.↗

TOPEX/Poseidon Precision Orbit Determination Using Combined GPS, SLR, and DORIS

TOPEX/Poseidon (T/P) is a joint spaceborne oceanographic mission of U.W. NASA and France CNES design launched August 10, 1992. The satellite has a variety tracking systems for both operational and precision orbit determination. Three precise tracking systems: Satellite Laser Ranging (SLR), Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), and Global Positioning System (GPS) provide high quality measurements essential for reconstructing the T/P orbital height with centimeter precision. This paper presents results of simultaneously processing all three data types to exploit the inherent strength of each in a combined solution. SLR and DORIS are routinely combined to provide orbit solutions for the T/P science team. GPS orbit solutions are produced as part of the first demonstration flight of a high quality spaceborne GPS receiver. Coordinate frame and software system differences between the combined SLR/DORIS orbits and the GPS orbits induce orbital height differences of 2 to 3 centimeters. Combining the three data types within a single software system permits removal of software system differences while obtaining coordinate frame calibration information. These calibrations will aid future spaceborne GPS missions that are not complemented with SLR and/or DORIS.

TOPEX/Poseidon↗

Infrared Imagery of Shuttle (IRIS). Task 2, summary report

End-to-end tests of a 16 element indium antimonide sensor array and 10 channels of associated electronic signal processing were completed. Quantitative data were gathered on system responsivity, frequency response, noise, stray capacitance effects, and sensor paralleling. These tests verify that the temperature accuracies, predicted in the Task 1 study, can be obtained with a very carefully designed electro-optical flight system. Pre-flight and inflight calibration of a high quality are mandatory to obtain these accuracies. Also, optical crosstalk in the array-dewar assembly must be carefully eliminated by its design. Tests of the scaled up tracking system reticle also demonstrate that the predicted tracking system accuracies can be met in the flight system. In addition, improvements in the reticle pattern and electronics are possible, which will reduce the complexity of the flight system and increase tracking accuracy.

Chocol, C. J.↗

Measurement and calibration of static distortion of position data from 3D trackers

Three-dimensional trackers are becoming increasingly important as user inputs in interactive computer systems. These trackers output the three-dimensional position, and often the orientation, of a sensor in space. The three-dimensional tracking is often, however, highly distorted and inaccurate. The purpose of this paper is to discuss methods for the measurement and characterization of the static distortion of the position data. When the distortion is constant, various methods can be used to calibrate the data from the tracker to increase accuracy. Several preliminary methods are discussed in this paper, including polynomial and weighted lookup methods. The measurement and calibration methods are applied to the Polhemus electromagnetic tracking system, but are applicable to tracking systems based on other technologies.

Bryson, Steve↗

Mobile Aerial Tracking and Imaging System (MATrIS) for Aeronautical Research

A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of reusable launch vehicle configurations. During that study the National Aeronautics and Space Administration teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility to test techniques and analysis on two Space Shuttle flights.

Banks, Daniel W.↗

Mobile Aerial Tracking and Imaging System (MATRIS) for Aeronautical Research

A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles (RLVs) as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of RLV configurations. During that study NASA teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility (MDA/ISTEF) to test techniques and analysis on two Space Shuttle flights.

Banks, Daniel W.↗

Civil helicopter flight operations using differential GPS

The results of NASA flight trials of a dual-receiver differential global positioning system (DGPS) for civilian helicopter navigation applications, are presented. The three principal components of the DGPS system are described, including the GPS ground-reference system, a range tracking system, and an on-board sequential GPS receiver. The ground-based receiver in the DGPS operates at a known fixed location and receives C/A code signals from NAVSTAR satellites. System bias errors in the ground receiver are subtracted from the airborne solution for the navigational fix. Calculations of the differential bias error are carried out using an on-board PDP-11/34 M research computer. The ground-reference differential corrections for satellites are given in a table. It is shown that the differential correction signal of the DGPS contains only a small (0.1 rad/sec) high-frequency component which can be attributed to system error. A schematic diagram of the DGPS postflight data processing routine is provided.

Edwards, F. G.↗

STS-69 Flight Day 5 Video File

Awakening to the theme song of the television show 'Rin Tin Tin', the astronauts, Cmdr. Dave Walker, Pilot Ken Cockrell, and Mission Specialists Jim Voss, Jim Newman, and Mike Gernhardt, of the STS-69 mission began their fifth day in orbit. The deployment of the Wake Shield Facility (WSF) was accomplished successfully, although it was delayed several hours due to communication problems between the satellite and its carrier platform located in the shuttle's cargo bay. The WSF satellite's main purpose was to grow up to seven layers of semiconductor films in a vacuum-like state while orbiting behind the space shuttle. The shuttle's Global Positioning System and Satellite Tracking System were both given checkout tests.

Source record↗

Development of a Water Recovery System Resource Tracking Model

A simulation model has been developed to track water resources in an exploration vehicle using regenerative life support (RLS) systems. The model integrates the functions of all the vehicle components that affect the processing and recovery of water during simulated missions. The approach used in developing the model results in the RTM being a part of of a complete vehicle simulation that can be used in real time mission studies. Performance data for the variety of components in the RTM is focused on water processing and has been defined based on the most recent information available for the technology of the component. This paper will describe the process of defining the RLS system to be modeled and then the way the modeling environment was selected and how the model has been implemented. Results showing how the variety of RLS components exchange water are provided in a set of test cases.

Chambliss, Joe↗

Quantifying Pilot Visual Attention in Low Visibility Terminal Operations

Quantifying pilot visual behavior allows researchers to determine not only where a pilot is looking and when, but holds implications for specific behavioral tracking when these data are coupled with flight technical performance. Remote eye tracking systems have been integrated into simulators at NASA Langley with effectively no impact on the pilot environment. This paper discusses the installation and use of a remote eye tracking system. The data collection techniques from a complex human-in-the-loop (HITL) research experiment are discussed; especially, the data reduction algorithms and logic to transform raw eye tracking data into quantified visual behavior metrics, and analysis methods to interpret visual behavior. The findings suggest superior performance for Head-Up Display (HUD) and improved attentional behavior for Head-Down Display (HDD) implementations of Synthetic Vision System (SVS) technologies for low visibility terminal area operations. Keywords: eye tracking, flight deck, NextGen, human machine interface, aviation

Ellis, Kyle K.↗