Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Three-dimensional tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

329 records · Page 19

Seismic Monitoring at the Farnsworth CO2-EOR Field Using Time-Lapse Elastic-Waveform Inversion of 3D-3C VSP Data

During the Development Phase of the U.S. Southwest Regional Partnership on Carbon Sequestration, supercritical CO2 was continuously injected into the deep oil-bearing Morrow B formation of the Farnsworth Unit in Texas for Enhanced Oil Recovery (EOR). The project injected approximately 94 kilotons of CO2 to study geologic carbon storage during CO2-EOR. A three-dimensional (3D) surface seismic dataset was acquired in 2013 to characterize the subsurface structures of the Farnsworth site. Following this data acquisition, the baseline and three time-lapse three-dimensional three-component (3D-3C) vertical seismic profiling (VSP) data were acquired at a narrower surface area surrounding the CO2 injection and oil/gas production wells between 2014 and 2017 for monitoring CO2 injection and migration. With these VSP datasets, we inverted for subsurface velocity models to quantitatively monitor the CO2 plume within the Morrow B formation. We first built 1D initial P-wave (Vp) and S-wave (Vs) velocity models by upscaling the sonic logs. We improved the deep region of the Vp and Vs models by incorporating the deep part of a migration velocity model derived from the 3D surface seismic data. We improved the shallow region of 3D Vp and Vs models using 3D traveltime tomography of first arrivals of VSP downgoing waves. We further improved the 3D baseline velocity models using elastic-waveform inversion (EWI) of the 3D baseline VSP upgoing data. Our advanced EWI method employs alternative tomographic and conventional gradients and total-variation-based regularization to ensure the high-fidelity updates of the 3D baseline Vp and Vs models. We then sequentially applied our 3D EWI method to the three time-lapse datasets to invert for spatiotemporal changes of Vp and Vs in the reservoir. Our inversion results reveal the volumetric changes of the time-lapse Vp and Vs models and show the evolution of the CO2 plume from the CO2 injection well to the oil/gas production wells.

42 ENGINEERING↗

Uses of Computed Tomography in the NASA Materials Science Program

Computed Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used to characterize materials in preparation for flight, to determine thermal expansion values, and to examine long duration space grown materials, i.e. meteorites. The work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. This will include both the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along single crystals of germanium-silicon alloys. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication and installation of a single zone furnace incorporating a heat pipe to ensure of high temperature uniformity. At the time of writing the thermal expansion of lead has been measured from room temperature to 900 C. Three methods are available. Digital radiography enable length changes to be determined. Prior to melting the sample is small than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the lead alloyed with antimony is ready for scanning. This corresponds to the planned composition of Dr. Poirier's flight experiment. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the iron-nickel phase has coarsened during slow cooling over hundreds of millions of years.

Engel, H. Peter↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗

Three-Dimensional Reconstruction of Defects and Structures in Additively Manufactured Parts with Automated Serial Sectioning

Metal additive manufacturing (AM) processes have been demonstrated to be effective at reducing costs and lead times associated with complex components for space flight applications. Laser powderbed fusion (L-PBF) is a commonly used AM technology due to the ability to produce complex parts with fine feature resolution in a wide variety of alloys and applications. L-PBF, like many other manufacturing processes, can produce minor flaws in parts when in nominal operation as well as process-escape defects when process abnormalities occur. The effects of the flaws and methods of detecting the flaws are a subject of interest to understand the difficulties in detecting these flaws with current technology and how much risk the flaws or defects pose to potential flight parts. Using a RoboMet.3D automated serial sectioning system, seeded defects as well as minor process flaws can be imaged and reconstructed in three dimensions to compare to non-destructive evaluation (NDE) techniques, such as x-ray computed tomography (CT), neutron CT, and in-situ monitoring. The RoboMet automates the metallography process by automatically grinding, polishing, and imaging samples in a single system and providing the control data for NDE comparisons to know the real size of defects built into coupons. These comparisons provide an understanding behind the technological limitations of the NDE techniques for different alloys. The same serial sectioning methods have also been utilized to characterize the surfaces of parts to reconstruct the surfaces and take measurements of internal features not easily examined with non-destructive methods. Using the RoboMet, fine lattice structures built with L-PBF have been characterized to determine the actual thicknesses of struts and density of the lattice structures. These structures have been used as finer build supports for the L-PBF process, designs for fine catalysts, and other design considerations for small components. The RoboMet data helps to inform the modeling and design efforts around these fine components.

additive manufacturing↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗