Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improving evapotranspiration computation with electrical resistivity tomography in a maize field

Abstract Hydrogeophysical methods have been increasingly used to study subsurface soil–water dynamics, yet their application beyond the soil compartment or the quantitative link to soil hydraulic properties remains limited. To examine how these methods can inform model‐based evapotranspiration (ET) calculation under varying soil water conditions, we conducted a pilot‐scale field study at an experimental maize plot with manipulated irrigation treatments. Our goal was to develop a workflow for (1) acquiring and inverting field electrical resistivity tomography (ERT) data, (2) correlating ERT to soil hydraulic properties, (3) spatially characterizing soil water stress that feeds into ET modeling (the FAO‐56 model), and (4) evaluating the performance of ERT‐based ET computation. Our results showed that ERT was able to capture decimeter‐scale soil water content (SWC) dynamics from root water uptake and irrigation manipulation and the contrast of soil water stress between deficiently and fully irrigated maize. We also demonstrated the flexibility of using ERT to spatially integrate soil water stress in the soil volume of interest, which could be adjusted based on different crops and plot layouts. The integration of the ERT datasets into ET modeling provided insights into the spatial heterogeneity of the subsurface that has been challenging for point‐based sensing, which can further our understanding of the hydraulic dynamics in the soil‐plant‐atmosphere continuum.

54 ENVIRONMENTAL SCIENCES↗

Toward Real-Time Analysis of Synchrotron Micro-Tomography Data: Accelerating Experimental Workflows with AI and HPC

ynchrotron light sources are routinely used to perform imaging experiments. In this paper, we review the relevant computational stages, identify bottlenecks, and highlight future opportunities to streamline data acquisition for experimental microscopy workflows. We demonstrate our preliminary exploration with an end-to-end scientific workflow on Summit based on micro-computed tomography data. Computational elements include: 1) reconstruction of volumetric image data; 2) denoising with deep neural networks; and 3) non-local means based segmentation and quantitative analysis.

Mcclure, James↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heterogeneous 3D Morphological Evolution of Ni Microparticles in Molten Salts: Visualized by Operando Synchrotron X-ray Nano-tomography

Ni-based superalloys are promising materials for high-temperature molten salt (MS) energy generation and storage. Studying morphological and chemical evolution of pure Ni in MS provides fundamental knowledge for MS technologies and corrosion mitigation. Here, in this study, real-time 3D morphological changes of Ni microparticles in molten KCl-MgCl 2 were studied by operando synchrotron X-ray nano-tomography at 700°C. Rapid Ni particle agglomeration occurred, without significant chemical reactions, such as oxide or chloride formation. The morphological growth evolved differently from classical coarsening or sintering behaviors and occurred nonuniformly, with other regions showing slight dissolution of Ni. Ni nanoparticles were found to be dispersed in many areas of the samples, either from microparticle dissolution or other radiation-induced nanoparticle formation mechanisms. This study discusses important factors, i.e., thermal gradient, amounts of salt and metals, and radiation effect, that influence morphological changes of materials in MS, critical for fundamental understanding of material–MS interactions as well as for practical applications.

36 MATERIALS SCIENCE↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

Anisotropic thermal diffusivity and conductivity in SiC/SiC tubes studied by infrared imaging and X-ray computed tomography

Traditional flash diffusivity evaluation of thermal diffusivity/conductivity of composite tubes require machining of specimens. For a thin-wall tube, this method can only be used to obtain through-thickness transport property. A novel method to evaluate anisotropic thermal diffusivity in a composite tube has been developed. Braided SiC/SiC composite tubes were subjected to a xenon flash heating pulse. A high-speed, high-sensitivity infrared camera was used to measure surface temperature changes as a function of time and nondestructively detect subsurface defects/damages, such as macroscopic pores. Standard reference material (Pyroceram 9606) and curved SiC/SiC composite tube specimens were used to validate thermal diffusivity obtained from infrared imaging. Unlike the traditional method, there is no need prepare special specimens, and thermal diffusivity values in three orientations are obtained after a single flash. A finite element analysis model based on x-ray computed tomography scans was developed to simulate the heat transfer. In conclusion, this technique is significant in assessing thermal conductivity and inspecting the health of ceramic tubes during and after service.

36 MATERIALS SCIENCE↗

Hydro-mechanical behavior of heated bentonite buffer for geologic disposal of high-level radioactive waste: A bench-scale X-ray computed tomography investigation

The behavior of heated bentonite buffer is critical for the security and long-term performance of a geological repository for high-level radioactive waste (HLW). While laboratory column experiments have been conducted to investigate compacted bentonite and coupled THMC (thermal-hydro-mechanical and chemical) processes for a moderate temperature range of up to 100 °C, data for a higher temperature range are limited. Understanding bentonite behavior and coupled THMC processes under higher temperatures (e.g., up to 200 °C) could allow for a more economic repository design and would expand the data and knowledge base for more reliable modeling. In this study, a bench-scale experiment was conducted in a compacted bentonite column experiencing both heating up to 200 °C in the center and hydration from a sand-clay boundary surrounding the column. During the experiment run for 1.5 years, frequent X-ray computed tomography (CT) scanning of bentonite provided insights into the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. After the experiment, a comprehensive post-dismantling characterization of bentonite samples was conducted. Results showed that the bentonite hydration was axi-symmetrical despite the initial heterogeneity due to packing, confirming the ability of bentonite to seal fast flow/transport paths. Further, compared to a non-heated control experiment, the heated column showed greater CT density variations along the radial distance, indicating that homogenization of bentonite might be more difficult if a temperature gradient is maintained in the repository. Precipitation of an anhydrite layer occurred in the inner hot zone, pointing to potential concerns about salt precipitation causing canister corrosion. Ultimately, the experiments provided a high-resolution window into the strongly dynamic and coupled behavior of bentonite exposed to heating, hydration and swelling, which will be valuable for improving modeling of coupled processes, especially for the early state of a HLW repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualitative and quantitative analysis of neutron irradiation effects in SiC/SiC composites using X-ray computed tomography

Silicon carbide fiber-reinforced silicon carbide matrix (SiC/SiC) composites are candidate materials for cladding of light water reactor (LWR) fuels. Loss of fission product gas retention due to the formation of microcrack networks is considered a potential failure mechanism for SiC/SiC-cladded fuels. In this work, a variety of SiC/SiC composite tubes were irradiated with and without an LWR-relevant radial heat flux in the High Flux Isotope Reactor, followed by detailed characterization with X-ray computed tomography (XCT). This first set of XCT data for neutron-irradiated samples confirmed that the internal stresses arising from a combination of temperature gradients and irradiation-induced swelling act as the primary driver for cracking. Consequently, while the observed cracking patterns varied depending on the tube architectures, the sharp edges of relatively large pores were found to be the common stress concentrator. These findings are useful to help improve the design and manufacturing of SiC/SiC fuel claddings for reduced failure probability.

42 ENGINEERING↗

Refined views of ancient ocean chemistry: Tracking trace element incorporation in pyrite framboids using atom probe tomography

The trace element chemistry of pyrite can be used to determine the origin, timing, and conditions of formation of ore deposits; as a vectoring tool for mineral exploration; and to determine the evolution of the Earth’s oceanic and atmospheric chemistry. However, little is known about whether trace elements are held with the pyrite structure or within nano-inclusions of other phases. This distinction is important for two primary reasons. First, trace element incorporation into the pyrite structure can affect the partitioning of other trace elements. Second, if trace elements are held within nano-inclusions, the partition coefficient of the mineral phases that make up the nano-inclusion, rather than pyrite, are the critical consideration in related interpretations. Previous studies addressing this topic have used laser ablation inductively coupled plasma mass spectrometry; however, the resulting data do not provide sufficient spatial resolution to delineate trace element distributions unless the inclusions are large. Further, they use these flat element profiles in time resolved laser ablation output graphs to argue that pyrite trace element content provides a direct relationship between trace element content of seawater and pyrite trace element content. To improve resolution, we have used atom probe tomography to characterize trace element distributions in pyrite framboids from the Cariaco Basin and Demerara Rise in three-dimensions at sub-nanometer resolution. Manganese was found to be concentrated in the pyrite nanocrystal part of the original framboid structure. In contrast, Ni was mostly found along the grain boundary, though it still appeared to be contained within the pyrite structure. Copper was concentrated in later pyrite overgrowths, and As varied in its location. These observations suggest that some important trace elements are incorporated into pyrite during early diagenesis, even in euxinic settings dominated by water-column pyrite formation. Statistical analysis was used to determine whether trace elements were incorporated in the lattice or within nanoscale inclusions (referred to here are nano-inclusions). We found that As, Ni, Cu, and Mn were commonly held within the pyrite structure, but As, Ni, and Cu can also be held as nano-inclusions or within grain interfaces. Incorporation of As is known to enhance the incorporation of other trace elements and in this case appears to correlated to elevated Ni and Cu concentrations in the Cariaco Basin samples. Furthermore, understanding these relationships strongly impacts our ability to utilize pyrite trace metal concentrations to analyze and quantify early ocean chemistry and its evolution through time.

54 ENVIRONMENTAL SCIENCES↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Unraveling the advances of trace doping engineering for potassium ion battery anodes via tomography

Doping have been considered as a prominent strategy to stabilize crystal structure of battery materials during the insertion and removal of alkali ions. The instructive knowledge and experience acquired from doping strategies predominate in cathode materials, but doping principle in anodes remains unclear. Here, we demonstrate that trace element doping enables stable conversion-reaction and ensures structural integrity for potassium ion battery (PIB) anodes. With a synergistic combination of X-ray tomography, structural probes, and charge reconfiguration, we encode the physical origins and structural evolution of electro-chemo-mechanical degradation in PIB anodes. By the multiple ion transport pathways created by the orderly hierarchical pores from “surface to bulk” and the homogeneous charge distribution governed in doped nanodomains, the anisotropic expansion can be significantly relieved with trace isoelectronic element doping into the host lattice, maintaining particle mechanical integrity. Our work presents a close relationship between doping chemistry and mechanical reliability, projecting a new pathway to reengineering electrode materials for next-generation energy storage.

25 ENERGY STORAGE↗

Method for measurement of TRISO kernel and layer volumes by X-ray computed tomography

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. In this study, image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.

36 MATERIALS SCIENCE↗

Atom Probe Tomography Characterization of High-Dose Ion Irradiated MA957

This paper presents a comprehensive characterization study of the microstructural responses to ion irradiation of the oxide dispersion strengthened (ODS) ferritic alloy MA957 using atom probe tomography (APT). The MA957 specimens were irradiated by 1.8 MeV Cr3+ ions to doses and temperatures relevant to advanced fast reactors (100 and 500 dpa at 400-500 °C). The average sizes of the YTiO particles decreased slightly after irradiation at all temperatures, with the most pronounced change at 400 °C. The particle number densities for 400 and 500 °C were slightly below number densities for the unirradiated condition, while the values were slightly higher at 420 and 450 °C. This behavior is consistent with the Nelson-Hudson-Mazey rate theory model that considers the competing effects between recombination and dissolution. An increase in the Y/Ti ratio of the YTiO particles was observed at the two lower temperatures. The formation of Cr-rich precipitates (a') was observed in specimens irradiated at temperatures up to 450 °C. Irradiation-induced segregation on grain boundaries was also investigated. Grain boundary element concentration profiles and ion maps demonstrate differences among the irradiation temperatures, with most datasets differing from the unirradiated condition. A key focus of this ion irradiation study is the high-dose response, and this quantitative assessment revealed relatively small but distinct effects of irradiation on microstructure evolution. Overall, these results showing minor second phase evolution suggest that MA957 should retain mechanical performance generally well up to 500 dpa for the irradiation temperatures studied.

Wang, Jing↗

Atom probe tomography characterization of ion and neutron irradiated Alloy 800H

Alloy 800H is a high temperature and creep resistant alloy, and is considered as a candidate alloy for use in Generation IV nuclear reactor systems. To clarify the alloy's behavior under irradiation, samples were subjected to single ion irradiations up to 20 dpa at 440°C, a dual ion/He irradiation to 17 dpa at 460°C, and a neutron irradiation to 17 dpa at 385°C. The irradiated microstructures were characterized using atom probe tomography to complement previously published transmission electron microscopy studies. Additionally, after single ion irradiation, sparse fine Al and Ti clusters were observed after 1dpa, while high number densities of nanoscale Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops developed after 10 and 20 dpa. The microstructure formed during single ion irradiation exhibited a strong depth dependence. No significant differences were observed between the single and dual ion irradiations. While Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops were also observed after neutron irradiation, the neutron-irradiated microstructure differed from those found in the ion-irradiated samples.

36 MATERIALS SCIENCE↗

Microstructure of irradiated AGR TRISO particle buffer layers as measured by X-ray computed tomography

Shrinkage of the initially low-density buffer layer in tristructural isotropic (TRISO) coated fuel particles during irradiation is a well-known phenomenon with potential implications for fission product and actinide transport, as well as potential pyrocarbon fracture that in some cases has been observed to impact particle performance. During post-irradiation examination, the buffer layer's structure is commonly determined using 2D microscopy of a particle cross section or a series of particle cross sections at staggered depths. Although these methods provide a general idea of the irradiated buffer microstructure, they do not provide a full picture of the TRISO coating microstructure. By contrast, x-ray computed tomography (XCT) provides full 3D imaging of the TRISO particle. Particles from various compacts irradiated for the Advanced Gas Reactor Fuel Development and Qualification Program were imaged using XCT. Some of these particles were selected because of abnormal fission product inventories (e.g., low 137 Cs), whereas others were randomly selected from the center of the fission product inventory distribution. Qualitative and quantitative analysis techniques were applied to the randomly selected particles as representatives of typical TRISO behavior to study the post-irradiation structure of the buffer layer. These results showed that, while separation of the buffer and inner pyrolytic carbon layers was a common behavior during the radiation-induced shrinkage of the buffer, a portion of the original buffer/inner pyrolytic carbon interface remained intact throughout irradiation in nearly all cases. Furthermore, these results also indicated clear trends in the degree of buffer densification with irradiation temperature and fluence.

36 MATERIALS SCIENCE↗