Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Effect of a Synchrotron X-ray Microtomography Imaging Experiment on the Amino Acid Content of a CM Chondrite

X-ray microcomputed tomography and synchrotron X-ray microcomputed tomography (μCT) are becoming popular tools for the reconnaissance imaging of chondrites. However, there are occasional concerns that the use of μCT may be detrimental to organic components of a chondrite. Soluble organic compounds represent ~2–10% of the total solvent extractable carbon in CI and CM carbonaceous chondrites and amino acids are among the most abundant compounds in the soluble organic fraction. We irradiated two samples of the Murchison CM2 carbonaceous chondrite under conditions slightly harsher (increased beam exposure time) than those typically used for x-ray μCT imaging experiments to determine if detectable changes in the amino acid abundance and distribution relative to a nonexposed control sample occurred. After subjecting two meteorite portions to ionizing radiation dosages of 1.1 kiloGray (kGy) and 1.2 kGy with 48.6 and 46.6 keV monochromatic X-rays, respectively, we analyzed the amino acid content of each sample. Within analytical errors, we found no differences in the amino acid abundances or enantiomeric ratios when comparing the control samples (nonexposed Murchison) and the irradiated samples. We show with calculations that any sample heating due to x-ray exposure is negligible. We conclude that a monochromatic synchrotron X-ray μCT experiment at beamline 13-BM-D of the Advanced Photon Source, which imparts ~1 kGy doses, has no detectable effect on the amino acid content of a carbonaceous chondrite. These results are important for the initial reconnaissance of returned samples from the OSIRIS-REx and Hayabusa 2 asteroid sample return missions.

Jon M. Friedrich↗

The NASA Open Science Data Repository: Biomedical Fair Data, Analysis Tools, User Communities, Publications, and Discoveries for Deep Space Missions

Increased biomedical risks and challenges associated with deep space missions require new knowledge discovery, new health countermeasures, and development of novel ecosystems, life support, crop production, and biomedical support capabilities. To meet NASA’s Moon to Mars strategic program goals for Human and Biological Sciences, findable, accessible, interoperable, reusable (FAIR), and maximally open-access data is going to be required to enable humanity to thrive in deep space. Indeed, this cornerstone perspective on FAIR and maximally open access data was also recommended in the recent 2023-2032 Decadal Survey from the National Academies of Sciences, Engineering, and Medicine. The NASA Open Science Data Repository (OSDR) is a maximally open access and FAIR database, and meets various scientific, technical, and operational spaceflight needs. It offers public users and submitters the ability to upload, download, search, share, analyze, and visualize data across ‘omics, physiological, phenotypic, behavioral, bioimaging, video, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive, and the NASA Biological Institutional Scientific Collection. OSDR has >455 studies with datasets from model organisms and non-NASA human astronauts. There are ~12 datasets from the Inspiration 4 (I4) mission, spanning metagenomics, comprehensive metabolic panels, clonal hematopoiesis, spatial transcriptomics, proteomics, and cytokine panels. In the interest of data privacy, two I4 datasets have raw FASTQ and FASTA files relating to the epitranscriptome, and a new request feature is live in OSDR (with a backend review process established) which was developed based on industry norms. OSDR also recently began a collaboration with the European Space Agency (ESA) to scientifically curate and make available >200 terabytes of human and model organism space-relevant data. The OSDR submission portal is designed to ingest and curate ~25 ‘omics assay data types, and ~50 physiological-phenotypic-imaging assay data types, spanning ultrasonography, micro-computed tomography, histology, morphometric photography, rebound tonometry, gait analysis, optical coherence tomography, novel object recognition, flow cytometry, and immunohistochemistry. A suite of analysis tools are available for OSDR users including: 1) an Environmental Data Application to compare radiation, CO2, relative humidity, temperature, and other telemetry across missions and subjects, 2) the RadLab database, a collaboration between NASA, ESA, the German and Italian Space Agencies, and the Bulgarian Academy of Sciences, which compiles radiation measurements relevant to human spaceflight and provides tools for accessing and manipulating the data, and 3) a Multi-study visualization tool which enables users to look across and combine GeneLab’s omics datasets across different experiments and missions. There are ~600 volunteer OSDR Analysis Working Group (AWG) members who: 1) provide feedback on scientific standards for reuse (subject and assay metadata; processing pipelines; dataset formats and uniformed structures for machine-readability), and 2) collaborate to mine-reuse OSDR data conducting scientific analysis. OSDR has enabled 60 publications as of September 2023, many directly from AWG collaborations most notably the Cell Press package in 2020. Lastly, there are at least 15 articles which mine OSDR data part of a package of ~50 articles across Nature Portfolio with research stemming from I4, the Japan Aerospace Exploration Agency, NASA Space Biology, and the NASA Human Research Program.

space biology↗

NASA Open Science Data Repository: Biomedical FAIR Data, Analysis Tools, User Communities, and Discoveries for Deep Space Missions

Increased biomedical risks and challenges associated with deep space missions require new knowledge discovery, new health countermeasures, and development of novel ecosystems, life support, crop production, and biomedical support capabilities. To meet NASA’s Moon to Mars strategic program goals for Human and Biological Sciences, findable, accessible, interoperable, reusable (FAIR), and maximally open-access data is going to be required to enable humanity to thrive in deep space. Indeed, this cornerstone perspective on FAIR and maximally open access data was also recommended in the recent 2023-2032 Decadal Survey from the National Academies of Sciences, Engineering, and Medicine. The NASA Open Science Data Repository (OSDR) is a maximally open access and FAIR database, and meets various scientific, technical, and operational spaceflight needs. It offers public users and submitters the ability to upload, download, search, share, analyze, and visualize data across ‘omics, physiological, phenotypic, behavioral, bioimaging, video, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive, and the NASA Biological Institutional Scientific Collection. OSDR has >455 studies with datasets from model organisms and non-NASA human astronauts. There are ~12 datasets from the Inspiration 4 (I4) mission, spanning metagenomics, comprehensive metabolic panels, clonal hematopoiesis, spatial transcriptomics, proteomics, and cytokine panels. In the interest of data privacy, two I4 datasets have raw FASTQ and FASTA files relating to the epitranscriptome, and a new request feature is live in OSDR (with a backend review process established) which was developed based on industry norms. OSDR also recently began a collaboration with the European Space Agency (ESA) to scientifically curate and make available >200 terabytes of human and model organism space-relevant data. The OSDR submission portal is designed to ingest and curate ~25 ‘omics assay data types, and ~50 physiological-phenotypic-imaging assay data types, spanning ultrasonography, micro-computed tomography, histology, morphometric photography, rebound tonometry, gait analysis, optical coherence tomography, novel object recognition, flow cytometry, and immunohistochemistry. A suite of analysis tools are available for OSDR users including: 1) an Environmental Data Application to compare radiation, CO2, relative humidity, temperature, and other telemetry across missions and subjects, 2) the RadLab database, a collaboration between NASA, ESA, the German and Italian Space Agencies, and the Bulgarian Academy of Sciences, which compiles radiation measurements relevant to human spaceflight and provides tools for accessing and manipulating the data, and 3) a Multi-study visualization tool which enables users to look across and combine GeneLab’s omics datasets across different experiments and missions. There are ~600 volunteer OSDR Analysis Working Group (AWG) members who: 1) provide feedback on scientific standards for reuse (subject and assay metadata; processing pipelines; dataset formats and uniformed structures for machine-readability), and 2) collaborate to mine-reuse OSDR data conducting scientific analysis. OSDR has enabled 60 publications as of September 2023, many directly from AWG collaborations most notably the Cell Press package in 2020. Lastly, there are at least 15 articles which mine OSDR data part of a package of ~50 articles across Nature Portfolio with research stemming from I4, the Japan Aerospace Exploration Agency, NASA Space Biology, and the NASA Human Research Program.

open access↗

Towards Quantifying and Correlating RTV Intumescence to Entry-Relevant Conditions

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also adopted to bond instrumentation plugs of temperature and pressure sensors into heatshield’s tiles. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Experimental data has also shown heating rate-dependent swelling (or intumescence) and shrinking of RTV, these volume changes may cause roughness-induced boundary layer transition. Outgassing and surface oxide formation of RTV upon decomposition also occur, which can be sources of contamination of heat shield sensors. This combination of detrimental effects motivates a critical need to develop a high-fidelity model for RTV ablation. As a first critical step in RTV modeling, a comprehensive material properties database for RTV was collected that account for the lack of data in properties such as pyrolysis char yield, shape change, virgin and char porosity. The next step is to quantify the volume change of RTV as a function of temperature. While this was done in previous campaigns, limited data was collected which showed a possible heating rate dependent intumescent behavior. To further understand the intumescence phenomenon of RTV, numerous dedicated experiments were performed at Beamline 8.3.2 of the Advanced Light Source, where RTV samples were heated while X-ray scans were taken in situ. Micro-Computed Tomography scans were taken in situ for low heating rates (≤ 60 °C/min), whereas continuous radiography scans were taken for higher heating rates (≤ 1500 ºC/min). Unconstrained samples and samples constrained in different holders (quartz, graphite, FiberForm and PICA) were tested to determine the change in intumescence due to confinement. Using deep learning techniques, the tomographies and radiographies are segmented to obtain volume change, porosity, pore size distributions and connectivity. From the results obtained, modifications to the previous RTV intumescence model are proposed, along with preliminary comparisons to testing RTV at high-enthalpy facilities.

RTV↗

Hindlimb unloading has a greater effect on cortical compared with cancellous bone in mature female rats

This study was designed to determine the effects of 28 days of hindlimb unloading (HU) on the mature female rat skeleton. In vivo proximal tibia bone mineral density and geometry of HU and cage control (CC) rats were measured with peripheral quantitative computed tomography (pQCT) on days 0 and 28. Postmortem pQCT, histomorphometry, and mechanical testing were performed on tibiae and femora. After 28 days, HU animals had significantly higher daily food consumption (+39%) and lower serum estradiol levels (-49%, P = 0.079) compared with CC. Proximal tibia bone mineral content and cortical bone area significantly declined over 28 days in HU animals (-4.0 and 4.8%, respectively), whereas total and cancellous bone mineral densities were unchanged. HU animals had lower cortical bone formation rates and mineralizing surface at tibial midshaft, whereas differences in similar properties were not detected in cancellous bone of the distal femur. These results suggest that cortical bone, rather than cancellous bone, is more prominently affected by unloading in skeletally mature retired breeder female rats.

NASA Discipline Musculoskeletal↗

Site- and compartment-specific changes in bone with hindlimb unloading in mature adult rats

The purpose of this study was to examine site- and compartment-specific changes in bone induced by hindlimb unloading (HU) in the mature adult male rat (6 months old). Tibiae, femora, and humeri were removed after 14, 21, and 28 days of HU for determination of bone mineral density (BMD) and geometry by peripheral quantitative computed tomography (pQCT), mechanical properties, and bone formation rate (BFR), and compared with baseline (0 day) and aging (28 day) controls. HU resulted in 20%-21% declines in cancellous BMD at the proximal tibia and femoral neck after 28 day HU vs. 0 day controls (CON). Cortical shell BMD at these sites was greater (by 4%-6%) in both 28 day HU and 28 day CON vs. 0 day CON animals, and nearly identical to that gain seen in the weight-bearing humerus. Mechanical properties at the proximal tibia exhibited a nonsignificant decline after HU vs. those of 0 day CON rats. At the femoral neck, a 10% decrement was noted in ultimate load in 28 day HU rats vs. 28 day CON animals. Middiaphyseal tibial bone increased slightly in density and area during HU; no differences in structural and material properties between 28 day HU and 28 day CON rats were noted. BFR at the tibial midshaft was significantly lower (by 90%) after 21 day HU vs. 0 day CON; this decline was maintained throughout 28 day HU. These results suggest there are compartment-specific differences in the mature adult skeletal response to hindlimb unloading, and that the major impact over 28 days of unloading is on cancellous bone sites. Given the sharp decline in BFR for midshaft cortical bone, it appears likely that deficits in BMD, area, or mechanical properties would develop with longer duration unloading.

Non-NASA Center↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Current methods and advances in bone densitometry

Bone mass is the primary, although not the only, determinant of fracture. Over the past few years a number of noninvasive techniques have been developed to more sensitively quantitate bone mass. These include single and dual photon absorptiometry (SPA and DPA), single and dual X-ray absorptiometry (SXA and DXA) and quantitative computed tomography (QCT). While differing in anatomic sites measured and in their estimates of precision, accuracy, and fracture discrimination, all of these methods provide clinically useful measurements of skeletal status. It is the intent of this review to discuss the pros and cons of these techniques and to present the new applications of ultrasound (US) and magnetic resonance (MRI) in the detection and management of osteoporosis.

Review, Academic↗

Electroencephalographic imaging of higher brain function

High temporal resolution is necessary to resolve the rapidly changing patterns of brain activity that underlie mental function. Electroencephalography (EEG) provides temporal resolution in the millisecond range. However, traditional EEG technology and practice provide insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. Recent advances help to overcome this problem by recording EEGs from more electrodes, by registering EEG data with anatomical images, and by correcting the distortion caused by volume conduction of EEG signals through the skull and scalp. In addition, statistical measurements of sub-second interdependences between EEG time-series recorded from different locations can help to generate hypotheses about the instantaneous functional networks that form between different cortical regions during perception, thought and action. Example applications are presented from studies of language, attention and working memory. Along with its unique ability to monitor brain function as people perform everyday activities in the real world, these advances make modern EEG an invaluable complement to other functional neuroimaging modalities.

Non-NASA Center↗

Synaptic changes in rat maculae in space and medical imaging: the link

Two different space life sciences missions (SLS-1 and SLS-2) have demonstrated that the synapses of the hair cells of rat vestibular maculae increase significantly in microgravity. The results also indicate that macular synapses are sensitive to stress. These findings argue that vestibular maculae exhibit neuroplasticity to macroenvironmental and microenvironmental changes. This capability should be clinically relevant to rehabilitative training and/or pharmacological treatments for vestibular disease. The results of this ultrastructural research also demonstrated that type I and type II hair cells are integrated into the same neuronal circuitry. The findings were the basis for development of three-dimensional reconstruction software to learn details of macular wiring. This software, produced for scientific research, has now been adapted to reconstruct the face and skull directly from computerized tomography scans. In collaboration with craniofacial reconstructive surgeons at Stanford University Medical Center, an effort is under way to produce a virtual environment workbench for complex craniofacial surgery. When completed, the workbench will help surgeons train for and simulate surgery. The methods are patient specific. This research illustrates the value of basic research in leading to unanticipated medical applications.

Flight Experiment↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Non-NASA Center↗

A two-year program of aerobics and weight training enhances bone mineral density of young women

Previous research suggests that physical activity may have a beneficial effect on bone mineral density (BMD) in women. This relationship was explored in a 2-year, randomized, intervention trial investigating the efficacy of exercise and calcium supplementation on increasing peak bone mass in young women. One hundred and twenty-seven subjects (ages of 20-35 years) were randomly assigned either to an exercise program that contained both aerobics and weight training components or to a stretching program. Calcium supplementation (up to 1500 mg/day including dietary intake) or placebo was given in a double-blinded design to all subjects. Spinal trabecular BMD was determined using quantitative computed tomography (QCT). Spinal integral, femoral neck, and trochanteric BMD were measured by dual X-ray absorptiometry (DXA) and calcaneal BMD by single photon absorptiometry (SPA). Fitness variables included maximal aerobic capacity (VO2max), and isokinetic muscle performance of the trunk and thigh. Measurements were made at baseline, 1 year, and 2 years. Sixty-three subjects (32 exercise, 31 stretching) completed the study, and all the measured bone parameters indicated a positive influence of the exercise intervention. There were significant positive differences in BMD between the exercise and stretching groups for spinal trabecular (2.5%), femoral neck (2.4%), femoral trochanteric (2.3%), and calcaneal (6.4%) measurements. The exercise group demonstrated a significant gain in BMD for spinal integral (1.3 +/- 2.8%, p < 0.02), femoral trochanteric (2.6 +/- 6.1%, p < 0.05), and calcaneal (5.6 +/- 5.1, p < 0.01) measurements. In contrast to exercise, the calcium intervention had no positive effect on any of the bone parameters. In regard to fitness parameters, the exercise group completed the study with significant gains in VO2max and isokinetic (peak torque) values for the knee flexion and extension and trunk extension. This study indicates that over a 2-year period, a combined regimen of aerobics and weight training has beneficial effects on BMD and fitness parameters in young women. However, the addition of daily calcium supplementation does not add significant benefit to the intervention.

Randomized Controlled Trial↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

The Effect of Experimental Variables on Industrial X-Ray Micro-Computed Sensitivity

A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.

X-ray Computed Tomography↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

Missing OH Reactivity in the Global Marine Boundary Layer

The hydroxyl radical (OH) reacts with thousands of chemical species in the atmosphere, initiating their removal and the chemical reaction sequences that produce ozone, secondary aerosols, and gas-phase acids. OH reactivity, which is the inverse of OH lifetime,influences the OH abundance and the ability of OH to cleanse the atmosphere. The NASA Atmospheric Tomography (ATom) campaign used instruments on the NASA DC-8 aircraft to measure OH reactivity and more than 100 trace chemical species. ATom presented a unique opportunity to test the completeness of the OH reactivity calculated from the chemical species measurements by comparing it to the measured OH reactivity over two oceans across four seasons. Although, throughout much of the free troposphere, the calculated OH reactivity was below the limit-of-detection for the ATom instrument used to measure OH reactivity, the instrument was able to measure the OH reactivity in and just above the marine boundary layer. The mean measured value of OH reactivity in the marine boundary layer across all latitudes and all ATom deployments was 1.9 s-1, which is 0.5 s-1larger than the mean calculated OH reactivity. The missing OH reactivity, the difference between the measured and calculated OH reactivity, varied between 0 s-1to 3.5 s-1, with the highest values over the Northern Hemisphere Pacific Ocean. Correlations of missing OH reactivity with formaldehyde, dimethyl sulfide, butanal, and sea surface temperature suggest the presence of unmeasured or unknown volatile organic compounds or oxygenated volatile organic compounds associated with ocean emissions.

NASA Atmospheric Tomography (ATom)↗