Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Systems, methods, and software for determining spatially variable distributions of the dielectric properties of a heterogeneous material

Systems, methods, and software for measuring the spatially variable relative dielectric permittivity of materials along a linear or otherwise configured sensor element, and more specifically the spatial variability of soil moisture in one dimension as inferred from the dielectric profile of the soil matrix surrounding a linear sensor element. Various methods provided herein combine advances in the processing of time domain reflectometry data with innovations in physical sensing apparatuses. These advancements enable high temporal (and thus spatial) resolution of electrical reflectance continuously along an insulated waveguide that is permanently emplaced in contact with adjacent soils. The spatially resolved reflectance is directly related to impedance changes along the waveguide that are dominated by electrical permittivity contrast due to variations in soil moisture. Various methods described herein are thus able to monitor soil moisture in profile with high spatial resolution.

36 MATERIALS SCIENCE↗

The design of double electrostatic-lens optics for resonance enhanced multiphoton ionization and photoelectron imaging experiments

Compared to single ion/electron-optics for velocity-map imaging, a double-focusing lens assembly designed not only allows for mapping velocity imaging of photoelectrons but also allows for investigating the vibrational structure of the intermediate states of neutral species in resonance enhanced multiphoton ionization (REMPI) spectra. In this presentation, in order to record REMPI and photoelectron spectra separately, we have constructed a compact photoelectron velocity-map imaging (VMI) apparatus combined with an opposite linear Wiley-Mclaren time-of-flight mass spectrometer (TOFMS). A mass resolution (m/Δm) of ∼1300 for TOFMS and electron energy resolution (ΔE/E) of 2.4% for VMI have been achieved upon three-photon ionization of Xe atom at 258.00 nm laser wavelength. As a benchmark, in combination of one-color (1 + 1) REMPI and photoelectron imaging of benzene via 6{sup 1} and 6{sup 1}1{sup 1} vibronic levels in the S{sub 1} state, the vibrational structures of the cation and photoelectron angular anisotropy are unraveled. In addition, two-color (1 + 1′) REMPI and photoelectron imaging of aniline was used to complete the accurate measurement of ionization potential (62 271 ± 3 cm{sup −1}). The results suggest that the apparatus is a powerful tool for studying photoionization dynamics in the photoelectron imaging using vibrational-state selected excitation to the intermediate states of neutrals based on REMPI technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detonation on a tabletop: Nitromethane with high time and space resolution

Nitromethane (NM), a flammable liquid, has been a model system for the shock-to-detonation transition in homogeneous condensed-phase explosives for over 50 years, but we do not understand the fast processes at the molecular scale in the detonation front at the molecular scale. That is largely because prior studies triggered detonations in bomb-sized charges with input shock durations and times-to detonation that were typically microseconds, which made it impossible to observe the faster processes in real time. Here, we studied NM shocked with 4 ns duration input pulses using a tabletop apparatus with laser-launched flyer plates and arrays of tiny disposable optical cuvettes, where the pressure and temperature were probed in real time (1 ns) with photon Doppler velocimetry, optical pyrometry, and high-speed video. Using a 4 ns shock with an input pressure close to the von Neumann spike pressure of 19 GPa, we achieved the minimum time-to-detonation, about 12 ns, where the time-to-detonation is controlled by fundamental molecular processes. We demonstrated the reproducibility of our detonations and showed that they had the same properties as in bomb-sized charges: our detonation velocity, von Neumann spike and Chapman-Jouguet pressures, temperatures, and reaction zone lengths were the same as in bomb-sized charges. Being able to trigger realistic reproducible detonations from a short pulse makes it possible to investigate molecular and fluid dynamics in the detonation by measuring transient responses in real time. Lastly, we found that it took 6 ns for the temperature to reach 3430 K. The high pressure was observed at about 8 ns, when there was a volume explosion to nearly twice the von Neumann spike pressure before settling down to a steady detonation .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An ultrafast angle-resolved photoemission apparatus for measuring complex materials

We present technical specifications for a high resolution time- and angle-resolved photoemission spectroscopy setup based on a hemispherical electron analyzer and cavity-dumped solid state Ti:sapphire laser used to generate pump and probe beams, respectively, at 1.48 and 5.93 eV. The pulse repetition rate can be tuned from 209 Hz to 54.3 MHz. Under typical operating settings the system has an overall energy resolution of 23 meV, an overall momentum resolution of 0.003 A{sup -1}, and an overall time resolution of 310 fs. We illustrate the system capabilities with representative data on the cuprate superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}. The descriptions and analyses presented here will inform new developments in ultrafast electron spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

25 ENERGY STORAGE↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

Christophersen, Jon P.↗

Exploring Low Energy Molecular Ion Reactions With Merged Beams

Charge transfer (CT) in molecular ion-neutral interactions can proceed through dynamically coupled electronic, vibrational, and rotational degrees of freedom. Using the upgraded Oak Ridge National Laboratory ion-atom merged-beams apparatus, absolute direct charge transfer is explored from keV/u collision energies where the collision is considered ''ro-vibrationally frozen'' to sub-eV/u collision energies where collision times are long enough to sample vibrational and rotational modes. Our first molecular ion measurement with the merged-beams apparatus has been performed for D{sub 2}{sup +}+H and is used to benchmark high energy sudden approximation theory and vibrational specific adiabatic theory for the (H{sub 2}-H){sup +} complex. CT measurements have also been performed for D{sub 3}{sup +}+H from 2 eV/u to 2 keV/u and CO{sup +}+D from 20 eV/u to 2000 eV/u. With straightforward improvements to the apparatus, we plan to extend our measurements to key ''destructive'' rate coefficients for H{sub 2}{sup +} and CH{sup +} with H at temperatures relevant to the interstellar medium.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rotating launch device for a remotely piloted aircraft

A method and apparatus for launching a remotely piloted aircraft is disclosed, wherein the aircraft is revolved about a fixed pivot point until a predetermined speed is reached whereupon the vehicle is released from the launching apparatus. The vehicle is attached to one end of a rotatable arm, the imbalance on the arm being counteracted by a counter weight attached to the opposite end. The counter weight is released from the arm at the same time as the aircraft so as to avoid structural damage to the apparatus caused by rotation in the unbalanced condition. The arm is oriented such that it rotates in a plane inclined obliquely to the local gravitational field of the launch site.

Gregory, T. J.↗

aCORN: An experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Apparatus and method for optimizing quantifiable behavior in configurable devices and systems

An apparatus and method are provided to perform constrained optimization of a constrained property of an apparatus, which is complex due to having several components, and these components are configurable in real-time. The optimization is achieved by detecting values of the constrained property and a plurality of other properties of the apparatus when the apparatus is configured in a first subset of the plurality of configurations. A model is learned using the detected values of the constrained property. The model represents the constrained property and can also represent other properties as a function of the configurations. The model can also include estimated uncertainties of the constrained property in the model. Then, using the d model and the estimated uncertainties, the optimal configuration can be selected to minimize an error value (e.g., the difference between a desired value and an observed value of the at least one constrained property).

Hoffmann, Henry↗

Autoignition characteristics of aircraft-type fuels

The ignition delay characteristics of Jet A, JP 4, no. 2 diesel, cetane and an experimental referee broad specification (ERBS) fuel in air at inlet temperatures up to 1000 K, pressures of 10, 15, 20, 25 and 30 atm, and fuel air equivalence ratios of 0.3, 0.5, 0.7 and 1.0 were mapped. Ignition delay times in the range of 1 to 50 msec at freestream flow velocities ranging from 20 to 100 m/sec were obtained using a continuous flow test apparatus which permitted independent variation and evaluation of the effect of temperature, pressure, flow rate, and fuel/air ratio. The ignition delay times for all fuels tested appeared to correlate with the inverse of pressure and the inverse exponent of temperature. With the exception of pure cetane, which had the shortest ignition delay times, the differences between the fuels tested did not appear to be significant. The apparent global activation energies for the typical gas turbine fuels ranged from 38 to 40 kcal/mole, while the activation energy determined for cetane was 50 kcal/mole. In addition, the data indicate that for lean mixtures, ignition delay times decrease with increasing equivalence ratio. It was also noted that physical (apparatus dependent) phenomena, such as mixing (i.e., length and number of injection sites) and airstream cooling (due to fuel heating, vaporization and convective heat loss) can have an important effect on the ignition delay.

Spadaccini, L. J.↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contour Detector and Data Acquisition System for the Left Ventricular Outline

A real-time contour detector and data acquisition system is described for an angiographic apparatus having a video scanner for converting an X-ray image of a structure characterized by a change in brightness level compared with its surrounding into video format and displaying the X-ray image in recurring video fields. The real-time contour detector and data acqusition system includes track and hold circuits; a reference level analog computer circuit; an analog compartor; a digital processor; a field memory; and a computer interface.

Reiber, J. H. C.↗

Experiment-to-Experiment Disturbance of Microgravity Environment

The STS-87 Shuttle mission carried the Fourth United States MicroGravity Payload (USMP-4) as one of the primary payloads. Four USMP-4 science experiments were installed on two carriers in the cargo bay of the Shuttle. The Confined Helium Experiment (CHeX), located on the aft carrier, was particularly susceptible to vibrations in several frequency ranges due to structural resonances of the CHeX apparatus and the extreme sensitivity of the sample to vibrations. Shortly after activation of the USMP-4 payload, a strong, vibratory disturbance within the susceptibility region of the CHeX apparatus was detected. After investigating the characteristics of the disturbance and the time at which it first appeared, it was deduced that the vibration was generated by cooling fans in the Isothermal Dendritic Growth Experiment (IDGE). This paper will summarize the development of the conflict, briefly describe the disturbance source, and the susceptibility of the CHeX apparatus, and summarize the results of post-mission tests of IDGE.

DeLombard, Richard↗

Signal processing in ultrasound

Signal is the term used to denote the characteristic in the time or frequency domain of the probing energy of the system. Processing of this signal in diagnostic ultrasound occurs as the signal travels through the ultrasonic and electrical sections of the apparatus. The paper discusses current signal processing methods, postreception processing, display devices, real-time imaging, and quantitative measurements in noninvasive cardiology. The possibility of using deconvolution in a single transducer system is examined, and some future developments using digital techniques are outlined.

Le Croissette, D. H.↗

Spontaneous ignition delay characteristics of hydrocarbon fuel-air mixtures

The influence of pressure on the autoignition characteristics of homogeneous mixtures of hydrocarbon fuels in air is examined. Autoignition delay times are measured for propane, ethylene, methane, and acetylene in a continuous flow apparatus featuring a multi-point fuel injector. Results are presented for mixture temperatures from 670K to 1020K, pressures from 1 to 10 atmospheres, equivalence ratios from 0.2 to 0.7, and velocities from 5 to 30 m/s. Delay time is related to pressure, temperature, and fuel concentration by global reaction theory. The results show variations in global activation energy from 25 to 38 kcal/kg-mol, pressure exponents from 0.66 to 1.21, and fuel concentration exponents from 0.19 to 0.75 for the fuels studied. These results are generally in good agreement with previous studies carried out under similar conditions.

Lefebvre, A. H.↗

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE↗

Moisture Outgassing Rates from TATB-Formulations: Experiments and Kinetic Model Development

Moisture outgassing rates from materials are of interest and importance to a variety of different fields. Because water can attack and accelerate decomposition, aging, or rusting of various parts, the assembly of an apparatus with 'wet' materials can shorten the lifetime of the apparatus. Outgassing of moisture from materials can be quite slow and a material that is seemingly dry at the time of assembly may slowly release water over years. This slow release of water will compromise the other constituents of the apparatus (e.g. electrical components, metals, organic materials) and shorten the lifetime of the apparatus. For apparatuses that are expensive or laborious to construct, it is especially important to understand and be able to predict the mechanisms and rates of water release from various materials. Such an understanding can support the development of accurate estimates of the apparatus's serviceable age and may allow for mitigation strategies in order to protect other parts from water. Energetic materials such as TATB based PBX-9502 (95% TATB, 5% Kel-F 800) and LX-17 (92.5% TATB and 7.5% Kel-F) pose a particularly challenging problem because they are heterogeneous materials with potentially many different sources and mechanisms of water release. Water molecules could be adsorbed into the polymeric binder matrix, trapped in occlusions within the polymer and the TATB crystals/particles, or trapped within defect sites in the TATB crystal. Finally, many studies indicate that water is a decomposition product under rapid heating conditions, at high temperatures and/or high pressure. Previous studies have measured the water release rate(s) from LX-17 or PBX-9502 prill/powder in order to establish oven drying times prior to use. These studies limited their time frame to a few days or a week of drying. Other studies have looked at the rate of water release of large pressed parts contained in sealed containers. Finally, some studies have looked at the rate of water diffusion through pressed parts, or the effects of wet vs. dry machining, or the influence of the synthesis methods in the amount of water present. There are a few different models that have been developed to predict the rate of water release from LX-17 or PBX-9502. These models are, to some extent, limited by the limitations of the experiments. Because all these experiments looked at water release over a relatively short period of time and left the samples relatively undamaged, they serve as a lower bound. In this work, we perform experiments and develop models that can serve as an upper bound on the rate and amount of water that can be released. Our experimental approach is to use temperature programmed desorption (TPD) and monitor the rate and amount of water release as a function of temperature. We analyzed our experimental data using two different kinetic analysis methods (isoconversional analysis and nth-order Arrhenius kinetic fits) and used the results to make predictions. The suitability of these kinetic analysis methods as well as the applicability of these experiments to long term aging (e.g. years) issues are discussed. Using the kinetics from our experiments, we predict the water release at temperature and timescales relevant to the existing literature. Based on our analysis and comparison with older data, the kinetic model(s) developed in this work serve as a relatively accurate (i.e. order of magnitude) method for predicting the water release under a variety of thermal histories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗