Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Frequency bandwidth and conversion loss of a semiconductor heterodyne receiver with phonon cooling of two-dimensional electrons

The temperature and concentration dependences of the frequency bandwidth of terahertz heterodyne AlGaAs/GaAs detectors based on hot electron phenomena with phonon cooling of two-dimensional electrons have been measured by submillimeter spectroscopy with a high time resolution. At a temperature of 4.2 K, the frequency bandwidth at a level of 3 dB (f{sub 3dB}) is varied from 150 to 250 MHz with a change in the concentration n{sub s} according to the power law f{sub 3dB} {proportional_to} n{sub s}{sup -0.5} due to the dominant contribution of piezoelectric phonon scattering. The minimum conversion loss of the semiconductor heterodyne detector is obtained in structures with a high carrier mobility ({mu} > 3 x 10{sup 5} cm{sup 2} V{sup -1} s{sup -1} at 4.2 K).

36 MATERIALS SCIENCE↗

Skylab ATM/S-056 X-ray event analyzer: Instrument description, parameter determination, and analysis example (15 June 1973 1B/M3 flare)

The Skylab ATM/S-056 X-Ray Event Analyzer, part of an X-ray telescope experiment, is described. The techniques employed in the analysis of its data to determine electron temperatures and emission measures are reviewed. The analysis of a sample event - the 15 June 1973 1B/M3 flare - is performed. Comparison of the X-Ray Event Analyzer data with that of the SolRad 9 observations indicates that the X-Ray Event Analyzer accurately monitored the sun's 2.5 to 7.25 A X-ray emission and to a lesser extent the 6.1 to 20 A emission. A mean average peak temperature of 15 million K at 1,412 UT and a mean average peak electron density (assuming a flare volume of 10 to the 13 power cu km) of 27 million/cu mm at 1,416 to 1,417 UT are deduced for the event. The X-Ray Event Analyzer data, having a 2.5 s time resolution, should be invaluable in comparisons with other high-time resolution data (e.g., radio bursts).

Wilson, R. M.↗

A novel compact high speed x-ray streak camera (invited)

Conventional in-line high speed streak cameras have fundamental issues when their performance is extended below a picosecond. The transit time spread caused by both the spread in the photoelectron (PE) ''birth'' energy and space charge effects causes significant electron pulse broadening along the axis of the streak camera and limits the time resolution. Also it is difficult to generate a sufficiently large sweep speed. This paper describes a new instrument in which the extraction electrostatic field at the photocathode increases with time, converting time to PE energy. A uniform magnetic field is used to measure the PE energy, and thus time, and also focuses in one dimension. Design calculations are presented for the factors limiting the time resolution. With our design, subpicosecond resolution with high dynamic range is expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of electron path lengths observed in the highly wound outer region of magnetic clouds with the slab fraction of magnetic turbulence in the dissipation range

Three magnetic cloud events, in which solar impulsive electron events occurred in their outer region, are employed to investigate the difference of path lengths L {sub 0eIII} traveled by non-relativistic electrons from their release site near the Sun to the observer at 1 AU, where L {sub 0eIII} = v {sub l} × (t {sub l} – t {sub III}), v {sub l} and t {sub l} being the velocity and arrival time of electrons in the lowest energy channel (∼27 keV) of the Wind/3DP/SST sensor, respectively, and t {sub III} being the onset time of type III radio bursts. The deduced L {sub 0eIII} value ranges from 1.3 to 3.3 AU. Since a negligible interplanetary scattering level can be seen in both L {sub 0eIII} > 3 AU and ∼1.2 AU events, the difference in L {sub 0eIII} could be linked to the turbulence geometry (slab or two-dimensional) in the solar wind. By using the Wind/MFI magnetic field data with a time resolution of 92 ms, we examine the turbulence geometry in the dissipation range. In our examination, ∼6 minutes of sampled subintervals are used in order to improve time resolution. We have found that, in the transverse turbulence, the observed slab fraction is increased with an increasing L {sub 0eIII} value, reaching ∼100% in the L {sub 0eIII} > 3 AU event. Our observation implies that when only the slab spectral component exists, magnetic flux tubes (magnetic surfaces) are closed and regular for a very long distance along the transport route of particles.

79 ASTRONOMY AND ASTROPHYSICS↗

On the role of last closed drift shell dynamics in driving fast losses and Van Allen radiation belt extinction

We present observations of very fast radiation belt loss as resolved using high time resolution electron flux data from the constellation of Global Positioning System (GPS) satellites. The time scale of these losses is revealed to be as short as ~0.5–2 hr during intense magnetic storms, with some storms demonstrating almost total loss on these time scales and which we characterize as radiation belt extinction. The intense March 2013 and March 2015 storms both show such fast extinction, with a rapid recovery, while the September 2014 storm shows fast extinction but no recovery for around 2 weeks. By contrast, the moderate September 2012 storm which generated a three radiation belt morphology shows more gradual loss. Here, we compute the last closed drift shell (LCDS) for each of these four storms and show a very strong correspondence between the LCDS and the loss patterns of trapped electrons in each storm. Most significantly, the location of the LCDS closely mirrors the high time resolution losses observed in GPS flux. The fast losses occur on a time scale shorter than the Van Allen Probes orbital period, are explained by proximity to the LCDS, and progress inward, consistent with outward transport to the LCDS by fast ultralow frequency wave radial diffusion. Expressing the location of the LCDS in L*, and not model magnetopause standoff distance in units of RE, clearly reveals magnetopause shadowing as the cause of the fast loss observed by the GPS satellites.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ high-energy synchrotron radiation study of boehmite formation, growth, and phase transformation to alumina in sub- and supercritical water.

Boehmite (AlOOH) nanoparticles have been synthesized in subcritical (300 bar, 350 C) and supercritical (300 bar, 400 C) water. The formation and growth of AlOOH nanoparticles were studied in situ by small- and wide-angle X-ray scattering (SAXS and WAXS) using 80 keV synchrotron radiation. The SAXS/WAXS data were measured simultaneously with a time resolution greater than 10 s and revealed the initial nucleation of amorphous particles takes place within 10 s with subsequent crystallization after 30 s. No diffraction signals were observed from Al(OH){sub 3} within the time resolution of the experiment, which shows that the dehydration step of the reaction is fast and the hydrolysis step rate-determining. The sizes of the crystalline particles were determined as a function of time. The overall size evolution patterns are similar in sub- and supercritical water, but the growth is faster and the final particle size larger under supercritical conditions. After approximately 5 min, the rate of particle growth decreases in both sub- and supercritical water. Heating of the boehmite nanoparticle suspension allowed an in situ X-ray investigation of the phase transformation of boehmite to aluminium oxide. Under the wet conditions used in this work, the transition starts at 530 C and gives a two-phase product of hydrated and non-hydrated aluminium oxide.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Semi-Continuous Measurement of PM2.5 Ionic Composition at Several Rural Locations in the United States

To improve understanding of the nature and variability of the ionic fraction of atmospheric fine aerosol particles in non-urban environments, one to two month measurement campaigns were conducted at several rural locations in the United States. Study sites included Yosemite National Park (NP) (July – September 2002), Bondville, Illinois (February 2003), San Gorgonio Wilderness Area, California (April and July 2003), Grand Canyon NP, Arizona (May 2003), Brigantine National Wildlife Refuge (NWR), New Jersey (November 2003), and Great Smoky Mountains NP, Tennessee (July/August 2004). PM2.5 ion composition was measured at 15-minute intervals using a Particle Into Liquid Sampler (PILS) coupled to two ion chromatographs. Comparison of PILS measurements with parallel traditional 24-hr denuder/filter-pack measurements reveal generally good agreement between the two techniques, although PILS measurements of PM2.5 NH4+ appear to be biased slightly low. High-time resolution aerosol concentration measurements provide much better estimates of the range of aerosol concentration levels experienced at these rural locations. Ratios of peak 15-min to 24-hr nitrate concentrations, for example, ranged from 1.7 at Brigantine NWR to 7.0 at the Great Smoky Mountains NP. A strong influence of diurnal upslope/downslope transport patterns was observed on aerosol concentrations at several locations, including Yosemite NP, San Gorgonio Wilderness Area, and Great Smoky Mountains NP, with peak concentrations typically occurring during afternoon upslope transport. High time resolution aerosol composition measurements also provide new insight into relationships between individual aerosol species and the influence of environmental conditions on aerosol composition. Observations at several locations revealed important information about mechanisms of particle nitrate formation. At Yosemite and Grand Canyon NPs, for example, evidence was observed for reaction of nitric acid or its precursors with sea salt or soil dust. Observations from several sites also revealed the importance of aerosol acidity (Great Smoky Mountains NP, Bondville) and temperature/humidity (San Gorgonio, Bondville) on fine particle ammonium nitrate formation.

54 ENVIRONMENTAL SCIENCES↗

Investigation of cosmic rays in very short time scales

A fast databuffer system, where cosmic ray events in the Turku hadron spectrometer, including particle arrival times are recorded with time resolution of 100 ns was constructed. The databuffer can be read continuously by a microprocessor, which preanalyzes the data and transfers it to the main computer. The time span, that can be analyzed in every detail, is a few seconds. The high time resolution enables a study of time correlated groups of high energy particles. In addition the operational characteristics of the spectrometer can be monitored in detail.

Peltonen, J.↗

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Communication Boundaries of Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy resources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for successful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Observations of the 3-D distribution of interplanetary electrons and ions from solar wind plasma to low energy cosmic rays

The 3-D Plasma and Energetic Particle instrument on the GGS Wind spacecraft (launched November 1, 1994) is designed to make measurements of the full three-dimensional distribution of suprathermal electrons and ions from solar wind plasma to low energy cosmic rays, with high sensitivity, wide dynamic range, good energy and angular resolution, and high time resolution. Three pairs of double-ended telescopes, each with two or three closely sandwiched passivated ion implanted silicon detectors measure electrons and ions from approximately 20 keV to greater than or equal to 300 keV. Four top-hat symmetrical spherical section electrostatic analyzers with microchannel plate detectors, a large and a small geometric factor analyzer for electrons and a similar pair for ions, cover from approximately 3 eV to 30 keV. We present preliminary observations of the electron and ion distributions in the absence of obvious solar impulsive events and upstream particles. The quiet time electron energy spectrum shows a smooth approximately power law fall-off extending from the halo population at a few hundred eV to well above approximately 100 keV The quiet time ion energy spectrum also shows significant fluxes over this energy range. Detailed 3-D distributions and their temporal variations will be presented.

Lin, R. P.↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy re-sources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for suc-cessful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly de-veloped DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS): Preprint

As the coordination of distributed energy resources (DERs) becomes more necessary to provide grid services through a distributed energy resources management system (DERMS), studying the communication requirements for successful real-world low-cost implementation becomes increasingly important. Specifically, this paper studies the needed communication time resolutions between the different system components for a primal-dual based DERMS which is a highly-developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗