Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Data Assimilation Experiments Using Quality Controlled AIRS Version 5 Temperature Soundings

The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains a number of significant improvements over Version 4. Two very significant improvements are described briefly below. 1) The AIRS Science Team Radiative Transfer Algorithm (RTA) has now been upgraded to accurately account for effects of non-local thermodynamic equilibrium on the AIRS observations. This allows for use of AIRS observations in the entire 4.3 micron CO2 absorption band in the retrieval algorithm during both day and night. Following theoretical considerations, tropospheric temperature profile information is obtained almost exclusively from clear column radiances in the 4.3 micron CO2 band in the AIRS Version 5 temperature profile retrieval step. These clear column radiances are a derived product that are indicative of radiances AIRS channels would have seen if the field of view were completely clear. Clear column radiances for all channels are determined using tropospheric sounding 15 micron CO2 observations. This approach allows for the generation of accurate values of clear column radiances and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by-channel clear column radiances. These error estimates are used for quality control of the retrieved products. Based on error estimate thresholds, each temperature profiles is assigned a characteristic pressure, pg, down to which the profile is characterized as good for use for data assimilation purposes. We have conducted forecast impact experiments assimilating AIRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM, at a spatial resolution of 0.5 deg by 0.5 deg. Assimilation of Quality Controlled AIRS temperature profiles down to pg resulted in significantly improved forecast skill compared to that obtained from experiments when all data used operationally by NCEP, except for AIRS data, is assimilated. These forecasts were also significantly better than to those obtained when AIRS radiances (rather than temperature profiles) are assimilated, which is the way AIRS data is used operationally by NCEP and ECMWF.

Susskind, Joel↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Velocity profile shapes in Alcator C-Mod plasmas

Abstract Toroidal rotation velocity spatial profiles ( r / a < 0.8) have been obtained from C-Mod over a wide range of operational conditions, including H-mode, I-mode, ICRF-heated L-mode and Ohmic L-mode (LOC and SOC), and in plasmas with ITBs, LH wave injection and MCFD. Peaked, flat and hollow rotation profiles have been observed. In H- and I-mode plasmas, generally with co-current peaked profiles, the peaking is correlated with temperature profile peaking, and both increase with toroidal magnetic field (decrease with ρ ∗ ). Any dependence on density peaking is unclear. For Ohmic L-mode discharges, with LOC, the velocity profiles are usually flat and most often directed co-current, while with SOC the profiles are hollow, mostly co-current at the edge and counter-current in the core. Both of these Ohmic rotation states exist with matched density and temperature profiles (and gradients), indicating that neither gradient is relevant during rotation reversals. For plasmas with LH wave injection and discharges with ITBs, the velocity profiles are hollow while the density and temperature profiles exhibit substantial peaking. Broadly speaking for all operational regimes, there is no unifying ordering of the velocity gradient with plasma parameters.

Rice, J. E. (ORCID:0000000183195971)↗

Modeling the effect of lithium-induced pedestal profiles on scrape-off-layer turbulence and the heat flux width

The effect of lithium (Li) wall coatings on scrape-off-layer (SOL) turbulence in the National Spherical Torus Experiment (NSTX) is modeled with the Lodestar SOLT (SOL Turbulence) code. Specifically, the implications for the SOL heat flux width of experimentally observed, Li-induced changes in the pedestal profiles are considered. The SOLT code used in the modeling has been expanded recently to include ion temperature evolution and ion diamagnetic drift effects. This work focuses on two NSTX discharges occurring pre- and with-Li deposition. The simulation density and temperature profiles are constrained, inside the last closed flux surface only, to match those measured in the two experiments, and the resulting drift-interchange-driven turbulence is explored. The effect of Li enters the simulation only through the pedestal profile constraint: Li modifies the experimental density and temperature profiles in the pedestal, and these profiles affect the simulated SOL turbulence. The power entering the SOL measured in the experiments is matched in the simulations by adjusting “free” dissipation parameters (e.g., diffusion coefficients) that are not measured directly in the experiments. With power-matching, (a) the heat flux SOL width is smaller, as observed experimentally by infrared thermography and (b) the simulated density fluctuation amplitudes are reduced with Li, as inferred for the experiments as well from reflectometry analysis. The instabilities and saturation mechanisms that underlie the SOLT model equilibria are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Sampling-Probe Distorted Temperature Fields with X-Ray Fluorescence Spectroscopy

Flame-sampling experiments, especially in conjunction with laminar low-pressure premixed flames, are routinely used in combustion chemistry studies to unravel the identities and quantities of key intermediates and their pathways. In many instances, however, an unambiguous interpretation of the experimental and modeling results is hampered by the uncertainties about the probe-induced, perturbed temperature profile. To overcome this limitation, two-dimensional perturbations of the temperature field caused by sampling probes with different geometries have been investigated using synchrotron-based X-ray fluorescence spectroscopy. In these experiments, which were performed at the 7-BM beamline of the Advanced Photon Source (APS) at the Argonne National Laboratory, a continuous beam of hard X-rays at 15 keV was used to excite krypton atoms that were added in a concentration of 5 vol.-% to the unburnt gas mixture and the resulting krypton fluorescence at 12.65 keV was subsequently collected. The highly spatially resolved signal was converted into the local flame temperature to obtain temperature fields at various burner-probe separations as functions of the distance to the burner surface and the radial distance from the centerline. Multiple measurements were performed with different probe geometries and because of the observed impact on the temperature profiles the results clearly revealed the need to specify the sampling probe design to enable quantitative and meaningful comparisons of modeling results with flame-sampled mole fraction data. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Hansen, N.↗

Acoustic propagation in a thermally stratified atmosphere

Acoustic propagation in an atmosphere with a specific form of temperature profile has been investigated by analytical means. The temperature profile used is representative of an actual atmospheric profile and contains three free parameters. Both lapse and inversion cases have been considered. Although ray solution have been considered the primary emphasis has been on solutions of the acoustic wave equation with point force where the sound speed varies with height above the ground corresponding to the assumed temperature profile. The method used to obtain the solution of the wave equation is based on Hankel transformation of the wave equation, approximate solution of the transformed equation for wavelength small compared to the scale of the temperature (or sound speed) profile, and approximate or numerical inversion of the Hankel transformed solution. The solution displays the characteristics found in experimental data but extensive comparison between the models and experimental data has not been carried out.

Vanmoorhem, W. K.↗

Acoustic propagation in a thermally stratified atmosphere

Acoustic propagation in an atmosphere with a specific form of a temperature profile has been investigated by analytical means. The temperature profile used is representative of an actual atmospheric profile and contains three free parameters. Both lapse and inversion cases have been considered. Although ray solutions have been considered, the primary emphasis has been on solutions of the acoustic wave equation with point source where the sound speed varies with height above the ground corresponding to the assumed temperature profile. The method used to obtain the solution of the wave equation is based on Hankel transformation of the wave equation, approximate solution of the transformed equation for wavelength small compared to the scale of the temperature (or sound speed) profile, and approximate or numerical inversion of the Hankel transformed solution. The solution displays the characteristics found in experimental data but extensive comparison between the models and experimental data has not been carried out.

Vanmoorhem, W. K.↗

Temperature sensitivity of the equilibrium neutronics and accident analysis of the HTR-10

Pebble-Bed High-Temperature Gas-cooled Reactors (PB-HTGR) are moderated by the graphite in the fuel pebbles and the graphite reflector surrounding the pebble-bed. Because graphite is by far the most abundant material in PB-HTGRs and the primary moderator, accurate modeling of the graphite material, including density, impurities, and temperatures, is crucial for accurate computational modeling and simulation of these reactors. While main characteristics of the graphite components are often known, the local temperature is less well known and often averaged over all components. Here, this work studies the impact of considering accurate temperature profiles in the graphite material on the generation of a small PB-HTGR model at the state of equilibrium operation and on short-term accident progression. The fuel compositions for the PB-HTGR were determined using a jump-in equilibrium modeling method, the Axial Radial Zone Equilibrium Modeling (AR-ZEM) method. In contrast to previous work, the AR-ZEM method was used considering thermal-hydraulic feedback from the MELCOR code to determine temperatures of the fuel pebbles and the surrounding graphite reflector. The consideration of an axial and radial temperature profile in the core and reflector, as opposed to uniform material temperatures, had an impact of almost 1,300 pcm on the equilibrium core eigenvalue and caused significant differences in the discharged plutonium fuel inventory with up to 4.9% and 11.0% for Pu-239 and Pu-242, respectively. To assess the impact on short-term accident progression, two Anticipated Transient Without SCRAM (ATWS) events, a Pressurized Loss of Forced Coolant (PLOFC) and a Control Rod Withdrawal (CRW) with loss of flow, were simulated with MELCOR. The use of temperature profiles in the equilibrium core models did not reveal a significant impact on the temperature, power, or reactivity responses during the transients. In conclusion, a need for consideration of accurate temperature profiles, in particular for the graphite reflector, was found for the generation of equilibrium PB-HTGRs core models using jump-in methods, but detailed temperature profiles may not be necessary when performing conservative transient analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Helium-Like Iron Line Temperature Diagnostics in Clusters of Galaxies

The emission complex around 6.7 keV, arising from He-like Fe lines and their dielectronic satellites, has been observed at low resolution in a number of clusters of galaxies. With sufficient spectral resolution as in, e.g., solar flare observations, the ratio, G = (x + y + z)/w, of the intercombination (x and y) and forbidden (z) to the resonance (w) lines arising from the n = 2 level of the He-like ion, is a sensitive temperature diagnostic. We examine this role for G in the context of spatially and spectrally resolved observations of clusters of galaxies. The temperature behavior of this ratio is strongly dependent on the spectral resolution. We introduce an alternative definition for G that includes the contribution of satellite lines and improves the temperature fidelity of this diagnostic. We find that deprojection of the observed value of G along a line of sight through the cluster can yield accurate temperature profiles for temperatures in the range 10(exp 7)-10(exp 8) K that do not suffer from the cluster model uncertainties inherent in deconvolution of broad-band X-ray surface brightness profiles.

Swartz, Douglas A.↗

Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy

The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.

Edwards, Lawrence G.↗

Probing WHIM around galaxy clusters with fast radio bursts and the Sunyaev–Zel’dovich effect

We propose a new method to probe the warm hot intergalactic medium (WHIM) beyond the virial radius (R{sub 200}) of a cluster of galaxies, where X-ray observations are not easily achievable. In this method, we use dispersion measures (DMs) of fast radio bursts (FRBs) that appear behind the cluster and the Sunyaev–Zel’dovich (SZ) effect toward the cluster. The DMs reflect the density of the intracluster medium including the WHIM. If we observe a sufficient number of FRBs in the direction of the cluster, we can derive the density profile from the DMs. Similarly, we can derive the pressure profile from the SZ effect. By combining the density and the pressure profiles, the temperature profile can be obtained. Based on mock observations of nearby clusters, we find that the density of the WHIM will be determined even at >2 R{sub 200} from the cluster center when FRB observations with the Square Kilometre Array become available. The temperature can be derived out to r∼1.5 R{sub 200}, and the radius is limited by the current sensitivity of SZ observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Oxide dissolution and oxygen diffusion scenarios in niobium and implications on the Bean–Livingston barrier in superconducting cavities

We generalize a native Nb 2 O 5 dissolution model [G. Ciovati, Appl. Phys. Lett. 89, 022507 (2006)] to sequential overlayer dissolutions, multilayer dissolution, and realistic temperature profiles, which may be applicable to other materials. The model is applied to secondary ion mass spectrometry depth profile measurements for varying temperature profiles and two-step oxide dissolution in Nb and found to agree well. In the context of the Meissner screening response due to impurity profiles on the length scale of the London penetration depth, the shallow diffusion of O impurities results in a substantial decrease in the peak supercurrent density near the surface. In this framework, oxide dissolution and oxygen diffusion can account for a rise in peak supportable magnetic field in SRF cavities with baking time and a suppression after the optimal baking time is reached, in good agreement with peak-field baking temperatures and times as well as recent quench field measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Model of temperature, evaporation, and productivity in elevated experimental algae raceways and comparison with commercial raceways

Elevated Experimental Raceways (EERs) have been used at many research sites in the United States to evaluate algal biomass productivity. This paper develops temperature and evaporation models for EERs and then evaluates whether the temperature profile and resultant productivity in an EER is representative of large-scale commercial raceways. Open water surface evaporation and temperature models with shading algorithms were programmed in Python and calibrated with temperature and evaporation data from the EERs in the Regional Algal Feedstock Testbed (RAFT) experiments at the University of Arizona. The final calibrated model for EERs was named the EERTEM (Elevated Experimental Raceway Temperature and Evaporation Model). The energy balance algorithms in the Biomass Assessment Tool (BAT model) were also added to the Python code and used to develop temperature simulations of standard commercial paddlewheel raceways. A comparison of BAT and EERTEM simulations indicated that EER temperature fluctuations are not representative of in ground commercial paddlewheel raceways, primarily due to the buffering effect of soil heat flux in commercial raceways. With the different temperature profiles, biomass productivities of three algae species in the EERs were compared to productivities in commercial raceways. Differences in productivity between EERTEM and BAT model temperature profiles were observed when the maximum daytime temperature of one raceway was in the optimal growth range but the temperature of the other raceway exceeded or was below the optimal growth range.

Khawam, George↗

Oxide dissolution and oxygen diffusion scenarios in niobium and implications on the Bean–Livingston barrier in superconducting cavities

We generalize a native Nb2O5 dissolution model [G. Ciovati, Appl. Phys. Lett. 89, 022507 (2006)] to sequential overlayer dissolutions, multilayer dissolution, and realistic temperature profiles, which may be applicable to other materials. The model is applied to secondary ion mass spectrometry depth profile measurements for varying temperature profiles and two-step oxide dissolution in Nb and found to agree well. In the context of the Meissner screening response due to impurity profiles on the length scale of the London penetration depth, the shallow diffusion of O impurities results in a substantial decrease in the peak supercurrent density near the surface. In this framework, oxide dissolution and oxygen diffusion can account for a rise in peak supportable magnetic field in SRF cavities with baking time and a suppression after the optimal baking time is reached, in good agreement with peak-field baking temperatures and times as well as recent quench field measurements.

Lechner, Eric↗

A study of planetary meteorology

Inversion techniques are applied to the few earth based observations of the Jovian emission spectrum to obtain directly the profiles of atmospheric temperature and ammonia abundance. The temperature profile is characterized by a definite tropopause region with a temperature of about 115K and a stratospheric region in which the temperature slowly increases with altitude. The derived ammonia profile indicates the presence of a saturated ammonia layer with a base temperature of approximately 14OK. The concept is described deducing the temperature and constituent profile of a planetary atmosphere from orbiter measurements of the planet's IR limb radiance profile. Analysis of the weighting functions for the Martian atmosphere indicates that a limb radiance profile in the 15 micron CO2 band can be used to determine the Martian atmospheric temperature profile from 20 to 60 km.

Ohring, G.↗

An Efficient Monte Carlo Method for Modeling Radiative Transfer in Protoplanetary Disks

Monte Carlo methods have been shown to be effective and versatile in modeling radiative transfer processes to calculate model temperature profiles for protoplanetary disks. Temperatures profiles are important for connecting physical structure to observation and for understanding the conditions for planet formation and migration. However, certain areas of the disk such as the optically thick disk interior are under-sampled, or are of particular interest such as the snow line (where water vapor condenses into ice) and the area surrounding a protoplanet. To improve the sampling, photon packets can be preferentially scattered and reemitted toward the preferred locations at the cost of weighting packet energies to conserve the average energy flux. Here I report on the weighting schemes developed, how they can be applied to various models, and how they affect simulation mechanics and results. We find that improvements in sampling do not always imply similar improvements in temperature accuracies and calculation speeds.

radiative transfer↗

Design and fabrication of a multi-purpose soft x-ray array diagnostic system for KSTAR

A multi-purpose soft x-ray array diagnostic system was developed for measuring two-dimensional x-ray emissivity profile, electron temperature, Ar impurity transport, and total radiation power. A remotely controlled filter wheel was designed with three different choices of filters. The electron temperature profile can be determined from the ratio of two channels having different thickness of Be layer, and the Ar impurity concentration transport can be determined from a pair of Ar Ross filters (CaF{sub 2} and NaCl thin films). Without any filters, this diagnostic system can also be used as a bolometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗