Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical Algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Parallel auto-correlative statistics with VTK.

This report summarizes existing statistical engines in VTK and presents both the serial and parallel auto-correlative statistics engines. It is a sequel to [PT08, BPRT09b, PT09, BPT09, PT10] which studied the parallel descriptive, correlative, multi-correlative, principal component analysis, contingency, k-means, and order statistics engines. The ease of use of the new parallel auto-correlative statistics engine is illustrated by the means of C++ code snippets and algorithm verification is provided. This report justifies the design of the statistics engines with parallel scalability in mind, and provides scalability and speed-up analysis results for the autocorrelative statistics engine.

Pebay, Philippe Pierre↗

Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

Purpose: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis—particularly in younger patients—might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiation dose and MBIR in the MDCT assessment of airway WT. Methods: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo{sup TM}, GE Healthcare) were used to reconstruct CT images of the airways. For each kV–mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV–mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV–mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. Results: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Evaluating In-Clique and Topological Parallelism Strategies for Junction Tree-Based Bayesian Inference Algorithm on the Cray XMT

Long viewed as a strong statistical inference technique, Bayesian networks have emerged to be an important class of applications for high-performance computing. We have applied an architecture-conscious approach to parallelizing the Lauritzen-Spiegelhalter Junction Tree algorithm for exact inferencing in Bayesian networks. In optimizing the Junction Tree algorithm, we have implemented both in-clique and topological parallelism strategies to best leverage the fine-grained synchronization and massive-scale multithreading of the Cray XMT architecture. Two topological techniques were developed to parallelize the evidence propagation process through the Bayesian network. One technique involves performing intelligent scheduling of junction tree nodes based on its topology and relative size. The second technique involves decomposing the junction tree into a much finer tree-like representation to offer much more opportunities for parallelism. We evaluate these optimizations on five different Bayesian networks and report our findings and observations. Another important contribution of this paper is to demonstrate the application of massive-scale multithreading for load balancing and use of implicit parallelism-based compiler optimizations in designing scalable inferencing algorithms.

99 GENERAL AND MISCELLANEOUS↗

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.

60 APPLIED LIFE SCIENCES↗

ROOT: A C++ framework for petabyte data storage, statistical analysis and visualization

ROOT is an object-oriented C++ framework conceived in the high-energy physics (HEP) community, designed for storing and analyzing petabytes of data in an efficient way. Any instance of a C++ class can be stored into a ROOT file in a machine-independent compressed binary format. In ROOT the TTree object container is optimized for statistical data analysis over very large data sets by using vertical data storage techniques. These containers can span a large number of files on local disks, the web or a number of different shared file systems. In order to analyze this data, the user can chose out of a wide set of mathematical and statistical functions, including linear algebra classes, numerical algorithms such as integration and minimization, and various methods for performing regression analysis (fitting). In particular, the RooFit package allows the user to perform complex data modeling and fitting while the RooStats library provides abstractions and implementations for advanced statistical tools. Multivariate classification methods based on machine learning techniques are available via the TMVA package. A central piece in these analysis tools are the histogram classes which provide binning of one- and multi-dimensional data. Results can be saved in high-quality graphical formats like Postscript and PDF or in bitmap formats like JPG or GIF. The result can also be stored into ROOT macros that allow a full recreation and rework of the graphics. Users typically create their analysis macros step by step, making use of the interactive C++ interpreter CINT, while running over small data samples. Once the development is finished, they can run these macros at full compiled speed over large data sets, using on-the-fly compilation, or by creating a stand-alone batch program. Finally, if processing farms are available, the user can reduce the execution time of intrinsically parallel tasks - e.g. data mining in HEP - by using PROOF, which will take care of optimally distributing the work over the available resources in a transparent way.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

Realizable hyperuniform and nonhyperuniform particle configurations with targeted spectral functions via effective pair interactions

The capacity to identify realizable many-body configurations associated with targeted functional forms for the pair correlation function $g_2(r)$ or its corresponding structure factor $\textit{S(k)}$ is of great fundamental and practical importance. While there are obvious necessary conditions that a prescribed structure factor at number density ρ must satisfy to be configurationally realizable, sufficient conditions are generally not known due to the infinite degeneracy of configurations with different higher-order correlation functions. A major aim of this paper is to expand our theoretical knowledge of the class of pair correlation functions or structure factors that are realizable by classical disordered ensembles of particle configurations, including exotic “hyperuniform” varieties. We first introduce a theoretical formalism that provides a means to draw classical particle configurations from canonical ensembles with certain pairwise-additive potentials that could correspond to targeted analytical functional forms for the structure factor. This formulation enables us to devise an improved algorithm to construct systematically canonical-ensemble particle configurations with such targeted pair statistics, whenever realizable. As a proof of concept, we test the algorithm by targeting several different structure factors across dimensions that are known to be realizable and one hyperuniform target that is known to be nontrivially unrealizable. Our algorithm succeeds for all realizable targets and appropriately fails for the unrealizable target, demonstrating the accuracy and power of the method to numerically investigate the realizability problem. Subsequently, we also target several families of structure-factor functions that meet the known necessary realizability conditions but are not known to be realizable by disordered hyperuniform point configurations, including $\textit{d}$-dimensional Gaussian structure factors, $\textit{d}$-dimensional generalizations of the two-dimensional one-component plasma (OCP), and the $\textit{d}$-dimensional Fourier duals of the previous OCP cases. Moreover, we also explore unusual nonhyperuniform targets, including “hyposurficial” and “antihyperuniform” examples. In all of these instances, the targeted structure factors are achieved with high accuracy, suggesting that they are indeed realizable by equilibrium configurations with pairwise interactions at positive temperatures. Remarkably, we also show that the structure factor of nonequilibrium perfect glass, specified by two-, three-, and four-body interactions, can also be realized by equilibrium pair interactions at positive temperatures. In this work, our findings lead us to the conjecture that any realizable structure factor corresponding to either a translationally invariant equilibrium or nonequilibrium system can be attained by an equilibrium ensemble involving only effective pair interactions. Our investigation not only broadens our knowledge of analytical functional forms for $g_2(r)$ and $\textit{S(k)}$ associated with disordered point configurations across dimensions but also deepens our understanding of many-body physics. Moreover, our work can be applied to the design of materials with desirable physical properties that can be tuned by their pair statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reference gene selection for real-time RT-PCR in regenerating mouse livers

The liver has an intrinsic ability to undergo active proliferation and recover functional liver mass in response to an injury response. This regenerative process involves a complex yet well orchestrated change in the gene expression profile. To produce accurate and reliable gene expression of target genes during various stages of liver regeneration, the determination of internal control housekeeping genes (HKGs) those are uniformly expressed is required. In the present study, the gene expression of 8 commonly used HKGs, including GAPDH, ACTB, HPRT1, GUSB, PPIA, TBP, TFRC, and RPL4, were studied using mouse livers that were quiescent and actively regenerating induced by partial hepatectomy. The amplification of the HKGs was statistically analyzed by two different mathematical algorithms, geNorm and NormFinder. Using this method, PPIA and TBP gene expression found to be relatively stable regardless of the stages of liver regeneration and would be ideal for normalization to target gene expression.

60 APPLIED LIFE SCIENCES↗

Volumetric analysis and mesh generation of real and artificial microstructural geometries

Producing a viable finite element mesh of realistic microstructural structural geometry is a critical step in analyzing the thermo-mechanical behavior of complex multi-material composites. Advancements in imaging technology such as micro computed tomography have allowed modelers to access high resolution mesoscale geometries for direct numerical simulation. However, converting from voxel based 3D images to usable finite element meshes has been challenging. A robust method including algorithms and software scripts for generating finite element meshes from 3D imaged microstructures is presented in this paper. It includes a routine for inserting cohesive elements around material interfaces to enable modeling of interface properties including delamination and damage. The algorithms and procedures presented in this method leverage currently available software packages for processing surface based geometry into volume based meshes. In addition to converting real geometry from physical imaging systems, algorithms for producing numerically generated and statistically equivalent microstructural geometry are also included. These artificial microstructures can be a valuable resource for modelers when physical specimens do not exist or are limited in quantity: Method establishes a workflow from voxel data to viable finite element mesh including interface information, and Includes a method for synthetic geometry generation based on metrics from real microstructures.

36 MATERIALS SCIENCE↗

Data augmentation for disruption prediction via robust surrogate models

The goal of this work is to generate large statistically representative data sets to train machine learning models for disruption prediction provided by data from few existing discharges. Such a comprehensive training database is important to achieve satisfying and reliable prediction results in artificial neural network classifiers. Here, we aim for a robust augmentation of the training database for multivariate time series data using Student t process regression. We apply Student t process regression in a state space formulation via Bayesian filtering to tackle challenges imposed by outliers and noise in the training data set and to reduce the computational complexity. Thus, the method can also be used if the time resolution is high. We use an uncorrelated model for each dimension and impose correlations afterwards via colouring transformations. We demonstrate the efficacy of our approach on plasma diagnostics data of three different disruption classes from the DIII-D tokamak. To evaluate if the distribution of the generated data is similar to the training data, we additionally perform statistical analyses using methods from time series analysis, descriptive statistics and classic machine learning clustering algorithms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The local dark matter phase-space density and impact on WIMP direct detection

We present a new determination of the local dark matter phase-space density. This result is obtained implementing, in the limit of isotropic velocity distribution and spherical symmetry, Eddington's inversion formula, which links univocally the dark matter distribution function to the density profile, and applying, within a Bayesian framework, a Markov Chain Monte Carlo algorithm to sample mass models for the Milky Way against a broad and variegated sample of dynamical constraints. We consider three possible choices for the dark matter density profile, namely the Einasto, NFW and Burkert profiles, finding that the velocity dispersion, which characterizes the width in the distribution, tends to be larger for the Burkert case, while the escape velocity depends very weakly on the profile, with the mean value we obtain being in very good agreement with estimates from stellar kinematics. The derived dark matter phase-space densities differ significantly — most dramatically in the high velocity tails — from the model usually taken as a reference in dark matter detection studies, a Maxwell-Boltzmann distribution with velocity dispersion fixed in terms of the local circular velocity and with a sharp truncation at a given value of the escape velocity. We discuss the impact of astrophysical uncertainties on dark matter scattering rates and direct detection exclusion limits, considering a few sample cases and showing that the most sensitive ones are those for light dark matter particles and for particles scattering inelastically. As a general trend, regardless of the assumed profile, when adopting a self-consistent phase-space density, we find that rates are larger, and hence exclusion limits stronger, than with the standard Maxwell-Boltzmann approximation. Tools for applying our result on the local dark matter phase-space density to other dark matter candidates or experimental setups are provided.

79 ASTRONOMY AND ASTROPHYSICS↗

Stokhos v 1.0

A Trilinos package for applying stochastic Galerkin uncertainty quantification methods to large-scale C++ application codes, primarily stochastic partial differential equations. Stokhos is intended for use in estimating uncertainties for general scientific computations and is based on published algorithms. It provides no capability for implementing those computations itself. Estimating uncertainties and errors from solution algorithms or simulations, primarily simulations of partial differential equations, arising from uncertainties or errors in solution algorithm or simulation input data, including statistical moments, probabilities, and coefficients of variation.

Source record↗

sdt (Solar Data Tools) [SWR-25-130]

Solar Data Tools (sdt) is an open-source Python library for analyzing PV power (and irradiance) time-series data. It was developed to enable analysis of unlabeled PV data, i.e. with no model, no meteorological data, and no performance index required, by taking a statistical signal processing approach in the algorithms used in the package’s main data processing pipeline. Solar Data Tools empowers PV system fleet owners or operators to analyze system performance a hundred times faster even when they only have access to the most basic data stream—power output of the system.

Meyers-Im, Bennet [National Laboratory of the Rock↗

Data augmentation for disruption prediction via robust surrogate models

The goal of this work is to generate large statistically representative datasets to train machine learning models for disruption prediction provided by data from few existing discharges. Such a comprehensive training database is important to achieve satisfying and reliable prediction results in artificial neural network classifiers. Here, we aim for a robust augmentation of the training database for multivariate time series data using Student-t process regression. We apply Student-t process regression in a state space formulation via Bayesian filtering to tackle challenges imposed by outliers and noise in the training data set and to reduce the computational complexity. Thus, the method can also be used if the time resolution is high. We use an uncorrelated model for each dimension and impose correlations afterwards via coloring transformations. We demonstrate the efficacy of our approach on plasma diagnostics data of three different disruption classes from the DIII-D tokamak. To evaluate if the distribution of the generated data is similar to the training data, we additionally perform statistical analyses using methods from time series analysis, descriptive statistics, and classic machine learning clustering algorithms.

97 MATHEMATICS AND COMPUTING↗

From systems biology to photosynthesis and whole-plant modeling: a conceptual model for integrating multi-scale networks

Network analysis is now a common statistical tool for molecular biologists. Network algorithms are readily used to model gene, protein and metabolic correlations providing insight into pathways driving biological phenomenon. One output from such an analysis is a candidate gene list that can be responsible, in part, for the biological process of interest. The question remains, however, as to whether molecular network analysis can be used to inform process models at higher levels of biological organization. In our previous work, transcriptional networks derived from three plant species were constructed, interrogated for orthology and then correlated to photosynthetic inhibition at elevated temperature. One unique aspect of that study was the link from co-expression networks to net photosynthesis. In this addendum, we propose a conceptual model where traditional network analysis can be linked to whole-plant models thereby informing predictions on key processes such as photosynthesis, nutrient uptake and assimilation, and C partitioning.

59 BASIC BIOLOGICAL SCIENCES↗

Stokhos v 1.0

A Trilinos package for applying stochastic Galerkin uncertainty quantification methods to large-scale C++ application codes, primarily stochastic partial differential equations. Stokhos is intended for use in estimating uncertainties for general scientific computations and is based on published algorithms. It provides no capability for implementing those computations itself. Estimating uncertainties and errors from solution algorithms or simulations, primarily simulations of partial differential equations, arising from uncertainties or errors in solution algorithm or simulation input data, including statistical moments, probabilities, and coefficients of variation.

Source record↗