Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Standard surface-reflectance model and illuminant estimation

A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.

Tominaga, Shoji↗

Executive overview and introduction to the SMAP information system life-cycle and documentation standards

An overview of the five volume set of Information System Life-Cycle and Documentation Standards is provided with information on its use. The overview covers description, objectives, key definitions, structure and application of the standards, and document structure decisions. These standards were created to provide consistent NASA-wide structures for coordinating, controlling, and documenting the engineering of an information system (hardware, software, and operational procedures components) phase by phase.

Source record↗

The next 40 years in space standards

Methods used in producing, introducing, and using standards for civilian space research are examined, with special consideration given to the recommendations of the Consultative Committee for Space Data Systems (CCSDS) as an example of a set of standards best coordinated through the International Standard Organization (ISO). The paper uses an example of earth-observation data as a CCSDS application for an international coordination effort within the ISO and describes progress in achieving this objective. Lists of CCDSD member agencies and CCSDS observer agencies are included.

Sheetz, H. J.↗

Lithium in halo stars from standard stellar evolution

A grid has been constructed of theoretical evolution sequences of models for low-metallicity stars from the premain-sequence to the giant branch phases. The grid is used to study the history of surface Li abundance during standard stellar evolution. The Li-7 observations of halo stars by Spite and Spite (1982) and subsequent observations are synthesized to separate the halo stars by age. The theory of surface Li abundance is illustrated by following the evolution of a reference halo star model from the contracting fully convective premain sequence to the giant branch phase. The theoretical models are compared with observed Li abundances. The results show that the halo star lithium abundances can be explained in the context of standard stellar evolution theory using completely standard assumptions and physics.

Deliyannis, Constantine P.↗

The classical microwave frequency standards

Some key problems are presented encountered in the classical microwave frequency standards which are still not solved today. The point of view expressed benefits from the experience gained both in the industry and in the research lab, on the following classical microwave frequency standards: active and passive H, conventional and laser pumped Cs beam tube, small conventional and laser pumped Rubidium. The accent is put on the Rubidium standard.

Busca, Giovanni↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

The physics of the environmental sensitivity of rubidium gas cell atomic frequency standards

Environmental sensitivity is often the most significant limitation to the practical stability of rubidium frequency standards (RFS). For example, temperature sensitivity can cause a rapid frequency change of several parts in 10(exp 10) for a tactical RFS that has an aging of only 1 times 10(exp -11)/month. Other important environmental factors are barometric pressure, vibration, magnetic field, and nuclear radiation. The physical mechanisms that lie behind these environmental sensitivities are considered. These physical mechanisms are related to the performance of actual rubidium frequency standards. For the user of these devices, a better knowledge of the causes for Rb clock instability will aid in their testing and proper application. For the time frequency specialist, a review of these factors may prove useful toward improving RFS design. Some of the RFS environmental sensitivities are due to simple physical mechanisms like the effect of dc magnetic field on the Rb hyperfine resonance frequency. For these, an analysis can be based on physical principles and straightforward design factors. Other environment factors, like temperature sensitivity, are more complex combinations of many effects, both physical and practical, and the analysis often takes the form of an error budget with large unit-to-unit variations. Today's rubidium frequency standards span a wide performance range from small, inexpensive units with pp 10(exp 10) error budgets to larger, higher performance versions offering pp 10(exp 10) stabilities. For both extremes, however, environmental sensitivity can be the most significant performance limitation. Why this is the case and how to make improvements are discussed.

Riley, William J.↗

Nitrogen abundances from UV lines of HgMn and standard late-B stars

A recent survey by Roby (1987) discovered that the relatively weak high excitation lines of N 1 near 7468 and 8680 A were undetectable in the majority of HgMn stars, leading to upper limits on the N abundance of roughly ten times below that of the solar N abundance. Standard stars with similar temperatures (10,000 to 13,000 K) did exhibit these same N lines and were found to have roughly solar N abundances. The N abundances were redetermined in two HgMn stars and four standard stars using the strong, low excitation lines of N 1 found in the ultraviolet. The observational data consisted of high quality, high resolution, co-added International Ultraviolet Explorer spectra which was previously collected and reduced. Examination of the spectra plus considerations of signal/noise and severe line blending led to the choice of three promising N 1 lines located at 1742.7, 1745.3 and 1411.9 A. The atomic data for these lines were previously calculated using the best laboratory measurements found in a search of the relevant literature. The chosen N lines turned out to be blended significantly with Fe 2 lines. To obtain the abundances for N synthetic spectra were computed to match the observed spectra. The synthetic spectra were calculated using lie-blanketed model atmospheres, stellar parameters, and abundances for the other elements based upon previous work by S. Adelman. The N abundance was then adjusted to give the best fit of the observed line profiles. In the 2 HgMn stars, the N lines were again found to be undetectable, but the stronger intrinsic strength of the new lines yield more stringent upper limits than those obtained previously. Model atmosphere and abundances were updated in two stars where new results were reported. An additional N 1 line and an additional standard star were added to the program. A line opacity model was developed for a missing feature adjacent to the N 1 line at 1745.2 A, leading to a 25 percent improvement in the determined from this line.

Roby, Scott W.↗

The Small Explorer Data System - A data system based on standard interfaces

The Small Explorer Data System was developed by NASA Goddard Space Flight Center using a 'standard interfaces' approach. Standard interfaces make it adaptable to a wide variety of missions. The paper describes the Small Explorer Data System with particular emphasis on the standard interfaces incorporated in both the hardware and software.

Smith, Brian S.↗

Standard terminology in the laboratory and classroom

Each of the materials produced by modern technologists is associated with a family of immaterials--all the concepts of substance, process, and purpose. It is concepts that are essential to transfer knowledge. It is concepts that are the stuff of terminology. Terminology is standardized today by companies, standards organizations, governments, and other groups. Simply described, it is the pre-negotiation of the meanings of terms. Terminology has become a key issue in businesses, and terminology knowledge is essential in understanding the modern world. The following is a introductory workshop discussing the concepts of terminology and methods of its standardization.

Strehlow, Richard A.↗

Measuring frequency changes due to microwave power variations as a function of C-field setting in a rubidium frequency standard

It has been shown in previous studies that in some cesium frequency standards there exist certain C-field settings that minimize frequency changes that are due to variations in the microwave power. In order to determine whether similar results could be obtained with rubidium (Rb) frequency standards (clocks), we performed a similar study, using a completely automated measurement system, on a commercial Rb standard. From our measurements we found that changing the microwave power to the filter cell resulted in significant changes in frequency, and that the magnitude of these frequency changes at low C-field levels went to zero and decreased as the C-field was increased.

E. B. Sarosy↗

Development of a NASA standard gas generator

The goals of the NASA Standard Gas Generator (NSGG) Program are to create a NASA standard gas generating cartridge, characterize its performance, and make it readily available to users. A cartridge within the same envelope as the NASA Standard Initiator (NSI) has the greatest potential use. This potential use is described in viewgraph form. Our approach for NSGG development and qualification was planned to be conducted in several phases. Test methods were developed to evaluate output performance for a variety of potential applications. A feasibility study using modified NSI's was accomplished. Preliminary and final development will be conducted with a delta qualification to evaluate the effects of manufacturing lots and environments. Feasibility study results, feasibility study conclusions, and future plans are presented.

Bement, Laurence J.↗

Preliminary results: Root cause investigation of orbital anomalies and failures in NASA standard 50 ampere-hour nickel-cadmium batteries

Two lots of NASA standard 50 A.H. Ni-Cd battery cells, manufactured by Gates Aerospace Batteries and built into batteries by McDonnell Douglas, have experienced significant performance problems. The two lots were used on the Compton Gamma Ray Observatory and the Upper Atmosphere Research Satellite. Both of these satellites are Low Earth Orbital (LEO) satellites containing batteries on a parallel bus charged to NASA standard V/T curves using a NASA standard power regulator. The following preliminary conclusions were reached: (1) several plate and cell parameters have migrated within their spec limits over the years (in some cases, from one extreme to the other); (2) several parametric relationships, not generally monitored and therefore not under specification control, have also migrated over the years; (3) many of these changes appear to have taken place as a natural consequence of changes in GE/GAB materials and processes; (4) several of these factors may be 'conspiring' to aggravate known cell failure mechanisms (factors such as heavier plate, less teflon and/or less-uniform teflon, and less electrolyte) but all are still in spec (where specs exist); (5) the weight of the evidence collected to characterize the anomalies and to characterize the negative electrode itself, strongly suggests that alterations to the structure, composition, uniformity, and efficiency of the negative electrode are at the heart of the battery performance problems currently being experienced; and (6) further investigation at all levels (plate, cell, battery, and system) continues to be warranted.

Toft, Mark R.↗

Helicopter simulator standards

The initial advisory circular was produced in 1984 (AC 120-XX). It was not finalized, however, because the FAR's for pilot certification did not recognize helicopter simulators and, therefore, permitted no credit for their use. That is being rectified, and, when the new rules are published, standards must be available for qualifying simulators. Because of the lack of a data base to support specification of these standards, the FAA must rely on the knowledge of experts in the simulator/training industry. A major aim of this workshop is to form a working group of these experts to produce a set of standards for helicopter training simulators.

Boothe, Edward M.↗

The standards process: X3 information processing systems

The topics are presented in viewgraph form and include the following: International Organization for Standards (ISO); International Electrotechnical Committee (IEC); ISO/IEC Joint Technical Committee 1 (JTC-1); U.S. interface to JTC-1; ANSI; national organizations; U.S. standards development processes; national and international standards developing organizations; regional organizations; and X3 information processing systems.

Emard, Jean-Paul↗

The standards process: Technical committee X3B5 digital magnetic tape

The definition of X3B5, where it fits in the national and international standards development process, and how it interfaces and influences the world community of standards developers are provided. Details concerning the focus of the committee, how it operates, and what the group sees as the future trends in the area of interchange standards utilizing the multifaceted, ubiquitous magnetic tape are presented.

Cheatham, Sam↗

Ultra-stable Hg(+) trapped ion frequency standard

We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.

Prestage, J. D.↗

Correlation between strength properties in standard test specimens and molded phenolic parts

This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.

MATERIALS, MONSANTO RESINOX↗