Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Barrier reinforcement for enhanced perovskite solar cell stability under reverse bias

Stability of perovskite solar cells (PSCs) under light, heat, humidity and their combinations have been notably improved recently. However, PSCs have poor reverse-bias stability that limits their real-world application. Here we report a systematic study on the degradation mechanisms of p-i-n structure PSCs under reverse bias. The oxidation of iodide by injected holes at the cathode side initialize the reverse-bias-induced degradation, then the generated neutral iodine oxidizes metal electrode such as copper, followed by drift of Cu+ into perovskites and its reduction by injected electrons, resulting in localized metallic filaments and thus device breakdown. A reinforced barrier with combined lithium fluoride, tin oxide and indium tin oxide at the cathode side reduces device dark current and avoids the corrosion of Cu0. It dramatically increases breakdown voltage to above -20 V and improved the T90 lifetime of PSCs to ~1,000 h under -1.6 V. The modified minimodule also maintained over 90% of its initial performance after 720 h of shadow tests.

degradation mechanisms↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Overcoming Shockley-Queisser limit using halide perovskite platform?

The Intergovernmental Panel on Climate Change (IPCC) reveals that the global temperature has reached its highest level in the last 2,000 years. Development of emissions-free electrification technologies such as photovoltaics (PV) can be a great paramountcy to balance the climate pressure and the growing demand on energy. Although many PV technologies have been demonstrated so far, all the single-junction PVs are still subjected to the well-known efficiency cap of the Shockley-Queisser limit (33.7%), with most of the absorbed solar energy lost into heat. In parallel to delicate system-level designs, such as tandem, multi-junction, photothermal, or up-/down-conversion, we ask the question about the feasibility of overcoming the SQ limit at material level. In this study, we first dissect the origin of the limit, and then, by using the emerging perovskite as the platform, we list several potential pathways (i.e., hot carrier, multi-exciton generation, intermediate band gap, and ferroelectricity that have been newly discovered or can be introduced in the perovskite) to the roadmap of exceeding the SQ limit.

14 SOLAR ENERGY↗

Multi-scale Dynamics of Kinetic Turbulence in Weakly Collisional, High-Beta Plasmas (Final Report for DOE Grant DE-SC0019046)

This grant was a collaborative grant between Prof Matt Kunz (Princeton) and Prof. Eliot Quataert. Quataert was initially a faculty member at UC Berkeley when the grant was funded but moved to Princeton during the timeframe of this grant. Over the course of this grant we made major progress on understanding turbulence and multi-scale dynamics in weakly collisional high-beta plasmas. The most important contributions included: We developed one of the most compelling theoretical explanations for a decades-old puzzle at the heart of our understanding of the origin of the solar wind. The puzzle is that many of the observations of ion temperatures and distribution functions in the solar wind are consistent with cyclotron resonant heating. However, theoretical models of MHD turbulence in the solar wind show that most of the turbulent energy remains at low frequencies below the cyclotron frequency. In Squire et al. (2022), we showed, however, that in imbalanced turbulence (in which there is an asymmetry in the Alfven-wave flux in opposite directions along the magnetic field), which is the norm in the fast solar wind, the turbulent energy reaches a ‘bottleneck’ near the ion Larmor radius, and the amplitude and characteristic frequency of the fluctuations grow until the cyclotron frequency is reached.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental testing of particle attrition in CSP systems at high temperature

An alternate and sustainable form of energy is CSP systems, which capture and store the sun’s energy in the form of heat. Increasing the operational temperature of CSP systems will increase the efficiency of electricity production while operating at temperatures exceeding 700 degrees Celsius also creates novel operational problems. One approach for high-temperature CSP systems is to utilize solid particles as the primary heat transfer medium. As particles flow through this system, the movement of particles creates erosion in the forms of impact, abrasion, and attrition erosion. In the real world, while all three forms of erosion will occur simultaneously, it is imperative to understand the individual effect of each erosion over the lifetime of the powerplant. Besides material erosion and long-term durability concerns, thermal cycling of the particles could also introduce changes in particle thermal performance due to alterations in particle morphology. Current research on the issue of erosion has been limited to industrial applications and does not necessarily coincide with the operating conditions in CSP systems. We focus on attrition erosion resulting from particle-to-wall and particle-to-particle interactions. Research has shown that besides material hardness affecting how fast particles break down, attrition erosion increased as the size of the particles increased due to a higher chance of collision between the particles. Particle attrition is relevant to the CSP community as it may result in material loss, change the system's thermal performance, and generation of fines which could pose an environmental hazard. In this work, we focus on developing a test set up that can isolate and measure particle attrition when subjected to conditions relevant to Gen3 CSP systems.

14 SOLAR ENERGY↗

Evaluation of external tubular configurations for a high-temperature chloride molten salt solar receiver operating above 700°C

Next-generation concentrating solar power (CSP) tower technologies target operating temperatures exceeding 700°C to increase the thermal-to-electric conversion efficiency. Molten chloride salts are one possible alternative to current commercial molten nitrate salts to enable the higher operating temperature. This paper analyzes the predicted optical, thermal-fluids, and structural performance of traditional external tubular solar receiver configurations applied with a chloride salt heat transfer fluid (HTF) and inlet/outlet temperatures of 500°C/735°C, and considers sensitivity analysis and optimization relative to receiver sizing, tube sizing, number of panels, flow circuit configurations, and solar flux concentration under constraints on internal velocity, pressure drop, wall thickness, and required creep-fatigue lifetime. The high temperature conditions increase the significance of inelastic deformation mechanisms such as creep relative to that expected in commercial 565°C nitrate salt designs. High-temperature creep and creep-fatigue damage in the metal alloy tubes are the key factors that limit allowable solar flux concentration and achievable receiver thermal efficiency at the near-800°C wall temperature conditions. For a traditional external cylindrical receiver configuration, the design parameters and conditions capable of satisfying all constraints produced, at best, a design point receiver efficiency of 78.2%, or 80.5% when excluding receiver intercept efficiency. Variation in the optimal receiver performance relative to uncertainty in the binding maximum velocity, minimum wall thickness, and minimum lifetime constraints is presented.

14 SOLAR ENERGY↗

Large Area Near‐Field Thermophotovoltaics for Low Temperature Applications

Abstract Thermophotovoltaics, devices that convert thermal infrared photons to electricity, offer a key pathway for a variety of critical renewable energy technologies including thermal energy storage, waste heat recovery, and direct solar‐thermal power generation. However, conventional far‐field devices struggle to generate reasonable powers at lower temperatures. Near‐field thermophotovoltaics provide a pathway to substantially higher powers by leveraging photon tunneling effects. Here a large area near‐field thermophotovoltaic device is presented, created with an epitaxial co‐fabrication approach, that consists of a self‐supported 0.28 cm 2 emitter‐cell pair with a 150 nm gap. The device generates 1.22 mW at 460 °C, a 25‐fold increase over the same cell measured in a far‐field configuration. Furthermore, the near‐field device demonstrates short circuit current densities greater than the far‐field photocurrent limit at all the temperatures tested, confirming the role of photon tunneling effects in the performance enhancement. Modeling suggests several practical directions for cell improvements and further increases in power density. These results highlight the promise of near‐field thermophotovoltaics, especially for low temperature applications.

36 MATERIALS SCIENCE↗

Towards Energy–Efficient Direct Air Capture with Photochemically–Driven CO 2 Release and Solvent Regeneration

The intensive energy demands associated with solvent regeneration and CO 2 release in current direct air capture (DAC) technologies makes their deployment at the massive scales (GtCO 2 /year) required to positively impact the climate economically unfeasible. This challenge underscores the critical need to develop new DAC processes with significantly reduced energy costs. Recently, we developed a new approach to photochemically drive efficient release of CO 2 through an intermolecular proton transfer reaction by exploiting the unique properties of an indazole metastable-state photoacid (mPAH), opening a new avenue towards energy efficient on-demand CO 2 release and solvent regeneration using abundant solar energy instead of heat. In this Concept Article, we will describe the principle of our photochemically-driven CO 2 release approach for solvent-based DAC systems, discuss the essential prerequisites and conditions to realize this cyclable CO 2 release chemistry under ambient conditions. We outline the key findings of our approach, discuss the latest developments from other research laboratories, detail approaches used to monitor DAC systems in situ, and highlight experimental procedures for validating its feasibility. Finally, we conclude with a summary and outlook into the immediate challenges that must be addressed in order to fully exploit this novel photochemically-driven approach to DAC solvent regeneration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of flow properties coupled to experimental and numerical analyses of dense, granular flows for solar thermal energy storage

Granular flows of sintered bauxite proppants were researched along an inclined plane for solar thermal energy storage applications. Granular flow properties needed to drive numeric granular models were measured for improved numerical model predictions for Carbobead CP 50/140, 40/100, and 30/60 particles. Particle shape and size distributions were determined by coupling optical microscopy to an in-house image processing algorithm. The impulse excitation technique was used to measure elastic and shear moduli, and compute Poisson’s ratio. The coefficient of static sliding friction was measured using the slip-stick method, and the static rolling friction was determined from measured shear on particles positioned between two hot-pressed plates. The coefficient of restitution was measured by dropping particles on a surface and determining the kinetic energy before and after impact with the surface using high resolution particle tracking velocimetry. Particle size did not significantly impact the coefficients of restitution and static rolling friction, however, particle shape distribution resulted in a large variation in measurements. An inclined flow experiment was performed to characterize granular flows of Carbobead CP 30/60 particles using particle image velocimetry. Numerical models of the experiment using discrete element method were generated with the measured mechanical properties as inputs for comparison with experimental results. A constant directional torque rolling friction model best predicted bulk granular flow behavior. Furthermore, good agreement between the model and experiment was achieved at ambient, steady state conditions, with average velocity differences <10%.

14 SOLAR ENERGY↗

Numerical analyses of high temperature dense, granular flows coupled to high temperature flow property measurements for solar thermal energy storage

High temperature particle flow properties necessary to predict granular flow behavior for solar thermal energy storage applications were measured and calculated for Carbobead CP 30/60 up to 800 °C. Here, the measured properties included elastic and shear moduli, particle-particle coefficients of static sliding and rolling friction, and particle-particle coefficients of restitution. Poisson’s ratio was calculated with elastic and shear moduli. The flow properties were used as inputs for a numerical model using the discrete element method to examine granular flows along an inclined plane at high temperature. The flow behavior was strongly influenced by the coefficients of static friction, which impacted the particle residence time, shear effects from the side walls, and particle flow mass flux. An 8.7%, 15.6%, and 8.5% increase and 37.9% decrease in steady state mass flow rate was observed for 200 °C, 400 °C, 600 °C, and 800 °C, respectively, when compared to room temperature simulations. A 52%, 59%, and 33% decrease in the time to reach steady state was observed for 200 °C, 400 °C, and 600 °C, respectively, while a 53% increase in time was observed for 800 °C. A significant delay in the flow development at 800 °C was observed due to significantly higher frictional forces.

14 SOLAR ENERGY↗

Multi-Electron Transfer at H-Terminated p-Si Electrolyte Interfaces: Large Photovoltages under Inversion Conditions

Here, photovoltages for hydrogen terminated p-Si(111) in an acetonitrile electrolyte were quantified with methyl viologen [1,1'-(CH 3 ) 2 -4,4'-bipyridinium](PF 6 ) 2 , abbreviated MV 2+ , and [Ru(bpy) 3 ](PF 6 ) 2 , where bpy is 2,2'-bipyridine, that respectively undergo two and three one-electron transfer reductions. The reduction potentials, E°, of the two MV 2+ reductions occurred at energies within the forbidden bandgap, while the three [Ru(bpy) 3 ] 2+ reductions occurred within the continuum of conduction band states. Bandgap illumination resulted in reduction that were more positive than that measured with a degenerately doped n + -Si demonstrative of a photovoltage, Vph, that increased in the order: MV 2+/+ (260 mV) < MV +/0 (400 mV) < Ru 2+/+ (530 mV) ~ Ru +/0 (540 mV) ~ Ru 0/– (550 mV). Pulsed 532 nm excitation generated electron-hole pairs whose dynamics were nearly constant under depletion conditions and increased markedly as the potential was raised or lowered. A long wavelength absorption feature assigned to conduction band electrons provided additional evidence for the presence of an inversion layer. Collectively, the data reveal that the most optimal photovoltage, as well at the longest electron-hole pair lifetime and the highest surface electron concentration, occur when E° lies energetically within the unfilled conduction band states where an inversion layer is present. The bell-shaped dependence for electron-hole pair recombination with the surface potential was predicted by the time-honored SRH model providing a clear indication that this interface provides access to all four bias conditions, i.e., accumulation, flat band, depletion, and inversion. The implications of these findings for photocatalysis applications and solar energy conversion are discussed.

14 SOLAR ENERGY↗

Observational Constraints on the Spatial Effect of Greenness and Canopy Cover on Urban Heat in a Major Midlatitude City

Abstract Urban heat stress is a critical issue, particularly in cities where dense infrastructure and limited green space exacerbate temperature extremes. This study investigates the impact of greenery (EVI2), canopy cover (CC), impervious cover (IC), and water bodies on heat index in Chicago using high‐resolution data from the Heat Watch campaign. We find that EVI2, CC and proximity to water body significantly reduce heat while IC increases heat, particularly in the afternoon when solar radiation is intense. Additionally, the effective radius that land cover impacts heat is smaller in the afternoon. The combined effect analysis indicates that enhancing total greenness, not just canopy cover, is the most effective strategy to reduce heat. This study underscores the importance of strategic vegetation management, highlighting the critical role of integrated approaches in reducing urban heat.

Lee, Jangho↗

Optical Flow Diagnostics of Counter Fluidization of Gravity-Driven Moving Packed Bed for a CSP Receiver Section Featuring Staggered Array of Cylindrical Pins

Particle fluidized beds have the potential to improve the efficiency of heat transfer in concentrated solar receiver furnace for use in next generation concentrated solar power (CSP) plants. This study presents an experimental investigation on the flow characterization of vertically downward moving packed bed with counter fluidization through an array of jets. To control the bubble size and its distribution in the bubbling fluidized bed, an array of cylindrical pin fins was arranged uniformly across the test article. The flow visualization was performed on the surface of transparent glass coated with electrically conductive materials for electrostatic dissipation purposes. The image acquisition was carried out via high-speed camera at a frequency of ~ 1kHz. The acquired images were analyzed in pairs with the help of a modern optical flow algorithm capable of calculating the movement of dense particle flow in the fluidized bed by tracking the light intensity of each predefined window of the frames. A comparison of fluidized beds with plane and pin-finned channels revealed distinct bubble behavior. Pin-finned channels were found to produce a larger number of small-sized bubbles, while plane channels generated fewer but larger bubbles at any given instant. The presence of pin fins was observed to reduce bubble size by preventing bubble merging and splitting larger bubbles when they encountered a pin.

concentrating solar power↗

Heat Transfer Characteristics of Particle Flow Through Additively Manufactured (SS 316L) Lattice Frame Material Based on Octet-Shape Topology

Abstract This paper presents experimentally obtained heat transfer characteristics of additively manufactured lattice frame material based on Octet-shaped unit cell. Binder jetting technology was used to print lattices in Stainless Steel 316L material. Lattice porosities ranging from 0.75 to 0.9 were investigated where thermal transport characteristics were obtained for void space occupied by air and particles. Particle diameters were varied from 266–966 microns. Effective thermal conductivity and averaged heat transfer coefficient was calculated through steady-state experiments. It was found that presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200–400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape based lattice frame material for particle flow through them makes it a very promising candidate for particle-to-supercritical carbon dioxide (sCO2) heat exchanger in concentrating solar power (CSP) application.

Aider, Youssef↗

REopt Lite User Manual

REopt Lite evaluates the economic viability of grid-connected solar photovoltaics, wind, combined heat and power, and electric and thermal storage at commercial and small industrial sites. It allows building owners to identify the system sizes and dispatch strategies that minimize the site’s life cycle cost of energy. REopt Lite also estimates the amount of time on-site generation and storage can sustain the site's critical load during a grid outage and allows the user the choice of optimizing for energy resilience. It is primarily used to inform project development decisions and to support research on the factors that drive project feasibility for market development and policy analysis. It is available through a web interface, application programing interface, and open-source code. This user manual provides an overview of the model, including its capabilities and typical applications; inputs and outputs; economic calculations; technology descriptions; and model parameters, variables, and equations. The model is highly flexible and is continually evolving to meet the needs of each analysis. Therefore, this report is not an exhaustive description of all capabilities, but rather a summary of the core components of the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗