Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

A Portable Quantitative High-Resolution Gamma System for In-Situ Waste, D and D, and Emergency Measurements - 18573

The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Early Detection of Li-Ion Battery Thermal Runaway Using Commercial Diagnostic Technologies

The rate of electric vehicle (EV) adoption, powered by the Li-ion battery, has grown exponentially; largely driven by technological advancements, consumer demand, and global initiatives to reduce carbon emissions. As a result, it is imperative to understand the state of stability (SoS) of the cells inside an EV battery pack. That understanding will enable the warning of or prevention against catastrophic failures that can lead to serious injury or even, loss of life. The present work explores rapid electrochemical impedance spectroscopy (EIS) coupled with gas sensing technology as diagnostics to monitor cells and packs for failure markers. These failure markers can then be used for onboard assessment of SoS. Experimental results explore key changes in single cells and packs undergoing thermal or electrical abuse. Rapid EIS showed longer warning times, followed by VOC sensors, and then H 2 sensors. While rapid EIS gives the longest warning time, with the failure marker often appearing before the cell vents, the reliability of identifying impedance changes in single cells within a pack decreases as the pack complexity increases. This provides empirical evidence to support the significant role that cell packaging and battery engineering intricacies play in monitoring the SoS.

25 ENERGY STORAGE↗

Hydropower Biological Evaluation Toolset Best Practice Guide

Field studies using live fish are necessary for the evaluation of turbine biological performance, but they cannot determine the specific hydraulic conditions or physical stresses experienced by the fish, the locations where deleterious conditions occur, or the specific causes of the biological response. Using the Sensor Fish (SF) sensing technology, this deficiency can be overcome because the SF can be released independently or concurrently with live fish directly into operating infrastructure, and it takes high-frequency measurements of hydraulic conditions such as pressure, acceleration, and rotation acting on a body in situ during downstream passage. The Hydropower Biological Evaluation Tools (HBET; Hou et al. 2018) software package, developed by Pacific Northwest National Laboratory (PNNL), is designed to assemble, organize, and process data collected by the PNNL-developed SF and by live fish. HBET was developed specifically to design SF field studies, process the raw data, and analyze the processed data efficiently and scientifically. Its objectives are to facilitate SF studies focused on characterizing hydraulic conditions and to apply SF data for evaluating the impacts on fish from passage through hydro-structures. HBET allows users to design new studies, analyze data, perform statistical analyses, and evaluate predicted biological responses. It can be used by researchers, turbine designers, hydropower operators, and regulators to evaluate hydro-structures to enhance environmental sustainability in a cost-effective manner.

13 HYDRO ENERGY↗

Rugged Target Standards for HSI Remote Sensing

There is a need for stable test standards for many remote sensing applications that can be used both in the laboratory and in rugged test environments. Ideally these standards would be stable over time such that the same standard could be used from year to year for comparison of system performance. While ink-jet and spray gun methods can disperse controlled doses of dissolved analytes, methods to maintain particle size spectral variations are lacking. In addition, standards that are environmentally robust and stable over time are limited. As part of the recent Lighthouse work toward a Hyperspectral Imagery (HSI) proximal handheld sensor, Special Technologies Laboratory (STL) was tasked to do preliminary work toward a rugged, transportable, waterproof target board. This involved developing test standards using minerals of known particle sizes that have spectrally relevant features. Mineral powders were dispersed in binders that did not change their spectral characteristics. These standards were packaged such that they could be transported and used repeatedly. This paper discusses the methodology for developing this preliminary set of targets. Target sizes were limited to the proximal case, and further work is required to finalize the optimum binder and examine other possible appropriate minerals.

target standards, hyperspectral, minerals, analyte↗

Dichroic beamsplitter for high energy laser diagnostics

Wavefront control techniques are provided for the alignment and performance optimization of optical devices. A Shack-Hartmann wavefront sensor can be used to measure the wavefront distortion and a control system generates feedback error signal to optics inside the device to correct the wavefront. The system can be calibrated with a low-average-power probe laser. An optical element is provided to couple the optical device to a diagnostic/control package in a way that optimizes both the output power of the optical device and the coupling of the probe light into the diagnostics.

47 OTHER INSTRUMENTATION↗

Temporal Characterization and Filtering of Sensor Data to Support Anomaly Detection

Here, we present an approach for characterizing complex temporal behavior in the sensor measurements of a system in order to support detection of anomalies in that system. We first characterize typical behavior by extending a hidden Markov model-based approach to time series alignment. We then use a trace of that learned behavior to develop a particle filter that enables efficient estimation of the filtering distribution on the state space. This produces filtered residuals that can then be used in an anomaly detection framework. Our motivating example is the daily behavior of a building’s heating, ventilation, and air conditioning (HVAC) system, using sensor measurements that arrive every minute and induce a state space with 15,120 states. We provide an end-to-end demonstration of our approach showing improved performance of anomaly detection after application of alignment and filtering compared to the unaligned data. The proposed model is implemented as a computationally efficient R package alignts (align time series) built with R and Fortran 95 with OpenMP support.

47 OTHER INSTRUMENTATION↗

ADVANCING THE TRANSPORTATION – SECURITY, TRACKING, AND REPORTING (T-STAR) SYSTEM

The Transportation – Security, Tracking and Reporting (T-STAR) System was developed by NNSA NA-21 Office of Radiological Security (ORS) to provide a transportation security system for use during transport of Category 1 and Category 2 radiological material to provide detection and tracking capability for shipments. While many off the shelf systems provide asset tracking of the conveyance, few offer detection of a breach into the cargo compartment or the removal of cargo from the conveyance. Systems that do offer such capability need to be permanently installed on the conveyance, requiring drilling of holes and running of cables throughout the conveyance itself. This means that dedicated shipping containers or vehicles are required, and this is not sustainable in many countries where ORS is building capacity for the security of radioactive materials in use, storage, and in transport. T-STAR is leveraging various ORNL technologies for improved communications capability and reduced power requirements; the multimode communications module developed by the Unmanned Aerial Systems group and the low power and extensible Authenticatable Container Tracking System (ACTS) tag developed for the US Department of Energy’s Packaging Certification Program provide a small footprint tracking system which can be installed quickly as needed. T-STAR uses a cellular and an Iridium modem to communicate configuration and alert information to a server used to monitor the shipment and incorporates a Z-wave © wireless security system allowing various intrusion detection sensors to be located in the conveyance. The Z-wave sensors are readily available, inexpensive, and power efficient, making them replaceable and low maintenance. The server software be configured as a standalone system installed on a light duty computer hosted by the competent authority, carrier, or response agency, or hosted as part of an Amazon Cloud Server (AWS) accessible via a secure login. The server has two functions, first is to handle messages to/from the T-STAR field unit, second is to host the user interface which can be accessed using a web browser on desktop or mobile device. The user interface implements roles to determine the level of access to shipment information, define geo-fences, and configure notifications. The user interface also supports multiple languages for display as well as notifications by using a simple lookup file which can be modified by the host country to ensure translations are correct and meaningful to responders receiving notifications and alerts. This paper will detail the overarching T-STAR capabilities, architecture and components, and provide insights on how it is deployed, used, and monitored during transportation of radioactive material.

Schultze, Michael↗

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗

Detection of special nuclear materials with the associate particle technique

In the frame of the French trans-governmental R and D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soil temperature and soil moisture raw data, permafrost table depths, and accompanying environmental variable data, Kenai Wildlife Refuge, 2019-2022

Data package purpose: This data package was created to contain all data used in an upcoming article, "Canopy Cover and Microtopography Control Precipitation-Enhanced Thaw of Ecosystem-Protected Permafrost." In review.This data package includes: Raw output from 19 distributed temperature profilers with a thermistor every 10 cm along a 160 cm length at a measurement interval of 15 minutes (.CSV). Raw output from two soil moisture and temperature profilers (90 cm length and 120 cm length) that took composite soil moisture readings every 15 cm along the sensor length at a measurement interval of 30 minutes (.CSV). Permafrost depths were measured annually in mid-September at DTP sensor locations (.CSV) and along an across-site transect (.CSV). Environmental variables (snow depth, canopy closure, moss depth, and elevation) for all sensor locations. Real-time kinetic (RTK) GPS points showing site microtopography (.CSV).Analysis software: Our analysis was done in Matlab. File types can be used with any software.

54 ENVIRONMENTAL SCIENCES↗

FRAMES Metadata Reporting Templates for Ecohydrological Observations, version 1.1

FRAMES is a a set of Excel metadata files and package-level descriptive metadata that are designed to facilitate and improve capture of desired metadata for ecohydrological observations. The metadata are bundled with data files into a data package and submitted to a data repository (e.g. the NGEE Tropics Data Repository) via a web form. FRAMES standardizes reporting of diverse ecohydrological and biogeochemical data for synthesis across a range of spatiotemporal scales and incorporates many best data science practices. This version of FRAMES supports observations for primarily automated measurements collected by permanently located sensors, including sap flow (tree water use), leaf surface temperature, soil water content, dendrometry (stem diameter growth increment), and solar radiation. Version 1.1 extend the controlled vocabulary and incorporates functionality to facilitate programmatic use of data and FRAMES metadata (R code available at NGEE Tropics Data Repository).

54 ENVIRONMENTAL SCIENCES↗

The impact of incorporating shell-corrections to energy loss in silicon

Modern silicon tracking detectors based on hybrid or fully integrated CMOS technology are continuing to push to thinner sensors. The ionization energy loss fluctuations in very thin silicon sensors significantly deviates from the Landau distribution. Therefore, we have developed a charge deposition setup that implements the Bichsel straggling function, which accounts for shell-effects. This enhanced simulation is important for comparing with testbeam or collision data with thin sensors as demonstrated by reproducing more realistically the degraded position resolution compared with naïve ionization models based on simple Landau-like fluctuation. Our implementation of the Bichsel model agrees well with the multipurpose photo absorption ionization (PAI) model in Geant4 and is significantly faster. The code is made publicly available as part of the Allpix software package in order to facilitate predictions for new detector designs and comparisons with testbeam data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Series Surface Temperature of Variably Inundated Sediment across 30 North American Rivers

This dataset supports a broader study examining drivers of organic matter chemistry in variably inundated hyporheic zone sediments and further linking that chemistry to biogeochemical rates. The dataset provides surficial temperature time series that can be used to infer the dynamics of inundation prior to the collection of sediments. Those inferred inundation histories can then be used to help interpret variation in the organic matter chemistry. There are related data that will be published, such as FTICR-MS data on organic matter chemistry and sediment moisture. A data package with those data is forthcoming.This dataset is comprised of two folders: (1) ECA1_iButtonData and (2) ECA1_SitePhotos. The ECA1_iButtonData folder contains: (1) file-level metadata, (2) data dictionary, (3) field metadata, (4) installation methods, (5) iButton deployment protocol, (6) readme, and (7) folder of individual time series temperature csv files for each iButton sensor deployed. The ECA1_SitePhotos folder contains site photographs taken in the field. All files are .csv, .txt, .pdf, or .jpg.

54 ENVIRONMENTAL SCIENCES↗

A Highly Miniaturized Cloud and Aerosol Instrument Package for Small UAS's

Unmanned Aerial Systems (UAS’s), which include Unmanned Aerial Vehicles (UAV’s) and tethered balloon systems (TBS) offer significant advantages over conventional research aircraft. They are capable of long-duration measurements of cloud properties in regions where piloted aircraft are unsafe, e.g., at very low altitudes over remote regions, such as tundra and open ocean. TBS and UAV’s are now widely recognized as a technology that can provide unprecedented insights into cloud and radiation processes, but development of miniature sensors capable of providing sophisticated measurements of cloud, aerosol and radiative properties lag behind. In Phase II of this SBIR research, Stratton Park Engineering Company, Inc. (SPEC) designed and fabricated a miniature combination optical particle probe (micro-COPP) that is capable of being flown on small UAV’s and TBS. The micro-COPP measures the size distribution of cloud particles from 2 microns to several millimeters and records high-definition images that distinguish ice particle from water drops, which is essential in mixed-phase clouds. The micro-COPP was installed along with miniature instruments to measure aerosols, cloud condensation nuclei, position and atmospheric state parameters on a small UAV and TBS that were deployed in the Arctic at the Ny-Ålesund, Svalbard (78° N. latitude).

54 ENVIRONMENTAL SCIENCES↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

DarkNESS Project Testing

This internship involved the design and assembly of a mechanical system for testing skipper-Charge Couple Devices (CCDs) for the DarkNESS project. Skipper-CCDs are highly-sensitive sensors with ultra-low readout noise that are deployed for direct detection of dark matter. DarkNESS is a CubeSat that aims to use skipper CCDs to search for dark matter decaying into X-rays. Currently, in the testing phase, the design process involved creating 3D models of mechanical adapters to operate a prototype space Multi Chip Module (sMCM) package in existing testing chambers in the CCD lab at Fermilab's IERC. The drawings were sent out to be machined, and while waiting to receive the finished adapters, we assembled a vacuum chamber for skipper-CCD testing and performed initial testing of a single CCD controlled by the space Low Threshold Acquisition (sLTA) board that will be employed on the CubeSat. The results showed that the testing conditions are optimal for data to start being taken and analyzed.

Akouedjinoude, Kodjo↗

Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗