Production of Neutron-Rich Bi Isotopes by Electric Fields

The short time (approx10 minutes) high voltage electrolysis of nitrate bismuth solution was performed. After electrolysis about 30 mg of electrolyte have been dried up on a thin polyethylene film. The sample obtained was placed into the detecting system (Si detector and plastic detector). Alpha-radioactivity of the sample was measured. The results showed that alpha-radioactivity increased about 100 times to the base level. The radioactivity decreasing was about 2 times for 50 minutes. Some signals from the Si detector was accompanied by a signal from the electron detector (22 events). The signal from the plastic detector for all the events the electron recorded preceded the Si detector signal with delay less than 1.4 musec. The conclusion was made that beta-decay of nuclei {sup 212}Bi and the subsequent alpha-decay of nuclei {sup 212}Po were recorded. The effect was reproduced in 28 experiments. The possible explanation of the phenomenon was given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection Efficiency of a ToF Spectrometer from Heavy-Ion Elastic Recoil Detection

The detection efficiency of a time-of-flight system based on two micro-channel plates (MCP) time zero detectors plus a conventional silicon surface barrier detector was obtained from heavy ion elastic recoil measurements (this ToF spectrometer is mainly devoted to measurements of total fusion cross section of weakly bound projectiles on different mass-targets systems). In this work we have used beams of {sup 7}Li, {sup 16}O, {sup 32}S and {sup 35}Cl to study the mass region of interest for its application to measurements fusion cross sections in the {sup 6,7}Li+{sup 27}Al systems at energies around and above the Coulomb barrier (0.8V{sub B{<=}}E{<=}2.0V{sub B}). As the efficiency of a ToF spectrometer is strongly dependent on the energy and mass of the detected particles, we have covered a wide range of the scattered particle energies with a high degree of accuracy at the lowest energies. The different experimental efficiency curves obtained in that way were compared with theoretical electronic stopping power curves on carbon foils and were applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studying {sup 12}B via {sup 8}Li-{alpha} resonant scattering

The inverse kinematics thick target scattering method (TTIK) has been used to study the {sup 8}Li elastic scattering on {sup 4}He in order to investigate {sup 8}Li-{alpha} cluster configurations in excited states of {sup 12}B. A {sup 8}Li beam, provided by the radioactive beam facility EXCYT, at E{sub beam} = 30.6 MeV, passing through helium thick target, continuously decreases its energy inducing elastic scattering starting from the initial energy down to zero. Four {Delta}E-E double stage silicon detector telescopes were used to detect the recoil {alpha}-particles coming from the scattering. Event by event time measurement between beam particles passing through a MCP detector and {alpha}-particles impinging on {Delta}E stage allows elastic from inelastic events discrimination, thus representing an improvement of the TTIK method. In this paper the used experimental technique and some preliminary results will be briefly described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The {sup 28}Si(p,t){sup 26}Si{sup *}(p) reaction and implications for the astrophysical {sup 25}Al(p,{gamma}){sup 26}Si reaction rate

Several resonances in {sup 25}Al(p,{gamma}){sup 26}Si have been studied via the {sup 28}Si(p,t){sup 26}Si reaction. Triton energies and angular distributions were measured using a segmented annular detector array. An additional silicon detector array was used to simultaneously detect the coincident protons emitted from the decay of states in {sup 26}Si above the proton threshold in order to determine branching ratios. A resonance at 5927{+-}4 keV has been experimentally confirmed as the first l=0 state above the proton threshold, with a proton branching ratio consistent with one.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

E-Beam Electron Mobility Study on CZT and CsI

There is much interest in developing new scintillator detectors for radiation detection and radiographic imaging applications. The knowledge of the electron mobility ({mu}) is important in the basic understanding of charge transport and in the selection and optimization of many inorganic scintillator materials such as thallium-doped cesium iodide, CsI(Tl). Performance measures are used to model various scintillator responses in an effort to predict the effect of doping concentrations. Performance models will help in the new scintillator design process. Initial tests are done with cadmium zinc telluride detectors to establish measurement techniques and baselines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

Solid Xenon Project

Crystals like Germanium and Silicon need to be grown in specialized facilities which is time and money costly. It takes many runs to test the detector once it's manufactured and mishaps are very probable. It is of a great challenge to grow big germanium crystals and that's why stacking them up in a tower is the only way at the moment to increase testing mass. Liquid Noble gas experiments experiencing contamination problems, their predicted energy resolution at 10 keV and lower energy range is not as good as predicted. Every experiment is targeting one specific purpose, looking for one thing. Why not to design an experiment that is diverse and build a detector that can search for Dark Matter, Solar Axions, Neutrinoless Double Beta decay, etc. Solid Xenon detector is such detector. We designed a simple Xenon crystal growing chamber that was put together at Fermi National Accelerator Laboratory. The first phase of this experiment was to demonstrate that a good, crack free Xenon crystal can be grown (regardless of many failed attempts by various groups) and our first goal, 1 kg crystal, was successful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phonon emission in germanium and silicon by electrons and holes in applied electric field at low temperature

The cryogenic dark matter search employs Ge and Si detectors to search for weakly interacting massive particle dark matter via its elastic-scattering interactions with nuclei while discriminating against interactions of background particles. These detectors distinguish nuclear recoils from electron recoils by simultaneously measuring phonon and ionization production in semiconducting substrates at sub-kelvin temperatures. They also reconstruct event position by quadrant-segmented measurement of the phonon signal. The ionization drift field does work on the electrons and holes. The charge carriers radiate this energy as acoustic phonons. At the typical applied field of 300 V/m in Ge (400 V/m in Si), we self-consistently model the behavior of the electrons and holes using independent drifted Maxwellian distributions, each characterized by an average drift velocity and an effective temperature, and including acoustic phonon emission. We calculate the phonon power angular and frequency distributions. We find that the bias polarity affects these distributions and, therefore, the phonon collection efficiency in Ge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous photoresponse of GaN x-ray Schottky detectors

GaN based materials are believed to be very stable materials, in particular, under irradiation by high energy photons such as x rays. We have studied x-ray detectors based on GaN Schottky diodes. Vertical Schottky diodes were fabricated based on a 20 mum thick undoped GaN layer grown on a conductive GaN substrate. Their photoresponse to near UV light and to x rays was measured. While the response to near UV light was fast and linear as expected, anomalous behaviors were observed under x-ray illumination. The photocurrent increases as the third power of the incident x-ray flux. The photocurrent transient when the x rays is turned on are long and nonexponential (S shape) and strongly differs from the off transient which is fast and exponential. Also, a very strong quenching of the x-ray photoresponse is observed when the detector is simultaneously illuminated with visible light. All of these anomalous behaviors are explained in the frame of a complete model involving traps and tunnel currents. A reasonable quantitative agreement between the model and the experimental data is obtained.

36 MATERIALS SCIENCE↗

Chemical vapor deposition diamond based multilayered radiation detector: Physical analysis of detection properties

Recently, solid state photovoltaic Schottky diodes, able to detect ionizing radiation, in particular, x-ray and ultraviolet radiation, have been developed at the University of Rome 'Tor Vergata'. We report on a physical and electrical properties analysis of the device and a detailed study of its detection capabilities as determined by its electrical properties. The design of the device is based on a metal/nominally intrinsic/p-type diamond layered structure obtained by microwave plasma chemical vapor deposition of homoepitaxial single crystal diamond followed by thermal evaporation of a metallic contact. The device can operate in an unbiased mode by using the built-in potential arising from the electrode-diamond junction. We compare the expected response of the device to photons of various energies calculated through Monte Carlo simulation with experimental data collected in a well controlled experimental setup i.e., monochromatic high flux x-ray beams from 6 to 20 keV, available at the Diamond Light Source synchrotron in Harwell (U.K.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-gamma spectroscopy of the (p,d-gamma){sup 155}Gd reaction: Neutron single-quasiparticle states at N=91

A segmented Si telescope and HPGe array is used to study the {sup 156}Gd(p,d-gamma){sup 155}Gd direct reaction by d-gamma and d-gamma-gamma coincidence measurements using 25-MeV protons. The present investigation is the first time that this N=91 nucleus and the N=90 region--which is known for a rapid change from vibrational to rotational character, several low-lying 0{sup +} states in the even-even nuclei, and large Coriolis (DELTAOMEGA=1) plus DELTAN=2 mixing in the even-odd nuclei--have been studied by particle-gamma coincidence following a direct reaction with light ions. Gamma-ray energies and branches, excitation energies, angular distributions, and cross sections are measured for states directly populated in the (p,d) reaction. A new low-energy doublet state at 592.46 keV (previously associated with the K=0 x (3/2){sup -}[521] bandhead) and several new gamma-ray transitions (particularly for states with excitation energies >1 MeV) are presented. Most notably, the previous nu (7/2){sup +}[404] systematics at and around the N=90 transition region are brought into question and reassigned as nu (5/2){sup +}[402]. This reassignment makes the nu (1/2){sup +}[400], nu (3/2){sup +}[402], and nu (5/2){sup +}[402] orbitals, which originate from the 3s{sub 1/2}, 2d{sub 3/2}, and 2d{sub 5/2} spherical states, respectively, responsible for the three largest cross sections to positive-parity states in the (p,d){sup 155}Gd direct reaction. These three steeply upsloping orbitals undergo DELTAN=2 mixing with their N=6 orbital partners, which are oppositely sloped with respect to deformation. The presence of these steeply sloped and crossing orbitals near the Fermi surface could weaken the monopole pairing strength and increase the quadrupole pairing strength of neighboring even-even nuclei, which would bring nu 2p-2h 0{sup +} states below 2DELTA. Indeed, this could account for a large number of the low-lying 0{sup +} states populated in the (p,t){sup 154}Gd direct reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

Velocity map imaging using an in-vacuum pixel detector

The use of a new type in-vacuum pixel detector in velocity map imaging (VMI) is introduced. The Medipix2 and Timepix semiconductor pixel detectors (256x256 square pixels, 55x55 {mu}m{sup 2}) are well suited for charged particle detection. They offer high resolution, low noise, and high quantum efficiency. The Medipix2 chip allows double energy discrimination by offering a low and a high energy threshold. The Timepix detector allows to record the incidence time of a particle with a temporal resolution of 10 ns and a dynamic range of 160 {mu}s. Results of the first time application of the Medipix2 detector to VMI are presented, investigating the quantum efficiency as well as the possibility to operate at increased background pressure in the vacuum chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of cross sections for inelastic cold-neutron scattering in metals and polymers by the method of (n, {gamma}) analysis

The results obtained by measuring the cross sections for the inelastic scattering of very cold neutrons for a number of metals and polymers by the method of a neutron-irradiation analysis are presented. The method is based on simultaneously measuring events of inelastic scattering and neutron capture in the sample under investigation via recording gamma radiation with a semiconductor germanium detector. Neutron capture by a nucleus of the sample is accompanied by the prompt radiation of gamma rays having a known spectrum. Upon inelastic scattering, a neutron acquires thermal energy. Upon leaving the sample, this neutron is absorbed in a special converter that contains the isotope {sup 10}B. The capture of the neutron by a {sup 10}B nucleus is followed by the emission of a 477-keV gamma ray. The probabilities of capture and inelastic scattering are proportional to the respective neutron-interaction cross sections, and the ratio of the recorded detector counts corresponding to events of the two types does not depend on the spectrum of the incident flux of very cold neutrons or on the trajectory of neutron motion in the sample. The sought inelastic-scattering cross section at a fixed sample temperature is calculated by using this ratio and the known cross section for neutron capture by the sample isotope having a known gamma-radiation spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗