Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Scanning mechanism study for multi-frequency microwave radiometers

Scanning mode for a microwave radiometer having large aperture antenna is determined from scientific needs by engineering tradeoffs. Two configurations of the scan drive mechanism with an integral momentum compensation are formulated for 1.OM and 1.4M diameter antennas. As the formulation is based on currently available components, it is possible to design and fabricate the formulated mechanism without new hardware development. A preliminary specification for major components of formulated drives is also included in the report.

Shin, I.↗

An antenna for limited scan in one plane - Design criteria and numerical simulation

Aperture illumination is synthesized through the use of overlapping subarrays with independently controlled excitations. Detailed analysis and design criteria are provided for a specific limited-scan antenna configuration scanning in one plane. The number of phase shifts is the theoretical minimum corresponding to specified aperture size and field of view. Beam pointing and width are approximately constant for moderate frequency variation, and ultralow sidelobes outside the field of view can be produced at the cost of a slight loss of illumination efficiency. Accurate aperture illumination control makes for excellent independently specified sum and difference patterns in beamforming.

Borgiotti, G. V.↗

Estimating regional heat flux from scanning radiometer data

Method using matrix approach to determine best linear estimate of total flux consistent with condition of minimum variance proves useful in meteorological studies. It is useful for researchers studying options in scanner design such as scan pattern, scan rate, and radiometer field-of-view.

Bess, T. D.↗

Torque-while-turnaround scan mirror assembly

A scan mirror assembly which is part of a thematic mapper system is described with emphasis on mechanical aspects of the design. Features of the oscillating scan mirror mechanism include: a low level of structural vibration for the impact energies involved in mirror oscillation and return of energy lost during impact to the mirror by applying torque during the instant of impact.

Starkus, C. J.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

The remote measurement of tornado-like flows employing a scanning laser Doppler system

The paper deals with a scanning laser Doppler velocimeter system employed in a test program for measuring naturally occurring tornado-like phenomena, known as dust devils. A description of the system and the test program is followed by a discussion of the data processing techniques and data analysis. The system uses a stable 15-W CO2 laser with the beam expanded and focused by a 12-inch telescope. Range resolution is obtained by focusing the optical system. The velocity of each volume of air (scanned in a horizontal plane) is determined from spectral analysis of the heterodyne signal. Results derived from the measurement program and data/system analyses are examined.

Jeffreys, H. B.↗

Nondestructive determination of the depth of planar p-n junctions by scanning electron microscopy

A method was developed for measuring nondestructively the depth of planar p-n junctions in simple devices as well as in integrated-circuit structures with the electron-beam induced current (EBIC) by scanning parallel to the junction in a scanning electron microscope (SEM). The results were found to be in good agreement with those obtained by the commonly used destructive method of lapping at an angle to the junction and staining to reveal the junction.

Chi, J.-Y.↗

Research in pilot scanning behavior

A NASA-developed oculometer, which measures pilot scanning behavior, is described in terms of design and operating parameters. Results are presented of tests conducted in a terminal configured vehicle (TVC) aft cockpit simulator, involving pilots making simulated instrument approaches. Attention is given to the amount of time the pilots spend scanning the SFD and EADI CRT displays, and to differences resulting from both the physical location of the CRTs (within a 30 x 30 x 30 cm space), and from their intrinsic characteristics.

Waller, M. C.↗

System considerations for an earth radiation budget scanning radiometer

The objective of the scanning radiometer of the Earth Radiation Budget Satellite System is to measure the longwave and reflected shortwave radiation from the earth on a gridwork of approximately 250 km square regions in order to obtain one-month averages of flux with global coverage to an accuracy of 14 W/sq m. A number of considerations in the choice of some of the design parameters of the scanner are discussed. The error sources which must be considered in the design of a scanning radiometer designed to measure regional radiation budget are examined. An analysis of the system performance through spatial averaging is presented. The analysis provides insight into the effects of field of view, time response, onboard processing and spatial averaging.

Smith, G. L.↗

Stereographic cloud heights from the imagery of two scan-synchronized geostationary satellites

Scan synchronization of the sensors of two SMS-GOES satellites yields imagery from which cloud heights can be derived stereographically with a theoretical two-sigma random uncertainty of + or - 0.25 km for pairs of satellites separated by 60 degrees of longitude. Systematic height errors due to cloud motion can be kept below 100 m for all clouds with east-west components of speed below hurricane speed, provided the scan synchronization is within 40 seconds at the mid-point latitude, and the spin axis of each satellite is parallel to that of the earth.

Minzner, R. A.↗

System considerations for an earth radiation budget scanning radiometer

Error sources that might affect the earth radiation budget (ERBSI) scanner radiometer are discussed. Effects of sensor time response, spatial averaging by the field of view, onboard processing, and level III averaging are examined, coverage of grid regions is considered, and an analysis procedure for a scanning radiometer is derived. ERBSI consists of a scanning radiometer, sensors, and a solar radiometer, and it is suggested that ERBSI be included in the instrument complement of NOAA operational spacecraft.

Smith, G. L.↗

A linear scanning balloon-borne telescope for far-infrared astronomy

A low-background balloon-borne far-infrared (30-300 microns) telescope, utilizing a linear scan mode has dramatically increased the efficiency of mapping large extended areas over more conventional systems. The system consists of a 20 cm linear scanned mirror mounted as an off-axis (Herchelian) telescope designed to achieve an emissivity of 1% or less, a ten position cooled aperture-filter wheel, a cooled Pfund optical system with a composite diamond-germanium bolometer mounted in a spherical cavity, a minimum phase shift ultra-low frequency amplifier, and a 4 micron thick mylar dewar window. This system was used to produce detailed far-infrared maps of the galactic plane. The system specifications and operating parameters will be discussed and preliminary data shown.

Nishimura, T.↗

Antenna pattern correction procedures for the Scanning Multichannel Microwave Radiometer /SMMR/

Procedures for correcting antenna temperature measurements and retrieving the true brightness temperatures are developed for the Scanning Multichannel Microwave Radiometer (SMMR) flown on the Seasat-A and Nimbus-G satellites. These procedures are necessary to meet the measurement accuracies required for deriving sea surface temperatures and wind speeds. It is shown that sidelobe contributions and polarization cross-coupling are major effects to be accounted for, in addition to some unique features of the SMMR instrument such as integration times and antenna scan characteristics. Methods are presented for data averaging and data reformatting, these are to be used with geophysical parameter retrieval algorithms.

Njoku, E. G.↗

A laser rangefinder path selection system for Martian rover using logarithmic scanning scheme

This paper deals with a laser rangefinder path selection scheme for an autonomous Martian roving vehicle. The overall scheme consists of the following interrelated sub-systems; logarithmic scanning sub-system, obstacle detection scheme (Sonalkar and Shen (1975); Kim and Shen (1978)), terrain modeling and estimation (Shen and Stare (1977); Pawlowski (1978)), and path selection algorithm (Netch and Shen (1977)). Independent and separate studies for the last three sub-systems were performed previously. With the introduction of the logarithmic scanning, an integrated study is completed in this paper. This study serves as a possible alternate choice other than TV cameras for navigating the Martian surface. Moreover, if hybrid TV and laser systems are used, a laser-only standby system can be put to work in case the TV part of the hybrid system fails to operate.

Shen, C. N.↗

Infrared scans of Jupiter

Spatial scans at eight wavelengths between 7.8 and 24 microns along Jupiter's meridian and along the Equatorial Zone, the North Equatorial Belt, and the South Tropical Zone are considered. Some features of these scans are differences in brightness temperatures between the Great Red Spot and the surrounding South Tropical Zone, a higher temperature at high northern latitudes than high southern latitudes, equal or possibly higher temperatures of zones than belts at 7.8 microns in contrast to higher temperatures of belts at other observed wavelengths, very strong limb darkening at 8.9 microns possibly due to a large scale height or a nonuniform distribution of solid NH3 particles, and inhomogeneities within belts and zones.

Sinton, W. M.↗

Infrared scans of Saturn

Scans are presented at five wavelengths between 7.8 and 25 microns north-south along Saturn's central meridian and east-west parallel to the equator through the subearth point. The brightening of Saturn's South Pole at 12.7 microns was more enhanced in 1977 than in 1978 due to the 5 deg greater declination of the polar axis in 1977. There is a plateau in the Southern Hemisphere between -30 and -60 deg latitude in the 7.8 and 12.7 micron scans. The apparent temperature of the rings decreased as Saturn approached the equinox. It is found generally that the strongest ring emission arises from the C ring.

Sinton, W. M.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗