Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Tuning the spin dynamics and magnetic phase transitions of the Cantor alloy via composition and sample processing protocols: A muon spin relaxation study

CrMnFeCoNi, also called the Cantor alloy, is a well-known high-entropy alloy whose magnetic properties have recently become a focus of attention. Here, we present a detailed muon spin relaxation study of the influence of chemical composition and sample processing protocols on the magnetic phase transitions and spin dynamics of several different Cantor alloy samples. Specific samples studied include a pristine equiatomic sample, samples with deficient and excess Mn content, and equiatomic samples magnetized in a field of 9 T or plastically deformed in pressures up to 0.5 GPa. The results confirm the sensitive dependence of the transition temperature on composition and demonstrate that post-synthesis pressure treatments cause the transition to become significantly less homogeneous throughout the sample volume. In addition, we observe critical spin dynamics in the vicinity of the transition in all samples, reminiscent of canonical spin glasses and magnetic materials with ideal continuous phase transitions. Application of an external magnetic field suppresses the critical dynamics in the Mn-deficient sample, while the equiatomic and Mn-rich samples show more robust critical dynamics. The spin-flip thermal activation energy in the paramagnetic phase increases with Mn content, ranging from 3.1⁢(3) × 10 -21 J for 0% Mn to 1.2⁢(2) × 10 -20 J for 30% Mn content. These results shed light on critical magnetic behavior in environments of extreme chemical disorder and demonstrate the tunability of spin dynamics in the Cantor alloy via chemical composition and sample processing.

36 MATERIALS SCIENCE↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

Soil Sample Plan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit, Part V, Special Condition #14 a-f. August 2020

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semivolatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 2 and 3. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Tank 38H (HTF-38-23-95, -96) and Tank 43H (HTF-43-23-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased significantly from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions versus the previous subsurface sample. However, the 38H subsurface sample shows higher concentrations of Al, Ca, Fe, Mn, and Si vs. the previous Tank 38H subsurface sample. The current Tank 38H subsurface sample contained visible sludge solids in excess of the previous sample based on visual appearance. Weight percent solids measurements indicate presence of 3.0 ± 0.1 wt.% insoluble solids in the Tank 38H subsurface sample. The significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within the Tank 38H. Savannah River Mission Completion (SRMC) personnel indicated that there were no tank-to-tank transfers into Tank 38H since early January 2023 and the 2H (16H) Evaporator was shut down on 3/26/2023 and has not operated since that time. There have been many pumped non-waste transfers of water from the H-Area diversion box 7 (HDB-7) sump into Tank 38 since the 3/26/2023 date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Photometric Redshift Estimates with Training Sample Augmentation

Abstract Large imaging surveys will rely on photometric redshifts (photo- z 's), which are typically estimated through machine-learning methods. Currently planned spectroscopic surveys will not be deep enough to produce a representative training sample for Legacy Survey of Space and Time (LSST), so we seek methods to improve the photo- z estimates that arise from nonrepresentative training samples. Spectroscopic training samples for photo- z 's are biased toward redder, brighter galaxies, which also tend to be at lower redshift than the typical galaxy observed by LSST, leading to poor photo- z estimates with outlier fractions nearly 4 times larger than for a representative training sample. In this Letter, we apply the concept of training sample augmentation, where we augment simulated nonrepresentative training samples with simulated galaxies possessing otherwise unrepresented features. When we select simulated galaxies with ( g - z ) color, i -band magnitude, and redshift outside the range of the original training sample, we are able to reduce the outlier fraction of the photo- z estimates for simulated LSST data by nearly 50% and the normalized median absolute deviation (NMAD) by 56%. When compared to a fully representative training sample, augmentation can recover nearly 70% of the degradation in the outlier fraction and 80% of the degradation in NMAD. Training sample augmentation is a simple and effective way to improve training samples for photo- z 's without requiring additional spectroscopic samples.

Moskowitz, Irene (ORCID:0000000222068589)↗

Production rate calibration for cosmogenic 10 Be in pyroxene by applying a rapid fusion method to 10 Be-saturated samples from the Transantarctic Mountains, Antarctica

Measurements of multiple cosmogenic nuclides in a single sample are valuable for various applications of cosmogenic nuclide exposure dating and allow for correcting exposure ages for surface weathering and erosion and establishing exposure–burial history. Here we provide advances in the measurement of cosmogenic 10 Be in pyroxene and constraints on the production rate that provide new opportunities for measurements of multi-nuclide systems, such as 10 Be/ 3 He, in pyroxene-bearing samples. We extracted and measured cosmogenic 10 Be in pyroxene from two sets of Ferrar Dolerite samples collected from the Transantarctic Mountains in Antarctica. One set of samples has 10 Be concentrations close to saturation, which allows for the production rate calibration of 10 Be in pyroxene by assuming production–decay equilibrium. The other set of samples, which has a more recent exposure history, is used to determine if a rapid fusion method can be successfully applied to samples with Holocene to Last Glacial Maximum exposure ages. From measured 10 Be concentrations in the near-saturation sample set we find the production rate of 10 Be in pyroxene to be 3.74 ± 0.10 atoms g -1 yr -1 , which is consistent with 10 Be/ 3 He paired nuclide ratios from samples assumed to have simple exposure. Given the high 10 Be concentration measured in this sample set, a sample mass of ~ 0.5 g of pyroxene is sufficient for the extraction of cosmogenic 10 Be from pyroxene using a rapid fusion method. However, for the set of samples that have low 10 Be concentrations, measured concentrations were higher than expected. We attribute spuriously high 10 Be concentrations to failure in removing all meteoric 10 Be and/or a highly variable and poorly quantified procedural blank background correction.

58 GEOSCIENCES↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

The extended 12 micron galaxy sample

We have selected an all-sky (absolute value of b greater than or equal to 25 deg) 12 micron flux-limited sample of 893 galaxies from the IRAS Faint Source Catalog, Version 2 (FSC-2). We have obtained accurate total fluxes in the IRAS wavebands by using the ADDSCAN procedure for all objects with FSC-2 12 micron fluxes greater than 0.15 Jy and increasing flux densities from 12 to 60 microns, and defined the sample by imposing a survey limit of 0.22 Jy on the total 12 micron flux. Its completeness is verified, by means of the classical log N - log S and V/V(sub max) tests, down to 0.30 Jy, below which we have measured the incompleteness down to the survey limit, using the log N - log S plot, for our statistical analysis. We have obtained redshifts (mostly from catalogs) for virtually all (98.4%) the galaxies in the sample. Using existing catalogs of active galaxies, we defined a subsample of 118 objects consisting of 53 Seyfert 1s and quasars, 63 Seyfert 2s, and two blazars (approximately 13% of the full sample), which is the largest unbiased sample of Seyfert galaxies ever assembled. Since the 12 micron flux has been shown to be about one-fifth of the bolometric flux for Seyfert galaxies and quasars, the subsample of Seyferts (including quasars and blazars) is complete not only to 0.30 Jy at 12 microns but also with respect to a bolometric flux limit of approximately 2.0 x 10(exp -10) ergs/s/sq cm. The average value of V/V(sub max) for the full sample, corrected for incompleteness at low fluxes, is 0.51 +/- 0.04, expected for a complete sample of uniformly distributed galaxies, while the value for the Seyfert galaxy subsample is 0.46 +/- 0.10. We have derived 12 microns and far-infrared luminosity functions for the AGNs, as well as for the entire sample. We extracted from our sample a complete subsample of 235 galaxies flux-limited (8.3 Jy) at 60 microns. The 60 micron luminosity function computed for this subsample is in satisfactory agreement with the ones derived from the bright galaxy sample (BGS) and the deep high-galactic latitude sample, both selected at 60 microns.

Rush, Brian↗

Facility Concepts for Mars Returned Sample Handling

Samples returned from Mars must be held in quarantine until their biological safety has been determined. A significant challenge, unique to NASA's needs, is how to contain the samples (to protect the blaspheme) while simultaneously protecting their pristine nature. This paper presents a comparative analysis of several quarantine facility concepts for handling and analyzing these samples. The considerations in this design analysis include: modes of manipulation; capability for destructive as well as non-destructive testing; avoidance of cross-contamination; linear versus recursive processing; and sample storage and retrieval within a closed system. The ability to rigorously contain biologically hazardous materials has been amply demonstrated by facilities that meet the specifications of the Center for Disease Control Biosafety Level 4. The newly defined Planetary Protection Level Alpha must provide comparable containment while assuring that the samples remain pristine; the latter requirement is based on the need to avoid compromising science analyses by instrumentation of the highest possible sensitivity (among other things this will assure that there is no false positive detection of organisms or organic molecules - a situation that would delay or prevent the release of the samples from quarantine). Protection of the samples against contamination by terrestrial organisms and organic molecules makes a considerable impact upon the sample handling facility. The use of glove boxes appears to be impractical because of their tendency to leak and to surges. As a result, a returned sample quarantine facility must consider the use of automation and remote manipulation to carry out the various functions of sample handling and transfer within the system. The problem of maintaining sensitive and bulky instrumentation under the constraints of simultaneous sample containment and contamination protection also places demands on the architectural configuration of the facility that houses it.

Cohen, Marc M.↗

South Pole-Aitken Sample Return Mission: Collecting Mare Basalts from the Far Side of the Moon

We consider the probability that a sample mission to a site within the South Pole-Aitken Basin (SPA) would return basaltic material. A sample mission to the SPA would be the first opportunity to sample basalts from the far side of the Moon. The near side basalts are more abundant in terms of volume and area than their far-side counterparts (16:1), and the basalt deposits within SPA represent approx. 28% of the total basalt surface area on the far side. Sampling far-side basalts is of particular importance because as partial melts of the mantle, they could have derived from a mantle that is mineralogically and chemically different than determined for the nearside, as would be expected if the magma ocean solidified earlier on the far side. For example, evidence to support the existence of high-Th basalts like those that appear to be common on the nearside in the Procellarum KREEP Terrane has been found. Although SPA is the deepest basin on the Moon, it is not extensively filled with mare basalt, as might be expected if similar amounts of partial melting occurred in the mantle below SPA as for basins on the near side. These observations may mean that mantle beneath the far-side crust is lower in Th and other heat producing elements than the nearside. One proposed location for a sample-return landing site is 60 S, 160 W. This site was suggested to maximize the science return with respect to sampling crustal material and SPA impact melt, however, basaltic samples would undoubtedly occur there. On the basis of Apollo samples, we should expect that basaltic materials would be found in the vicinity of any landing site within SPA, even if located away from mare deposits. For example, the Apollo 16 mission landed in an ancient highlands region 250-300 km away from the nearest mare-highlands boundary yet it still contains a small component of basaltic samples (20 lithic fragments ranging is size from <1 to .01 cm). A soil sample from the floor of SPA will likely contain an assortment of basaltic fragments from surrounding regions. In terms both of selecting the best landing sites and understanding the geologic context for returned samples, it is important to understand the compositional distribution of basalts within SPA basin.

Gillis, J. J.↗

Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13

The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12- months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions. The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11. The number and sensitivity of the chemical analyses performed on this sample were limited due to low sample volume. Shuttle flights STS-121 (ULF1.1) and STS-115 (12A) docked with the ISS in July and September of 2006, respectively. These flights returned to Earth with eight chemical archive potable water samples that were collected with U.S. hardware during Expedition 13. The average collected volume increased for these samples, allowing full chemical characterization to be performed. This paper presents a discussion of the results from chemical analyses performed on Expeditions 12 and 13 archive potable water samples. In addition to the results from the U.S. samples analyzed, results from pre-flight samples of Russian potable water delivered to the ISS on Progress vehicles and in-flight samples collected with Russian hardware during Expeditions 12 and 13 and analyzed at JSC are also discussed.

Straub, John E. II↗

Sampling Biases in MODIS and SeaWiFS Ocean Chlorophyll Data

Although modem ocean color sensors, such as MODIS and SeaWiFS are often considered global missions, in reality it takes many days, even months, to sample the ocean surface enough to provide complete global coverage. The irregular temporal sampling of ocean color sensors can produce biases in monthly and annual mean chlorophyll estimates. We quantified the biases due to sampling using data assimilation to create a "truth field", which we then sub-sampled using the observational patterns of MODIS and SeaWiFS. Monthly and annual mean chlorophyll estimates from these sub-sampled, incomplete daily fields were constructed and compared to monthly and annual means from the complete daily fields of the assimilation model, at a spatial resolution of 1.25deg longitude by 0.67deg latitude. The results showed that global annual mean biases were positive, reaching nearly 8% (MODIS) and >5% (SeaWiFS). For perspective the maximum interannual variability in the SeaWiFS chlorophyll record was about 3%. Annual mean sampling biases were low (<3%) in the midlatitudes (between -40deg and 40deg). Low interannual variability in the global annual mean sampling biases suggested that global scale trend analyses were valid. High latitude biases were much higher than the global annual means, up to 20% as a basin annual mean, and over 80% in some months. This was the result of the high solar zenith angle exclusion in the processing algorithms. Only data where the solar angle is <75deg are permitted, in contrast to the assimilation which samples regularly over the entire area and month. High solar zenith angles do not facilitate phytoplankton photosynthesis and consequently low chlorophyll concentrations occurring here are missed by the data sets. Ocean color sensors selectively sample in locations and times of favorable phytoplankton growth, producing overestimates of chlorophyll. The biases derived from lack of sampling in the high latitudes varied monthly, leading to artifacts in the apparent seasonal cycle from ocean color sensors. A false secondary peak in chlorophyll occurred in May-August, which resulted from lack of sampling in the Antarctic.

Gregg, Watson W.↗

Collecting Ground Samples for Balloon-Borne Instruments

A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

Jones, Jack↗

Lunar and Meteorite Sample Education Disk Program - Space Rocks for Classrooms, Museums, Science Centers, and Libraries

NASA is eager for students and the public to experience lunar Apollo samples and meteorites first hand. Lunar rocks and soil, embedded in Lucite disks, are available for educators to use in their classrooms, museums, science centers, and public libraries for education activities and display. The sample education disks are valuable tools for engaging students in the exploration of the Solar System. Scientific research conducted on the Apollo rocks reveals the early history of our Earth-Moon system and meteorites reveal much of the history of the early solar system. The rocks help educators make the connections to this ancient history of our planet and solar system and the basic processes accretion, differentiation, impact and volcanism. With these samples, educators in museums, science centers, libraries, and classrooms can help students and the public understand the key questions pursued by many NASA planetary missions. The Office of the Curator at Johnson Space Center is in the process of reorganizing and renewing the Lunar and Meteorite Sample Education Disk Program to increase reach, security and accountability. The new program expands the reach of these exciting extraterrestrial rocks through increased access to training and educator borrowing. One of the expanded opportunities is that trained certified educators from science centers, museums, and libraries may now borrow the extraterrestrial rock samples. Previously the loan program was only open to classroom educators so the expansion will increase the public access to the samples and allow educators to make the critical connections to the exciting exploration missions taking place in our solar system. Each Lunar Disk contains three lunar rocks and three regolith soils embedded in Lucite. The anorthosite sample is a part of the magma ocean formed on the surface of Moon in the early melting period, the basalt is part of the extensive lunar mare lava flows, and the breccias sample is an important example of the violent impact history of the Moon. The disks also include two regolith soils and orange glass from a pyroclastic deposit. Each Meteorite Disk contains two ordinary chondrites, one carbonaceous chondrite, one iron, one stony iron, and one achondrite. These samples will help educators share the early history of the solar system with students and the public. Educators may borrow either lunar or meteorite disks and the accompanying education materials through the Johnson Space Center Curatorial Office. In trainings provided by the NASA Aerospace Education Services Program specialists, educators certified to borrow the disk learn about education resources, the proper use of the samples, and the special security for care and shipping of the disks. The Lunar and Meteorite Sample Education Disk Program will take NASA exploration to more people. Getting Space Rocks out to the public and inspiring the public about new space exploration is the focus of the NASA disk loan program.

Allen, Jaclyn↗

Sample Caching Subsystem

A paper describes the Sample Caching Subsystem (SCS), a method for storing planetary core and soil samples in a container that seals the samples away from the environment to protect the integrity of the samples and any organics they might contain. This process places samples in individual sleeves that are sealed within a container for use by either the current mission or by following missions. A sample container is stored with its sleeves partially inserted. When a sample is ready to be contained, a transfer arm rotates over and grasps a sleeve, pulls it out of the container from below, rotates over and inserts the sleeve into a funnel where it is passively locked into place and then released from the arm. An external sampling tool deposits the sample into the sleeve, which is aligned with the tool via passive compliance of the funnel. After the sampling tool leaves the funnel, the arm retrieves the sleeve and inserts it all the way into the sample container. This action engages the seal. Full containers can be left behind for pick-up by subsequent science missions, and container dimensions are compatible for placement in a Mars Ascent Vehicle for later return to Earth.

Backes, Paul G.↗

Pieces of Other Worlds - Extraterrestrial Samples for Education and Public Outreach

During the Year of the Solar System spacecraft from NASA and our international partners will encounter two comets; orbit the asteroid Vesta, continue to explore Mars with rovers, and launch robotic explorers to the Moon and Mars. We have pieces of all these worlds in our laboratories, and their continued study provides incredibly valuable "ground truth" to complement space exploration missions. Extensive information about these unique materials, as well as actual lunar samples and meteorites, are available for display and education. The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. At the current time JSC curates six types of extraterrestrial samples: (1) Moon rocks and soils collected by the Apollo astronauts (2) Meteorites collected on US expeditions to Antarctica (including rocks from the Moon, Mars, and many asteroids including Vesta) (3) "Cosmic dust" (asteroid and comet particles) collected by high-altitude aircraft (4) Solar wind atoms collected by the Genesis spacecraft (5) Comet particles collected by the Stardust spacecraft (6) Interstellar dust particles collected by the Stardust spacecraft These rocks, soils, dust particles, and atoms continue to be studied intensively by scientists around the world. Descriptions of the samples, research results, thousands of photographs, and information on how to request research samples are on the JSC Curation website: http://curator.jsc.nasa.gov/ NASA provides a limited number of Moon rock samples for either short-term or long-term displays at museums, planetariums, expositions, and professional events that are open to the public. The JSC Public Affairs Office handles requests for such display samples. Requestors should apply in writing to Mr. Louis Parker, JSC Exhibits Manager. Mr. Parker will advise successful applicants regarding provisions for receipt, display, and return of the samples. All loans will be preceded by a signed loan agreement executed between NASA and the requestor's organization. Email address: louis.a.parker@nasa.gov Sets of twelve thin sections of Apollo lunar samples and sets of twelve thin sections of meteorites are available for short-term loan from JSC Curation. The thin sections are designed for use in college and university courses where petrographic microscopes are available for viewing. Requestors should contact the Ms. Mary Luckey, Education Sample Curator. Email address: mary.k.luckey@nasa.gov

Allen, Carlton C.↗

Multivariate Methods for Prediction of Geologic Sample Composition with Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) uses pulses of laser light to ablate a material from the surface of a sample and produce an expanding plasma. The optical emission from the plasma produces a spectrum which can be used to classify target materials and estimate their composition. The ChemCam instrument on the Mars Science Laboratory (MSL) mission will use LIBS to rapidly analyze targets remotely, allowing more resource- and time-intensive in-situ analyses to be reserved for targets of particular interest. ChemCam will also be used to analyze samples that are not reachable by the rover's in-situ instruments. Due to these tactical and scientific roles, it is important that ChemCam-derived sample compositions are as accurate as possible. We have compared the results of partial least squares (PLS), multilayer perceptron (MLP) artificial neural networks (ANNs), and cascade correlation (CC) ANNs to determine which technique yields better estimates of quantitative element abundances in rock and mineral samples. The number of hidden nodes in the MLP ANNs was optimized using a genetic algorithm. The influence of two data preprocessing techniques were also investigated: genetic algorithm feature selection and averaging the spectra for each training sample prior to training the PLS and ANN algorithms. We used a ChemCam-like laboratory stand-off LIBS system to collect spectra of 30 pressed powder geostandards and a diverse suite of 196 geologic slab samples of known bulk composition. We tested the performance of PLS and ANNs on a subset of these samples, choosing to focus on silicate rocks and minerals with a loss on ignition of less than 2 percent. This resulted in a set of 22 pressed powder geostandards and 80 geologic samples. Four of the geostandards were used as a validation set and 18 were used as the training set for the algorithms. We found that PLS typically resulted in the lowest average absolute error in its predictions, but that the optimized MLP ANN and the CC ANN often gave results comparable to PLS. Averaging the spectra for each training sample and/or using feature selection to choose a small subset of wavelengths to use for predictions gave mixed results, with degraded performance in some cases and similar or slightly improved performance in other cases. However, training time was significantly reduced for both PLS and ANN methods by implementing feature selection, making this a potentially appealing method for initial, rapid-turn-around analyses necessary for Chemcam's tactical role on MSL. Choice of training samples has a strong influence on the accuracy of predictions. We are currently investigating the use of clustering algorithms (e.g. k-means, neural gas, etc.) to identify training sets that are spectrally similar to the unknown samples that are being predicted, and therefore result in improved predictions

Morris, Richard↗