Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE FACILITIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An optimization model for energy generation and distribution in a dynamic facility

An analytical model is described using linear programming for the optimum generation and distribution of energy demands among competing energy resources and different economic criteria. The model, which will be used as a general engineering tool in the analysis of the Deep Space Network ground facility, considers several essential decisions for better design and operation. The decisions sought for the particular energy application include: the optimum time to build an assembly of elements, inclusion of a storage medium of some type, and the size or capacity of the elements that will minimize the total life-cycle cost over a given number of years. The model, which is structured in multiple time divisions, employ the decomposition principle for large-size matrices, the branch-and-bound method in mixed-integer programming, and the revised simplex technique for efficient and economic computer use.

Lansing, F. L.↗

The SIR-C ground data system: Digital processor, data products, information flow

The SIR-C (Shuttle Imaging Radar) instrument will collect both C-Band and L-Band data with each frequency band consisting of direct (HH or VV) and cross-polarized (HV or VH) data. Considering all possible combinations as many as eight different data channels will be available for any given target area. This data will be digitized and formatted on-board for direct downlink via the Tracking and Data Relay Satellite System (TDRSS), or it will be buffered through on-board high density digital recorders for storage or transmission when TDRSS is available. The data is received by the TDRSS ground station at White Sands and is nominally relayed via DOMSAT to the high data rate recording facility at GSFC. The tapes are then shipped to JPL for processing into imagery and eventual distribution to the SIR-C investigators.

Curlander, John C.↗

Tank Pressure Control Experiment on the Space Shuttle

The tank pressure control experiment is a demonstration of NASA intent to develop new technology for low-gravity management of the cryogenic fluids that will be required for future space systems. The experiment will use freon as the test fluid to measure the effects of jet-induced fluid mixing on storage tank pressure and will produce data on low-gravity mixing processes critical to the design of on-orbit cryogenic storage and resupply systems. Basic data on fluid motion and thermodynamics in low gravity is limited, but such data is critical to the development of space transfer vehicles and spacecraft resupply facilities. An in-space experiment is needed to obtain reliable data on fluid mixing and pressure control because none of the available microgravity test facilities provide a low enough gravity level for a sufficient duration to duplicate in-space flow patterns and thermal processes. Normal gravity tests do not represent the fluid behavior properly; drop-tower tests are limited in length of time available; aircraft low-gravity tests cannot provide the steady near-zero gravity level and long duration needed to study the subtle processes expected in space.

Source record↗

Photographic films for the Multi-Spectral Solar Telescope Array

The rocketborne Multi-Spectral Solar Telescope Array (MSSTA) uses an array of Ritchey-Chretien, Cassegrain, and Herschelian telescopes to produce ultrahigh-resolution full-disk images of the sun within the soft X-ray, EUV, and FUV ranges. Such imaging of the solar disk and corona out to several solar radii placed great demands on the MSSTA's data storage capabilities; in addition, its photographic films required very low outgassing rates. Results are presented from calibration tests conducted on the MSSTA's emulsions, based on measurements at NIST's synchrotron facility.

Hoover, Richard B.↗

Recent Productivity Improvements to the National Transonic Facility

Productivity gains have recently been made at the National Transonic Facility wind tunnel at NASA Langley Research Center. A team was assigned to assess and set productivity goals to achieve the desired operating cost and output of the facility. Simulations have been developed to show the sensitivity of selected process productivity improvements in critical areas to reduce overall test cycle times. The improvements consist of an expanded liquid nitrogen storage system, a new fan drive, a new tunnel vent stack heater, replacement of programmable logic controllers, an increased data communications speed, automated test sequencing, and a faster model changeout system. Where possible, quantifiable results of these improvements are presented. Results show that in most cases, improvements meet the productivity gains predicted by the simulations.

Popernack, Thomas G., Jr.↗

800 Hours of Operational Experience from a 2 kW(sub e) Solar Dynamic System

From December 1994 to September 1998, testing with a 2 kW(sub e) Solar Dynamic power system resulted in 33 individual tests, 886 hours of solar heating, and 783 hours of power generation. Power generation ranged from 400 watts to over 2 kW(sub e), and SD system efficiencies have been measured up to 17 per cent, during simulated low-Earth orbit operation. Further, the turbo-alternator-compressors successfully completed 100 start/stops on foil bearings. Operation was conducted in a large thermal/vacuum facility with a simulated Sun at the NASA Lewis Research Center. The Solar Dynamic system featured a closed Brayton conversion unit integrated with a solar heat receiver, which included thermal energy storage for continuous power output through a typical low-Earth orbit. Two power conversion units and three alternator configurations were used during testing. This paper will review the test program, provide operational and performance data, and review a number of technology issues.

Shaltens, Richard K.↗

Low Temperature Double-layer Capacitors with Improved Energy Density: An Overview of Recent Development Efforts

Electrochemical double-layer capacitors are finding increased use in a wide range of energy storage applications, particularly where high pulse power capabilities are required. Double-layer capacitors store charge at a liquid/solid interface, making them ideal for low temperature power applications, due to the facile kinetic processes associated with the rearrangement of the electrochemical double-layer at these temperatures. Potential low temperature applications include hybrid and electric vehicles, operations in polar regions, high altitude aircraft and aerospace avionics, and distributed environmental and structural health monitoring. State-of-the-art capacitors can typically operate to -40 C, with a subsequent degradation in power performance below room temperature. However, recent efforts focused on advanced electrolyte and electrode systems can enable operation to temperatures as low as -70 C, with capacities similar to room temperature values accompanied by reasonably low equivalent series resistances. This presentation will provide an overview of recent development efforts to extend and improve the wide temperature performance of these devices.

Supercapacitors↗

Western Tennessee Water Resources: Leveraging High Resolution Remotely Sensed Data to Assess Water Availability and Vulnerability in the Memphis Aquifer Area in West Tennessee

The Memphis Aquifer (MA) is located in the Mississippi Embayment that extends 250,000 square kilometers across eight states. Fayette and Haywood counties in West Tennessee are situated within the recharge zone of the MA and include the forthcoming Ford “mega campus” named Blue Oval City (BOC), which will consist of a vehicle-production facility and battery assembly division. Increased water demand and land cover change resulting from urban development, such as BOC in the MA’s narrow recharge zone, threaten the aquifer’s groundwater storage and recharge rate. Groundwater recharge factors that influence the narrow recharge zone of the MA include precipitation, evapotranspiration, runoff, and land cover type. In partnership with Protect Our Aquifer (POA) and the Center for Applied Earth Science and Engineering Research (CAESAR) at the University of Memphis, the team used data from the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS), Integrated Multi-Satellite Retrievals for Global Precipitation Measurement (GPM IMERG), and Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS). The team also used ancillary data from the National Land Cover Database (NLCD) and the North American Land Data Assimilation System (NLDAS) Noah Land Surface Model. These results identified “thriving” recharge locations, which are areas most conducive to aquifer recharge in Fayette County. The partners may use the results to prioritize specific areas in need of protection before they become susceptible to the effects of urbanization and industrialization.

precipitation↗

Experiences From NASA/Langley's DMSS Project

There is a trend in institutions with high performance computing and data management requirements to explore mass storage systems with peripherals directly attached to a high speed network. The Distributed Mass Storage System (DMSS) Project at the NASA Langley Research Center (LaRC) has placed such a system into production use. This paper will present the experiences, both good and bad, we have had with this system since putting it into production usage. The system is comprised of: 1) National Storage Laboratory (NSL)/UniTree 2.1, 2) IBM 9570 HIPPI attached disk arrays (both RAID 3 and RAID 5), 3) IBM RS6000 server, 4) HIPPI/IPI3 third party transfers between the disk array systems and the supercomputer clients, a CRAY Y-MP and a CRAY 2, 5) a "warm spare" file server, 6) transition software to convert from CRAY's Data Migration Facility (DMF) based system to DMSS, 7) an NSC PS32 HIPPI switch, and 8) a STK 4490 robotic library accessed from the IBM RS6000 block mux interface. This paper will cover: the performance of the DMSS in the following areas: file transfer rates, migration and recall, and file manipulation (listing, deleting, etc.); the appropriateness of a workstation class of file server for NSL/UniTree with LaRC's present storage requirements in mind the role of the third party transfers between the supercomputers and the DMSS disk array systems in DMSS; a detailed comparison (both in performance and functionality) between the DMF and DMSS systems LaRC's enhancements to the NSL/UniTree system administration environment the mechanism for DMSS to provide file server redundancy the statistics on the availability of DMSS the design and experiences with the locally developed transparent transition software which allowed us to make over 1.5 million DMF files available to NSL/UniTree with minimal system outage

Source record↗

Encode/Decode facility for FORTRAN 4

An ENCODE and DECODE facility, a subroutine added to a FORTRAN 4 library, allows alphanumeric data to be transfered to or from an area in memory rather than to or from external input/output devices. A buffer storage array allows the operations on the data prior to writing.

Cohn, C. E.↗

ERDA/Lewis research center photovoltaic systems test facility

A national photovoltaic power systems test facility (of initial 10-kW peak power rating) is described. It consists of a solar array to generate electrical power, test-hardware for several alternate methods of power conversion, electrical energy storage systems, and an instrumentation and data acquisition system.

Forestieri, A. F.↗

Microprocessor-to-system/370 interface

The design and operation of a microprocessor interface unit which allows use of a computer terminal for communication at 110 or 300 baud both with a central host computer and with the microprocessor monitor are documented. Additionally, the interface permits the host computer to load the microprocessor memory directly with object code, avoiding the use of intermediate data storage such as paper tape. The central computer, containing an assembler language processor for the target microcomputer, can be used from the terminal with all the flexibility offered by the virtual machine facility, producing object code for the micro plus program listings and supporting outputs. The object code can then be loaded directly to the micro and the same terminal device used to run the micro program, communicating with the micro's monitor routine.

Lilley, R. W.↗

Solar heating and hot water system installed at Listerhill, Alabama

The Solar system was installed into a new building and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

Source record↗

Characteristics of RF Lightning Emission at 2 Ghz and 250 Mhz

Radio frequency emissions in the S-band and VHF range from lightning discharges are recorded by a facility developed at MSFC as part of a feasibility study of a satellite-based lightning mapping system. The recording facility receives RF emissions in both vertical and horizontal polarization and stores the data on magnetic tape. Output from any one antenna may also be selected for high speed digitization and disk storage. Improvement in both hardware and software have enhanced significantly the accuracy of data characterization and the speed of data collection. Emission records at VHF have higher signal strength than the S-band as expected. The records of cloud-to-ground discharges obtained so far give a 7-33 V/M peak equivalent signal strength (1 KHz at 10 kilometer) in the S-band range. The CG discharge structure is recognizable in most of the data collected. Considerable RF activity is present throughout the VHF records. The S-band data shows signals associated with limited portions of discharge history. The records obtained are from lightning activities within a 10 mile range.

Jalali, F.↗

Life prediction and constitutive behavior: Overview

The evolution of programs to investigate high temperature consititutive behavior and develop cyclic life prediction methods is reviewed. Contracts granted for developing and verifying workable engineering methods for the calculation, in advance of service, of the local stress-strain response at the critical life governing location in typical hot section components as well as the resultant cyclic crack initiation and crack growth lifetimes are listed. The Langley fatigue facility is being upgraded to include: (1) a servocontrolled testing machine for high temperature crack growth; (2) three servocontrolled tension/torsion machines for biaxial studies; (3) a HOST/satellite computer for data acquisition, processing, storage, and retrieval; and (4) HCV/LCF machines for cumulative damage studies.

Halford, G. R.↗

Impedances of Li/SO2 cells retrieved from the Long Duration Exposure Facility (LDEF satellite) and comparison with cells stored terrestrially

Impedances were measured on several Li/SO2 cells retrieved from the Long Duration Exposure Facility (LDEF) satellite. These cells were used to power instruments and recorders and had all been partially or fully discharged. Impedances were also measured on several cells that were stored in cold storage since manufacture. Unfortunately, none of the cells stored terrestrially had undergone any discharge, whereas all of the cells on the satellite were at least partially discharged early in the mission and then remained on orbit for about 5 years further. It has been observed by others that storage of an Li/SO2 cell after partial discharge, increases the resistance and thickness of the passive film on the Li electrode, as indicated by an increase in the time for recovery of voltage when a load is applied (voltage lag), or in some cases by an inability of a cell to sustain a normal current after such storage. Since the cells stored terrestrially were not discharged in the same manner as the LDEF cells, a direct comparison cannot be made. Thus, the effects of the space environment cannot be separated from the effects of storage after partial discharge. It is believed that the increases in impedance in the LDEF cells are largely due to the storage upon partial discharge rather than the effects of the space environment.

Reid, Margaret A.↗

Absolute Calibration of the AXAF Telescope Effective Area

The prelaunch calibration of AXAF encompasses many aspects of the telescope. In principle, all that is needed is the complete point response function. This is, however, a function of energy, off-axis angle of the source, and operating mode of the facility. No single measurement would yield the entire result. Also, any calibration made prior to launch will be affected by changes in conditions after launch, such as the change from one g to zero g. The reflectivity of the mirror and perhaps even the detectors can change as well, for example by addition or removal of small amounts of material deposited on their surfaces. In this paper, we give a broad view of the issues in performing such a calibration, and discuss how they are being addressed in prelaunch preparation of AXAF. As our title indicates, we concentrate here on the total throughput of the observatory. This can be thought of as the integral of the point response function, i.e. the encircled energy, out ot the largest practical solid angle for an observation. Since there is no standard x-ray source in the sky whose flux is known to the -1% accuracy we are trying to achieve, we must do this calibration on the ground. we also must provide a means for monitoring any possible changes in this calibration from pre-launch until on-orbit operation can transfer the calibration to a celestial x-ray source whose emission is stable. In this paper, we analyze the elements of the absolute throughput calibration, which we call Effective Area. We review the requirements for calibrations of components or subsystems of the AXAF facility, including mirror, detectors, and gratings. We show how it is necessary to calibrate this ground-based detection system at standard man-made x-ray sources, such as electron storage rings. We present the status of all these calibrations, with indications of the measurements remaining to be done, even though the measurements on the AXAF flight optics and detectors will have been completed by the time this paper is presented. We evaluate progress toward the goal of making 1% measurements of the absolute x-ray flux from astrophysical sources, so that comparisons can be made with their emission at other wavelengths, in support of observations such as the Sunyaev-Zeldovitch effect, which can give absolute distance measurements independent of the traditional distance measuring techniques in astronomy.

Kellogg, E.↗

The Development of NDE Techniques for Large Cryogenic Storage Tanks

Objectives of this project are: (1) Develop and demonstrate NDE techniques to evaluate the condition of large cryogenic Dewars (typically 50,000 to 900,000 gaL). (2) These tanks are used across NASA for launch pads, engine test stands, cryogenic wind tunnels and other facilities: they represent a major investment. (3) Issues addressed: (1) Insulation integrity of existing Dewars (powdered insulation under vacuum or sometimes ambient pressure (LO2), (2) Post fabrication insulation verification without full chill-down to avoid thermal cycling the tank (fatigue limitation of piping and compaction of Perlite).

Youngquist, Robert↗