Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOLAR RESOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Optimized O'Neill/Glaser Model for Human Population of Space and its Impact on Survival Probabilities

Two contemporary issues foretell a shift from our historical Earth based industrial economy and habitation to a solar system based society. The first is the limits to Earth's carrying capacity, that is the maximum number of people that the Earth can support before a catastrophic impact to the health of the planet and human species occurs. The simple example of carrying capacity is that of a bacterial colony in a Petri dish with a limited amount of nutrient. The colony experiences exponential population growth until the carrying capacity is reached after which catastrophic depopulation often results. Estimates of the Earth s carrying capacity vary between 14 and 40 billion people. Although at current population growth rates we may have over a century before we reach Earth s carrying limit our influence on climate and resources on the planetary scale is becoming scientifically established. The second issue is the exponential growth of knowledge and technological power. The exponential growth of technology interacts with the exponential growth of population in a manner that is unique to a highly intelligent species. Thus, the predicted consequences (world famines etc.) of the limits to growth have been largely avoided due to technological advances. However, at the mid twentieth century a critical coincidence occurred in these two trends humanity obtained the technological ability to extinguish life on the planetary scale (by nuclear, chemical, biological means) and attained the ability to expand human life beyond Earth. This paper examines an optimized O Neill/Glaser model (O Neill 1975; Curreri 2007; Detweiler and Curreri 2008) for the economic human population of space. Critical to this model is the utilization of extraterrestrial resources, solar power and spaced based labor. A simple statistical analysis is then performed which predicts the robustness of a single planet based technological society versus that of multiple world (independent habitats) society.

Curreri, Peter A.↗

Optimized O'Neill/Glaser Model for Human Population of Space and its Impact on Survival Probabilities

Two contemporary issues foretell a shift from our historical Earth based industrial economy and habitation to a solar system based society. The first is the limits to Earth s carrying capacity, that is the maximum number of people that the Earth can support before a catastrophic impact to the health of the planet and human species occurs. The simple example of carrying capacity is that of a bacterial colony in a Petri dish with a limited amount of nutrient. The colony experiences exponential population growth until the carrying capacity is reached after which catastrophic depopulation often results. Estimates of the Earth s carrying capacity vary between 14 and 40 billion people. Although at current population growth rates we may have over a century before we reach Earth s carrying limit our influence on climate and resources on the planetary scale is becoming scientifically established. The second issue is the exponential growth of knowledge and technological power. The exponential growth of technology interacts with the exponential growth of population in a manner that is unique to a highly intelligent species. Thus, the predicted consequences (world famines etc.) of the limits to growth have been largely avoided due to technological advances. However, at the mid twentieth century a critical coincidence occurred in these two trends humanity obtained the technological ability to extinguish life on the planetary scale (by nuclear, chemical, biological means) and attained the ability to expand human life beyond Earth. This paper examines an optimized O Neill/Glaser model (O Neill 1975; Curreri 2007; Detweiler and Curreri 2008) for the economic human population of space. Critical to this model is the utilization of extraterrestrial resources, solar power and spaced based labor. A simple statistical analysis is then performed which predicts the robustness of a single planet based technological society versus that of multiple world (independent habitats) society.

Curreri, Peter A.↗

Optimized O'Neill/Glaser Model for Human Population of Space and its Impact on Survival Probabilities

Two contemporary issues foretell a shift from our historical Earth based industrial economy and habitation to a solar system based society. The first is the limits to Earth s carrying capacity, that is the maximum number of people that the Earth can support before a catastrophic impact to the health of the planet and human species occurs. The simple example of carrying capacity is that of a bacterial colony in a Petri dish with a limited amount of nutrient. The colony experiences exponential population growth until the carrying capacity is reached after which catastrophic depopulation often results. Estimates of the Earth s carrying capacity vary between 14 and 40 billion people. Although at current population growth rates we may have over a century before we reach Earth s carrying limit our influence on climate and resources on the planetary scale is becoming scientifically established. The second issue is the exponential growth of knowledge and technological power. The exponential growth of technology interacts with the exponential growth of population in a manner that is unique to a highly intelligent species. Thus, the predicted consequences (world famines etc.) of the limits to growth have been largely avoided due to technological advances. However, at the mid twentieth century a critical coincidence occurred in these two trends humanity obtained the technological ability to extinguish life on the planetary scale (by nuclear, chemical, biological means) and attained the ability to expand human life beyond Earth. This paper examines an optimized O'Neill/Glaser model (O Neill 1975; Curreri 2007; Detweiler and Curreri 2008) for the economic human population of space. Critical to this model is the utilization of extraterrestrial resources, solar power and spaced based labor. A simple statistical analysis is then performed which predicts the robustness of a single planet based technological society versus that of multiple world (independent habitats) society.

Curreri, Peter A.↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

Surface albedo and reflectance: Review of definitions, angular and spectral effects, and intercomparison of major data sources in support of advanced solar irradiance modeling over the Americas

This study defines albedo and reflectance in the context of solar applications. It examines the main sources of surface albedo data that can be used to help solar irradiance modeling efforts, such as undertaken by the National Renewable Energy Laboratory (NREL) over the Americas, for instance, per the National Solar Radiation Database (NSRDB). The MODIS-based albedo database, as used as input to derive historical time series of solar irradiance in the current version of the NSRDB, is compared to other sources of global gridded data over the Americas in general and some specific areas in particular. The particular role of snow cover is analyzed. It is found that, in the current MODIS-based NSRDB implementation, snow-impacted areas have been assigned a too high albedo in general because of the lack of consideration for the antagonistic effect of surface roughness, among other factors. Other albedo databases, such as CMSAF, MINES-ParisTech or the ERA5 reanalysis, do not display such high albedos at latitudes above ~40 degrees N. The gap-free and snow-free MODIS MCD43GF product is found affected by a long-term downward trend over some areas and out-of-phase seasonal effects over other areas, in comparison with MERRA-2 reanalysis data in particular. Comparisons with actual albedo measurements at the arid Desert Rock site in Nevada also show that albedo data derived from land surface models are affected by systematic bias. Five albedo databases are intercompared for the area around Ivanpah Playa, California, which has great importance in both remote sensing and solar applications. Various aspects of the proper usage of albedo data in solar radiation modeling are discussed, regarding calculations of both the backscattering process and reflections on a tilted surface: spatial resolution, temporal resolution, angular effects, and spectral effects. An important distinction is made between the use of albedo data at ~4 km resolution for backscattering calculations and at ~10 m resolution for transposition calculations to tilted planes, which might additionally require spectral information for monofacial or bifacial PV applications. It is shown that the tilted calculations usually performed in solar resource assessments are far from realistic in the case of most large-scale PV applications, for which a more suitable methodological approach is described. For such needs, the limitations of the current sources of high-resolution reflectance data are discussed. The impact of surface albedo estimation errors on the estimation of backscattered irradiance over snowy areas is evaluated. It is found non-negligible, and even large under cloudy conditions.

14 SOLAR ENERGY↗

Utility-Scale Solar Data Update (2020 Edition) [Slides]

Berkeley Lab’s 2020 update of utility-scale solar data and trends provides an overview of key trends in the U.S. market, with a focus on 2019. Highlights of this year’s update include: More than 4.5 GWAC of utility-scale solar (i.e., ground-mounted solar projects larger than 5 MWAC) achieved commercial operations in 2019, bringing cumulative capacity to 29 GWAC. Projects are spread across all 10 regions that we track, though more heavily concentrated in the sunniest regions. The median installed cost of projects that came online in 2019 fell to $\$$1.4/WAC ($\$$1.2/WDC), down 20% from 2018 and down by more than 70% from 2010. 77% of projects and 88% of capacity added in 2019 used single-axis tracking. Average capacity factors range from 17% in the least-sunny regions to 30% where it is sunniest. Single-axis tracking adds roughly five percentage points to capacity factor in the regions with the strongest solar resource. Nationwide average levelized power purchase agreement (PPA) prices fell to $\$$24/MWh in 2019, down 17% from 2018 and more than 80% since 2010. Thirty-nine projects (totaling 4.2 GWAC) in our PPA price sample include battery storage (totaling 2.3 GWAC and 9.5 GWh). In the “lower 48” states, a number of these recent PV+battery PPAs have been inked in the mid-$\$$20/MWh range (levelized in 2019 dollars).Not including the 30% investment tax credit (ITC), the median levelized cost of energy (LCOE) from utility-scale PV has declined by 85% since 2010, to $\$$40/MWh in 2019. When the 30% ITC is included within the LCOE calculation, the median LCOE closely tracks the median PPA price over time. In higher-penetration markets like CAISO, the value of solar has been declining, but falling PPA prices have largely kept pace, preserving solar's net value. At the end of 2019, there were nearly 370 GW of solar in interconnection queues from all 7 ISOs and 30 additional utilities across the country. Nearly a third of this proposed solar capacity is paired with battery storage.

14 SOLAR ENERGY↗

Analysis of High-Penetration Levels of Photovoltaics into the Distribution Grid on Oahu, Hawaii: Detailed Analysis of HECO Feeder WF1

Renewable generation is growing at a rapid rate due to the incentives available and the aggressive renewable portfolio standard (RPS) targets implemented by state governments. Distributed generation in particular is seeing the fastest growth among renewable energy projects, and is directly related to the incentives. Hawaii has the highest electricity costs in the country due to the high percentage of oil burning steam generation, and therefore has some of the highest penetration of distributed PV in the nation. The High Penetration PV (HiP-PV) project on Oahu aims to understand the effects of high penetration PV on the distribution level, to identify penetration levels creating disturbances on the circuit, and to offer mitigating solutions based on model results. Power flow models are validated using data collected from solar resources and load monitors deployed throughout the circuit. Existing interconnection methods and standards such as IEEE 1547, Hawaii Rule 14H and California Rule 21 are evaluated in these emerging high penetration scenarios. A key finding is a shift in the level of detail to be considered and moving away from steady-state peak time analysis towards dynamic and time varying simulations. Each level of normal interconnection study is evaluated and enhanced to a new level of detail, allowing full understanding of each issue.

14 SOLAR ENERGY↗

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar San Diego: The Impact of Binomial Rate Structures on Real PV-Systems

There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rates structures is presented. The data revealed that actual demand and energy use benefits of bionomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007. Future work will include combining demand and electricity charges and increasing the breadth of rate structures tested, including the impacts of non-coincident demand charges.

14 SOLAR ENERGY↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

Opportunities for Solar Industrial Process Heat in the United States

This presentation summarizes the first national analysis of opportunities for solar technologies to provide industrial process heat (IPH) in the United States. The industrial sector is a major end-user of energy and IPH constitutes a majority of industrial fuel energy. New disaggregations of IPH demands are made at the temporal, geographic, and operational levels. Solar heat generation by seven solar thermal technologies and PV-connected electrotechnologies are modeled using county solar resources and land availability and matched to relevant IPH demands. Parabolic trough collectors (PTC), when combined with thermal energy storage (TES), not only have the largest opportunity in terms of distribution over geography and time, but also in terms of applicable IPH demands. PTC with TES represents the displacement of nearly 2,500 trillion Btus of combustion fuels, which corresponds to 137 million metric tons of CO2, or about 15% of all industrial combustion CO2 emissions. TES, along with site-level analysis, are identified as areas of further analysis.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Is $50/MWh solar for real? Falling project prices and rising capacity factors drive utility-scale PV toward economic competitiveness

Recently announced low-priced power purchase agreements (PPAs) for US utility-scale photovoltaic (PV) projects suggest $50/MWh solar might be viable under certain conditions. To explore this possibility, this paper draws on an increasing wealth of empirical data to analyze trends in three of the most important PPA price drivers: upfront installed project prices, operations, and maintenance (O&M) costs, and capacity factors. Average installed prices among a sample of utility-scale PV projects declined by more than one third (from 5.8/W AC to 3.7/WAC) from the 2007–2009 period through 2013, even as costlier systems with crystalline-silicon modules, sun tracking, and higher inverter loading ratios (ILRs) have constituted an increasing proportion of total utility-scale PV capacity (all values shown here are in 2013 dollars). Actual and projected O&M costs from a very small sample of projects appear to range from $20–$40/kW AC -year. Furthermore, the average net capacity factor is 30% for projects installed in 2012, up from 24% for projects installed in 2010, owing to better solar resources, higher ILRs, and greater use of tracking among the more recent projects. Based on these trends, a pro-forma financial model suggests that $50/MWh utility-scale PV is achievable using a combination of aggressive-but-achievable technical and financial input parameters (including receipt of the 30% federal investment tax credit). Although the US utility-scale PV market is still young, the rapid progress in the key metrics documented in this paper has made PV a viable competitor against other utility-scale renewable generators, and even conventional peaking generators, in certain regions of the country.

14 SOLAR ENERGY↗

Effective deployment of photovoltaics in the Mediterranean countries: Balancing policy risk and return

Although the Mediterranean region is blessed with abundant solar resources, photovoltaic energy currently represents a very small share of power production. In Germany however, a much less sunny country, the photovoltaic (PV) industry is booming. This country has become a front runner in the adoption of PV because of effective policy incentives. Based on a cross-case study analysis of the German, Spanish and Greek PV markets, this paper investigates factors determining the effectiveness of PV policies. Our analysis shows that, above a certain level of return, risk-related factors (such as policy instability and administrative hurdles) play a more important role in influencing investment decisions than return-related factors (such as the level of a feed-in tariff). (author)

14 SOLAR ENERGY↗

Photovoltaics on Landfills in Puerto Rico

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Commonwealth of Puerto Rico for a feasibility study of m0treAlables on several brownfield sites. The EPA defines a brownfield as 'a property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant.' All of the brownfields in this study are landfill sites. Citizens of Puerto Rico, city planners, and site managers are interested in redevelopment uses for landfills in Puerto Rico, which are particularly well suited for solar photovoltaic (PV) installation. The purpose of this report is to assess the landfills with the highest potential for possible solar PV installation and estimate cost, performance, and site impacts of three different PV options: crystalline silicon (fixed-tilt), crystalline silicon (single-axis tracking), and thin film (fixed-tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. All of the landfills in Puerto Rico were screened according to these criteria in order to determine the sites with the greatest potential. Eight landfills were chosen for site visits based on the screening criteria and location. Because of time constraints and the fact that Puerto Rico is a relatively large island, the eight landfills for this visit were all located in the eastern half of the island. The findings from this report can be applied to landfills in the western half of the island. The economics of a potential PV system on landfills in Puerto Rico depend greatly on the cost of electricity. Currently, PREPA has an average electric rate of $0.119/kWh. Based on past electric rate increases in Puerto Rico and other islands in the Caribbean, this rate could increase to $0.15/kWh or higher in a relatively short amount of time. In the coming years, increasing electrical rates and increased necessity for clean power will continue to improve the feasibility of implementing solar PV systems at these sites.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FINAL REPORT: SUNSHINE STATE SOLAR GRID INITIATIVE (SUNGRIN) PHASE 1 (Critical Milestone Review Version)

This report provides details on the activities and accomplishments of Phase 1 of the Sunshine State Solar Grid Initiative (SUNGRIN) Project for the period beginning 4/28/2010 and ending 12/31/2011. SUNGRIN is a five-phase high-penetration solar PV project within the Systems Integration (SI) area of the Solar Energy Technologies (SETP) Program, under the SunShot Initiative. SUNGRIN is focused on understanding and enabling high-penetration grid-connected solar PV through simulation assisted studies of actual Florida utility high-penetration distribution circuits as well as substations and, to a limited extent, the bulk power system. Each phase builds and expands upon the efforts of the previous phase, leading to a comprehensive examination and understanding of high-penetration solar PV issues, from the solar resource to the conversion and integration technologies to the electric power system, with Florida and it’s utility partners providing the broad range of conditions and system integration scenarios necessary to develop useful insight and solutions. This phase, Phase 1, was funded with American Recovery and Reinvestment Act (ARRA) funds. This version of the final report is organized to align with statement of project objectives (SOPO) critical milestones.

14 SOLAR ENERGY↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗