Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Distributed Conditions for Small-signal Stability of Power Grids and Local Control Design

Operating modern power grids with stability guarantees is markedly important. Typical methods for analyzing and certifying power grid stability are largely centralized relying on the ability of the system operator to gather network-wide information and accurately compute the system's eigenvalues. These methods are oftentimes not privacy-preserving and computationally burdensome. They are therefore, not well-suited to modern power grids where small-signal stability has to be evaluated timely, efficiently and in a privacy-preserving fashion. Herein, we introduce a distributed methodology for certifying small-signal stability of power grids and designing the local controllers. First, we analytically derive distributed conditions for network-wide stability that bus agents can inspect using local information. By leveraging these conditions, we then introduce a distributed control design algorithm (DCDA) that can guide the local control design so that stability of the interconnected system is guaranteed. The agents that adopt the proposed distributed algorithm are responsible for tuning their local controllers, producing their local control commands and ensuring that their local stability condition is met. The system operator is only responsible for verifying network-wide stability upon receiving affirmative responses from all agents and, announcing, that the overall system is stable. The proposed DCDA algorithm is numerically validated via simulations using the IEEE 39-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal dc signal conditioner

Signal conditioner was designed which can condition dc signals over range of + or - volts. It is lighter, has lower initial and maintenance costs, and higher reliability than conventional discrete circuit designs. System incorporates linear integrated circuits in conjunction with hybrid, thin film circuit technology to achieve high degree of circuit miniaturization.

Bradanini, P. A.↗

Interstellar laser communication: implementability criterion and optimisation conditions for the addressed signal search and sending

Using new opportunities offered by the construction of large optical telescopes, a laser radiation receiver with an iodine active quantum filter, high-energy iodine lasers with a diffraction-limited beam divergence and the discovery of exoplanets of the Earth type, including those located relatively not far from the Sun, we analyse the implementability of interstellar laser communication under the conditions, when the central spot of the diffraction pattern at the place of the laser signal reception by means of large optical telescopes can be made smaller than the orbit of the planet, and the signals come to the specified point of the orbit not synchronously with the planet motion because of the error in the determination of the distance between the Sun and the star, around which the planet chosen for communication rotates. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexing electro-optic architectures for advanced aircraft integrated flight control systems

This report describes the results of a 10 month program sponsored by NASA. The objective of this program was to evaluate various optical sensor modulation technologies and to design an optimal Electro-Optic Architecture (EOA) for servicing remote clusters of sensors and actuators in advanced aircraft flight control systems. The EOA's supply optical power to remote sensors and actuators, process the modulated optical signals returned from the sensors, and produce conditioned electrical signals acceptable for use by a digital flight control computer or Vehicle Management System (VMS) computer. This study was part of a multi-year initiative under the Fiber Optic Control System Integration (FOCSI) program to design, develop, and test a totally integrated fiber optic flight/propulsion control system for application to advanced aircraft. Unlike earlier FOCSI studies, this program concentrated on the design of the EOA interface rather than the optical transducer technology itself.

Seal, D. W.↗

Apparatus for detecting at least one predetermined condition and providing an informational signal in response thereto in a medication infusion system

A medication infusion system provides redundant safety and includes condition detecting and informational alarm signal generating apparatus for indicating if (1) a fluid leak occurs in different portions of the system; (2) a programmable input from a patient or physician would result in exceeding a safe dosage limit; (3) the reservoir containing medication has been filled; (4) the intended medication pumping does not correlate with the pumping actually effected; (5) battery voltage is low; (6) the medication reserve is low; and (7) the system has been switched off. The apparatus may provide subcutaneous electrical, thermal, or audible stimulation to the patient and also provides a signal which a physician may monitor. The stimulation may be coded to separately identify each above-listed deviation in nominal system performance. In addition, the number of medication requests are correlated with actual medication dispensing to assure proper operation. An identification scheme is provided which matches the patient with his or her corresponding medication.

Fischell, Robert E.↗

Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

60 APPLIED LIFE SCIENCES↗

On signal design by the R sub 0 criterion for non-white Gaussian noise channels

The use of the R sub 0 criterion for modulation system design is investigated for channels with non-white Gaussian noise. A signal space representation of the waveform channel is developed, and the cut-off rate R sub 0 for vector channels with additive nonwhite Gaussian noise and unquantized demodulation is derived. When the signal unput to the channel is a continuous random vector, maximization of R sub 0 with constrained average signal energy leads to a water-filling interpretation of optimal energy distribution in signal space. The necessary condition for a finite signal set to maximize R sub 0 with constrained energy and an equally likely probability assignment of signal vectors is presented, and an algorithm is outlined for numerically computing the optimum signal set. A necessary condition on a constrained energy, finite signal set is found which maximizes a Taylor series approximation of R sub 0. This signal set is compared with the finite signal set which has the water-filling average energy distribution.

Bordelon, D. L.↗

Beamforming in an acoustic shadow

The sound field deep within an acoustic shadow region is less well understood than that outside the shadow region. Signal levels are substantially lower within the shadow, but beamforming difficulties arise for other reasons such as loss of spatial coherence. Based on analysis of JAPE-91 data, and other data, three types of characteristic signals within acoustic shadow regions are identified. These signal types may correspond to different, intermittent signal propagation conditions. Detection and classification algorithms might take advantage of the signal characteristics. Frequency coherence is also discussed. The extent of coherence across frequencies is shown to be limited, causing difficulties for source classification based on harmonic amplitude relationships. Discussions emphasize short-term characteristics on the order of one second. A video presentation on frequency coherence shows the similarity, in the presence of atmospheric turbulence, between the received signal from a stable set of harmonics generated by a loudspeaker and that received from a helicopter hovering behind a hill.

Havelock, David↗

Low-Cutoff, High-Pass Digital Filtering of Neural Signals

The figure depicts the major functional blocks of a system, now undergoing development, for conditioning neural signals acquired by electrodes implanted in a brain. The overall functions to be performed by this system can be summarized as preamplification, multiplexing, digitization, and high-pass filtering. Other systems under development for recording neural signals typically contain resistor-capacitor analog low-pass filters characterized by cutoff frequencies in the vicinity of 100 Hz. In the application for which this system is being developed, there is a requirement for a cutoff frequency of 5 Hz. Because the resistors needed to obtain such a low cutoff frequency would be impractically large, it was decided to perform low-pass filtering by use of digital rather than analog circuitry. In addition, it was decided to timemultiplex the digitized signals from the multiple input channels into a single stream of data in a single output channel. The signal in each input channel is first processed by a preamplifier having a voltage gain of approximately 50. Embedded in each preamplifier is a low-pass anti-aliasing filter having a cutoff frequency of approximately 10 kHz. The anti-aliasing filters make it possible to couple the outputs of the preamplifiers to the input ports of a multiplexer. The output of the multiplexer is a single stream of time-multiplexed samples of analog signals. This stream is processed by a main differential amplifier, the output of which is sent to an analog-to-digital converter (ADC). The output of the ADC is sent to a digital signal processor (DSP).

Mojarradi,Mohammad↗

Operational-Condition-Independent Criteria Dedicated to Monitoring Wind Turbine Generators: Preprint

To date the existing wind turbine condition monitoring technologies and commercially available systems have not been fully accepted for improving wind turbine availability and reducing their operation and maintenance costs. One of the main reasons is that wind turbines are subject to constantly varying loads and operate at variable rotational speeds. As a consequence, the influences of turbinefaults and the effects of varying load and speed are coupled together in wind turbine condition monitoring signals. So, there is an urgent need to either introduce some operational condition de-coupling procedures into the current wind turbine condition monitoring techniques or develop a new operational condition independent wind turbine condition monitoring technique to maintain high turbineavailability and achieve the expected economic benefits from wind. The purpose of this paper is to develop such a technique. In the paper, three operational condition independent criteria are developed dedicated for monitoring the operation and health condition of wind turbine generators. All proposed criteria have been tested through both simulated and practical experiments. The experimentshave shown that these criteria provide a solution for detecting both mechanical and electrical faults occurring in wind turbine generators.

17 WIND ENERGY↗

Production of Mg and Al Auger electrons by noble gas ion bombardment of Mg and Al surfaces

Relative production efficiencies of Mg and Al Auger electrons by He, Ne, Ar, Kr, and Xe ion bombardment are reported as a function of ion energy for energies not exceeding 3 keV. The experimental apparatus employed consisted of a LEED-Auger system equipped with an ion gun and a four-grid retarding-potential analyzer. It is found that: (1) the shape of the ion-excited Auger signal was independent of the rare gas and quite symmetric; (2) the Al signal was about an order of magnitude smaller than the Mg signal for a given bombarding species and ion-gun voltage; (3) no signal was observed for He(+) bombardment under any of the experimental conditions; (4) signal strengths were independent of temperature and ion dose; (5) the Auger production efficiencies differed by no more than a factor of two among the different gases - except for He(+) - on a given metal; (6) all the signal strengths increased with increasing ion-gun voltage, with no maximum exhibited; and (7) the apparent threshold energy for the Al signal was higher than that for the Mg signal. The differences between the results for the two metals are attributed to the fact that the Al 2p orbital lies deeper in energy and closer to the nucleus than the corresponding Mg orbital.

Ferrante, J.↗

Pattern-Recognition Algorithm for Locking Laser Frequency

A computer program serves as part of a feedback control system that locks the frequency of a laser to one of the spectral peaks of cesium atoms in an optical absorption cell. The system analyzes a saturation absorption spectrum to find a target peak and commands a laser-frequency-control circuit to minimize an error signal representing the difference between the laser frequency and the target peak. The program implements an algorithm consisting of the following steps: Acquire a saturation absorption signal while scanning the laser through the frequency range of interest. Condition the signal by use of convolution filtering. Detect peaks. Match the peaks in the signal to a pattern of known spectral peaks by use of a pattern-recognition algorithm. Add missing peaks. Tune the laser to the desired peak and thereafter lock onto this peak. Finding and locking onto the desired peak is a challenging problem, given that the saturation absorption signal includes noise and other spurious signal components; the problem is further complicated by nonlinearity and shifting of the voltage-to-frequency correspondence. The pattern-recognition algorithm, which is based on Hausdorff distance, is what enables the program to meet these challenges.

Karayan, Vahag↗

Adaptive analog video signal conditioner

This paper presents an adaptive analog video signal conditioner. This system supplements conventional irises and automatic gain controls to condition video signals for digitizing with a uniform analog-to-digital converter. Employing two degree of freedom, this circuit adjusts an analog gain and analog offset to increase the average information content of digitized images as defined by an entropy measure. The globally near-optimized implementation tracks smoothly to adapt to changing scene conditions.

Jeong, Cheol-Ho↗

Using Artificial Neural Network in Nuclear Spin Echo Experiments

The possibility of using an artificial neural network for discriminating nuclear spin echo signals recorded under conditions where the echo signal intensity is comparable to the noise amplitude is demonstrated. It is proposed to teach the neural network using data obtained by superposition of the model Gaussian signals onto experimentally measured noise signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Setup and Testing of PSEC5 ASIC Boards

The PSEC5 ASIC is a high-speed waveform sampling chip developed for precise measurements. This report presents the design review, test board configurations, and results from functional validation of the PSEC5 device. Key aspects examined include power integrity, voltage-controlled oscillator (VCO) behavior, SPI register functionality, clock division characteristics, readout performance, and analog biasing response. Tests were conducted across two boards under varied voltage conditions and signal configurations. Notable observations include robust VCO output, SPI communication irregularities, and anomalous readout conditions. The findings support design iterations for improved ASIC operability and firmware integration.

Fahey, Alexander [North Central Coll.]↗