Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Compliant Tactile Sensors

Tactile sensors are currently being designed to sense interactions with human hands or pen-like interfaces. They are generally embedded in screens, keyboards, mousepads, and pushbuttons. However, they are not well fitted to sense interactions with all kinds of objects. A novel sensor was originally designed to investigate robotics manipulation where not only the contact with an object needs to be detected, but also where the object needs to be held and manipulated. This tactile sensor has been designed with features that allow it to sense a large variety of objects in human environments. The sensor is capable of detecting forces coming from any direction. As a result, this sensor delivers a force vector with three components. In contrast to most of the tactile sensors that are flat, this one sticks out from the surface so that it is likely to come in contact with objects. The sensor conforms to the object with which it interacts. This augments the contact's surface, consequently reducing the stress applied to the object. This feature makes the sensor ideal for grabbing objects and other applications that require compliance with objects. The operational range of the sensor allows it to operate well with objects found in peoples' daily life. The fabrication of this sensor is simple and inexpensive because of its compact mechanical configuration and reduced electronics. These features are convenient for mass production of individual sensors as well as dense arrays. The biologically inspired tactile sensor is sensitive to both normal and lateral forces, providing better feedback to the host robot about the object to be grabbed. It has a high sensitivity, enabling its use in manipulation fingers, which typically have low mechanical impedance in order to be very compliant. The construction of the sensor is simple, using inexpensive technologies like silicon rubber molding and standard stock electronics.

Torres-Jara, Eduardo R.↗

Onboard Sensor Data Qualification in Human-Rated Launch Vehicles

The avionics system software for human-rated launch vehicles requires an implementation approach that is robust to failures, especially the failure of sensors used to monitor vehicle conditions that might result in an abort determination. Sensor measurements provide the basis for operational decisions on human-rated launch vehicles. This data is often used to assess the health of system or subsystem components, to identify failures, and to take corrective action. An incorrect conclusion and/or response may result if the sensor itself provides faulty data, or if the data provided by the sensor has been corrupted. Operational decisions based on faulty sensor data have the potential to be catastrophic, resulting in loss of mission or loss of crew. To prevent these later situations from occurring, a Modular Architecture and Generalized Methodology for Sensor Data Qualification in Human-rated Launch Vehicles has been developed. Sensor Data Qualification (SDQ) is a set of algorithms that can be implemented in onboard flight software, and can be used to qualify data obtained from flight-critical sensors prior to the data being used by other flight software algorithms. Qualified data has been analyzed by SDQ and is determined to be a true representation of the sensed system state; that is, the sensor data is determined not to be corrupted by sensor faults or signal transmission faults. Sensor data can become corrupted by faults at any point in the signal path between the sensor and the flight computer. Qualifying the sensor data has the benefit of ensuring that erroneous data is identified and flagged before otherwise being used for operational decisions, thus increasing confidence in the response of the other flight software processes using the qualified data, and decreasing the probability of false alarms or missed detections.

Wong, Edmond↗

Dynamic Range and Sensitivity Requirements of Satellite Ocean Color Sensors: Learning from the Past

Sensor design and mission planning for satellite ocean color measurements requires careful consideration of the signal dynamic range and sensitivity (specifically here signal-to-noise ratio or SNR) so that small changes of ocean properties (e.g., surface chlorophyll-a concentrations or Chl) can be quantified while most measurements are not saturated. Past and current sensors used different signal levels, formats, and conventions to specify these critical parameters, making it difficult to make cross-sensor comparisons or to establish standards for future sensor design. The goal of this study is to quantify these parameters under uniform conditions for widely used past and current sensors in order to provide a reference for the design of future ocean color radiometers. Using measurements from the Moderate Resolution Imaging Spectroradiometer onboard the Aqua satellite (MODISA) under various solar zenith angles (SZAs), typical (L(sub typical)) and maximum (L(sub max)) at-sensor radiances from the visible to the shortwave IR were determined. The Ltypical values at an SZA of 45 deg were used as constraints to calculate SNRs of 10 multiband sensors at the same L(sub typical) radiance input and 2 hyperspectral sensors at a similar radiance input. The calculations were based on clear-water scenes with an objective method of selecting pixels with minimal cross-pixel variations to assure target homogeneity. Among the widely used ocean color sensors that have routine global coverage, MODISA ocean bands (1 km) showed 2-4 times higher SNRs than the Sea-viewing Wide Field-of-view Sensor (Sea-WiFS) (1 km) and comparable SNRs to the Medium Resolution Imaging Spectrometer (MERIS)-RR (reduced resolution, 1.2 km), leading to different levels of precision in the retrieved Chl data product. MERIS-FR (full resolution, 300 m) showed SNRs lower than MODISA and MERIS-RR with the gain in spatial resolution. SNRs of all MODISA ocean bands and SeaWiFS bands (except the SeaWiFS near-IR bands) exceeded those from prelaunch sensor specifications after adjusting the input radiance to L(sub typical). The tabulated L(sub typical), L(sub max), and SNRs of the various multiband and hyperspectral sensors under the same or similar radiance input provide references to compare sensor performance in product precision and to help design future missions such as the Geostationary Coastal and Air Pollution Events (GEO-CAPE) mission and the Pre-Aerosol-Clouds-Ecosystems (PACE) mission currently being planned by the U.S. National Aeronautics and Space Administration (NASA).

chlorophyll fluorescence↗

Hydrogen Safety Sensor Performance and Use Gap Analysis: Preprint

Hydrogen sensors are recognized as an important technology for facilitating the safe implementation of hydrogen as an alternative fuel, and there are numerous reports of a sensor alarm successfully preventing a potentially serious event. However, gaps in sensor metrological specifications, as well as in their performance for some applications, exist.The U.S. Department of Energy (DOE) Fuel Cell Technology Office published a short list of critical gaps in the 2007 and 2012 multiyear project plans; more detailed gap analyses were independently performed by the JRC and NREL. There have been, however, some significant advances in sensor technologies since these assessments, including the commercial availability of hydrogen sensors with fast response times (t90 less than 1 s, which had been an elusive DOE target since 2007), improved robustness to chemical poisons, improved selectivity, and improved lifetime and stability. These improvements, however, have not been universal and typically pertain to select platforms or models. Moreover, as hydrogen markets grow and new applications are being explored, more demands will be imposed on sensor performance. The hydrogen sensor laboratories at NREL and JRC are currently updating the hydrogen safety sensor gap analysis through direct interaction with international stakeholders in the hydrogen community, especially end-users. NREL and the JRC are currently organizing a series of workshops (in Europe and the U.S.) with sensor developers, end-users, and other stakeholders in 2017 to identify technology gaps and to develop a path forward to address them. One workshop is scheduled for May 10 in Brussels, Belgium at the Headquarters of the Fuel Cell and Hydrogen Joint Undertaking. A second workshop is planned at the National Renewable Energy Laboratory in Golden, CO, USA. This presentation will review improvements in sensor technologies in the past 5 to 10 years, identify gaps in sensor performance and use requirements, and identify potential research strategies to address the gaps. The presentation will also summarize the outcomes of the Hydrogen Sensors Workshops.

30 DIRECT ENERGY CONVERSION↗

Performance evaluation of ZnO–CuO hetero junction solid state room temperature ethanol sensor

Graphical abstract: Sensor response (resistance) curves of time were changed from 150 ppm to 250 ppm alcohol concentration of ZnO–CuO 1:1. The response and recovery times were measured to be 62 and 83 s, respectively. The sensing material ZnO–CuO is a high potential alcohol sensor which provides a simple, rapid and highly sensitive alcohol gas sensor operating at room temperature. Highlights: ► The main advantages of the ethanol sensor are as followings. ► Novel materials ZnO–CuO ethanol sensor. ► The optimized ZnO–CuO hetero contact system. ► A good sensor response and room working temperature (save energy). -- Abstract: A semiconductor ethanol sensor was developed using ZnO–CuO and its performance was evaluated at room temperature. Hetero-junction sensor was made of ZnO–CuO nanoparticles for sensing alcohol at room temperature. Nanoparticles were prepared by hydrothermal method and optimized with different weight ratios. Sensor characteristics were linear for the concentration range of 150–250 ppm. Composite materials of ZnO–CuO were characterized using X-ray diffraction (XRD), temperature-programmed reduction (TPR) and high-resolution transmission electron microscopy (HR-TEM). ZnO–CuO (1:1) material showed maximum sensor response (S = R{sub air}/R{sub alcohol}) of 3.32 ± 0.1 toward 200 ppm of alcohol vapor at room temperature. The response and recovery times were measured to be 62 and 83 s, respectively. The linearity R{sup 2} of the sensor response was 0.9026. The sensing materials ZnO–CuO (1:1) provide a simple, rapid and highly sensitive alcohol gas sensor operating at room temperature.

36 MATERIALS SCIENCE↗

Initial tests of large format sensors for the ATLAS ITk strip tracker

For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector for the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n + -in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98 × 98 mm 2 and are designed and engineered for tolerance against the 9.7 × 10 14 1 MeV n eq /cm 2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μ m horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmarking Soft Sensors for Remote Monitoring of On-Site Wastewater Treatment Plants

On-site wastewater treatment plants (OSTs) are usually unattended, so failures often remain undetected and lead to prolonged periods of reduced performance. To stabilize the performance of unattended plants, soft sensors could expose faults and failures to the operator. In a previous study, we developed soft sensors and showed that soft sensors with data from unmaintained physical sensors can be as accurate as soft sensors with data from maintained ones. The monitored variables were pH and dissolved oxygen (DO), and soft sensors were used to predict nitrification performance. In the present study, we use synthetic data and monitor three plants to test these soft sensors. We find that a long solids retention time and a moderate aeration rate improve the pH soft-sensor accuracy and that the aeration regime is the main operational parameter affecting the accuracy of the DO soft sensor. We demonstrate that integrated design of monitoring and control is necessary to achieve robustness when extrapolating from one OST to another in the absence of plant-specific fine-tuning. Additionally, we provide a unique labeled dataset for further feature and data-driven soft-sensor development. Our benchmarking results indicate that it is feasible to monitor OSTs with unmaintained sensors and without plant-specific tuning of the developed soft sensors. This is expected to drastically reduce monitoring costs for OST-based sanitation systems.

54 ENVIRONMENTAL SCIENCES↗

In situ measurement of gas composition changes in radio frequency plasmas using a quartz sensor

A simple method using a quartz sensor (Q-sensor) was developed to observe gas composition changes in radio frequency (rf) plasmas. The output depends on the gases' absolute pressure, molecular weight, and viscosity. The pressure-normalized quartz sensor output depends only on the molecular weight and viscosity of the gas. Consequently, gas composition changes can be detected in the plasmas if a sensor can be used in the plasmas. Influences imparted by the plasmas on the sensor, such as those by reactive particles (e.g., radicals and ions), excited species, electrons, temperature, and electric potentials during measurements were investigated to test the applicability of this quartz sensor measurement to plasma. The Q-sensor measurement results for rf plasmas with argon, hydrogen, and their mixtures are reproducible, demonstrating that the Q-sensor measurement is applicable for plasmas. In this work, pressure- and temperature-normalized Q-sensor output (NQO) were used to obtain the gas composition information of plasma. Temperature-normalization of the Q-sensor output enabled quartz sensor measurements near plasma electrodes, where the quartz sensor temperature increases. The changes in NQO agreed with results obtained by gas analysis using a quadrupole mass spectrometer. Results confirmed that the change in NQO is mainly attributable to changes in the densities and kinds of gas molecules in the plasma gas phase, not by other extrinsic influences of plasma. For argon, hydrogen, and argon-hydrogen plasmas, these changes correspond to reduction in nitrogen, production of carbon monoxide, and dissociation of hydrogen molecules, respectively. These changes in NQO qualitatively and somewhat quantitatively agreed with results obtained using gas analysis, indicting that the measurement has a potential application to obtain the gas composition in plasmas without disturbing industrial plasma processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Analysis of Capacitive Sensors with Different Geometrical layouts for Cable Insulation Degradation Detection

This paper presents a comparative analysis between an Interdigital Capacitor (IDC) sensor and a Serpentine Capacitive (SRC) sensor. The effects of electrode layouts on sensor performance are studied by means of finite element simulation where the geometrical dimensions (except electrode length) and material characteristics of both sensors are identical. Conformal IDC and SRC sensors with equal sensor area are modeled on a cable surface. The simulation results show a tradeoff between IDC and SRC sensors in terms of sensitivity and penetration depth. The SRC sensor shows 13.3% increase in sensitivity and 16.8% increase in capacitance compared to the IDC sensor, though the electric field penetration depth of the SRC sensor is 18.8% lower than the IDC sensor. In addition, the effects of change in electrode width, inter-electrode gap, and number of electrodes on SRC and IDC sensor comparative performance are evaluated.

Interdigital Capacitance, Serpentive Capacitive Se↗

Calibration Monitoring for Sensor Calibration Interval Extension: Gaps in the Current Science Base

Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. International application of calibration monitoring has shown that sensors may operate for longer periods within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. Online monitoring (OLM) can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of OLM for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This paper summarizes a recent state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and OLM algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several technical needs were identified, including an understanding of the impacts of sensor degradation on measurements for both conventional and emerging sensors; the quantification of uncertainty in online calibration assessment; determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity.

Calibration Interval Extension↗

A Synchronized Sensor Array for Remote Monitoring of Avian and Bat Interactions with Offshore Renewable Energy Facilities

Wind energy production in the U.S. is projected to increase to 35% of our nation’s energy by 2050. This substantial increase in the U.S. is only a portion of the global wind industry growth, as many countries strive to reduce greenhouse gas emissions. A major environmental concern and potential market barrier for expansion of wind energy is bird and bat mortality from impacts with turbine blades, towers, and nacelles. Carcass surveys are the standard protocol for quantifying mortality at onshore sites. This method is imperfect, however, due to survey frequency at remote sites, removal of carcasses by scavengers between surveys, searcher efficiency, and other biases as well as delays of days to weeks or more in obtaining information on collision events. Furthermore, carcass surveys are not feasible at offshore wind energy sites. Near-real-time detection and quantification of interaction rates is possible at both onshore and offshore wind facilities using an onboard, integrated sensor package with data transmitted to central processing centers. We developed and experimentally tested an array of sensors that continuously monitors for interactions (including impacts) of birds and bats with wind turbines. The synchronized array includes three sensor nodes: (1) vibration (accelerometers and contact microphones), (2) optical (visual and infrared spectrum cameras), and (3) bioacoustics (acoustic and ultrasonic microphones). Accelerometers and contact acoustic microphones are placed at the root of each blade to detect impact vibrations and sound waves propagating through the structure. On-board data processing algorithms using wavelet analysis detect impact signals exceeding background vibration. Stereo-visual and infrared cameras were placed on the nacelle to allow target tracking, distance, and size calculations. On-board image processing and target detection algorithms identify moving targets within the camera field of view. Bioacoustic recorders monitor vocalizations and echolocations to aid in identifying organisms involved in interactions. Data from all sensors are temporarily stored in ring (i.e., circular) buffers with a duration varying by sensor type. Detection of target presence or impact by any of the sensors can trigger the archiving of data from all buffers for transmission to a central data processing center for evaluation and post-processing. This mitigates the risk of “data mortgages” posed by continual recording and minimizes personnel time required to manually review event data. We first conducted individual component tests at laboratories and field sites in Corvallis and Newport, Oregon, and Seattle and Sequim, Washington. We conducted additional component tests on research wind turbines at the North American Wind Research and Training Center, Mesalands Community College (MCC; General Electric 1.5 MW turbine), New Mexico, and the National Wind Technology Center, National Renewable Energy Laboratory (NREL; Controls Advanced Research Turbines 3 [CART 3] 600 kW Westinghouse turbine), Colorado. We conducted fully integrated system tests at NREL in October 2014 and April 2015. We used only research wind turbines so that we could conduct controlled, experimentally generated impacts using empty and water-filled tennis balls shot from a compressed air cannon on the ground. The approx. 57-140 g tennis balls (depending on water content) were at the upper mass range for bats, but lower mass range for marine birds. Therefore, the ability to detect collisions of most seabirds is likely greater than our experiments demonstrate, but possibly lower for some bats depending on the background signal of a given turbine. Vibration data demonstrated that background signals of operating turbines varied markedly among the CART 3 under normal operation (greatest), GE (moderate), and CART 3 during idle rotation (generator not engaged; least). In total, we measured 63 experimental blade impacts on the two research turbines. Impaction detection was dependent on background signals, position of impact on the blade (a tip strike resulted in the strongest impact signal), and impact kinetics (velocity of ball and whether the ball struck the surface of the blade or the leading edge of the blade struck the ball). Overall detection percentage ranged from 100% for the “quietest” conditions (CART 3 idle rotation), down to 35% for the noisiest (CART 3 normal operation). Impact signals were detected from sensors on more than one blade (i.e., blades other than the blade struck) 50% - 75% of the time. Stereo imaging provided valuable metrics, but increased data processing and equipment cost. Given the cost of cameras with sufficient resolution for target identification, we suggest mounting cameras directly on the blades to continuously view the entire rotor swept area with the fewest number of cameras. Bioacoustic microphones provide taxonomic identification, as well as information on ambient noise levels. They also assist in identifying environmental conditions such as hail storms, high winds, thunder, lightning, etc., that may contribute to a collision or a false positive detection. We demonstrated a proof of concept for an integrated sensor array to detect and identify bird and bat collisions with wind turbines. The next phase of research and development for this system will miniaturize and integrate sensors from all three nodes into a single wireless package that can be attached directly to the blade. This next generation system would use all “smart” sensors capable of onboard data processing to drastically reduce data streams and processing time on a central computer. A provisional patent for the blade mounted system was submitted by Oregon State University and recorded by the U.S. Patent and Trademark Office (application no. 62313028). Eventually, technology and industry advances will allow this low cost monitoring system to be designed into materials during manufacturing so that all turbines could be monitored with either a subset or full suite of sensors. As standard equipment on all commercial turbines, the sensor suite would allow the industry to effectively monitor whether individual turbines were causing mortalities or not and under what circumstances. It would also provide real-time evaluation of mechanical and structural integrity of a turbine via vibration, image, and acoustic data streams, thereby permitting modifications in operation to limit environmental or mechanical damage.

17 WIND ENERGY↗

Wearable Sensor Application for Integrated Early Warning and Health Surveillance

Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health using physiologic and environmental indicators. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and landscape data, and calculates the corresponding physiological strain index. The information is presented to the analyst in a group and individual view with real-time alerting of abnormal health parameters. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agency's Biosurveillance Ecosystem (BSVE).Introduction: Wearable devices are a low cost, minimally invasive way to monitor health. Sensor data provides real-time physiological indictors of an individual’s health status without the requirement of health care professionals or facilities. Information gleamed from wearable sensors can be used to better understand physiological stressors and prodromal symptoms. In addition, this data can be used to monitor individuals that are in high risk of health-related problems.However, raw data from wearable sensors can be overwhelming to process and laborious to monitor for an individual and, even more so, for a group of individuals. Often specific combination of ranges of sensor readings are indicative of changes to health status and need to be evaluated together or used to calculate specific signal parameters. In addition, the environment surrounding the individual needs to be considered when interpreting the data. To address these issues, PNNL has developed an application that collects, analyzes, and integrates wearable sensor data with geographic landscape and weather information to provide a real-time early alert and situational awareness tool for monitoring the health of groups and individuals.Methods: The prototype application described here was a product of PNNL’s BSVE Application Development Competition. The final product that will be deployed in the BSVE is currently under development by PNNL and will vary slightly in the exact design and architecture described.Data. Wearable sensor data was collected from the Rim2Rim (R2R) Watch Study of individuals hiking the Grand Canyon in Arizona [1]. Weather information was obtained from nearby weather stations and mapping features were derived from Google Maps.Calculations. A physiological Strain Index (PSI) was calculated using core temperature estimates derived through a Kalman Filter approach and heart rate [2,3].Application. The prototype backend application development was based in Python with a MongoDB. The front-end development was built using a scalable architecture and modular approach with components in React and D3.Results: A prototype application was developed this past summer through the PNNL BSVE App Competition (Fig 1). The application was aimed at visualizing wearable sensor data from the Grand Canyon R2R hike dataset. Simulated real-time analysis was used to calculate health status of individuals hiking based on measured physiological parameters and to alert to individuals with signs of physiologic health stress. Visualization tools were incorporated to enable sensor data for individuals and the group to be viewed simultaneously along with pertinent weather, geographic, and elevation data.Many features described in the prototype application will be incorporated into the final BSVE application. The key changes will be 1) the ability to select given time periods for viewing historical data as well as the real-time data collection, 2) environmental data and map view will come from BSVE internal data sources, and 3) the alerts will provide more information and have their own page for reviewing.Conclusions: The Wearable Sensor Application developed by PNNL for integration into the BSVE provides an early warning system for individual and group health using physiologic and environmental parameters. The application highlights health status from wearable sensors and relevant environmental parameters while monitoring a calculated physiological strain index. With this tool, an analyst can easily monitor the health of individuals and groups with the aid of real-time alerting tool for early detection of abnormal health parameters.

Early Warning↗

Overview of the U.S. DOE Hydrogen Safety, Codes and Standards Program. Part 4: Hydrogen Sensors; Preprint

Hydrogen sensors are recognized as a critical element in the safety design for any hydrogen system. In this role, sensors can perform several important functions including indication of unintended hydrogen releases, activation of mitigation strategies to preclude the development of dangerous situations, activation of alarm systems and communication to first responders, and to initiate system shutdown. The functionality of hydrogen sensors in this capacity is decoupled from the system being monitored, thereby providing an independent safety component that is not affected by the system itself. The importance of hydrogen sensors has been recognized by DOE and by the Fuel Cell Technologies Office's Safety and Codes Standards (SCS) program in particular, which has for several years supported hydrogen safety sensor research and development. The SCS hydrogen sensor programs are currently led by the National Renewable Energy Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory. The current SCS sensor program encompasses the full range of issues related to safety sensors, including development of advance sensor platforms with exemplary performance, development of sensor-related code and standards, outreach to stakeholders on the role sensors play in facilitating deployment, technology evaluation, and support on the proper selection and use of sensors.

30 DIRECT ENERGY CONVERSION↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Response characteristics of stable mixed-potential NH 3 sensors in diesel engine exhaust

Here, a mixed-potential, electrochemical sensor platform is extended to NH 3 sensing by the introduction of a new gold alloy working electrode. A planar, pre-commercial NH 3 sensor utilized LANL’s controlled interface approach, and a Pd-Au alloy working electrode was tested in exhaust of a GM 1.9 L diesel engine downstream of a diesel oxidation catalyst through a slipstream arrangement. A fraction of the exhaust was pulled across the sensor with a pump at 20 L/min. In order to simulate NH 3 slip inside of a full SCR emissions control system, NH 3 was injected immediately upstream of the sensor using a calibrated mass flow controller. The sensor response quantitatively tracked the NH 3 as measured via Fourier transform infrared (FTIR) analyzer. A calibration curve was obtained in the exhaust from an ammonia staircase response with the engine running at steady-state engine conditions resulting in low background concentrations of NO x and HC (<20 ppm) during calibration. Exhaust gas recirculation (EGR) switching and sweeps were used to evaluate the NH 3 sensor response under different amounts of total background NO x . The calibration curve was used to directly compare the [NH 3 ] calculated from sensor response to the gas phase composition measured via FTIR. In general, there was excellent quantitative agreement between the sensor response and the actual NH 3 in the exhaust gas, and fast response time such that transients (<5 ppm) could be easily discerned from baseline. A LANL pre-commercial NO x sensor was tested simultaneously with the NH 3 sensor and the extent of cross-sensitivity between the two sensors will be discussed.

47 OTHER INSTRUMENTATION↗

Fiber-Optic Sensor with Simultaneous Temperature, Pressure, and Chemical Sensing Capabilities

This project aimed to develop a multifunctional sensor suitable for process control application in chemical and petrochemical industries. Specifically, the objective was to demonstrate a fiber optic sensing system capable of simultaneous temperature, pressure, and chemical composition determinations based on a single strand of sapphire optical fiber. These capabilities were to be achieved through the incorporation of a phosphor and a Bragg grating into the fiber, as well as the exploitation of the evanescent field interaction of the optical radiation inside the fiber with the surrounding chemical medium. The integration of the three functions into a single probe, compared to having three separate probes, would not only substantially reduce the cost of the combined system, but would also minimize the intrusion into the reactor. Such a device can potentially increase the energy efficiency in the manufacture of chemical and petrochemical products, as well as reduce waste and lead to improved quality. In accordance with the proposed research plan, the individual temperature, pressure and chemical sensors where fabricated and characterized first. Then towards the end of the program, an integrated system was implemented. The sapphire fibers were grown on a laser heated pedestal growth system. The temperature sensor was based on the fluorescence decay principle, which exploits the temperature dependence of the fluorescence decay rate of the selected phosphor. For this project, Cr 3+ was chosen as the phosphor, and it was incorporated into the sapphire fiber by coating a short length of the source rod with a thin layer of Cr 2 O 3 . After the viability of the technique was established and the growth parameters optimized, the temperature sensor was characterized up to 300 °C and its long term stability was verified. The chemical sensor determined the concentration of chemicals through evanescent field absorption. Techniques to increase the sensitivity of the evanescent field interaction such as tapering and coiling the fiber were successfully demonstrated. It was shown that the sensor is capable of quantitative measurements in both the mid-infrared and the near infrared regions of the spectrum. For the pressure sensor, a novel concept involving a pressure amplifier was investigated. While the basic idea was found to work, technical difficulties prevented the demonstration of a sensor capable of quantitative pressure measurements. As a result, the final combined probe contained only a temperature sensor and a chemical sensor. Under this program not only was the technical feasibility of a dual temperature/chemical sensor demonstrated, so were those of two ancillary devices. The first is a scan-and-dwell fiber optic mid-IR spectrometer specifically designed for process control applications. Also, a versatile high-brightness fiber optic light source with interchangeable emitting elements to cover different spectral regions has been demonstrated. The commercial potentials of the complete system as well as the individual components are being actively explored now.

02 PETROLEUM↗

Structures and solution properties of two novel periplasmic sensor domains with c-type heme from chemotaxis proteins of Geobacter sulfurreducens : implications for signal transduction.

Periplasmic sensor domains from two methyl-accepting chemotaxis proteins from Geobacter sulfurreducens (encoded by genes GSU0935 and GSU0582) were expressed in Escherichia coli. The sensor domains were isolated, purified, characterized in solution, and their crystal structures were determined. In the crystal, both sensor domains form swapped dimers and show a PAS-type fold. The swapped segment consists of two helices of about 45 residues at the N terminus with the hemes located between the two monomers. In the case of the GSU0582 sensor, the dimer contains a crystallographic 2-fold symmetry and the heme is coordinated by an axial His and a water molecule. In the case of the GSU0935 sensor, the crystals contain a non-crystallographic dimer, and surprisingly, the coordination of the heme in each monomer is different; monomer A heme has His-Met ligation and monomer B heme has His-water ligation as found in the GSU0582 sensor. The structures of these sensor domains are the first structures of PAS domains containing covalently bound heme. Optical absorption, electron paramagnetic resonance and NMR spectroscopy have revealed that the heme groups of both sensor domains are high-spin and low-spin in the oxidized and reduced forms, respectively, and that the spin-state interconversion involves a heme axial ligand replacement. Both sensor domains bind NO in their ferric and ferrous forms but bind CO only in the reduced form. The binding of both NO and CO occurs via an axial ligand exchange process, and is fully reversible. The reduction potentials of the sensor domains differ by 95 mV (-156 mV and -251 mV for sensors GSU0582 and GSU0935, respectively). The swapped dimerization of these sensor domains and redox-linked ligand switch might be related to the mechanism of signal transduction by these chemotaxis proteins.

36 MATERIALS SCIENCE↗

Stability of Pt/Al 2 O 3 -Based Electrode Langasite SAW Sensors with Al 2 O 3 Capping Layer and Yttria-Stabilized Zirconia Sensing Layer

Surface acoustic wave (SAW) devices have been shown recently to be an appropriate technology for harsh environment sensor applications, such as those in the automotive, aerospace, power plant, and metallurgic industries. Usages include temperature, pressure, torque, strain, gas, liquid, biochemical, and mass sensors in structural health monitoring, industrial process monitoring, environment checking and control, and condition based maintenance. For harsh environment high-temperature applications, battery-free wireless operation associated with sensor robustness, small profile, and mass fabrication capability make SAW sensors a very attractive solution. For high-temperature (< 800°C) gas sensor applications, the stability of SAW sensor platform including protective and sensing film layers must be guaranteed over time and under temperature cycling conditions. This paper reports on the performance and stability of langasite SAW resonator (SAWR) sensor platform using PtAl2O3-based electrode, with atomic layer deposited (ALD) Al2O3 protective layer and yttria-stabilized zirconia (YSZ) gas sensing layer. The effect of 50nm thick Al2O3 or YSZ layers on SAWR sensor resonant frequency and temperature sensitivity responses were investigated. Temperature sensitivities of SAWR sensors with and without ALD Al2O3 protective layer have been compared with numerical predictions for a bare substrate. Measured temperature sensitivities of SAWR sensors with and without the YSZ sensing layers have been compared against each other. In addition, the stability of the SAWR sensor frequency responses have been monitored during multiple 110-hour temperature cycling (over 620 hours in total) from 300°C to 750°C. The measured frequency deviation at 750ºC over six of these 110-hour cycling tests was 0.05%. The results obtained confirm that the presence of the ALD Al2O3 protective layer or the YSZ sensing layer do not compromise the stability of high-temperature harsh environment SAWR sensors, validating their use for the aforementioned applications.

42 ENGINEERING↗