Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Etching mechanism of niobium in coaxial Ar/Cl{sub 2} radio frequency plasma

The understanding of the Ar/Cl{sub 2} plasma etching mechanism is crucial for the desired modification of inner surface of the three dimensional niobium (Nb) superconductive radio frequency cavities. Uniform mass removal in cylindrical shaped structures is a challenging task because the etch rate varies along the direction of gas flow. The study is performed in the asymmetric coaxial radio-frequency (rf) discharge with two identical Nb rings acting as a part of the outer electrode. The dependence of etch rate uniformity on pressure, rf power, dc bias, Cl{sub 2} concentration, diameter of the inner electrode, temperature of the outer cylinder, and position of the samples in the structure is determined. To understand the plasma etching mechanisms, we have studied several factors that have important influence on the etch rate and uniformity, which include the plasma sheath potential, Nb surface temperature, and the gas flow rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deposition of sulfate aerosols with positive Δ 33 S in the Neoarchean

Anomalous sulfur isotope compositions present in Archean rocks have been intensely scrutinized over the last 20 years because they record key aspects of Earth's atmospheric composition prior to the appearance of free molecular oxygen ca. 2.3 billion years ago. These isotopic compositions can be described as mass anomalous fractionations (MAF) and are produced in the atmosphere as UV light interacts with SO 2 molecules. Most interpretations suggest that atmospheric processes generate a reduced S-phase with a positive ( 33 S-enriched) MAF signature, as measured in pyrites, and an oxidized S-phase with a negative anomaly, as measured in bedded barite deposits. However, recent data for carbonate-associated sulfate (CAS) — a direct proxy for the isotopic composition of sulfur from seawater sulfate — in Neoarchean rocks showed no such negative values, but rather the opposite. To understand if the positive MAF anomalies we measured in Neoarchean CAS reflect secondary processes (diagenetic, metamorphic, handling) instead of original signals of Archean seawater sulfate, we collected additional sample suites with various degrees of preservation and metamorphic alteration across the Campbellrand-Malmani platform in South Africa. Results illustrate that within this comprehensive suite, less-altered samples all contain positive MAF values while secondary processes tend to either remove CAS from the sample and/or decrease the 33 S-enrichment. This positive MAF signal in sulfate is therefore reasonably interpreted as a primary depositional origin, and implies that the assumption that sulfate always carries a negative MAF anomaly throughout the Archean rock record needs to be reconsidered. Our CAS observations suggest that future experiments and calculations should also consider atmospheric and/or sulfur cycling processes that can produce oxidized sulfur with a positive MAF signature.

54 ENVIRONMENTAL SCIENCES↗

Secondary Ion Mass Spectroscopy

Secondary Ion mass Spectroscopy (SIMS), as the name suggests, involves characterizing metallic and other materials trough the spectroscopic analysis of secondary ions emanating from the surface of the material to be characterized by the impact of the high energy primary ions. The primary ion source including the choice of its gun, voltage and current can be selected and used depending on the purpose of the analysis. In most instruments more than one primary ion gun is lined up to the sample stage and can be activated with selected accelerating parameters (voltage and beam intensity). The impingement of primary ions on to the sample surface generates positive, negative or neutral ions, electrons, atoms and atomic clusters. Majority of these sample fragments being neutral, could not be utilized as such fragments cannot be manipulated through the use of electromagnetic or electrostatic lenses. Secondary ions that are positively or negatively charged possess large variation in velocity, charge, and mass. These ionic fragments eventually travel through a system of several lenses in very high vacuum to reach detector/counter. Relative amounts of alloying elements or impurities in an alloy can be calculated from the counts of related ions accumulated in the detector/counter.

Panda, Binayak↗

Simulation study of energy resolution, position resolution and $\pi^0$-$\gamma$ separation of a sampling electromagnetic calorimeter at high energies

A simulation study of energy resolution, position resolution, and π(0)-γ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the design geometry of the Shashlik calorimeter which was considered as a candidate for CMS endcap for the phase II of LHC running. The methods proposed in this paper can be easily adapted to various geometrical layouts of a sampling calorimeter. Energy resolution is studied for different layouts and different absorber-scintillator combinations of the Shashlik detector. It is shown that a boosted decision tree using fine grained information of the calorimeter can perform three times better than a cut-based method for separation of π(0) from γ over a large energy range of 20 GeV–200 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

GPS-aided gravimetry at 30 km altitude from a balloon-borne platform

A balloon-borne experiment, flown at 30 km altitude over New Mexico, was used to test dynamic differential Global Positioning System (GPS) tracking in support of gravimetry at high-altitudes. The experiment package contained a gravimeter (Vibrating String Accelerometer), a full complement of inertial instruments, a TI-4100 GPS receiver and a radar transponder. The flight was supported by two GPS receivers on the ground near the flight path. From the 8 hour flight, about a forty minute period was selected for analysis. Differential GPS phase measurements were used to estimate changes in position over the sample time interval, or average velocity. In addition to average velocity, differential positions and numerical averages of acceleration were obtained in three components. Gravitational acceleration was estimated by correcting for accelerations due to translational motion, ignoring all rotational effects.

Lazarewicz, Andrew R.↗

Heating And Positioning In A Microwave Cavity

Two reports describe theoretical and experimental studies of microwave dielectrophoretic positioning of spherical sample of lossy dielectric material in microwave resonant cavity and heating of positioned sphere by electro-magnetic field. Studies part of continuing effort to develop techniques for containerless processing of materials in microgravity. Previous studies in this series described in "Microwave Dielectrophoretic Levitation in Microgravity" (NPO-18824).

Jackson, Henry W.↗

Compact ultrahigh vacuum sample environments for x-ray nanobeam diffraction and imaging

X-ray nanobeams present the opportunity to obtain structural insight in materials with small volumes or nanoscale heterogeneity. The effective spatial resolution of the information derived from nanobeam techniques depends on the stability and precision with which the relative position of the x-ray optics and sample can be controlled. Nanobeam techniques include diffraction, imaging, and coherent scattering, with applications throughout materials science and condensed matter physics. Sample positioning is a significant mechanical challenge for x-ray instrumentation providing vacuum or controlled gas environments at elevated temperatures. Such environments often have masses that are too large for nanopositioners capable of the required positional accuracy of the order of a small fraction of the x-ray spot size. Similarly, the need to place x-ray optics as close as 1 cm to the sample places a constraint on the overall size of the sample environment. We illustrate a solution to the mechanical challenge in which compact ion-pumped ultrahigh vacuum chambers with masses of 1–2 kg are integrated with nanopositioners. The overall size of the environment is sufficiently small to allow their use with zone-plate focusing optics. We describe the design of sample environments for elevated-temperature nanobeam diffraction experiments demonstrate in situ diffraction, reflectivity, and scanning nanobeam imaging of the ripening of Au crystallites on Si substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of pressure-broadened ozone spectra in the 3 micron region

This work involves the analysis of a series of McMath Fourier Transform Infrared (FTIR) spectra of ozone broadened by mixing with air (four different pressures), nitrogen (three pressures), or oxygen (three pressures). Each spectrum covers the region from 2396 to 4057 cm(-1). This study focused on the 3 sub nu sub 3 band in t 3000 to 3060 cm(-1). The band is analyzed by first dividing its region into small intervals containing a few well isolated absorption lines of reasonable intensity. Each of these small intervals is fit by multiple iterations of the nonlinear least squares program until residuals (the difference between calculated and observed spectrum, as a percent of the strongest intensity in the interval) are minimized to a reasonable value which corresponds to the noise level of the measured spectrum. Position, intensity, and half-width are recorded for later analysis. From the measured half-widths, a pressure broadening coefficient was determined for each absorption line. Pressure shifts were determined by comparing observed line positions in the spectra of the diluted ozone samples to tabulated line positions determined from spectra of pure gas samples. Comparisons to other work on ozone indicate that the broadening and shift coefficients determined in this study are consistent with those determined in other spectral regions.

Prochaska, Eleanor S.↗

Anomalous dips in reflection spectra of optical polymers deposited on plasmonic metals

Abstract We have studied reflection spectra of dye-doped and undoped polymers deposited onto Ag and Au substrates and found anomalous dips in the UV spectral range. On top of Ag substrates, the λ ∼ 375 nm dips were observed in undoped PMMA, PVP, and PS polymers as well as PMMA doped with Rh590 and HITC laser dyes. In silver-based samples, the spectral positions of the observed reflection dips were close to singularities in the refractive indexes of surface plasmon polaritons (SPPs) propagating at the interface between Ag and polymer. The latter singularities can tentatively explain the λ ∼ 375 nm reflection dips, if the scattering of Ag and polymeric films is large enough to launch SPP without any prism or grating. The dips observed in reflection of Rh590:PMMA and HITC:PMMA on top of Au, were more pronounced than those on Ag, broader, shifted to shorter wavelengths, and their spectral positions had large standard deviations. Furthermore, no anomalous dips in gold-based samples were observed in the reflection spectra of undoped PMMA, PVP, and PS polymers, and a modest singularity in the SPP refractive index, predicted theoretically at λ ∼ 500 nm, cannot explain the dips in the UV reflection spectra observed experimentally. It appears likely that the origin of the reflection dips on top of Au substrates is different from that on top of Ag substrates.

36 MATERIALS SCIENCE↗

RT-QuIC detection of chronic wasting disease prion in platelet samples of white-tailed deer

Chronic wasting disease (CWD) is a prion disease of captive and free-ranging cervids. Currently, a definitive diagnosis of CWD relies on immunohistochemistry detection of PrP Sc in the obex and retropharyngeal lymph node (RPLN) of the affected cervids. For high-throughput screening of CWD in wild cervids, RPLN samples are tested by ELISA followed by IHC confirmation of positive results. Recently, real-time quacking-induced conversion (RT-QuIC) has been used to detect CWD positivity in various types of samples. To develop a blood RT-QuIC assay suitable for CWD diagnosis, this study evaluated the assay sensitivity and specificity with and without ASR1-based preanalytical enrichment and NaI as the main ionic component in assay buffer. A total of 23 platelet samples derived from CWD-positive deer (ELISA +/IHC +) and 30 platelet samples from CWD-negative (ELISA-) deer were tested. The diagnostic sensitivity was 43.48% (NaCl), 65.22% (NaI), 60.87% (NaCl-ASR1) or 82.61% (NaI-ASR1). The diagnostic specificity was 96.67% (NaCl), 100% (NaI), 100% (NaCl-ASR1), or 96.67% (NaI-ASR1). The probability of detecting CWD prion in platelet samples derived from CWD-positive deer was 0.924 (95% CRI: 0.714, 0.989) under NaI-ASR1 experimental condition and 0.530 (95% CRI: 0.156, 0.890) under NaCl alone condition. The rate of amyloid formation (RFA) was greatest under the NaI-ASR1 condition at 10 -2 (0.01491, 95% CRI: 0.00675, 0.03384) and 10 -3 (0.00629, 95% CRI: 0.00283, 0.01410) sample dilution levels. Incorporation of ASR1-based preanalytical enrichment and NaI as the main ionic component signifcantly improved the sensitivity of CWD RT-QuIC on deer platelet samples. Blood test by the improved RT-QuIC assay may be used for antemortem and postmortem diagnosis of CWD.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Plasmodium falciparum pfhrp2 and pfhrp3 gene deletions and performance of a rapid diagnostic test for identifying asymptomatic malaria infection in northern Ethiopia, 2015

Background: Rapid diagnostic tests (RDTs) are widely used for malaria diagnosis of both symptomatic and asymptomatic infections. Although RDTs are a reliable and practical diagnostic tool, the sensitivity of histidine-rich protein 2 (HRP2)-based RDTs can be reduced if pfhrp2 or pfhrp3 (pfhrp2/3) gene deletions exist in the Plasmodium falciparum parasite population. This study evaluated dried blood spot (DBS) samples collected from a national household survey to investigate the presence of pfhrp2/3 deletions and the performance of the RDT used in the cross-sectional survey in a low transmission setting. Methods: The 2015 Ethiopia Malaria Indicator Survey tested household members by RDT and collected DBS samples. DBS (n = 2648) from three regions in northern Ethiopia were tested by multiplex bead-based antigen detection assay after completion of the survey. The multiplex assay detected pan-Plasmodium lactate dehydrogenase (LDH), pAldolase, and HRP2 antigens in samples. Samples suspected for pfhrp2/3 gene deletions (pLDH and/or pAldolase positive but low or absent HRP2) were further investigated by molecular assays for gene deletions. Antigen results were also compared to each individual’s RDT results. Dose–response logistic regression models were fit to estimate RDT level of detection (LOD) antigen concentrations at which 50, 75, 90, and 95% of the RDTs returned a positive result during this survey. Results: Out of 2,648 samples assayed, 29 were positive for pLDH or pAldolase antigens but low or absent for HRP2 signal, and 15 of these samples (51.7%) were successfully genotyped for pfhrp2/3. Of these 15 P. falciparum infections, eight showed single deletions in pfhrp3, one showed a single pfhrp2 deletion, and six were pfhrp2/3 double-deletions. Six pfhrp2 deletions were observed in Tigray and one in Amhara. Twenty-five were positive for HRP2 by the survey RDT while the more sensitive bead assay detected 30 HRP2-positive samples. A lower concentration of HRP2 antigen generated a positive test result by RDT compared to pLDH (95% LOD: 16.9 ng/mL vs. 319.2 ng/mL, respectively). Conclusions: There is evidence of dual pfhrp2/3 gene deletions in the Tigray and Amhara regions of Ethiopia in 2015. As the prevalence of malaria was very low (< 2%), it is difficult to make strong conclusions on RDT performance, but these results challenge the utility of biomarkers in household surveys in very low transmission settings.

60 APPLIED LIFE SCIENCES↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Equilibrium shape and location of a liquid drop acoustically positioned in a resonant rectangular chamber

The effect of a standing wave field in a rectangular chamber on the shape and location of an acoustically positioned drop or bubble is calculated. The sample deformation and equilibrium position are obtained from an analysis of the spherical harmonic projections of the total surface stress tensor. The method of calculation relies on the assumed condition that the sample is only slightly distorted from a spherical form. The equilibrium location of a levitated drop is combined with a formula introduced by Hasegawa (1979) to calcualte the ka dependence of the radiation force function. The present theory is valid for large as well as small ka values. Calculations in the small ka limit agree with previous theories and experimental results. Examples are presented for nonplane-wave modes as well as plane-wave rectangular modes.

Jackson, H. W.↗

An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creating a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗