Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Future grid mix impacts on whole-building life cycle assessment

Building construction and operation are a significant contribution to global greenhouse gas emissions, so understanding and mitigating emissions is crucial for reliable and realistic emissions accounting. Whole-building Life Cycle Assessment (WBLCA) is an emissions accounting method that considers lifetime environmental impacts of a building during its construction, operation, and eventual end-of-life. When performing WBLCAs, emission calculations from the building's operation over the entire building lifespan are typically based on today's energy grid mixes. This method does not consider changes or advancements in the clean energy proportion within the grid mix and can over or under-inflate results, skewing the ratio of embodied vs. operational environmental impacts. While a variety of prediction tools estimate what future grid emissions might be, predictions can vary widely. To predict the clean energy ratio within future grid mixes and the potential impact these changes might have on WBLCA, annual data from several existing U.S. grid models was averaged and probabilistic modeling was used to extend the usable projections of shorter forecasts. Results show that clean energy sources will likely continue to increase over time, although the rate of growth varies by model. On average, by 2085, the clean energy penetration of the grid is projected to reach ~81% and renewable energy is projected to reach ~71%, although no widespread consensus is reached. To understand how the future grid mix impacts lifetime building emissions within a WBLCA context, the team analyzed two 2021 IECC-compliant all-electric residential buildings: one built from traditional materials and construction processes and the other built with carbon sequestering materials and modular assembly, with a portion of energy generated on site. The results indicate that a moderate estimate of future electricity grid mixes shows a reduction of yearly operational emissions for traditional residential buildings of 55% between 2025 and 2085, and a corresponding reduction of 48% of total emissions over a 60 year building lifespan. This study offers a nuanced approach to account for the variability of future grid mix models and provides an average trend-line based on a robust collection of scenarios.

Life Cycle Assessment (LCA)↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A section 110 evaluation of the 10,500-foot blast line civil effects structures and military trenches associated with the apple-2 test, area 1, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has tasked Desert Research Institute (DRI) with identifying and evaluating additional resources that contribute to the significance of the Apple-2 Historic District as part of a Section 110 effort. Apple-2 was a 1955 atmospheric test in which the Federal Civil Defense Administration (FCDA) conducted an extensive civil effects program named Operation Cue. The objective of Operation Cue was to understand the blast and thermal effects of the test by using a simulated community of residential buildings, industrial structures, utilities, and commercial equipment arranged at various distances from ground zero (GZ). Military operations conducted by the Department of Defense (DoD) as part of the Desert Rock VI exercise were also associated with the Apple-2 test. The Apple-2 Historic District was originally defined in 2000 by Johnson and Edwards as 15 highly visible contributing elements dispersed across the landscape. Since its original recording, DRI has conducted additional archival research and this report details the identification and evaluation results of testing-related material remains at a distance of 10,500 ft from the Apple-2 GZ. Between 2017 and 2020, DRI conducted fieldwork at 10,500 ft from the Apple-2 GZ, revisited previously recorded contributing elements, and identified and evaluated newly recorded resources associated with Operation Cue as well as DoD operations. In total, DRI revisited or newly identified 15 principal resources. Of these, 13 are located within the historic district and contribute to the district’s significance. A set of military trenches and the associated material remains are discontiguous from the district, but also contribute to the district’s significance.

54 ENVIRONMENTAL SCIENCES↗

Decarbonizing the U.S. Economy by 2050: A National Blueprint for the Buildings Sector

Residential and commercial buildings are among the largest sources of carbon dioxide and other greenhouse gas (GHG) emissions in the United States, responsible for more than one-third of total U.S. GHG emissions. There are nearly 130 million existing buildings in the United States, with 40 million new homes and 60 billion square feet of commercial floorspace expected to be constructed between now and 2050. Today, most buildings consume large amounts of energy and cause significant climate pollution to meet our basic needs. Buildings account for 74% of U.S. electricity use and building heating and cooling drives peak electricity demand. Moreover, buildings are where electric vehicles (EVs), solar, storage, heat pumps, water heaters, and other distributed energy resources integrate with the electricity system. Consequently, the buildings sector will play a key role in achieving economywide net-zero emissions by 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

DSO+T: Integrated System Simulation (DSO+T Study: Volume 2)

This report summarizes an integrated co-simulation model used by the Distribution System Operator with Transactive (DSO+T) study to represent an electrical generation, delivery, and end-load systems for the purposes of assessing the viability and value proposition of transactive energy coordination of flexible assets versus a business-as-usual case. The integrated co-simulation model includes the bulk generation and transmission system, including the day-ahead and real-time scheduling and dispatch of thermal generators. Forty distribution system operators were modelled in detail, including tens of thousands of residential and commercial buildings and their flexible end-loads. These included HVAC systems, residential water heaters, electric vehicles, and stationary, behind-the-meter, batteries. Both wholesale market and end-load results for the business-as-usual case are presented and compared to actual ERCOT system data to assess the accuracy and representativeness of the resulting model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Next Generation Integrated PV Products Cost and Workflow Analysis (Final Report)

Residential photovoltaic (PV) costs have fallen consistently for over a decade (Ardani et al. 2018). DOE has subsequently developed a new residential PV cost target for 2030 of $0.05/kilowatt hour (SETO 2023). Ardani et al. (2018) conclude that integrated roofing and PV (RIPV) products may be key to achieving the residential target for both new construction and retrofit residential PV. In RIPV, the PV product is incorporated into or replaces the roofing material. RIPV systems can use conventional crystalline or thin-film technologies, may be aesthetically attractive alternatives to traditional racked and mounted PV systems, and may increase building property values (Cook et al. 2023). These products also have the potential to provide customer acquisition, labor, and equipment cost savings over traditional, racked and mounted residential rooftop PV and several companies have recently introduced integrated roofing and PV (RIPV) products (Cook et al. 2023). In 2022, Tesla was the market leader, representing 94% of RIPV capacity installed in 2022 through its Solar Roof offering, while GAF Energy and its Timberline Solar product was second capturing 3% (Feldman et al. 2023). In this project, NREL analyzed three research questions: (1) How do current RIPV products compare to racked and mounted PV in terms of costs, install times and processes? (2) How are RIPV products installed and are there opportunities for cost savings? (3) What are the key barriers to expanding market opportunities for integrating solar and roofing products? In this project, we explored residential RIPV cost reduction opportunities by analyzing installation processes. Our study documented residential RIPV installations at two reroofing sites (20.52 kilowatts) and the equivalent of nine new construction sites (71.75 kW) in California through a methodology known as time and motion study. We also conducted 15 interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration.

14 SOLAR ENERGY↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection: Preprint

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

BuildStockQuery [SWR-23-58]

BuildStockQuery is a python library designed to simplify and streamline the process of querying massive, terabyte-scale datasets generated by ResStock(TM). ResStock (SWR-19-15) is a U.S. DOE-supported, NREL-built, national residential building energy stock model that enables a new approach to large-scale residential energy analysis across the U.S. by combining large public and private data sources, statistical sampling, detailed sub-hourly building simulations, and high-performance computing. BuildStockQuery offers an intuitive Object-Oriented Programming (OOP) interface to the ResStock output dataset allowing users to easily perform common queries and receive results in familiar pandas DataFrame format, abstracting away the need for complex SQL query. By initializing a query object with the pertinent Athena database and table names, users can easily query for various kinds of insights, for example, timeseries electricity for an end use for a given state grouped by building types.

Adhikari, Rajendra↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Modeling and Analysing the Impact of Heat Pump Water Heaters on Distribution Systems Using GridLAB-D

With the constant increase in energy demand, finding ways to reduce peak load and the energy-costs factors has become more imperative. Domestic water heating showcases a significant opportunity for such applications. Water heating is the second-highest energy consumer in the residential sector across the United States. Electric Water Heaters (EWHs), in particular, constitute nearly 43% of American household water heating energy consumption. Heat Pump Water Heater (HPWH), on the other hand, are an advanced water heating technology that has recently emerged in the United States residential market. The objectives of this work are to develop a HPWH model and build a case study that evaluates various penetration levels of HPWH in providing reduced peak load and cost-effective energy savings for both utilities and customers. The HPWH model was developed and integrated within the GridLAB-D simulation environment. The model behavior was then validated against a real HPWH unit at Portland State University (PSU). The case studies incorporated five HPWH penetration levels, ranging from 20% to 100%. In each case, EWHs were replaced with HPWHs. The results showed that a high penetration level of HPWHs can reduce the energy consumption on a distribution system to 38%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining Power Efficient Residential Electric Appliances and Equipment

While the long-established concept of "energy efficiency" has successfully reduced energy consumption and bills in homes, it is no longer sufficient to address the modern challenges of electrical load growth, infrastructure upgrades and associated affordability challenges. We introduce the concept of “power efficiency” for household appliances and equipment, providing a framework to support affordable home modernization and grid management. Energy efficiency is the measure of energy used (kWh) to provide comfort/conveniences, power efficiency is the measure of power used (kW) to provide those same comforts/conveniences. Energy efficiency was needed because energy is a limited resource and expensive. Now power efficiency is needed because power delivery into a building is a limited resource and expensive. We propose a new set of metrics for defining and measuring power efficiency by investigating how current appliance nameplate ratings are established, and assessing the availability and use of existing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground Source Heat Pump Screening Tool and Related Resources

This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.

15 GEOTHERMAL ENERGY↗