Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the electron-ion collider

We analyze beam-induced depolarizing effects in the hydrogen jet target (HJET) at the relativistic heavy ion collider (RHIC), which has been used for absolute hadron beam polarimetry and shall be employed at the electron-ion collider (EIC). The EIC’s higher bunch repetition frequencies and shorter bunch durations shift beam harmonics to frequencies that can resonantly drive hyperfine transitions in hydrogen, threatening to depolarize the target atoms. Using frequency-domain analysis of beam harmonics and hyperfine transition frequencies, we establish a photon emission threshold above which beam-induced fields are too weak to cause significant depolarization. For EIC injection (23.5 GeV) and flattop (275 GeV), beam-induced depolarization through the bunch structure renders operation at the current RHIC magnetic guide field at the target (𝐵 0 =120⁢ mT) untenable. Increasing the magnetic guide field at the target to 𝐵 0 ≈ 400⁢ mT moves all hyperfine transition frequencies to at least 3 times the cutoff frequency, ensuring reliable absolute beam polarimetry with the required 1% precision at the EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ExaSGD: 2022 Kernel Thrust Activities

The Kernel Thrust milestone ADSE22-407 covers the development of device-capable optimization algorithms and solvers technologies required by the ExaSGD project’s software stack in order to solve security-constrained alternating current optimal power flow (SC-ACOPF) problems on emerging exascale architectures. To this extent, in FY22 the main objective of the Kernel Thrust was (i) provide sparse optimization solver that runs efficiently on hardware accelerator devices (i.e., NVIDIA and AMD GPUs) to perform intra-node computations, (ii) strengthen the reliability and increase the performance of the mixed-dense sparse (MDS) solver of HiOp for deployment on the FY22 target architectures, Summit and Crusher, and (iii) increase performance by improving the mathematical algorithm and refining the parallel MPI-based implementation of the coarse-grain parallel solver HiOp-PriDec for capabilities deployment on the FY22 target architectures, Summit and Crusher. This document presents the developments and contributions done by the Kernels Thrust Team in FY22 toward completion of the above-mentioned objectives. These contributions progressed along four main development (sub)thrusts: (1) Design and implementation of a sparse optimization solver for use on hardware accelerators; (2) Improvement of the mathematical algorithm and of the parallel implementation of HiOp-PriDec to ensure readiness and efficient coarse-grain parallelism for FY23 target exascale machine; and (3) Support Software and Application Development Thrusts of the exaSGD project in their deployment of the project’s software stack on AMD- and NVIDIA-based architectures. The development of the sparse optimization solver (thrust 1 above) was new in FY22 and resulted in a new sparse solver in HiOp (available as of version 0.6). The second development thrust was a continuation of the efforts from FY21 and improved the mathematical algorithm and the communication strategy of the HiOp-PriDec solver. The last developement thrust is a large collaborative effort. Namely, the project’s teams from multiple labs (LLNL, PNNL, ORNL, and NREL) performed large-scale demonstration of the ExaSGD software stack, namely the optimization solvers of HiOp interfaced with the modeling front-end ExaGO and the stochastic sampler PowerScenarios. These demonstration efforts solved large-scale instances of the SC-ACOPF challenge problem of medium network sizes (10, 000-bus system) and large number of contingencies on Summit (NVIDIA accelerators) and Crusher (AMD accelerators) systems at ORNL.

97 MATHEMATICS AND COMPUTING↗

Unraveling the Noise: An Investigation Plan for Signal Interference in Hearing Aids

Bluetooth Low Energy (BLE) has revolutionized the performance of hearing aids with functionalities like seamless audio streaming and enhanced auditory functions. However, BLE operates within the highly congested 2.4 GHz frequency band, making it susceptible to signal interference that can degrade performance, reduce audio quality, and impact user experience. This paper documents interference patterns in BLE communication and introduces practical mitigation techniques aimed at improving the reliability of hearing aids. Attack vectors associated with Bluetooth enabled hearing aids include communication jamming, the interception of data between target devices, and GATT handle exploitation. Attackers could also use the vulnerabilities to block communications or intercept sensitive audio streams, posing significant security and privacy risks. These threats compromise two critical components of the CIA triad: (1) availability, by causing persistent connectivity issues, and (2) integrity, by enabling unauthorized data modifications. It is necessary to deal with these problems to ensure hearing aids work well and safely. This study investigates the impact of BLE signal interference on hearing aids, using tools such as HackRF [1], a Python tool to simulate interference scenarios, and Ubertooth [2] to sniff Bluetooth traffic between hearing aids and the device with the application. This paper investigates testing of BLE traffic in search of specific interference patterns that would impact the functionality of hearing aids, including jamming and flooding. This research focuses on developing robust mitigation techniques with the aim of securing BLE-enabled hearing aids against those vulnerabilities.

Baldwin, David [Savannah River National Laboratory↗

High Spatial Resolution Commercial Satellite Imaging Product Characterization

NASA Stennis Space Center's Remote Sensing group has been characterizing privately owned high spatial resolution multispectral imaging systems, such as IKONOS, QuickBird, and OrbView-3. Natural and man made targets were used for spatial resolution, radiometric, and geopositional characterizations. Higher spatial resolution also presents significant adjacency effects for accurate reliable radiometry.

Ryan, Robert E.↗

Targeting Ballistic Lunar Capture Trajectories Using Periodic Orbits in the Sun-Earth CRTBP

A particular periodic orbit in the Earth-Sun circular restricted three body problem is shown to have the characteristics needed for a ballistic lunar capture transfer. An injection from a circular parking orbit into the periodic orbit serves as an initial guess for a targeting algorithm. By targeting appropriate parameters incrementally in increasingly complicated force models and using precise derivatives calculated from the state transition matrix, a reliable algorithm is produced. Ballistic lunar capture trajectories in restricted four body systems are shown to be able to be produced in a systematic way.

Cooley, D.S.↗

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

Improved Targeting Through Collaborative Decision-Making and Brain Computer Interfaces

This paper reports a first step toward a brain-computer interface (BCI) for collaborative targeting. Specifically, we explore, from a broad perspective, how the collaboration of a group of people can increase the performance on a simple target identification task. To this end, we requested a group of people to identify the location and color of a sequence of targets appearing on the screen and measured the time and accuracy of the response. The individual results are compared to a collective identification result determined by simple majority voting, with random choice in case of drawn. The results are promising, as the identification becomes significantly more reliable even with this simple voting and a small number of people (either odd or even number) involved in the decision. In addition, the paper briefly analyzes the role of brain-computer interfaces in collaborative targeting, extending the targeting task by using a BCI instead of a mechanical response.

Brain computer interfaces (BCI)↗

FPGA Sequencer for Radar Altimeter Applications

A sequencer for a radar altimeter provides accurate attitude information for a reliable soft landing of the Mars Science Laboratory (MSL). This is a field-programmable- gate-array (FPGA)-only implementation. A table loaded externally into the FPGA controls timing, processing, and decision structures. Radar is memory-less and does not use previous acquisitions to assist in the current acquisition. All cycles complete in exactly 50 milliseconds, regardless of range or whether a target was found. A RAM (random access memory) within the FPGA holds instructions for up to 15 sets. For each set, timing is run, echoes are processed, and a comparison is made. If a target is seen, more detailed processing is run on that set. If no target is seen, the next set is tried. When all sets have been run, the FPGA terminates and waits for the next 50-millisecond event. This setup simplifies testing and improves reliability. A single vertex chip does the work of an entire assembly. Output products require minor processing to become range and velocity. This technology is the heart of the Terminal Descent Sensor, which is an integral part of the Entry Decent and Landing system for MSL. In addition, it is a strong candidate for manned landings on Mars or the Moon.

Berkun, Andrew C.↗

Assessment of the frequency and nature of erroneous x-ray photoelectron spectroscopy analyses in the scientific literature

Here, this study was undertaken to understand the extent and nature of problems in x-ray photoelectron spectroscopy (XPS) data reported in the literature. It first presents an assessment of the XPS data in three high-quality journals over a six-month period. This analysis of 409 publications showing XPS spectra provides insight into how XPS is being used, identifies the common mistakes or errors in XPS analysis, and reveals which elements are most commonly analyzed. More than 65% of the 409 papers showed fitting of XP spectra. An ad hoc group (herein identified as “the committee”) of experienced XPS analysts reviewed these spectra and found that peak fitting was a common source of significant errors. The papers were ranked based on the perceived seriousness of the errors, which ranged from minor to major. Major errors, which, in the opinion of the ad hoc committee, can render the interpretation of the data meaningless, occurred when fitting protocols ignored underlying physics and chemistry or contained major errors in the analysis. Consistent with other materials analysis data, ca. 30% of the XPS data or analysis was identified as having major errors. Out of the publications with fitted spectra, ca. 40% had major errors. The most common elements analyzed by XPS in the papers sampled and researched at an online database, include carbon, oxygen, nitrogen, sulfur, and titanium. A scrutiny of the papers showing carbon and oxygen XPS spectra revealed the classes of materials being studied and the extent of problems in these analyses. As might be expected, C 1s and O 1s analyses are most often performed on sp2-type materials and inorganic oxides, respectively. These findings have helped focus a series of XPS guides and tutorials that deal with common analysis issues. The extent of problematic data is larger than the authors had expected. Quantification of the problem, examination of some of the common problem areas, and the development of targeted guides and tutorials may provide both the motivation and resources that enable the community to improve the overall quality and reliability of XPS analysis reported in the literature.

Major, George H.↗

High Temperature Gas Sensor for Coal Combustion System

Robust gas sensors that offer real-time feedback about combustion in coal-fired power plants promise greater energy efficiency with fewer harmful emissions while also improving the bottom line for power generators. Currently, no technology meets this objective. Therefore, the objectives of this project are to develop an accurate, robust, reliable, high temperature sensor offering near real-time feedback to plant operators using a novel catalytic/non-catalytic sensor design to detect target gases available for oxidization. Such a sensor would inform power plant operators how to adjust the amount of fuel and air for an optimal performance.

01 COAL, LIGNITE, AND PEAT↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Computer vision for robots; Proceedings of the Meeting, Cannes, France, December 2-6, 1985

The conference presents papers on segmentation techniques, three-dimensional recognition and representation, processing image sequences, and navigation and mobility. Particular attention is given to determining the pose of an object, adaptive least squares correlation with geometrical constraints, and the reliable formation of feature vectors for two-dimensional shape representation. Other topics include the real-time tracking of a target moving on a natural textured background, computer vision for the guidance of roving robots, and integrating sensory data for object recognition tasks.

Faugeras, O. D.↗

Image based tracking approaches to AR/C at the Johnson Space Center

Automated Rendezvous and Capture (AR&C) requires the determination of the six degrees of freedom relating two free bodies. Sensor systems that can provide such information have varying sizes, weights, power requirements, complexities and accuracies. One type of sensor system which can provide several key advantages is an image based tracking system, or better known as a machine vision system. By image based tracking we mean that the sensor is some imaging device such as one or more video cameras, from which the tracking parameters necessary to support the rendezvous and capture operations (range, attitude, etc.) can be derived. Image based tracking offers many advantages such as relative hardware simplicity and reprogrammability. These advantages must be weighed against the disadvantages of these systems, such as limited operational range, poorer accuracy at greater distances and sensitivity to lighting conditions. However, with properly designed algorithms and targets these disadvantages can be minimized for many important applications. Rigorous testing in realistic environments can further increase the robustness and reliability of these systems. This presentation describes the facilities used at JSC to support AR&C image based tracking development and the details of our binocular stereo approach to image based tracking.

Fisher, Timothy E.↗

Feasibility Testing of Silver Electrolysis for Disinfection of Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. A proof-of-concept prototype of a silver electrolysis reactor was developed, and feasibility was demonstrated for imparting a target silver concentration into a spacecraft water system. Prototype testing showed that the primary initial concerns related to the technology - inefficiencies of electrolysis in low conductivity water, the potential formation of resistive oxides on the electrode surfaces, and the potential for release of electrolytically-generated silver particles to the effluent water - were not problematic over the duration of the feasibility testing. The testing also demonstrated advantages of the technology, including the ability to consistently deliver silver at targeted concentrations and the ability to directly correlate the silver concentration to measurements of water conductivity. On the other hand, the reliability of the system has not yet been demonstrated. During prototype testing, intermittent periods of poor reactor performance manifested as a decrease in voltage accompanied by a decrease in silver output. It was determined that the cause of this behavior was silver-based deposits on inter-electrode wetted surfaces forming a conductive “bridge” between electrodes. Ongoing testing and refinement of the prototype reactor design seek to elucidate the root cause the bridging phenomenon and identify associated mitigation strategies. Once resolved, long-term performance testing is planned as part of continued development of the electrolytic silver dosing system.

Silver↗

Integrated Traction Drive Thermal Management: Keystone Project 3

The presentation represents a report of accomplishments during FY 2022 and is prepared for 2022 DOE VTO Annual Merit Review. The project goal is facilitation of achieving DOE 2025 target of 33 kW/L system power density for an electric traction drive through support of other EDT consortium members in design and development of thermal management systems for their respective integrated drive concepts. Namely, identifying pathways enabling high-performance, compact, and reliable integrated electric drives. Specific objectives are: 1) Research and evaluation of motor-integrated power electronics packaging technologies and thermal management approaches. 2) Development of thermal management system and its sub-components to enable integrated electric drive DOE power density targets in collaboration with project partners. 3) Supporting activities of DOE's Electric Drive Technologies (EDT) consortium members, Oak Ridge National Laboratory (ORNL) and University of Wisconsin research teams in thermal management component design and thermal modeling of their integrated traction drives. 4) Identifying candidate driveline fluids suitable for direct cooling of traction-drive components and high-voltage power electronics and evaluate their convective cooling performance.

ADVANCED PROPULSION SYSTEMS↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗