Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

Formation and propagation of laser-driven plasma jets in an ambient medium studied with X-ray radiography and optical diagnostics

In this paper, we present experimental results obtained on the LULI2000 laser facility regarding structure and dynamics of astrophysical jets propagating in interstellar medium. The jets, generated by using a cone-shaped target, propagate in a nitrogen gas that mimics the interstellar medium. X-ray radiography as well as optical diagnostics were used to probe both high and low density regions. In this paper, we show how collimation of the jets evolves with the gas density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

42 ENGINEERING↗

Study of self-generated fields in strongly-shocked, low-density systems using broadband proton radiography

Here we report results from experiments on the study of field generation at the shock front in low-density gas configured in quasi-planar geometry using broad-energy proton probing. Experiments were conducted using three long pulse laser beams with a total energy of 6.4 kJ in 2 ns for shock generation and an 850 J, 10 ps short pulse laser to produce broadband protons for radiography. Observations of the deflection pattern of probe protons show the existence of self-generated electric fields at the shock front with the electric potential on the order of 300 V. Finally, analytical and particle tracking methods support this conclusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 μm, close to theoretical predictions. Results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

47 OTHER INSTRUMENTATION↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Simultaneous compression and opacity data from time-series radiography with a Lagrangian marker

Time-resolved radiography can be used to obtain absolute shock Hugoniot states by simultaneously measuring at least two mechanical parameters of the shock, and this technique is particularly suitable for one-dimensional converging shocks where a single experiment probes a range of pressures as the converging shock strengthens. However, at sufficiently high pressures, the shocked material becomes hot enough that the x-ray opacity falls significantly. Additionally, if the system includes a Lagrangian marker such that the mass within the marker is known, this additional information can be used to constrain the opacity as well as the Hugoniot state. In the limit that the opacity changes only on shock heating, and not significantly on subsequent isentropic compression, the opacity of the shocked material can be determined uniquely. More generally, it is necessary to assume the form of the variation of opacity with isentropic compression or to introduce multiple marker layers. Alternatively, assuming either the equation of state or the opacity, the presence of a marker layer in such experiments enables the non-assumed property to be deduced more accurately than from the radiographic density reconstruction alone. An example analysis is shown for measurements of a converging shock wave in polystyrene at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the evolution of liquid and solid microjets from grooved Sn and Cu samples using radiography

Experiments were performed on grooved Sn and Cu samples to study the temporal evolution of microjets. Jets were generated by the impact of gun-launched flyer plates against the back of grooved targets made from either Cu or Sn (groove depth of ~250 μm). The Hugoniot states in the various Sn targets encompassed conditions where solid phases are maintained throughout (7 and 16 GPa) and also conditions where melting occurs upon the release of compression (25 and 34 GPa); the transition occurs near a Hugoniot pressure of 23 GPa. Cu targets at 27 and 56 GPa provide comparisons in which the jets move at similar speeds but remain solid. In all cases, the spatial distribution of mass within the microjets was measured using high-speed synchrotron radiography. The result is a time history of the jet thickness profile from which quantities like total jet mass and jet velocity can be derived. In both the solid and liquid states, we generally observe that an increase in the shock strength leads to an increase in jet mass. However, this trend breaks down for Hugoniot states near the transition from continuously solid to melted-on-release. This is evidenced by the observation that there was no difference in the rate of mass flow in Sn jets at 16 and 25 GPa, while similar pressure jumps on either side of this range caused substantial changes in the jet mass. This contrasts with the behavior of smaller polishing defects that were present on the same samples (~1 μm deep). From these, no ejecta mass was detected below the melt boundary, but obvious microjets were generated once melting occurred. This indicates that crossing the bulk melt-on-release threshold can alternately promote or inhibit the flow of mass into microjets based on the amplitude of the initial perturbation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnosing magnetic fields in cylindrical implosions with oblique proton radiography

Two experiments at the OMEGA Laser System used oblique proton radiography to measure magnetic fields in cylindrical implosions with and without an applied axial magnetic field. Although the goal of both experiments was to measure the magnitude of the compressed axial magnetic field in the core of the implosion, this field was obfuscated by two features in the coronal plasma produced by the compression beams: an azimuthal self-generated magnetic field and small length scale, high-amplitude structures attributed to collisionless effects. In order to understand these features, synthetic radiographs are generated using fields produced by 3D HYDRA simulations. These synthetic radiographs reproduce the features of the experimental radiographs with the exception of the small-scale structures. A direct inversion algorithm is successfully applied to a synthetic radiograph but is only partially able to invert the experimental radiographs in part because some protons are blocked by the field coils. The origins of the radiograph features and their dependence on various experimental parameters are explored. Furthermore, the results of this analysis should inform future measurements of compressed axial magnetic fields in cylindrical implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flash x-ray radiography analysis of detonation wave propagation in additive-manufactured high explosives

Recent research has demonstrated that additive manufacturing (AM) can be used to produce directionally sensitive high explosives (HEs), but detonation wave propagation in AM HEs with variable internal structure has not been studied. In this work, samples were printed using a 73 wt. % octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine-based HE ink. Flash x-ray radiography imaging was used to observe density changes in two imaging planes of each sample during detonation, and high-speed imaging was used to calculate the detonation velocity at the HE surface. The detonation front initially appears to fail in internal channel regions of the HE, but late reactions occurred in two samples, which increased the material bulk density by 2.8%, possibly due to shock convergence phenomena. The calculated detonation wave pressure similarly increased, but the accuracy of the results is uncertain because of the deviation of the low bulk density printed samples from the cast charge principal isentrope. Here, this work demonstrates that structure can be effectively utilized to guide detonation wave propagation through HE charges.

3D printing↗

Investigation of boosted proton energies through proton radiography of target normal sheath acceleration fields in the multi-ps regime

Multi-kilojoule, multi-picosecond short-pulse lasers, such as the National Ignition Facility-Advanced Radiographic Capability laser and the OMEGA-Extended Performance laser, which have been constructed over the last two decades, enable exciting opportunities to produce high-brightness, high-energy laser-driven proton sources for applications in high-energy-density science like proton fast ignition for inertial fusion energy, particle radiography, and materials science studies. Results on these platforms have demonstrated enhanced accelerated proton energies and electron temperatures when compared to established scaling laws. Recent work has developed a new scaling for proton TNSA in the multi-ps regime. However, this new physics in the multi-ps regime motivates the need to understand the origin of the enhancement in proton energies. Toward this goal, here this work presents the first measurements of the TNSA accelerating sheath field in the multi-ps regime for pulse durations of 0.6, 5, and 10 ps. This measurement was achieved by using a separate TNSA proton source to radiograph the spatiotemporal profile of the accelerating sheath that is responsible for proton acceleration. The use of stacked radiochromic film detectors allows for a discrete time profile of the radiographs, thus enabling the measurement of the temporal and spatial evolution of the accelerating field. In performing this measurement, we extract quantities such as the sheath strength as a function of time and pulse duration, which shows that longer pulse durations sustain a stronger electric field for a longer duration when compared to sub-ps laser pulses, which may enable the observed boosted proton energies and proton conversion efficiencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using deep machine learning to interpret proton radiography data from a pulsed power experiment

Deep machine learning is used to analyze a proton radiograph from a tin pulsed power experiment and determine density values for each pixel in the image. Two promising convolutional neural network architectures that have proven to be effective for image analysis in other applications are applied to analyze a proton radiograph and find density values. The process of creating a suitable training dataset is described, involving the Lagrangian hydrodynamic model used for simulations of the experiment, the proton radiography forward model to make synthetic images for training, and the manner in which data augmentation is used to expand the resulting image dataset. It is shown that machine learning not only produces a reasonable density field but is also able to predict features in the density field that are suggested by the proton radiograph but not captured by simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Areal density and spatial resolution of high energy electron radiography

Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density (HED) matter. In this work, we designed a high energy electron radiography (HEER) system based on a linear electron accelerator to evaluate its capability for imaging HED matter. 40 MeV electron beams were used to image an aluminum target to study the density resolution and spatial resolution of HEER. The results demonstrate a spatial resolution of tens of micrometers. The interaction of the beams with the target and the beam transport of the transmitted electrons are further simulated with EGS5 and PARMELA codes, with the results showing good agreement with the experimental resolution. Furthermore, the experiment can be improved by adding an aperture at the Fourier plane.

areal density resolution↗