Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REAGENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Observation Platform for Dynamic Biomedical and Biotechnology Experiments Using the International Space Station (ISS) Light Microscopy Module (LMM)

Techshot, Inc., has developed an observation platform for the LMM on the ISS that will enable biomedical and biotechnology experiments. The LMM Dynamic Stage consists of an electronics module and the first two of a planned suite of experiment modules. Specimens and reagent solutions can be injected into a small, hollow microscope slide-the heart of the innovation-via a combination of small reservoirs, pumps, and valves. A life science experiment module allows investigators to load up to two different fluids for on-orbit, real-time image cytometry. Fluids can be changed to initiate a process, fix biological samples, or retrieve suspended cells. A colloid science experiment module conducts microparticle and nanoparticle tests for investigation of colloid self-assembly phenomena. This module includes a hollow glass slide and heating elements for the creation of a thermal gradient from one end of the slide to the other. The electronics module supports both experiment modules and contains a unique illuminator/condenser for bright and dark field and phase contrast illumination, power supplies for two piezoelectric pumps, and controller boards for pumps and valves. This observation platform safely contains internal fluids and will greatly accelerate the research and development (R&D) cycle of numerous experiments, products, and services aboard the ISS.

Kurk, Michael A. (Andy)↗

Observation Platform for Dynamic Biomedical and Biotechnology Experiments Using the International Space Station (ISS) Light Microscopy Module (LMM)

Techshot, Inc., has developed an observation platform for the LMM on the ISS that will enable biomedical and biotechnology experiments. The LMM Dynamic Stage consists of an electronics module and the first two of a planned suite of experiment modules. Specimens and reagent solutions can be injected into a small, hollow microscope slide-the heart of the innovation-via a combination of small reservoirs, pumps, and valves. A life science experiment module allows investigators to load up to two different fluids for on-orbit, real-time image cytometry. Fluids can be changed to initiate a process, fix biological samples, or retrieve suspended cells. A colloid science experiment module conducts microparticle and nanoparticle tests for investigation of colloid self-assembly phenomena. This module includes a hollow glass slide and heating elements for the creation of a thermal gradient from one end of the slide to the other. The electronics module supports both experiment modules and contains a unique illuminator/condenser for bright and dark field and phase contrast illumination, power supplies for two piezoelectric pumps, and controller boards for pumps and valves. This observation platform safely contains internal fluids and will greatly accelerate the research and development (R&D) cycle of numerous experiments, products, and services aboard the ISS.

Kurk, Michael A. (Andy)↗

Preparation of Metal Nanowire Decorated Carbon Allotropes

In the method of embodiments of the invention, the metal seeded carbon allotropes are reacted in solution forming zero valent metallic nanowires at the seeded sites. A polymeric passivating reagent, which selects for anisotropic growth is also used in the reaction to facilitate nanowire formation. The resulting structure resembles a porcupine, where carbon allotropes have metallic wires of nanometer dimensions that emanate from the seed sites on the carbon allotrope. These sites are populated by nanowires having approximately the same diameter as the starting nanoparticle diameter.

Southward, Robin E.↗

Things That Scientists Don't Understand About NASA Spaceflight Research

So you want to conduct human spaceflight research aboard the International Space Station (ISS)? Once your spaceflight research aboard the ISS is proposal is funded.... the real work begins. Because resources are so limited for ISS research, it is necessary to maximize the work being done, while at the same time, minimizing the resources spent. Astronauts may be presented with over 30 human research experiments and select, on average approximately 15 in which to participate. In order to conduct this many studies, ISSMP uses the study requirements provided by the principle investigator to integrate all of this work into the astronauts' complement. The most important thing for investigators to convey to the ISSMP team is their RESEARCH REQUIREMENTS. Requirements are captured in the Experiment document. This document is the official record of how, what, where and when data will be collected. One common mistake that investigators make is not taking this document seriously, but when push comes to shove, if a research requirement is not in this document....it will not get done. The research requirements are then integrated to form a complement of research for each astronaut. What do we mean by integration? Many experiments have overlapping requirements; blood draws, behavioral surveys, heart rate measurement. Where possible, these measures are combined to reduce redundancy and save crew time. Investigators can access these data via data sharing agreements. More examples of how ISS research is integrated will be presented. There are additional limitations commonly associated with human spaceflight research that will also be discussed. Large/heavy hardware, invasive procedures, and toxic reagents are extremely difficult to implement on the ISS. There are strict limits placed on the amount of blood that can be drawn from crew members during (and immediately after) spaceflight. These limits are based on 30-day rolling accumulations. We have recently had to start restricting studies due to this limit. The NASA Human Research Program (HRP) provides extensive support, via ISSMP, to help investigators cope with all of the intricacies of conducting human spaceflight research. This presentation will help you take the best advantage of that support.

Platts, S. H.↗

Evaluation of Volatile Species in Green Monopropellant Project

NASA is interested in green monopropellants to replace hydrazine in reaction control systems (RCSs). Some current NASA programs require reduced vapor pressure and low toxicity monopropellant (green) and superior performance (specific impulse and density) formulations. Earlier vapor phase studies of a candidate green monopropellant at the NASA White Sands Test Facility (WSTF) showed the presence of a volatile species that warranted further investigation. The purpose of this study was to further characterize the volatile species and to evaluate it. The evaluation was with respect to whether the volatile species was an impurity or how it is formed, and to use that information to examine whether its presence as an impurity can be eliminated during formulation. The evaluation also considered whether formation of the volatile impurity could be prevented while not compromising the propellant. To reduce variables associated with evaluation of the propellant formulation as a whole, a precursor to one of the individual components in the propellant formulation was subjected to a NASA Standard 6001B Flammability, Off-gassing, and Compatibility Requirements and Test Procedures "Determination of Off-gassed Products (Test 7)". Testing took place in the NASA WSTF Molecular Desorption and Analysis Laboratory. One gram of the precursor was placed in a flask within a specimen container. After thermal conditioning for 72 +/- 1 h at 50 +/- 3 deg C (122 +/- 5 deg F), the atmosphere inside the specimen container was analyzed for off-gassed compounds by cryotrap gas chromatography-mass spectrometry (GC-MS) and fixed sample loop GC-flame ionization detection (GC-FID). The specimen container used was glass to minimize potential catalytic surfaces. The identification of compounds was difficult due to the complexity of the vapor phase concentrations and overlapping chromatographic peaks and mass spectra. However, eleven compounds were specifically identified and five compounds or classes of compounds were reported as unidentified. Quantitation of most of the compounds, including unidentified compounds, was as methane. Quantitating compounds or classes of compounds that were detected but for which specific calibration is not established as methane is in accordance with the Test 7 standard protocol. The thermal decomposition temperature of the precursor was significantly higher than the test temperature. Based on thermal decomposition temperature and on an examination of the structure and chemistry of the identified volatile species, the presence of the volatile species appears to be chemically reasonable with respect to the propellant formulation and is at this time attributed to impurities. Further examination of the overall propellant formulation process (including the individual components' synthesis processes) and process quality control (including purity of reagents and possible decomposition reactions) is indicated.

Greene, Benjamin↗

On-Orbit Quantitative Real-Time Gene Expression Analysis Using the Wetlab-2 System

NASA Ames Research Center's WetLab-2 Project enables on-orbit quantitative Reverse Transcriptase PCR (qRT-PCR) analysis without the need for sample return. The WetLab-2 system is capable of processing sample types ranging from microbial cultures to animal tissues dissected on-orbit. The project developed a RNA preparation module that can lyse cells and extract RNA of sufficient quality and quantity for use as templates in qRT-PCR reactions. Our protocol has the advantage of using non-toxic chemicals and does not require alcohols or other organics. The resulting RNA is dispensed into reaction tubes that contain all lyophilized reagents needed to perform qRT-PCR reactions. System operations require simple and limited crew actions including syringe pushes, valve turns and pipette dispenses. The project selected the Cepheid SmartCycler (TradeMark), a Commercial-Off-The-Shelf (COTS) qRT-PCR unit, because of its advantages including rugged modular design, low power consumption, rapid thermal ramp times and four-color multiplex detection. Single tube multiplex assays can be used to normalize for RNA concentration and integrity, and to study multiple genes of interest in each module. The WetLab-2 system can downlink data from the ISS to the ground after a completed run and uplink new thermal cycling programs. The ability to conduct qRT-PCR and generate results on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. Specifically, the ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. On orbit gene expression analysis can also eliminate the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of fixed samples and provide on-orbit gene expression benchmarking prior to sample return. Finally, the system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental pathogens and crew health. The validation flight of the WetLab-2 system using E. coli bacteria and mouse liver launched on SpaceX-7 in June 2015 and will remain on the ISS National Laboratory.

ISS tools↗

WetLab-2: Providing Quantitative PCR Capabilities on ISS

The objective of NASA Ames Research Centers WetLab-2 Project is to place on the ISS a system capable of conducting gene expression analysis via quantitative real-time PCR (qRT-PCR) of biological specimens sampled or cultured on orbit. The WetLab-2 system is capable of processing sample types ranging from microbial cultures to animal tissues dissected on-orbit. The project has developed a RNA preparation module that can lyse cells and extract RNA of sufficient quality and quantity for use as templates in qRT-PCR reactions. Our protocol has the advantage that it uses non-toxic chemicals, alcohols or other organics. The resulting RNA is transferred into a pipette and then dispensed into reaction tubes that contain all lyophilized reagents needed to perform qRT-PCR reactions. These reaction tubes are mounted on rotors to centrifuge the liquid to the reaction window of the tube using a cordless drill. System operations require simple and limited crew actions including syringe pushes, valve turns and pipette dispenses. The resulting process takes less than 30 min to have tubes ready for loading into the qRT-PCR unit.The project has selected a Commercial-Off-The-Shelf (COTS) qRT-PCR unit, the Cepheid SmartCycler, that will fly in its COTS configuration. The SmartCycler has a number of advantages including modular design (16 independent PCR modules), low power consumption, rapid thermal ramp times and four-color detection. The ability to detect up to four fluorescent channels will enable multiplex assays that can be used to normalize for RNA concentration and integrity, and to study multiple genes of interest in each module. The WetLab-2 system will have the capability to downlink data from the ISS to the ground after a completed run and to uplink new programs. The ability to conduct qRT-PCR on-orbit eliminates the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of fixed samples. The system can be used to validate terrestrial analyses of samples returned from ISS by providing on-orbit gene expression benchmarking prior to sample return. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time for subsequent trials, without the need for sample return and re-flight to sample multigenerational changes. The system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental contaminants and crew health. The verification flight of the instrument is scheduled to launch on SpaceX-7 in June 2015. The WetLab-2 Project is supported by NASAs ISS Program at JSC, Code OZ.

ISS tools↗

Microbial Monitoring from the Frontlines to Space: Department of Defense Small Business Innovation Research Technology Aboard the International Space Station

The RAZOR (trademark) EX, a quantitative Polymerase Chain Reaction (qPCR) instrument, is a portable, ruggedized unit that was designed for the Department of Defense (DoD) with its reagent chemistries traceable to a Small Business Innovation Research (SBIR) contract beginning in 2002. The PCR instrument's primary function post 9/11 was to enable frontline soldiers and first responders to detect biological threat agents and bioterrorism activities in remote locations to include field environments. With its success for DoD, the instrument has also been employed by other governmental agencies including Department of Homeland Security (DHS). The RAZOR (Trademark) EX underwent stringent testing by the vendor, as well as through the DoD, and was certified in 2005. In addition, the RAZOR (trademark) EX passed DHS security sponsored Stakeholder Panel on Agent Detection Assays (SPADA) rigorous evaluation in 2011. The identification and quantitation of microbial pathogens is necessary both on the ground as well as during spaceflight to maintain the health of astronauts and to prevent biofouling of equipment. Currently, culture-based monitoring technology has been adequate for short-term spaceflight missions but may not be robust enough to meet the requirements for long-duration missions. During a NASA-sponsored workshop in 2011, it was determined that the more traditional culture-based method should be replaced or supplemented with more robust technologies. NASA scientists began investigating innovative molecular technologies for future space exploration and as a result, PCR was recommended. Shortly after, NASA sponsored market research in 2012 to identify and review current, commercial, cutting edge PCR technologies for potential applicability to spaceflight operations. Scientists identified and extensively evaluated three candidate technologies with the potential to function in microgravity. After a thorough voice-of-the-customer trade study and extensive functional and safety evaluations, the RAZOR (trademark) EX PCR instrument(Bio-Fire Defense, Salt Lake City, UT) was selected as the most promising current technology for spaceflight monitoring applications.

Cherie M Oubre↗

Increasing Efficiency of Fecal Coliform Testing Through EPA-Approved Alternate Method Colilert*-18

The 21 SM 9221 E multiple-tube fermentation method for fecal coliform analysis requires a large time and reagent investment for the performing laboratory. In late 2010, the EPA approved an alternative procedure for the determination of fecal coliforms designated as Colilert*-18. However, as of late 2016, only two VELAP-certified laboratories in the Commonwealth of Virginia have been certified in this method.

Cornwell, Brian↗

Controlled Nitric Oxide Production via O(1D) + N2O Reactions for Use in Oxidation Flow Reactor Studies

Oxidation flow reactors that use low-pressure mercury lamps to produce hydroxyl (OH) radicals are an emerging technique for studying the oxidative aging of organic aerosols. Here, ozone (O3) is photolyzed at 254 nm to produce O(1D) radicals, which react with water vapor to produce OH. However, the need to use parts-per-million levels of O3 hinders the ability of oxidation flow reactors to simulate NOx-dependent secondary organic aerosol (SOA) formation pathways. Simple addition of nitric oxide (NO) results in fast conversion of NOx (NO+NO2) to nitric acid (HNO3), making it impossible to sustain NOx at levels that are sufficient to compete with hydroperoxy (HO2) radicals as a sink for organic peroxy (RO2) radicals. We developed a new method that is well suited to the characterization of NOx-dependent SOA formation pathways in oxidation flow reactors. NO and NO2 are produced via the reaction O(1D)+N2O->2NO, followed by the reaction NO+O3->NO2+O2. Laboratory measurements coupled with photochemical model simulations suggest that O(1D)+N2O reactions can be used to systematically vary the relative branching ratio of RO2 +NO reactions relative to RO2 +HO2 and/or RO2+RO2 reactions over a range of conditions relevant to atmospheric SOA formation. We demonstrate proof of concept using high-resolution time-of-flight chemical ionization mass spectrometer (HR-ToF-CIMS) measurements with nitrate (NO-3 ) reagent ion to detect gas-phase oxidation products of isoprene and -pinene previously observed in NOx-influenced environments and in laboratory chamber experiments.

Lambe, Andrew↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Radiation Chemistry of Solid Acetone in the Interstellar Medium - A New Dimension to an Old Problem

A laboratory investigation of acetone, an interstellar and cometary molecule, has produced new results concerning its decomposition in a radiation environment. Mid-infrared spectroscopy has been used to follow amorphous acetone's destruction by ionizing radiation (1 MeV protons) at 20 K. Radiation products identified are the CH4, CO, and CO2 usually made in such experiments, along with ketene, allene, and the acetonyl radical, all identified here for the first time in irradiated solid acetone. Evidence for the reduction product 2-propanol was suggestive, but a firm identification could not be made either for it or for the C2 hydrocarbons (i.e., C2H6, C2H4, C2H2). The acetyl radical was not observed as a radiation product. Isotopically labeled reagents were used to demonstrate ketene formation and to emphasize that multiple approaches are needed for robust assignments of infrared spectral features of irradiated icy solids. Results from a supporting radiation experiment with isotopically labeled acetic acid are described. Comparisons are made to a previous study of acetone's stability in extraterrestrial radiation environments, and caution is urged in measuring and interpreting CO abundances in irradiated icy solids.

cometary molecule↗

Ionic Liquid Facilitated Recovery of Metals and Oxygen from Regolith

Regolith, being largely composed of metal oxides, has the potential to be an excellent in situ source of metals, such as iron, nickel and aluminum, as well as oxygen. There is, however, no current technology that is suited for the in space separation of metal oxides into their constituent elements. Terrestrial methods require large volumes/masses of hazardous reagents. Alternative methods, such as molten oxide electrolysis, have been investigated, but these processes generally require high temperatures to operate. Such a requirement imposes significant material compatibility restraints, necessitates high energy inputs, and may pose a threat to the health and safety of the crew. This paper discusses a novel process that uses ionic liquids (ILs) to recover high purity metals and oxygen from regolith and meteorite materials. ILs are organic salts that are molten at or near room temperature, and can have a number of attractive properties including wide liquidus ranges and high thermal and electrochemical stability. The structure of an IL can be readily modified to tune these properties, allowing the synthesis of task specific ILs. Together, these attributes give ILs great utility in a number of space related areas, such environmental control and life support, in space repair and manufacture, and in situ resource utilization.

Karr, Laurel J.↗

Radiation Stability Evaluation of Protein-Based Nanopores for Mars and Europa Missions

Exploration of our Solar System has revealed a number of locations that are now habitable or could have supported life in the past. One approach to finding life involves detection of informational polymers like deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) that are definitive biosignatures for life as we know it. Alternatively, structural variants of DNA and RNA, collectively termed xenonucleic acids (XNAs) have been shown in the laboratory to behave similarly. Nanopore-based sequencers differ from traditional sequencing technologies in that they do not explicitly require synthesis of DNA before or during analysis. Because of this, nanopore sequencers have been used for the direct sequencing of RNA, and could be used for the detection and analysis of other charged polymers. Here we describe results of exposing the MinION hardware, flow cells, and key reagents to ionizing radiation at doses relevant to Mars and Europa missions (10 to 3000 silicon-equivalent gray).

Burton, Aaron S.↗

Surface Tension Containment Experiment (STCE) - Increasing Science Throughput on ISS

The Microgravity Science Glovebox (MSG) on the International Space Station (ISS) is used for fluid transfer in many types of experiments. Reagents are handled in the MSG to prevent their accidental release into the cabin. However, the MSG is currently over-subscribed, creating a backlog of users in flight. As a recourse, current experiments are underway to assess the possibility of moving certain science operations from the MSG into the open cabin of the ISS. The experiments are designed to assess the efficacy of exploiting surface tension as a control to prevent the unwanted release of liquids. Dyed water currently serves as an ersatz for potentially more hazardous liquids. Common wet-lab operations such as de/mating wetted Luer-Lok fittings, liquid-bearing container lid removal, and pipetting between well plates are performed illustrating the facility and challenges imposed by the microgravity environment. Concerning the latter, various pipette cannula sizes are deployed at various injection, withdrawal, and translations rates to map the existence, size, velocity, and trajectory of satellite droplets expected to form when breaking contact between the water surface and the pipette tip. Though such drops frequently form in terrestrial operations, they are nearly imperceptible and inconsequential—due in part to their speed and because gravity quickly returns them to the well plate from which they came. The use of airflow to capture and collect such satellite droplets is demonstrated. The dynamic stability of the liquid-filled well plates is quantified in response to a variety of crew-imparted disturbances. From a safety perspective, the results from the STCE are of immediate practical value. If such routine low-gravity capillary fluidic operations can be established as mundane, their performance may be moved out of the MSG and into the cabin, significantly increasing the efficiency of experiments performed on ISS.

Ungar, Eugene K.↗

On-orbit RNA Purification and qRT-PCR Capabilities of the WetLab-2 System

NASA Ames Research Center’s WetLab-2 system brings new capabilities to the ISS for researchers. The system can lyse cells and extract RNA on-orbit from different sample types ranging from microbial cultures to animal tissues. Our purification method has the advantage of using non-toxic chemicals and does not require alcohols or other organics. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (qRT-PCR) analysis without the need for sample return. qRT-PCR reactions are performed by dispensing the RNA into reaction tubes that contain all lyophilized reagents needed to perform the analysis. The system uses a Cepheid® SmartCycler that allows for multiplexing of assays, this can be used to normalize for RNA concentration and integrity and to study multiple genes of interest in each tube. There are a total of 16 independent PCR modules each capable of detecting up to four fluorescent channels. The WetLab- 2 system can downlink data from the ISS to the ground after a completed run and uplink new thermal cycling programs. The ability to purify and stabilize RNA on-orbit can eliminate the confounding effects of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of some samples. It also has the benefit of minimizing the needed downmass. Conducting qRT-PCR and generating results on-orbit is also an important step towards utilizing the ISS as a National Laboratory facility. Specifically, the ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. On orbit gene expression analysis can also provide benchmarking prior to sample return. The system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental pathogens and crew health. The validation flight of the WetLab-2 system using E. coli bacteria and mouse liver is scheduled to launch on SpaceX-8 this spring. Pending operations, the preliminary results from the validation flight will be presented. To support the needs of future researchers, we are adapting our system to purify RNA from two additional sample types: fibrous tissue such as muscle and mammalian adherent cells grown on alginate beads. Progress of this work will also be presented. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

Parra, Macarena↗

Radiation Tolerance of Nanopore Sequencing Technology for Life Detection on Mars and Europa

The search for life beyond Earth is a key motivator in space exploration. Informational polymers, like DNA and RNA, are key biosignatures for life as we know it. The MinION is a miniature DNA sequencer based on versatile nanopore technology that could be implemented on future planetary missions. A critical unanswered question is whether the MinION and its protein-based nanopores can withstand increased radiation exposure outside Earth’s shielding magnetic field. We evaluated the effects of ionizing radiation on the MinION platform – including flow cells, reagents, and hardware – and discovered limited performance loss when exposed to ionizing doses comparable to a mission to Mars. Targets with harsher radiation environments, like Europa, would require improved radiation resistance via additional shielding or design refinements.

Mark A. Sutton↗

Role of the Tenax® Adsorbent in the Interpretation of the EGA and GC‐MS Analyses Performed With the Sample Analysis at Mars in Gale Crater

The Sample Analysis at Mars (SAM) experiment on the National Aeronautics and Space Administration Curiosity rover seeks evidence of organic compounds on the surface of Mars. Since the beginning of the mission, various organic molecules have been detected and identified. While several have been demonstrated to be indigenous to the Martian soil and rocks analyzed, others appear to have been produced from sources internal to the experiment. The objective of this study is to build an exhaustive molecular database to support the interpretation of SAM results by identifying all the chemical species produced from Tenax® adsorbents, by determining (1) the thermal degradation by‐products of Tenax®, (2) the effect of Tenax® conditioning on the formation of Tenax® by‐products, (3) the impact of MTBSTFA or a mixture of MTBSTFA and DMF on Tenax® decomposition, and (4) the reaction between Tenax® and calcium perchlorate. Our results indicate that the by‐products of the SAM trap are due to the impact of trap heating, the impact of the derivatization reagent (MTBSTFA) and the presence of perchlorate in Martian soil. Some of these by‐products are observed in the SAM gas chromatograph mass spectrometer data from Mars.

Buch, A.↗