Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Moessbauer spectrometer for mineralogical analysis of the Mars surface: Moessbauer source considerations

Development of space rocketry and cosmic instrument making has made it possible to create interplanetary stations to be sent to the solar system bodies. In the last decade of the century the planet Mars will be in the focus of planetary science problems. Russia, USA (the NASA) and Europe (the ESA) plan to do a new step in the study of the planetary system by spacecraft missions to Mars. One part of the programs of these missions is Martian surface measurements of iron, which is a dominant element in both the Martian soil and rocks (about 13 percent by weight). The chemistry of iron in space is strongly coupled to the chemistry of abundant elements (to begin with hydrogen, carbon, oxygen) and it is this coupling of chemical cycles of abundant elements that gives us the possibility of understanding some features of the chemical evolution of matter. In this connection of extremely great importance for the understanding of the evolution of the solar system are the oxidation state of the iron and its mineral composition of the Mars surface. Being highly successful, the Viking landers had no instrumentation to answer these questions. Such instrumentation has to be specifically sensitive to mineralogy. For this purpose the back scattering Moessbauer spectrometer (MS-96) was proposed to be installed on a rover to be launched on board the Russian spacecraft Mars-96 mission to Mars. Due to power and mass restrictions three systems of the device MS-96 (velocity transducer, detector and electronic components) have been extremely miniaturized in comparison to a standard system. In this paper we intend to place for consideration a radioactive source to find out what characteristics it should have to be suitable for purposes of the experiment.

Evlanov, E. N.↗

Radioembolization Dosimetry: The Road Ahead

Methods for calculating the activity to be administered during yttrium-90 radioembolization (RE) are largely based on empirical toxicity and efficacy analyses, rather than dosimetry. At the same time, it is recognized that treatment planning based on proper dosimetry is of vital importance for the optimization of the results of RE. The heterogeneous and often clustered intrahepatic biodistribution of millions of point-source radioactive particles poses a challenge for dosimetry. Several studies found a relationship between absorbed doses and treatment outcome, with regard to both toxicity and efficacy. This should ultimately lead to improved patient selection and individualized treatment planning. New calculation methods and imaging techniques and a new generation of microspheres for image-guided RE will all contribute to these improvements. The aim of this review is to give insight into the latest and most important developments in RE dosimetry and to suggest future directions on patient selection, individualized treatment planning, and study designs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical significance of the sterile-neutrino hypothesis in the context of reactor and gallium data

We evaluate the statistical significance of the 3+1 sterile-neutrino hypothesis using $v_e$ and $\bar{v}_e$ disappearance data from reactor, solar and gallium radioactive source experiments. Concerning the latter, we investigate the implications of the recent BEST results. For reactor data we focus on relative measurements independent of flux predictions. For the problem at hand, the usual χ 2 -approximation to hypothesis testing based on Wilks’ theorem has been shown in the literature to be inaccurate. We therefore present results based on Monte Carlo simulations, and find that this typically reduces the significance by roughly 1σ with respect to the naïve expectation. We find no significant indication in favor of sterile-neutrino oscillations from reactor data. On the other hand, gallium data (dominated by the BEST result) show more than 5σ of evidence supporting the sterile-neutrino hypothesis, favoring oscillation parameters in agreement with constraints from reactor data. This explanation is, however, in significant tension (~3 σ) with solar neutrino experiments. In order to assess the robustness of the signal for gallium experiments we present a discussion of the impact of cross-section uncertainties on the results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broad sterile neutrinos & the reactor/gallium tension

Significant evidence exists for the apparent disappearance of electron-type neutrinos in radioactive source experiments. Yet, interpreted within the standard ‘3+1 sterile neutrino scenario’, precision short-baseline measurements of electron antineutrinos from nuclear reactors strongly disagree with these results. Recently, it has been demonstrated that allowing for a finite wavepacket size for the reactor neutrinos can ameliorate such a tension, however the smallness of the required wavepackets is a subject of intense debate. In this work, we demonstrate that a ‘broad’ sterile neutrino may relax this tension in much the same way. Such a phenomenological possibility can arise in plausible hidden sector scenarios, such as a clockwork-style sector, for which we provide a concrete microscopic model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Self-absorption Effects on Alpha-Induced Atmospheric Nitrogen Fluorescence Yield

Nitrogen fluorescence induced by alpha, beta and gamma radiation can be used to detect the presence of radioactive contamination in the environment. Successful measurement of fluorescence yield involves a number of factors, including: known fluorescence signal rate during the measurement; the effective alpha spectrum of the radioactive sources used in the measurement; optical attenuation length of the fluorescence signal in air during the measurement; the absolute throughput of the instrumentation; calibration of the instrumentation; and radiation transport modeling of the "effective" array exposure rate given the spectrum of the alpha particles. Field testing of optical instrumentation was conducted to measure the nitrogen fluorescence yield from the alpha radiation generated from americium-241 (241Am) decay. The 241Am test sources were prepared by direct evaporation of ~1 mCi in nitric acid solution, and some solids were visible on the surface of the sources. A laboratory study was conducted with lower activities of 241Am to determine whether the presence of solids on the surface of the sources prepared both by direct evaporation and by electrodeposition onto stainless steel disks produced sufficient self-absorption to cause a decrease in expected fluorescence. Alpha spectroscopy was used to determine the apparent activity of the sources versus the known activity deposited on the surface. Results from the self-absorption laboratory studies were used to correct the activity values in the model and calculate the nitrogen fluorescence generated by the 241Am during the field experiments.

36 MATERIALS SCIENCE↗

Gamma ray attenuation of hafnium dioxide- and tungsten trioxide-epoxy resin composites

Composites containing WO 3 or HfO 2 nanoparticles were prepared and investigated as alternative shielding materials. Their performance was assessed using radioactive sources emitting photons with energies between 122 and 1407 keV. At 122 keV, the mass attenuation coefficient of the nanocomposites was five times greater to that of the epoxy matrix, and it gradually decreased with increasing energy. An enhancement in the mass attenuation coefficient of the polymer between 15% and 50% was observed at E > 1 MeV when adding the nanoparticles. These results support the development of lightweight garments for radiological application made of nanomaterials and polymeric matrices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results from the third Galaxy Serpent tabletop exercise demonstrating the utility of nuclear forensics libraries in support of an investigation

Galaxy Serpent is a virtual, web-based international ongoing series of tabletop exercises designed to mature the concept of National Nuclear Forensics Libraries (NNFL) and illustrate their utility in answering investigative questions or providing investigative leads as part of an investigation involving nuclear or other radioactive material (R/N) out of regulatory control (MORC). Two prior versions of the exercise have been conducted; the first utilizing surrogate data for spent nuclear fuel as the material of interest, and the second using synthetic sealed radioactive source data. Teams participating in the recently concluded third version of the exercise were provided with synthetic uranium ore concentrate (UOC) data mimicking actual data characteristics (e.g. trace element concentrations), which was used to compile a model NNFL. Teams decided how to organize and interpret the data they were provided, dealt with real world features such as missing data, and assessed discriminating attributes. Next, a hypothetical scenario involving three UOC samples found out of regulatory control was provided, and each team had to assess the self-consistency of the individual sources in the unknown data, and employ their model NNFL as a comparative assessment instrument to determine whether the three UOC materials in question were consistent with any of the types of materials in their library. In conclusion, the design of the exercise, methodologies utilized by participating teams, and aggregate results of the exercise will be presented, along with challenges encountered and benefits realized.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Multifunctional Thin Film Based X-Ray Intensity Filters for Space-Based Payloads

We report the development, thorough characterizations and space worthiness studies of multifunctional aluminized film as x-ray intensity filter for space-based payloads, suitably designed to place in Sun–Earth Lagrangian (L1) point. The L1 point is the ideal location for uninterrupted observation of Sun to study the solar flares in hard x-rays. For our specific purpose, we make use of two different types of x-ray detectors (e.g., CdTe and CZT) which are generally used for hard x-ray studies in the energy band of 5 to 200 keV. Further, these aforesaid two detectors require specified thermal control characteristic for optimal performance. Aluminization of Kapton films is proposed which would satisfy the thermo-optical and x-ray transmission requirements of the proposed payload. The developed aluminized films are thoroughly studied by field emission scanning electron microscopy and atomic force microscopy techniques for micro-structural characteristic, x-ray diffraction for phase purity, nanoindentation for mechanical integrity at micro-structural length scale and spectrophotometer for thermo-optical properties. X-ray transmission test is carried out with two radioactive sources, namely {sup 55}Fe and {sup 241}Am, with various aluminized Kapton layer combinations. Finally, space worthiness of the aluminized Kapton films is examined by accelerated environments, e.g. humidity, thermal cycling and thermo-vacuum tests.

36 MATERIALS SCIENCE↗

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗

Data acquisition and readout system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This work describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

36 MATERIALS SCIENCE↗

Localization and spectral isolation of special nuclear material using stochastic image reconstruction

Here, in this work we present a technique for isolating the gamma-ray and neutron energy spectra from multiple radioactive sources localized in an image. Image reconstruction algorithms for radiation scatter cameras typically focus on improving image quality. However, with scatter cameras being developed for non-proliferation applications, there is a need for not only source localization but also source identification. This work outlines a modified stochastic origin ensembles algorithm that provides localized spectra for all pixels in the image. We demonstrated the technique by performing three experiments with a dual-particle imager that measured various gamma-ray and neutron sources simultaneously. We showed that we could isolate the peaks from 22 Na and 137 Cs and that the energy resolution is maintained in the isolated spectra. To evaluate the spectral isolation of neutrons, a 252 Cf source and a PuBe source were measured simultaneously and the reconstruction showed that the isolated PuBe spectrum had a higher average energy and a greater fraction of neutrons at higher energies than the 252 Cf. Finally, spectrum isolation was used for an experiment with weapons grade plutonium, 252 Cf, and AmBe. The resulting neutron and gamma-ray spectra showed the expected characteristics that could then be used to identify the sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗