Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

Detectors↗

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser adaptive holographic hydroacoustic intensimeter

A new type of a vector hydrophone, a laser adaptive hydroacoustic intensimeter, is investigated. Two identical, spatially separated coil-type sensors are used as a primary receiver of the acoustic signal. The signals received at the sensor output are phase demodulated in a two-channel adaptive holographic interferometer based on two dynamic holograms multiplexed in a CdTe photorefractive crystal. Using a laser intensimeter, the acoustic field formed in a limited volume is studied. The performance characteristics of the intensimeter are determined experimentally; its threshold sensitivity, according to the acoustic field intensity, constitutes 0.1 × 10{sup −13} W m{sup −2}. (laser applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum sensing of paramagnetic analytes by nanodiamonds in levitated microdroplets and aqueous solutions

Nanodiamonds (ND) hosting negatively charged nitrogen-vacancy (NV-) color centers have received attention for applications in magnetic field, electric field, chemical, and bio-sensing. The versatility of these probes is their excellent room-temperature optical and spin properties, along with their small size, functionalized surfaces and resistance to bleaching, making them ideal as nanoscopic sensors in picoliter volumes (e.g. single cells, but also microcompartments and aerosols). For quantitative ND-NV- sensing of paramagnetic analytes in such contexts, however, there remains an incomplete understanding of how factors related to the aqueous phase environment control detection efficiency. To address this, optically detected magnetic resonance (ODMR) is measured in bulk macroscale solutions and single levitated microdroplets as a function of Gd+3 concentration (340 nM to 1.5 mM), nanodiamond size, pH, competitor ions, and ligands. The ODMR response to [Gd+3] is found to be nonlinear, and pH, ND and sample volume dependent; indicating the detection of Gd+3 requires efficient adsorption of the analyte to the diamond surface. Langmuir adsorption isotherms embedded in a quantitative photophysical model links the ODMR response to adsorption thermodynamics of Gd+3. The equilibrium constant for Gd+3 adsorption to a carboxylated ND surface is determined to be (1 ± 0.5) x 105 M-1 corresponding to a free energy of adsorption of (-28 ± 1) kJ mol-1. These results provide general insight into how complex aqueous and microscale environments impact nanodiamond based quantum sensing modalities, and portend their application as quantitative chemical sensors in microenvironments.

Brown, Emily K↗

X-ray characterization of fully-depleted p-channel Skipper-CCDs for the DarkNESS mission

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) mission is a 6U CubeSat designed to search for X-ray lines from decaying dark matter using Skipper-CCDs. Thick, fully-depleted p-channel Skipper-CCDs provide low readout noise and high quantum efficiency for 1-10 keV X-rays, but their X-ray performance has not yet been demonstrated in the space environment. DarkNESS will operate in low-Earth orbit, where trapped protons induce displacement damage in the sensor that increases charge-transfer inefficiency and degrades the X-ray energy resolution. This work measures the X-ray line response of Skipper-CCDs before and after proton irradiation and quantifies the associated degradation. A sensor was exposed to 217 MeV protons at a fluence of 8.4 x 10^10 protons cm^-2, corresponding to a displacement-damage dose more than an order of magnitude above the three-year expectation for representative mid-inclination and Sun-synchronous low-Earth orbits. A 55Fe source was used to compare the energy resolution of the beam-exposed quadrant to adjacent unexposed quadrants and a non-irradiated reference sensor. These measurements provide a quantitative assessment of radiation-induced spectral degradation in Skipper-CCDs and enable an estimate of the end-of-life X-ray energy resolution expected for DarkNESS operation in low-Earth orbit.

Alpine, Phoenix [Illinois U., Urbana] (ORCID:00090↗

Enhanced Carbon Dioxide Uptake in Drilled Hollow Core Fibers for Raman Spectroscopy

Fiber-based Raman spectroscopy enhances the Raman signal by maximizing the overlap of the optical field and the gas species. However, filling the hollow-core fiber (HCF) with gas requires time that is dependent on the fiber core diameter, fiber length, and pressure of the gas. At ambient pressure, the fiber gas uptake is driven by diffusion into the fiber ends, severely limiting the response time of the system. By laser drilling access holes to the core along the length of the fiber, the uptake time of the gas is reduced, improving the system response time. In this work, we study the carbon dioxide (CO 2 ) sensor dynamics based on Raman signal intensity generated in HCFs. The signal intensity versus gas concentration is characterized by controlling the CO 2 concentration in the surrounding environment of the fiber. Next, we characterize the gas uptake time in HCFs as a function of fiber length. Finally, we optimize the access hole configuration along the fiber, demonstrating reduced sensor uptake time by a factor of three.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aqueous phosphate detection using Eu(acac) 3

Currently, the majority of phosphate-sensitive phosphors reported in literature are metal-based complexes that require complicated and expensive synthesis to prepare. Here, in this study, we investigate the phosphate detecting capabilities of an inexpensive off-the-shelf phosphor: Eu(acac) 3 . We characterize its phosphate sensitivity as a function of sensor concentration and find that the quenching coefficient is inversely proportional to sensor concentration. This results in the limit-of-detection scaling linearly with sensor concentration. We determine its concentration-independent sensitivity to be 1.558 ± 0.012, which results in our lowest sensor concentration (44 μM) having a limit-of-detection of 3.39 ± 0.68 μM. We also find that for phosphate concentrations less than the sensor concentration, the fluorescence intensity ratio behaves linearly, but transitions to a non-linear functionality as the phosphate concentration exceeds the sensor concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A room-temperature polarization-sensitive CMOS terahertz camera based on quantum-dot-enhanced terahertz-to-visible photon upconversion

Detection of terahertz (THz) radiation has many potential applications, but presently available detectors are limited in many aspects of their performance, including sensitivity, speed, bandwidth and operating temperature. Most do not allow the characterization of THz polarization states. Recent observation of THz-driven luminescence in quantum dots offers a possible detection mechanism via field-driven interdot charge transfer. Here, we demonstrate a room-temperature complementary metal–oxide–semiconductor THz camera and polarimeter based on quantum-dot-enhanced THz-to-visible upconversion mechanism with optimized luminophore geometries and fabrication designs. Besides broadband and fast responses, the nanoslit-based sensor can detect THz pulses with peak fields as low as 10 kV cm–1. A related coaxial nanoaperture-type device shows a to-date-unexplored capability to simultaneously record the THz polarization state and field strength with similar sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Lidar-based remote infrared gas sensor for monitoring anthropogenic pollution: a proof of concept

We propose using wavelength-modulation laser absorption spectroscopy in combination with quadrature detection of scattered light for remote industrial pollution monitoring in the atmosphere with a compact lidar-based gas sensor, which can be mounted on board an unmanned aerial vehicle. The instrument can be used for detecting leaks in product pipe lines; monitoring toxic gases near landfill sites, waste incineration plants, and other hazardous man-made facilities; analysing the gas atmosphere in industrial buildings and structures; and monitoring engineering processes at a sensitivity level of tens of ppm m in gas concentration measurements at characteristic distances of tens of metres. (laser applications and other issues in quantum electronics)

42 ENGINEERING↗

Visualizing the atomic-scale origin of metallic behavior in Kondo insulators

A Kondo lattice is often electrically insulating at low temperatures. However, several recent experiments have detected signatures of bulk metallicity within this Kondo insulating phase. In this study, we visualized the real-space charge landscape within a Kondo lattice with atomic resolution using a scanning tunneling microscope. We discovered nanometer-scale puddles of metallic conduction electrons centered around uranium-site substitutions in the heavy-fermion compound uranium ruthenium silicide (URu 2 Si 2 ) and around samarium-site defects in the topological Kondo insulator samarium hexaboride (SmB 6 ). These defects disturbed the Kondo screening cloud, leaving behind a fingerprint of the metallic parent state. Our results suggest that the three-dimensional quantum oscillations measured in SmB 6 arise from Kondo-lattice defects, although we cannot exclude other explanations. Finally, our imaging technique could enable the development of atomic-scale charge sensors using heavy-fermion probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs

This paper presents a proof-of-concept demonstration of the Skipper-charge coupled device (CCD), a sensor with single-electron counting capability, as a promising technology for implementing an electron-pump-based current source. Relying on its single-electron resolution and built-in charge sensing, it allows self-calibration of the charge packets. This article presents an initial discussion of the uncertainty in the charge measurement and achievable currents levels with this technology. Here, we report experimental results that illustrate the key functionalities in manipulating both small and large electron charge packets, including a comparison of the charge generated, self-measured, and drained by the sensor against measurements from an electrometer. These results were obtained using a standard sensor and readout electronics without specific optimizations for this application. The objective is to explore the potential of Skipper-CCD for realizing an electron-based current source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fluorescent-protein spin qubit

Quantum bits (qubits) are two-level quantum systems that support initialization, readout and coherent control1. Optically addressable spin qubits form the foundation of an emerging generation of nanoscale sensors. The engineering of these qubits has mainly focused on solid-state systems. However, fluorescent proteins, rather than exogenous fluorescent probes, have become the gold standard for in vivo microscopy because of their genetic encodability. Although fluorescent proteins possess a metastable triplet state, they have not been investigated as qubits. Here we realize an optically addressable spin qubit in enhanced yellow fluorescent protein. A near-infrared laser pulse enables triggered readout of the triplet state with up to 20% spin contrast. Using coherent microwave control of the enhanced-yellow-fluorescent-protein spin at liquid-nitrogen temperatures, we measure a (16 ± 2) μs coherence time under Carr–Purcell–Meiboom–Gill decoupling. We express the qubit in mammalian cells, maintaining contrast and coherent control despite the complex intracellular environment. Finally, we demonstrate optically detected magnetic resonance in bacterial cells at room temperature with contrast up to 8%. Our results introduce fluorescent proteins as a powerful qubit platform that paves the way for applications in the life sciences, such as nanoscale field sensing and spin-based imaging modalities.

Feder, Jacob S. [Univ. of Chicago, IL (United Stat↗

Cyclic superconducting refrigerators using guided fluxon propagation

We propose cyclic refrigeration in solid state, employing a gas of magnetic field vortices in a type-II superconductor—also known as fluxons—as the cooling agent. Refrigeration cycles are realized by envisioning a racetrack geometry consisting of both adiabatic and isothermal arms, etched into a type-II superconductor. The guided propagation of fluxons in the racetrack is achieved by applying an external electrical current, in a Corbino geometry, through the sample. A gradient of magnetic field is set across the racetrack allowing one to adiabatically cool down and heat up the fluxons, which subsequently exchange heat with the cold and hot reservoirs, respectively. We characterize the steady state of refrigeration cycles thermodynamically for both s -wave and d -wave pairing symmetries, and present their figures of merit such as the cooling power delivered, and the coefficient of performance. Our cooling principle can offer significant cooling for on-chip microrefrigeration purposes, by locally cooling below the base temperatures achievable in a conventional dilution refrigerator. We estimate n W / m m 2 of cooling power per unit area assuming a tunnel coupling with ∼ M Ω µ m 2 specific resistance. Integrating the fluxon fridge to quantum circuits can enhance their coherence time by locally suppressing thermal fluctuations, and improve the efficiency of single photon detectors and charge sensors. Published by the American Physical Society 2024

Karmakar, Tathagata (ORCID:0000000187812017)↗

Demonstration of the HeRALD superfluid helium detector concept

The SPICE/HeRALD collaboration is performing research and development to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid 4 He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and 4 He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical “quantum evaporation” signal from 4 He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype “HeRALD v0.1” detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. Here, a key result of this work is the measurement of the quantum evaporation channel’s gain of 0.15±0.01, which will enable 4 He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5⁢σ, which would be sensitive to dark matter masses down to 220 MeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗