A survey of groups and instrumentation concerned with measurement of the neutral composition of the upper atmosphere /1963/
Aeronomy research and quadrupole mass spectrometers for neutral atmospheric composition measurements
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Aeronomy research and quadrupole mass spectrometers for neutral atmospheric composition measurements
Quadrupole mass spectrometer for determining relationship between partial pressures and filament temperature in synthesis of hydrocarbons
Quadrupole effects on gas diffusion, viscosity and thermal diffusion factors, computing collision integrals
The heterogeneous reactions on liquid sulfuric acid surfaces have been studied using a fast flow-reactor coupled to a quadrupole mass spectrometer.
Using a fast-flow reactor coupled to a quadrupole mass spectrometer, the heterogeneous reactions of C1ONO2 + HCl and HOCl + HCl as well as hydrolysis of N2O5 and C1ONO2 were investigated on liquid sulfuric acid, with particular emphasis on the effect of incorporation of HNO3 on the reaction probabilities.
The combustion experiment on the Sample Analysis at Mars (SAM) suite on Curiosity will heat a sample of Mars regolith in the presence of oxygen and measure composition of the evolved gases using quadrupole mass spectrometry (QMS) and tunable laser spectrometry (TLS). QMS will enable detection of combustion products such as CO, CO2, NO, and other oxidized species, while TLS will enable precise measurements of the abundance and carbon isotopic composition (delta(sup 13)C) of the evolved CO2 and hydrogen isotopic composition (deltaD) of H2O. SAM will perform a two-step combustion to isolate combustible materials below approx.550 C and above approx.550 C. The combustion experiment on SAM, if properly designed and executed, has the potential to answer multiple questions regarding the origins of volatiles seen thus far in SAM evolved gas analysis (EGA) on Mars. Constraints imposed by SAM and MSL time and power resources, as well as SAM consumables (oxygen gas), will limit the number of SAM combustion experiments, so it is imperative to design an experiment targeting the most pressing science questions. Low temperature combustion experiments will primarily target the quantification of carbon (and nitrogen) contributed by SAM wet chemistry reagants MTBSTFA (N-Methyl-N-tert-butyldimethylsilyltrifluoroacetamide) and DMF (Dimethylformamide), which have been identified in the background of blank and sample runs and may adsorb to the sample while the cup is in the Sample Manipulation System (SMS). In addition, differences between the sample and "blank" may yield information regarding abundance and delta(sup 13)C of bulk (both organic and inorganic) martian carbon. High temperature combustion experiments primarily aim to detect refractory organic matter, if present in Cumberland fines, as well as address the question of quantification and deltaD value of water evolution associated with hydroxyl hydrogen in clay minerals.
We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.
We have investigated some thermodynamic properties (i.e. freezing/melting points)and heterogeneous chemistry of sulfuric acid monohydrate, using a fast flow-reactor coupled to a quadrupole mass spectrometer.
Determination of the netrual atmospheric composition between 100 and 200 km, using a rocket-borne quadrupole mass spectrometer
Hydrogen quadrupole, water vapor and carbon dioxide spectral band intensities with reference to planetary atmosphere observations
Nike-Cajun measurements of upper air neutral composition by quadrupole mass spectrometer designed to minimize recombination effect
Superconducting magnetic bottle consisting of two mirror coils, central field coil and quadrupole cusp field coil
Cold cathode ion source mated to quadrupole mass spectrometer for use as residual gas analyzer
Exhaust beam from colloid thrustor investigated, using quadrupole mass filter
Superconducting magnetic bottle consisting of two mirror coils, central field coil and quadrupole field coil
Ion sources with magnetically aligned electron beam and compatibility with quadrupole mass spectrometer for planetary atmospheric analysis
Nuclear magnetic resonance and nuclear quadrupole resonance techniques for nondestructive testing of reinforced plastics for curing and internal stresses
Photoionization by spin-dependent electric dipole and spin-dependent magnetic quadrupole transitions with polarized electron spin