Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Programmable devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Alumina–Titania Nanolaminate Condensers for Hot Programmable Catalysis

Nanolaminates composed of thin alternating layers of Al2O 3 and TiO 2 (ATO) were engineered by using atomic layer deposition as the dielectric material for a Pt-on-carbon catalytic condenser. Investigation assessed synthesis parameters including the deposition temperature, Al 2 O 3 and TiO 2 layer thicknesses, total number of layers, and a capping Al 2 O 3 layer on the maximum charge accumulation in the Pt catalyst. The highest capacitance ATO configuration demonstrated a specific capacitance of ∼1200 nF/cm 2 with working voltages of ±5 V, enabling the storage of 4 × 10 13 electrons or holes per cm 2 at room temperature. The ATO devices exhibited enhanced capacitance at elevated temperatures of up to 400 °C, suggesting the suitability of these materials for high-temperature applications. Adsorption of carbon monoxide on the Pt/C-ATO device characterized by grazing incidence infrared spectroscopy showed changes in the surface binding energy of 13.1 ± 0.8 kJ/mol for an applied external voltage bias of ±1 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active mixing of complex fluids at the microscale

Mixing of complex fluids at low Reynolds number is fundamental for a broad range of applications, including materials assembly, microfluidics, and biomedical devices. Of these materials, yield stress fluids (and gels) pose the most significant challenges, especially when they must be mixed in low volumes over short timescales. New scaling relationships between mixer dimensions and operating conditions are derived and experimentally verified to create a framework for designing active microfluidic mixers that can efficiently homogenize a wide range of complex fluids. As a result, active mixing printheads are then designed and implemented for multimaterial 3D printing of viscoelastic inks with programmable control of local composition.

36 MATERIALS SCIENCE↗

Programmable stream prefetch with resource optimization

A stream prefetch engine performs data retrieval in a parallel computing system. The engine receives a load request from at least one processor. The engine evaluates whether a first memory address requested in the load request is present and valid in a table. The engine checks whether there exists valid data corresponding to the first memory address in an array if the first memory address is present and valid in the table. The engine increments a prefetching depth of a first stream that the first memory address belongs to and fetching a cache line associated with the first memory address from the at least one cache memory device if there is not yet valid data corresponding to the first memory address in the array. The engine determines whether prefetching of additional data is needed for the first stream within its prefetching depth. The engine prefetches the additional data if the prefetching is needed.

97 MATHEMATICS AND COMPUTING↗

Heterosynaptic plasticity in biomembrane memristors controlled by pH

Abstract In biology, heterosynaptic plasticity maintains homeostasis in synaptic inputs during associative learning and memory, and initiates long-term changes in synaptic strengths that nonspecifically modulate different synapse types. In bioinspired neuromorphic circuits, heterosynaptic plasticity may be used to extend the functionality of two-terminal, biomimetic memristors. In this article, we explore how changes in the pH of droplet interface bilayer aqueous solutions modulate the memristive responses of a lipid bilayer membrane in the pH range 4.97–7.40. Surprisingly, we did not find conclusive evidence for pH-dependent shifts in the voltage thresholds ( V* ) needed for alamethicin ion channel formation in the membrane. However, we did observe a clear modulation in the dynamics of pore formation with pH in time-dependent, pulsed voltage experiments. Moreover, at the same voltage, lowering the pH resulted in higher steady-state currents because of increased numbers of conductive peptide ion channels in the membrane. This was due to increased partitioning of alamethicin monomers into the membrane at pH 4.97, which is below the pKa (~5.3–5.7) of carboxylate groups on the glutamate residues of the peptide, making the monomers more hydrophobic. Neutralization of the negative charges on these residues, under acidic conditions, increased the concentration of peptide monomers in the membrane, shifting the equilibrium concentrations of peptide aggregate assemblies in the membrane to favor greater numbers of larger, increasingly more conductive pores. It also increased the relaxation time constants for pore formation and decay, and enhanced short-term facilitation and depression of the switching characteristics of the device. Modulating these thresholds globally and independently of alamethicin concentration and applied voltage will enable the assembly of neuromorphic computational circuitry with enhanced functionality. Impact statement We describe how to use pH as a modulatory “interneuron” that changes the voltage-dependent memristance of alamethicin ion channels in lipid bilayers by changing the structure and dynamical properties of the bilayer. Having the ability to independently control the threshold levels for pore conduction from voltage or ion channel concentration enables additional levels of programmability in a neuromorphic system. In this article, we note that barriers to conduction from membrane-bound ion channels can be lowered by reducing solution pH, resulting in higher currents, and enhanced short-term learning behavior in the form of paired-pulse facilitation. Tuning threshold values with environmental variables, such as pH, provide additional training and learning algorithms that can be used to elicit complex functionality within spiking neural networks. Graphical abstract

36 MATERIALS SCIENCE↗

An automated platform for in situ serial crystallography at room temperature

Direct observation of functional motions in protein structures is highly desirable for understanding how these nanomachineries of life operate at the molecular level. Because cryogenic temperatures are non-physiological and may prohibit or even alter protein structural dynamics, it is necessary to develop robust X-ray diffraction methods that enable routine data collection at room temperature. We recently reported a crystal-on-crystal device to facilitate in situ diffraction of protein crystals at room temperature devoid of any sample manipulation. Here an automated serial crystallography platform based on this crystal-on-crystal technology is presented. A hardware and software prototype has been implemented, and protocols have been established that allow users to image, recognize and rank hundreds to thousands of protein crystals grown on a chip in optical scanning mode prior to serial introduction of these crystals to an X-ray beam in a programmable and high-throughput manner. This platform has been tested extensively using fragile protein crystals. We demonstrate that with affordable sample consumption, this in situ serial crystallography technology could give rise to room-temperature protein structures of higher resolution and superior map quality for those protein crystals that encounter difficulties during freezing. This serial data collection platform is compatible with both monochromatic oscillation and Laue methods for X-ray diffraction and presents a widely applicable approach for static and dynamic crystallographic studies at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HIDRA-MAT liquid metal droplet injector for liquid metal applications in HIDRA

A liquid metal droplet injector was explicitly designed for the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT) at the University of Illinois Urbana-Champaign to prepare liquid metal plasma-facing components (PFCs) for plasma exposure. The design goals were to create a compact, reliable, and robust design that could apply liquid metal droplets in-vacuo to a variety of samples. The injector was designed for liquid metal use, and results discussed pertain to lithium. The injector can produce lithium droplets of consistent size by utilizing programmable piston movement. Here, droplet formation data is presented for four different piston step sizes (0.125 mm, 0.25 mm, 0.5 mm, and 1 mm) at three different nozzle temperatures (185 °C, 230 °C, and 270 °C). Droplets are formed on the injector nozzle tip and a linear shift mechanism vertically translates the droplet to the substrate for application. This design prevents the droplet from inadvertently detaching off the nozzle and falling to the sample. Application of the liquid metal droplet ensures placement consistency on the substrate and helps avoid damage to components in HIDRA-MAT that should not interact with liquid metals. A description of the liquid lithium droplet creation and application results is given and provides additional insight into the cooling and oxidation of lithium droplets under vacuum conditions. A second nozzle was fabricated and demonstrated repeatability in droplet diameter creation having a variance of ±0.14 mm for droplets created from the same number of piston steps. The end-use for the injector on HIDRA-MAT is to apply liquid metals to PFCs and expose them to HIDRA's plasma with subsequent intershot in-vacuo surface analysis in HIDRA-MAT for plasma-material interaction studies.

42 ENGINEERING↗

Precompensation of gain nonuniformity in a Nd:glass amplifier using a programmable beam-shaping system

A programmable liquid crystal beam-shaping system was installed for a 200-mJ optical parametric chirped-pulse amplification (OPCPA) system front end and was applied to dramatically improve the beam uniformity in the subsequent amplifier. A highly nonuniform beam profile caused by gain inhomogeneity in the amplifier was pre-compensated by the beam shaping system using significantly improved open-loop and closed-loop algorithms. The details of the improved algorithms will be described. The issues of running a liquid crystal device with a high-energy, ultrashort-pulse laser, such as damage risk and temporal contrast degradation, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Special Issue on the 22nd International Spherical Torus Workshop, 21–24 October 2024

This Special Issue contains papers resulting from research presented at the 22nd International Spherical Torus Workshop (ISTW), which was held during 21–24 October 2024, in Oxford, UK. The objectives of this workshop were to contribute to advancing the understanding of spherical tori (ST) configurations and to enhance their potential for fusion power applications. The scope of the meeting covers the full range of research activities on STs and aims to provide a forum for discussion and collaboration enhancement. The ISTW is organized by the International Energy Agency Technology Collaboration Programme on ST [1], and the 22nd was the latest in a series that started in 1994, but due to the global pandemic it had not been held in person for 5 years. With 15 thirty-minute overview presentations, 33 twenty-minute presentations, 32 posters and 93 total attendees, the 22nd ISTW was, to our knowledge, the largest to date. Representatives attended from at least 9 countries, representing at least 24 institutions, and presenting results from at least 18 existing or planned devices. Furthermore, this demonstrates the current broad interest in STs as fusion research devices and as candidates for future fusion pilot plants. Following on this momentum, the 23rd ISTW is planned to be held in Seville, Spain in late 2026.

Berkery, John W. [Princeton Plasma Physics Laborat↗

Design of a laser-induced breakdown spectroscopy system for on-line quality analysis of pulverized coal in power plants

It is vitally important for a power plant to determine the chemical composition of coal prior to combustion in order to obtain optimal boiler control. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) system comprising a LIBS apparatus and sampling equipment has been designed for possible application to power plants for on-line quality analysis of pulverized coal. Special attention was given to the LIBS system, the data processing methods (especially the normalization with Bode Rule/DC Level) and the specific settings (the software-controlled triggering source, high-pressure gas cleaning device, sample preparation module, sampling module, etc.), which gave the best direct measurement for C, H, Si, Na, Mg, Fe, Al, and Ti with measurement errors less than 10% for pulverized coal. Therefore, the apparatus is accurate enough to be applied to industries for on-line monitoring of pulverized coal. The method of proximate analysis was also introduced and the experimental error of A(ad) (Ash, 'ad' is an abbreviation for 'air dried') was shown in the range of 2.29 to 13.47%. The programmable logic controller (PLC) controlled on-line coal sampling equipment, which is designed based upon aerodynamics, and is capable of performing multipoint sampling and sample-preparation operation.

01 COAL, LIGNITE, AND PEAT↗

Beam Polarization at the ILC: the Physics Impact and the Accelerator Solutions

In this contribution accelerator solutions for polarized beams and their impact on physics measurements are discussed. Focus are physics requirements for precision polarimetry near the interaction point and their realization with polarized sources. Based on the ILC baseline programme as described in the Reference Design Report (RDR), recent developments are discussed and evaluated taking into account physics runs at beam energies between 100 GeV and 250 GeV, as well as calibration runs on the Z-pole and options as the 1TeV upgrade and GigaZ. The studies, talks and discussions presented at this conference demonstrated that beam polarization and its measurement are crucial for the physics success of any future linear collider. To achieve the required precision it is absolutely decisive to employ multiple devices for testing and controlling the systematic uncertainties of each polarimeter. The polarimetry methods for the ILC are complementary: with the upstream polarimeter the measurements are performed in a clean environment, they are fast and allow to monitor time-dependent variations of polarization. The polarimeter downstream the IP will measure the disrupted beam resulting in high background and much lower statistics, but it allows access to the depolarization at the IP. Cross checks between the polarimeter results give redundancy and inter-calibration which is essential for high precision measurements. Current plans and issues for polarimeters and also energy spectrometers in the Beam Delivery System of the ILC are summarized in reference [28]. The ILC baseline design allows already from the beginning the operation with polarized electrons and polarized positrons provided the spin rotation and the fast helicity reversal for positrons will be implemented. A reversal of the positron helicity significantly slower than that of electrons is not recommended to not compromise the precision and hence the success of the ILC. Recently to use calibration data at the Z resonance for physics has been discussed. It looks promising but further studies are needed to evaluate and to optimize these measurements. Finally it should be remarked: many studies on different physics processes and scenarios at a future linear collider are done for high luminosities and high energy assuming small and well-known uncertainties. Polarization, especially positron polarization, is often considered as not that important. But in order to interpret data and to reduce ambiguities in the measurements, the polarization of electrons and positrons and their very precise knowledge are essential. The ILC design must offer this from the beginning to be prepared for the physics questions after years of LHC operation.

43 PARTICLE ACCELERATORS↗

Energy efficient photonic memory based on electrically programmable embedded III-V/Si memristors: switches and filters

Abstract Over the past few years, extensive work on optical neural networks has been investigated in hopes of achieving orders of magnitude improvement in energy efficiency and compute density via all-optical matrix-vector multiplication. However, these solutions are limited by a lack of high-speed power power-efficient phase tuners, on-chip non-volatile memory, and a proper material platform that can heterogeneously integrate all the necessary components needed onto a single chip. We address these issues by demonstrating embedded multi-layer HfO 2 /Al 2 O 3 memristors with III-V/Si photonics which facilitate non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers, and (de-)interleaver filters. The Mach-Zehnder optical memristor exhibits non-volatile optical phase shifts > π with ~33 dB signal extinction while consuming 0 electrical power consumption. We demonstrate 6 non-volatile states each capable of 4 Gbps modulation. (De-) interleaver filters were demonstrated to exhibit memristive non-volatile passband transformation with full set/reset states. Time duration tests were performed on all devices and indicated non-volatility up to 24 hours and beyond. We demonstrate non-volatile III-V/Si optical memristors with large electric-field driven phase shifts and reconfigurable filters with true 0 static power consumption. As a result, co-integrated photonic memristors offer a pathway for in-memory optical computing and large-scale non-volatile photonic circuits.

Cheung, Stanley (ORCID:0000000248860013)↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Abisko: Deep codesign of an architecture for spiking neural networks using novel neuromorphic materials

The Abisko project aims to develop an energy-efficient spiking neural network (SNN) computing architecture and software system capable of autonomous learning and operation. The SNN architecture explores novel neuromorphic devices that are based on resistive-switching materials, such as memristors and electrochemical RAM. Equally important, Abisko uses a deep codesign approach to pursue this goal by engaging experts from across the entire range of disciplines: materials, devices and circuits, architectures and integration, software, and algorithms. Here, the key objectives of our Abisko project are threefold. First, we are designing an energy-optimized high-performance neuromorphic accelerator based on SNNs. This architecture is being designed as a chiplet that can be deployed in contemporary computer architectures and we are investigating novel neuromorphic materials to improve its design. Second, we are concurrently developing a productive software stack for the neuromorphic accelerator that will also be portable to other architectures, such as field-programmable gate arrays and GPUs. Third, we are creating a new deep codesign methodology and framework for developing clear interfaces, requirements, and metrics between each level of abstraction to enable the system design to be explored and implemented interchangeably with execution, measurement, a model, or simulation. As a motivating application for this codesign effort, we target the use of SNNs for an analog event detector for a high-energy physics sensor.

97 MATHEMATICS AND COMPUTING↗

Portable multiplicity counter

A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

47 OTHER INSTRUMENTATION↗

Quantitative and Predictive Genetic Parts for Plant Synthetic Biology

Plant synthetic biology aims to harness the natural abilities of plants and to turn them to new purposes. A primary goal of plant synthetic biology is to produce predictable and programmable genetic circuits from simple regulatory elements and well-characterized genetic components. The number of available DNA parts for plants is increasing, and the methods for rapid quantitative characterization are being developed, but the field of plant synthetic biology is still in its early stages. We here describe methods used to describe the quantitative properties of genetic components needed for plant synthetic biology. Once the quantitative properties and transfer function of a variety of genetic parts are known, computers can select the optimal components to assemble into functional devices, such as toggle switches and positive feedback circuits. However, while the variety of circuits and traits that can be put into plants are limitless, doing synthetic biology in plants poses unique challenges. Plants are composed of differentiated cells and tissues, each representing potentially unique regulatory or developmental contexts to introduced synthetic genetic circuits. Further, plants have evolved to be highly sensitive to environmental influences, such as light or temperature, any of which can affect the quantitative function of individual parts or whole circuits. Measuring the function of plant components within the context of a plant cell and, ideally, in a living plant, will be essential to using these components in gene circuits with predictable function. Mathematical modeling will be needed to account for the variety of contexts a genetic part will experience in different plant tissues or environments. With such understanding in hand, it may be possible to redesign plant traits to serve human and environmental needs.

59 BASIC BIOLOGICAL SCIENCES↗

Development of intelligent instruments with embedded HTTP servers for control and data acquisition in a cryogenic setup—The hardware, firmware, and software implementation

The power of Ethernet for control and automation technology is being largely understood by the automation industry in recent times. Ethernet with HTTP (Hypertext Transfer Protocol) is one of the most widely accepted communication standards today. Ethernet is best known for being able to control through internet from anywhere in the globe. The Ethernet interface with built-in on-chip embedded servers ensures global connections for crate-less model of control and data acquisition systems which have several advantages over traditional crate-based control architectures for slow applications. This architecture will completely eliminate the use of any extra PLC (Programmable Logic Controller) or similar control hardware in any automation network as the control functions are firmware coded inside intelligent meters itself. Here, we describe the indigenously built project of a cryogenic control system built for linear accelerator at Inter University Accelerator Centre, known as “CADS,” which stands for “Complete Automation of Distribution System.” CADS deals with complete hardware, firmware, and software implementation of the automated linac cryogenic distribution system using many Ethernet based embedded cryogenic instruments developed in-house. Each instrument works as an intelligent meter called device-server which has the control functions and control loops built inside the firmware itself. Dedicated meters with built-in servers were designed out of ARM (Acorn RISC (Reduced Instruction Set Computer) Machine) and ATMEL processors and COTS (Commercially Off-the-Shelf) SMD (Surface Mount Devices) components, with analog sensor front-end and a digital back-end web server implementing remote procedure call over HTTP for digital control and readout functions. At present, 24 instruments which run 58 embedded servers inside, each specific to a particular type of sensor-actuator combination for closed loop operations, are now deployed and distributed across control LAN (Local Area Network). A group of six categories of such instruments have been identified for all cryogenic applications required for linac operation which were designed to build this medium-scale cryogenic automation setup. These devices have special features like remote rebooters, daughter boards for PIDs (Proportional Integral Derivative), etc., to operate them remotely in radiation areas and also have emergency switches by which each device can be taken to emergency mode temporarily. Finally, all the data are monitored, logged, controlled, and analyzed online at a central control room which has a user-friendly control interface developed using LabVIEW{sup ®}. This paper discusses the overall hardware, firmware, software design, and implementation for the cryogenics setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CyOTE ASSET OWNER ENGAGEMENT – SIDE CHANNEL POWER ANALYSIS PROTOTYPE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently identify adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. The CyOTE methodology seeks to identify adversarial techniques within an AOO OT environment that could result in physical disruptions to energy flow or damage to equipment. CyOTE provides a general roadmap for AOOs, starting from a triggering event, or the point in time and space they perceive an anomalous event or condition meriting investigation, and culminating when the AOO has sufficient confidence to make a business risk decision on the appropriate resolution. This paper outlines the results of one such engagement with the New York Power Authority (NYPA), where the CyOTE program partnered with an AOO to develop a design specification for a power side channel detector to identify anomalous changes to device load. It describes the goal of developing this capability, the development process, the challenges the technical teams faced and the future steps an AOO will need to take to install and use this detector in its OT environment.

99 GENERAL AND MISCELLANEOUS↗

Construction of Reconfigurable and Polymorphic DNA Origami Assemblies with Coiled‐Coil Patches and Patterns

Abstract DNA origami nanodevices achieve programmable structure and tunable mechanical and dynamic properties by leveraging the sequence‐specific interactions of nucleic acids. Previous advances have also established DNA origami as a useful building block to make well‐defined micron‐scale structures through hierarchical self‐assembly, but these efforts have largely leveraged the structural features of DNA origami. The tunable dynamic and mechanical properties also provide an opportunity to make assemblies with adaptive structures and properties. Here the integration of DNA origami hinge nanodevices and coiled‐coil peptides are reported into hybrid reconfigurable assemblies. With the same dynamic device and peptide interaction, it is made multiple higher‐order assemblies (i.e., polymorphic assembly) by organizing clusters of peptides into patches or arranging single peptides into patterns on the surfaces of DNA origami to control the relative orientation of devices. The coiled‐coil interactions are used to construct circular and linear assemblies whose structure and mechanical properties can be modulated with DNA‐based reconfiguration. Reconfiguration of linear assemblies leads to micron scale motions and ≈2.5‐10‐fold increase in bending stiffness. The results provide a foundation for stimulus‐responsive hybrid assemblies that can adapt their structure and properties in response to nucleic acid, peptide, protein, or other triggers.

59 BASIC BIOLOGICAL SCIENCES↗