Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

NuSTAR J163433-4738.7: A fast X-ray transient in the galactic plane

During hard X-ray observations of the Norma spiral arm region by the Nuclear Spectroscopic Telescope Array (NuSTAR) in 2013 February, a new transient source, NuSTAR J163433-4738.7, was detected at a significance level of 8σ in the 3-10 keV bandpass. The source is consistent with having a constant NuSTAR count rate over a period of 40 ks and is also detected simultaneously by Swift at lower significance. The source is not significantly detected by NuSTAR, Swift, or Chandra in the days before or weeks after the discovery of the transient, indicating that the strong X-ray activity lasted between ∼0.5 and 1.5 days. Near-infrared imaging observations were carried out before and after the X-ray activity, but we are not able to identify the counterpart. The combined NuSTAR and Swift energy spectrum is consistent with a power law with a photon index of Γ=4.1{sub −1.0}{sup +1.5} (90% confidence errors), a blackbody with kT = 1.2 ± 0.3 keV, or a Bremsstrahlung model with kT=3.0{sub −1.2}{sup +2.1} keV. The reduced-χ{sup 2} values for the three models are not significantly different, ranging from 1.23 to 1.44 for 8 degrees of freedom. The spectrum is strongly absorbed with N{sub H}=(2.8{sub −1.4}{sup +2.3})×10{sup 23} cm{sup –2}, (9{sub −7}{sup +15})×10{sup 22} cm{sup –2}, and (1.7{sub −0.9}{sup +1.7})×10{sup 23} cm{sup –2}, for the power-law, blackbody, and Bremsstrahlung models, respectively. Although the high column density could be due to material local to the source, it is consistent with absorption from interstellar material along the line of sight at a distance of 11 kpc, which would indicate an X-ray luminosity >10{sup 34} erg s{sup –1}. Although we do not reach a definitive determination of the nature of NuSTAR J163433-4738.7, we suggest that it may be an unusually bright active binary or a magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

NuSTAR J163433-4738.7: A Fast X-Ray Transient in the Galactic Plane

During hard X-ray observations of the Norma spiral arm region by the Nuclear Spectroscopic Telescope Array (NuSTAR) in 2013 February, a new transient source, NuSTAR J163433-4738.7, was detected at a significance level of 8sigma in the 3-10 keV bandpass. The source is consistent with having a constant NuSTAR count rate over a period of 40 ks and is also detected simultaneously by Swift at lower significance. The source is not significantly detected by NuSTAR, Swift, or Chandra in the days before or weeks after the discovery of the transient, indicating that the strong X-ray activity lasted between approx. 0.5 and 1.5 days. Near-infrared imaging observations were carried out before and after the X-ray activity, but we are not able to identify the counterpart. The combined NuSTAR and Swift energy spectrum is consistent with a power law with a photon index of Gamma = 4.1(+1.5/−1.0) (90% confidence errors), a blackbody with kT = 1.2+/-0.3 keV, or a Bremsstrahlung model with kT = 3.0(+2.1/−1.2) keV. The reduced-χ2 values for the three models are not significantly different, ranging from 1.23 to 1.44 for 8 degrees of freedom. The spectrum is strongly absorbed with NH = (2.8(+2.3/−1.4) × 10(exp23) cm(exp−2), (9(+15 /−7) ) × 10(exp22) cm(exp−2), and (1.7(+1.7/−0.9)) × 10(exp23) cm(exp−2), for the power-law, blackbody, and Bremsstrahlung models, respectively. Although the high column density could be due to material local to the source, it is consistent with absorption from interstellar material along the line of sight at a distance of 11 kpc, which would indicate an X-ray luminosity greater than 10(exp34) erg s(exp−1). Although we do not reach a definitive determination of the nature of NuSTAR J163433-4738.7, we suggest that it may be an unusually bright active binary or a magnetar.

Near-infrared imaging observations↗

Direct Measurement of Light Scattering and Quantum State Preservation from Non-Specular Materials [Slides]

Conclusions from Bidirectional Reflectance Distribution Function (BRDF) Measurements: Mirrors are specular and have consistent reflectance over a range of angles. The measured power of the reflected light was consistent for all power meter positions; Kapton had a similar specular response as the mirror (FWHM), but displayed varying power levels for the different power meter positions (much like the Anodized AI and the Solar Cells); The Solar Cells had very high loss consistent with a material that is supposed to absorb light, but still exhibited specular behavior for FWHM; The Anodized AI had the most diffuse (highest FWHM) reflectance and low BRDF amplitude; Also tried to measure the BRDF Aeroglaze (a common satellite coating) but the power meter was not sensitive enough. To the eye, this material seemed very absorbent and any reflection would be very diffuse.

36 MATERIALS SCIENCE↗

Status of NASA's Advanced Radioisotope Power Conversion Technology Research and Development

NASA s Advanced Radioisotope Power Systems (RPS) development program is funding the advancement of next generation power conversion technologies that will enable future missions that have requirements that can not be met by either the ubiquitous photovoltaic systems or by current Radioisotope Power Systems (RPS). Requirements of advanced radioisotope power systems include high efficiency and high specific power (watts/kilogram) in order to meet mission requirements with less radioisotope fuel and lower mass. Other Advanced RPS development goals include long-life, reliability, and scalability so that these systems can meet requirements for a variety of future space applications including continual operation surface missions, outer-planetary missions, and solar probe. This paper provides an update on the Radioisotope Power Conversion Technology Project which awarded ten Phase I contracts for research and development of a variety of power conversion technologies consisting of Brayton, Stirling, thermoelectrics, and thermophotovoltaics. Three of the contracts continue during the current Phase II in the areas of thermoelectric and Stirling power conversion. The accomplishments to date of the contractors, project plans, and status will be summarized.

Wong, Wayne A.↗

Final Report UCLA-Thermochemical Storage with Anhydrous Ammonia

In ammonia-based thermochemical energy storage (TCES), ammonia is dissociated endothermically as it absorbs solar energy during the daytime. When energy is required, the reverse reaction releases energy to heat a working fluid such as steam, to produce electricity. Ammonia-based TCES has great advantages of simplicity, low cost reactants, and a strong industrial base in the conventional ammonia industry. The concept has been demonstrated over three decades of research at Australian National University, achieving a 24-hour demonstration of a complete system. At the start of this project, three challenges were identified that would have to be addressed to show that the system is technically and economically viable for incorporation into a CSP plant with an advanced, high temperature power block. All three of these challenges have now been addressed: 1. The ammonia synthesis reaction had not, to our knowledge, been carried out at temperatures consistent with modern power blocks (i.e., ~650°C). The technical feasibility of operating a reactor under high-temperature, near-equilibrium conditions was an unknown, and was therefore a technical risk. The project has successfully demonstrated steam heating to 650°C and energy recovery to steam at the 5 kWt level. 2. The ammonia system has a relatively low enthalpy of reaction combined with gas phase reactants. This is not a direct disadvantage since the reactants themselves are low cost. The challenge lies in storing the required volume of reactants cost effectively. Therefore, a second key goal was to show, through techno-economic analysis, that underground storage technologies can be used to store the energy-rich gas at a cost that is consistent with the SunShot cost goal. We have identified two promising technologies for gas storage: storage in salt caverns has an estimated cost of 1(USD)/kWht and storage in drilled shafts could be on the order of 7(USD)/kWht. Together these two options answer the technical challenge associated with storage of gas phase components. 3. While this project is primarily concerned with high-temperature heat recovery and methods to store the gaseous components, it is also important to consider the feasibility of the entire system. Consequently, an additional goal was to perform analysis to show the feasibility of integrating endothermic reactors within a tower receiver. A conceptual design of an ammonia dissociation receiver/reactor has been developed that fits into the same size cylindrical envelope as the molten salt receiver in SAM, and has the same design thermal capacity. The calculated thermal efficiency of this receiver is 94.6%. Thus, this investigation has established the technical feasibility of a surround field tower system using ammonia dissociation. With these challenges addressed, we proceeded to design a full-scale synthesis and heat recovery system. A model was developed and validated by comparison with our experimental data. A parametric study showed, among other things, the importance of using small tube diameters and spacing to enhance heat transfer. Multi-parameter optimization was used to find a design that minimizes the wall material volume. Finally, cost estimation shows that the ammonia system has good prospects of meeting the Sunshot 15(USD)/kWht target: estimated costs of the entire synthesis system for the 220 MWt plant with 6 hours of storage are 13(USD)/kWht using salt cavern storage and 18(USD)/kWht using shaft drilling. Costs per kWht are even lower with more hours of storage. With the established technology of ammonia synthesis as a starting point, the successes of the project have mitigated technical risks associated with high-temperature synthesis reaction, underground storage, and tower receiver design. Estimated costs are less than 15(USD)/kWht with salt cavern storage. It is now possible to map a time line to commercial deployment that is likely to be shorter and less risky than other thermochemical cycles under active investigation. UCLA has filed a patent that protects the new ideas developed during this project. Discussions are ongoing with potential investors with the aim of partnering for further work. As well as immediate improvements and extra work with the existing experimental system, a key goal is to extend it to a small solar-driven project at an early opportunity.

14 SOLAR ENERGY↗

A deep search for faint galaxies associated with very low-redshift C iv absorbers. II. Program design, absorption-line measurements, and absorber statistics

To investigate the evolution of metal-enriched gas over recent cosmic epochs as well as to characterize the diffuse, ionized, metal-enriched circumgalactic medium, we have conducted a blind survey for C iv absorption systems in 89 QSO sightlines observed with the Hubble Space Telescope Cosmic Origins Spectrograph. We have identified 42 absorbers at z < 0.16, comprising the largest uniform blind sample size to date in this redshift range. Our measurements indicate an increasing C iv absorber number density per comoving path length (dN/dX= 7.5 ± 1.1) and modestly increasing mass density relative to the critical density of the universe (Ω{sub C iv} = 10.0 ± 1.5 × 10{sup −8}) from z ∼ 1.5 to the present epoch, consistent with predictions from cosmological hydrodynamical simulations. Furthermore, the data support a functional form for the column density distribution function that deviates from a single power law, also consistent with independent theoretical predictions. As the data also probe heavy element ions in addition to C iv at the same redshifts, we identify, measure, and search for correlations between column densities of these species where components appear to be aligned in velocity. Among these ion–ion correlations, we find evidence for tight correlations between C ii and Si ii, C ii and Si iii, and C iv and Si iv, suggesting that these pairs of species arise in similar ionization conditions. However, the evidence for correlations decreases as the difference in ionization potential increases. Finally, when controlling for observational bias, we find only marginal evidence for a correlation (86.8% likelihood) between the Doppler line width b(C iv) and column density N(C iv).

79 ASTRONOMY AND ASTROPHYSICS↗

SPS solid state antenna power combiner

A concept for a solar power satellite antenna power combiner which utilizes solid state dc-rf converters is described. To avoid the power combining losses associated with circuit hybrids it is proposed that the power from multiple solid state amplifiers be combined by direct coupling of each amplifier's output to the radiating antenna structure. The selected power-combining antenna consists of a printed (metalized) microstrip circuit on a ceramic type dielectric substrate which is backed by a shallow lightweight aluminum cavity which sums the power of four microwave sources. The antenna behaves like two one-half wavelength slot-line antennas coupled together via their common cavity structure. A significant feature of the antenna configuration selected is that the radiated energy is summed to yield a single radiated output phase which represents the average insertion phase of the four power amplifiers. This energy may be sampled and, by comparison with the input signal, one can phase error correct to maintain the insertion phase of all solid state power combining modules at exactly the same value. This insures that the insertion phase of each SPS power combining antenna module is identical. An experiment verification program is described.

Fitzsimmons, G. W.↗

Large Torque Variations in Two Soft Gamma Repeaters

We have monitored the pulse frequencies of the two soft gamma repeaters SGR 1806-20 and SGR 1900+14 through the beginning of year 2001 using primarily Rossi X-ray Timing Explorer Proportional Counter Array observations. In both sources, we observe large changes in the spin-down torque up to a factor of approximately 4, which persist for several months. Using long baseline phase-connected timing solutions as well as the overall frequency histories, we construct torque noise power spectra for each SGR. The power spectrum of each source is very red (power-law slope approximately -3.5). These power spectra are consistent in normalization with some accreting systems, yet much steeper in slope than any known accreting source. To the best of our knowledge, torque noise power spectra with a comparably steep frequency dependence have only been seen in young, glitching radio pulsars (e.g. Vela). The observed changes in spin-down rate do not correlate with burst activity, therefore, the physical mechanisms behind each phenomenon are also likely unrelated. Within the context of the magnetar model, seismic activity cannot account for both the bursts and the long-term torque changes unless the seismically active regions are decoupled from one another.

Woods, Peter M.↗

Performance of the 12 GHz, 200 watt Transmitter Experiment Package for the Hermes Satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The tests were conducted from February 8, 1976 through August 8, 1977. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling wave tube with a multistage depressed collector and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 W and overall efficiency of 50.75% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

ICE Calculator 2.0: Final Report for Phase 1 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPS solid state antenna power combiner

Solid state dc-rf converters offer potential improvements in reliability, mass and low voltage operation, provided that anticipated efficiencies in excess of 80 percent can be realized. Field effect transistors offer the greatest potential in the SPS frequency band at 2.45 GHz. To implement this approach it is essential that means be found to sum the power of many relatively low power solid state sources in a low-loss manner, and that means be provided to properly control the phase of the outputs of the large number of solid state sources required. To avoid the power combining losses associated with circuit hybrids it was proposed that the power from multiple solid state amplifiers be combined by direct coupling of each amplifier's output to the radiating antenna structure. The selected power-combining antenna consists of a unique printed (metalized) microstrip circuit on a ceramic type dielectric substrate which is backed by a shallow lightweight aluminum cavity which sums the power of four microwave sources. The antenna behaves like two one-half wavelength slot-line antennas coupled together via their common cavity structure.

Fitzsimmons, G. W.↗

Performance of the 12GHz, 200 watt transmitter experiment package for the Hermes satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity Traveling Wave Tube (TWT) with a Multistage Depressed Collector (MDC) and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 watts and overall efficiency of 50.75 percent at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

Planck 2013 results. XXI. Power spectrum and high-order statistics of the Planck all-sky Compton parameter map

We have constructed the first all-sky map of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 100 to 857 GHz frequency channel maps from the Planck survey. This map shows an obvious galaxy cluster tSZ signal that is well matched with blindly detected clusters in the Planck SZ catalogue. To characterize the signal in the tSZ map we have computed its angular power spectrum. At large angular scales (&ell; < 60), the major foreground contaminant is the diffuse thermal dust emission. At small angular scales (&ell; > 500) the clustered cosmic infrared background and residual point sources are the major contaminants. These foregrounds are carefully modelled and subtracted. We thus measure the tSZ power spectrum over angular scales 0.17° ≲ θ ≲ 3.0° that were previously unexplored. The measured tSZ power spectrum is consistent with that expected from the Planck catalogue of SZ sources, with clear evidence of additional signal from unresolved clusters and, potentially, diffuse warm baryons. Marginalized band-powers of the Planck tSZ power spectrum and the best-fit model are given. The non-Gaussianity of the Compton parameter map is further characterized by computing its 1D probability distribution function and its bispectrum. The measured tSZ power spectrum and high order statistics are used to place constraints on σ 8 .

79 ASTRONOMY AND ASTROPHYSICS↗

High Power Density Body Heat Energy Harvesting

Thermoelectric generators (TEGs) can convert body heat into electricity, thereby providing a continuous power source for wearable and implantable devices. For wearables, the low fill factor (area occupied by legs over the TEG base area) TEG modules are relevant as they provide large thermal gradient across the legs and require less material, which reduces the cost and weight. However, TEGs with a fill factor below 15% suffer from reduced mechanical robustness; consequently, commercial modules are usually fabricated with a fill factor in the range of 25-50%. In this study, TEG modules with a low and high fill factor are demonstrated and their performance is compared in harvesting body heat. Fabricated modules demonstrate ~80% output power enhancement as compared to commercially available designs, resulting in high power density of up to 35 uW/cm2 in a steady state. This enhanced power is achieved by using two-third less thermoelectric materials in comparison to commercial modules. These results will advance the ongoing development of wearable devices by providing a consistent high specific power density source.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 & 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.

systems integration↗

Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

NASA Glenn Research Center developed a nonnuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASCs), Dual Convertor Controller (DCC) EMs (engineering models) 2 and 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University Applied Physics Laboratory (JHU/APL) to actively control a pair of ASCs. The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS), which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and super-capacitor. A load profile, created based on data from several missions, tested the RPS's and RSIL's ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 volts or exceeded 36 volts. Once operation was verified with the DASCS, the tests were repeated with actual operating ASCs. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.

Controllers↗

CLASS Observation of Polarized Cloud Emission at Millimeter Wavelengths

The dynamic atmosphere imposes challenges to ground-based cosmic microwave background observation, especially for measurements on large angular scales. The hydrometeors in the atmosphere, mostly in the form of clouds, scatter the ambient thermal radiation and are known to be the main linearly polarized source in the atmosphere. This scattering-induced polarization is significantly enhanced for ice clouds due to the alignment of ice crystals under gravity, which are also the most common clouds seen at the millimeter-astronomy sites at high altitudes. This work presents a multifrequency study of cloud polarization observed by the Cosmology Large Angular Scale Surveyor experiment on Cerro Toco in the Atacama Desert of northern Chile, from 2016–2022, at the frequency bands centered around 40, 90, 150, and 220 GHz. Using a machine-learning-assisted cloud classifier, we made connections between the transient polarized emission found in all four frequencies with the clouds imaged by monitoring cameras at the observing site. The polarization angles of the cloud events are found to be mostly 90° from the local meridian, which is consistent with the presence of horizontally aligned ice crystals. The90 and 150 GHz polarization data are consistent with a power law with a spectral index of 3.90±0.06, while an excess/deficit of polarization amplitude is found at 40/220 GHz compared with a Rayleigh scattering spectrum. These results are consistent with Rayleigh-scattering-dominated cloud polarization, with possible effects from supercooled water absorption and/or Mie scattering from a population of large cloud particles that contribute to the220 GHz polarization.

Earth's clouds↗