Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Outages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids

Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. Finally, when addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.

Fan, Lingling [Univ. of South Florida, Tampa, FL (↗

Will Solar Panels Help When the Power Goes Out? Planning for PV Resilience

PV systems, like all energy systems, must chart a difficult course in order to improve resilience. They need to simultaneously withstand extreme conditions that cause grid power disruptions, be configured in a way that allows electricity to be delivered to meet the PV user's needs, and overcome disruptions arising from solar resource intermittency. Certain considerations reveal themselves as key to a PV system's resilience benefits. Choice of hardware is critical, as is site selection for the PV array. Voluminous evidence in a hurricane context demonstrates that durable hardware, properly maintained and sited, leads to PV systems surviving extreme weather with their functionality intact. Structurally weak or poorly maintained PV equipment, on the other hand, has demonstrated failures during extreme weather events. PV system stakeholders should ensure that best practices are followed for hardware procurement and siting. It is also important to understand that PV systems are not one-size-fits-all. While incorporating islanding capabilities and energy storage into the system's electrical topology will typically enhance resilience, the user's needs will determine the optimally resilient conformation of any given system. These factors - appropriate hardware, siting, maintenance, and system design - are the primary drivers of PV resilience. PV systems possess high potential for resilient energy generation due to their distributed, abundant, and free fuel supply, but the technology itself does not inherently lead to resilient outcomes. Realizing PV's potential for resilience requires consideration of these determinative factors.

14 SOLAR ENERGY↗

A Novel Bi-directional AC/DC - DC/AC Wireless Power Transfer System for Grid Support Applications

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This paper presents a novel topology for providing export power applications. Proposed topology can be used for grid (primary)-side of bi-directional wireless power transfer (WPT) systems, mobile energy storage systems (ESSs), and electric vehicle (EV) batteries. The proposed concept here achieves energy transfer between sources by using a hybrid frequency bi-directional ac/dc converter without an additional front-end converter stage compared to the conventional systems. Due to inherent merit of the proposed bi-directional ac/dc converter, ac input with 60 Hz grid frequency can be directly transferred through the wireless coils and can be directly converted to the dc. Results demonstrate the performance and the functionality of the single-phase bi-directional system with the input / output of 110 V ac,rms and 200 V dc at 1 kW power. Full paper will demonstrate the converter operation at 10 kW power level with additional features and control aspects.

Asa, Erdem↗

Improved Evaluation of Large Network Matrices for Linear Power Flow Within Optimization Problems: Preprint

This work discusses methods for evaluating the Power Transfer Distribution Factor (PTDF) and Line Outage Distribution Factor (LODF) matrices by employing sparse linear algebra for large-scale computing applications. These matrices are critical in many power systems applications, such as the Unit Commitment Problem (UC), pre- and post-contingency power flow analysis, and transmission expansion. These matrices are typically dense, which means they require a significant amount of time and memory to be computed for large networks. However, by analyzing the structure of the matrices and their computation method, it is possible to use reduced memory methods based on sparse matrix operations. This paper shows that sparse linear algebra algorithms are faster and require less memory and time than traditional dense approaches. Additionally, we explore the effect of matrix sparsification by eliminating trailing digits on power flow calculations.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Improved Evaluation of Large Network Matrices for Linear Power Flow Within Optimization Problems

This work presents methods for evaluating the Power Transfer Distribution Factor (PTDF) and Line Outage Distribution Factor (LODF) matrices by employing sparse linear algebra for large-scale computing applications. These matrices play a critical role in many power system applications, such as the Unit Commitment Problem (UC), pre- and post-contingency power flow analysis, and transmission expansion. These matrices are typically dense, which means they require a significant amount of time and memory to be computed for large networks. However, by analyzing the structure of the matrices and their computation method, it is possible to use reduced memory methods based on sparse matrix operations. This paper shows that sparse linear algebra algorithms are faster and require less memory and time than traditional dense approaches. Additionally, we explore the effect of matrix sparsification by eliminating trailing digits on power flow calculations.

large scale↗

20-kW Bi-directional Wireless Power Transfer System with Energy Storage System Connectivity

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This study presents a novel way of providing export power using bi-directional wireless power transfer (WPT) systems for ac grid side power and mobile energy storage systems (ESSs) connectivity. The proposed concept here interfaces the EV batteries to the AC grid and also can redirect the power from the stationary ESS to grid, to EV batteries, or both simultaneously; providing the capabilities of an uninterrupted power supply (UPS). Results demonstrate the performance and the functionality of the system with overall efficiencies 93% to 97%, depending on the operating mode.

Onar, Omer↗

Mitigation of Alkali Induced Aerosols

Barr, in partnership with the University of North Dakota, Microbeam Technologies Inc., Envergex LLC, and MLJ Consulting, worked to develop a transformational technology that controls the formation of alkali aerosols found in coal ash. This technology mitigates ash deposition by injecting sorbents into the boiler and capturing volatile species responsible for boiler fouling, the primary cause for boiler outages. In this session, we’ll explore the science behind this technology and see some real-world results of its implementation.

01 COAL, LIGNITE, AND PEAT↗

Update on Mitigation of Aerosol Impacts on Ash Deposition and Emission from Coal Combustion

Barr, in partnership with the University of North Dakota, Microbeam Technologies Inc., Envergex LLC, and MLJ Consulting, worked to develop a transformational technology that controls the formation of alkali aerosols found in coal ash. This technology mitigates ash deposition by injecting sorbents into the boiler and capturing volatile species responsible for boiler fouling, the primary cause for boiler outages. In this session, we’ll explore the science behind this technology and see some real-world results of its implementation.

01 COAL, LIGNITE, AND PEAT↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Final Scientific Technical Report for "Microgrid RD&D and Testing of PIDC and PWD Systems"

Alstom Grid Inc’s (ALSTOM Grid) Research Design and Development (RD&D) project, “Microgrid RD&D and Testing for PIDC and PWD” was conducted in partnership with Philadelphia Industrial Development Corporation (PIDC) in its role as owner’s representative and manager of a vibrant commercial and industrial community, involving critical loads in one of the nation’s largest unregulated, non-military electric distribution systems. PIDC needed to develop solutions to address the planned considerable growth in Distributed Energy Resources (DER) Combined Heat Plan (CHP), Renewables, Distributed Generation (DG), Demand Response (DR) and Storage. In supporting the corporate objective, PIDC needed a new class of control systems for achieving enhanced energy resilience of their critical infrastructure operation during adverse conditions together with carbon emission reduction and optimization of the overall system operation economics through system energy efficiency during normal and emergency operating conditions. Additionally, PIDC anticipated the need to support a new class of commercial agreements with tenants, such as those for Urban Outfitters, for guaranteed one hundred percent (100%) grid resilience and electric power supply in case of utility outage conditions. The project was designed to address the challenges for the commercial & industrial (C&I) communities. But more importantly, the project included development of scalable and replicable solutions intended to target a multitude of the nation’s electric distribution communities. The project researched and developed a fully comprehensive prototype consisting of microgrid operation and control functions including islanding, synchronization and reconnection, protection, voltage, frequency, and power quality management, dispatch, and system resiliency. The project provided the foundation required to significantly enhance the overall national objectives set by the DOE for energy resilience, emission reduction and system energy efficiency improvement, including protection of critical infrastructure and public resources.

14 SOLAR ENERGY↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Fuel Cell Power Plant Initiative: Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA - Volume 1

This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

Veyo, S.E.↗

REopt for Resilient Buildings: Leveraging Energy Efficiency and Distributed Energy Resources for Resilience Solutions

Community resilience hubs are locally identified and community-serving facilities that provide residents year-round access to support resources. During extreme weather, they can reduce the burden on emergency response teams by supplying power before, during, and after grid outages through onsite energy systems. This presentation analyzes how NREL's REopt tool can leverage energy efficiency, distributed generation, and storage resources to ensure critical community facilities are online when they are needed most. We showcase the tool's capabilities and application through a case study that focuses on achieving resilience for critical facilities in Manatee County.

better buildings↗

Enhanced Long-Duration Energy Storage Modeling [Slides]

As our power grid evolves toward a more renewable future, energy storage is poised to take a larger role in meeting growing energy needs. Energy storage could help keep the power system reliable even through potential outages, periods of extreme weather, and when generation from variable renewable technologies like wind and solar is low. Given the different durations of these stressors, grid analysts at the National Renewable Energy Laboratory (NREL) are working to better understand the role and benefits of long-duration energy storage - or storage technologies with 8-24 hours of storage capacity - in high variable renewable energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗