Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-204: Improving Multiple Isocenter Coincidence: Elekta Beam Modulator with HexaPOD Six Degrees Couchtop

Purpose: With evolution from frame-based to image-guided SRS/SRT technique, the coincidence of multiple isocenters must be within a tight tolerance: MV, kV, table mechanical, and, in this case, HexaPOD 6° patient positioning system. Reported here is a method for improving the effectiveness of an isocenter alignment procedure which ultimately led to isocenter coincidence on an Elekta Beam Modulator LINAC equipped with 4 mm MLC leaves and a fixed secondary jaw to within a radius of 1mm. Methods: Utilizing a self-leveling laser, the Elekta ball (BB) bearing phantom (8mm steel ball), the Modus QA Isocenter Cube software, and a colleague-provided isocenter alignment method, the kV, table mechanical, and HexaPOD isocenters were localized to the MV isocenter. Isocenter coincidence was tested using the Isocenter Cube from Modus QA, brought to kV isocenter using CBCT and the HexaPOD system. MV images were taken at various gantry, collimator, and couch angles and then analyzed with the aforementioned software to determine coincidence of the 5mm steel ball at cube center with MV isocenter. To improve overall coincidence, two errors were addressed iteratively: (1) LINAC mechanical and radiation isocenter coincidence allowing each isocenter volume to have similar variations during gantry and collimator rotation and (2) collimator rotational walkout which reduced the size of both mechanical and radiation isocenters. Beam steering was performed to bring MV isocenter closer to mechanical and collimator walkout was adjusted by physically shifting the MLC bank. Initial procedures were repeated to align all isocenters and perform regular checks for consistency. Results: Post-initial alignment revealed a maximum diameter of 1.8mm for MV isocenter and maximum isocenter alignment error of up to 1.22mm radius which improved to roughly 1.0mm MV isocenter diameter and <0.71mm radius alignment error with a consistency within 0.25mm. Conclusion: With the methods described, all isocenters were brought into alignment within a radius of 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-BRD-06: Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors

Purpose: To evaluate the performance characteristics of plastic scintillation detectors (PSDs) in an in vivo environment for external beam radiation, and to establish the usefulness and ease of implementation of a PSD based in vivo dosimetry system for routine clinical use. Methods: A five patient IRB approved in vivo dosimetry study was performed. Five patients with prostate cancer were enrolled and PSDs were used to monitor rectal wall dose and verify the delivered dose for approximately two fractions each week over the course of their treatment (approximately fourteen fractions), resulting in a total of 142 in vivo measurements. A set of two PSDs was fabricated for each patient. At each monitored fraction the PSDs were attached to the anterior surface of an endorectal balloon used to immobilize the patient's prostate during treatment. A CT scan was acquired with a CTon- rails linear accelerator to localize the detectors and to calculate the dose expected to be delivered to the detectors. Each PSD acquired data in 10 second intervals for the duration of the treatment. The deviation between expected and measured cumulative dose was calculated for each detector for each fraction, and averaged over each patient and the patient population as a whole. Results: The average difference between expected dose and measured dose ranged from -3.3% to 3.3% for individual patients, with standard deviations between 5.6% and 7.1% for four of the patients. The average difference for the entire population was -0.4% with a standard deviation of 2.8%. The detectors were well tolerated by the patients and the system did not interrupt the clinical workflow. Conclusion: PSDs perform well as in vivo dosimeters, exhibiting good accuracy and precision. This, combined with the practicability of using such a system, positions the PSD as a strong candidate for clinical in vivo dosimetry in the future. This work supported in part by the National Cancer Institute through an R01 grant (CA120198-01A2) and by the American Legion Auxiliary through the American Auxiliary Fellowship in Cancer Research.

60 APPLIED LIFE SCIENCES↗

SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetry was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.

60 APPLIED LIFE SCIENCES↗

Tracking the weight of Hurricane Harvey’s stormwater using GPS data

On 26 August 2017, Hurricane Harvey struck the Gulf Coast as a category four cyclone depositing ~95 km 3 of water, making it the wettest cyclone in U.S. history. Water left in Harvey’s wake should cause elastic loading and subsidence of Earth’s crust, and uplift as it drains into the ocean and evaporates. To track daily changes of transient water storage, we use Global Positioning System (GPS) measurements, finding a clear migration of subsidence (up to 21 mm) and horizontal motion (up to 4 mm) across the Gulf Coast, followed by gradual uplift over a 5-week period. Inversion of these data shows that a third of Harvey’s total stormwater was captured on land (25.7 ± 3.0 km 3 ), indicating that the rest drained rapidly into the ocean at a rate of 8.2 km 3 /day, with the remaining stored water gradually lost over the following 5 weeks at ~1 km 3 /day, primarily by evapotranspiration. These results indicate that GPS networks can remotely track the spatial extent and daily evolution of terrestrial water storage following transient, extreme precipitation events, with implications for improving operational flood forecasts and understanding the response of drainage systems to large influxes of water.

54 ENVIRONMENTAL SCIENCES↗

Seasonal water storage, stress modulation, and California seismicity

Establishing what controls the timing of earthquakes is fundamental to understanding the nature of the earthquake cycle and critical to determining time-dependent earthquake hazard. Seasonal loading provides a natural laboratory to explore the crustal response to a quantifiable transient force. In California, water storage deforms the crust as snow and water accumulates during the wet winter months. Here, we used 9 years of global positioning system (GPS) vertical deformation time series to constrain models of monthly hydrospheric loading and the resulting stress changes on fault planes of small earthquakes.The seasonal loading analysis reveals earthquakes occurring more frequently during stress conditions that favor earthquake rupture.We infer that California seismicity rates are modestly modulated by natural hydrological loading cycles.

58 GEOSCIENCES↗

Atmospheric ultraviolet and red-infrared flashes from Universitetsky-Tatiana-2 satellite data

Millisecond ultraviolet (240-400 nm) and red-infrared (610-800 nm) flashes were detected in the nighttime atmosphere with the scientific payload installed onboard the Universitetsky-Tatiana-2 micro-satellite. Flashes with various numbers of photons, from 10{sup 20} to 10{sup 26}, were detected within the atmospheric area 300 km in diameter observed by the detector. The flashes differ in duration and temporal profile: from single short flashes {approx}1 ms in duration to flashes with a complex profile more than 100 ms in duration. Different global geographic distributions are observed for flashes with different numbers of photons. Flashes with fewer than 10{sup 22} photons are distributed uniformly over the Earth's map. Flashes with more than 10{sup 22} photons are concentrated near the equator and above the continents. Series of flashes were observed in one turn of the satellite when flying not only over thunderstorm regions but also over cloudless ones. The flash number distribution has been derived from the ratio of the numbers of red-infrared and ultraviolet photons. As applied to discharges in the upper atmosphere, whose glow is dominated by the emission in the first and second positive systems of molecular nitrogen bands (1PN{sub 2} and 2PN{sub 2}), this distribution is equivalent to the flash altitude distribution in the atmosphere. The observed ratio of the numbers of photons in red-infrared and ultraviolet flashes agrees with the calculated one for electric discharges at altitudes higher than 50 km. In-orbit measurements of the charged particle flux (with a threshold energy for electrons of 1 MeV) provide no evidence for a synchronous occurrence of an ultraviolet flash and a burst in the particle flux in the orbit.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microwave electrode discharge in nitrogen: Structure and characteristics of the electrode region

The parameters of the electrode region of an electrode microwave discharge in nitrogen are studied by emission spectroscopy. The radial and axial distributions of the intensities of the bands of the second (N{sub 2}(C{sup 3{Pi}}{sub u} {sup {yields}}B{sup 3{Pi}}{sub g})) and first (N{sub 2}(B{sup 3{Pi}}{sub g} {sup {yields}}A{sup 3{Sigma}}{sub u}{sup +})) positive systems of molecular nitrogen and the first negative system of nitrogen ions (N{sub 2}{sup +} (B{sup 2{Sigma}}{sub u}{sup +} {sup {yields}}X{sup 2{Sigma}}{sub g}{sup +})), the radial profiles of the electric field E and the electron density N{sub e}, and the absolute populations of the vibrational levels v{sub C} = 0-4 of the C{sup 3{Pi}}{sub u} excited state of N{sub 2} and the vibrational level v{sub Bi} = 0 of the B{sup 2{Sigma}}{sub u}{sup +} excited state of a molecular nitrogen ion are determined. The population temperature of the first vibrational level T{sub V} of the ground electronic state X{sup 1{Sigma}}{sub g}{sup +} of N{sub 2} and the excitation temperature T{sub C} of the C{sup 3{Pi}}{sub u} state in the electrode region of the discharge are measured. The radius of the spherical region and the spatially integrated plasma emission spectra are studied as functions of the incident microwave power and gas pressure. A method for determining the electron density and the microwave field strength from the plasma emission characteristics is described in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specific features of radiation from a negative air corona operating in the Trichel-pulse mode

Experimental studies of spatiotemporal characteristics of radiation from a negative corona operating in the Trichel-pulse mode in the point-to-sphere electrode geometry have revealed two emission zones. In addition to the well-known glow near the point electrode, there is also an anode glow, whose intensity depends substantially on the shape of the anode. It is found that the anode glow is delayed with respect to the beginning of the Trichel pulse by a time that depends on the gap length and gap voltage. The emission spectrum of the anode glow in the wavelength range 300-400 nm is identified as the spectrum of the second positive system of nitrogen (the C{sup 3{Pi}}{sub u}-B{sup 3{Pi}}{sub g} transition).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Similarity laws for cathode-directed streamers in gaps with an inhomogeneous field at elevated air pressures

Results are presented from experimental studies of cathode-directed streamers in the gap closure regime without a transition into spark breakdown. Spatiotemporal, electrodynamic, and spectroscopic characteristics of streamer discharges in air at different pressures were studied. Similarity laws for streamer discharges were formulated. These laws allow one to compare the discharge current characteristics and streamer propagation dynamics at different pressures. Substantial influence of gas photoionization on the deviations from the similarity laws was revealed. The existence of a pressure range in which the discharges develop in a similar way was demonstrated experimentally. In particular, for fixed values of the product pd and discharge voltage U, the average streamer velocity is also fixed. It is found that, although the similarity laws are violated in the interstreamer pause of the discharge, the average discharge current and the product of the pressure and the streamer repetition period remain the same at different pressures. The radiation spectra of the second positive system of nitrogen (the C{sup 3{Pi}}{sub u}-B{sup 3{Pi}}{sub g} transitions) in a wavelength range of 300-400 nm at air pressures of 1-3 atm were recorded. It is shown that, in the entire pressure range under study, the profiles of the observed radiation bands practically remain unchanged and the relative intensities of the spectral lines corresponding to the {sup 3{Pi}}{sub u}-B{sup 3{Pi}}{sub g} transitions are preserved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Population of the Metastable A{sup 3}Σ{sub u} State of Molecular Nitrogen under Conditions of Plasma Chemical Synthesis of Metal Nitrides

The absolute population of the B{sup 3}Π{sub g} state of molecular nitrogen is calculated from the intensity of electron-vibrational bands of the first positive system. The absolute population of the metastable A{sup 3}Σ{sub u} state of nitrogen molecules is calculated based on the solution of the balance equation. It is established that the population of the metastable state of molecular nitrogen increases with a decrease in the pressure and increase in the current intensity of the glow discharge. The results of determining the population of the A{sup 3}Σ{sub u} state of nitrogen molecules under conditions of simultaneous excitation of glow and vacuum arc discharges are presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

The nature and origins of decametre-scale porosity in Ordovician carbonate rocks, Halahatang oilfield, Tarim Basin, China

At >7 km depths in the Tarim Basin, hydrocarbon reservoirs in Ordovician rocks of the Yijianfang Formation contain large cavities ( c . 10 m or more), vugs, fractures and porous fault rocks. Although some Yijianfang Formation outcrops contain shallow (formed near surface) palaeokarst features, cores from the Halahatang oilfield lack penetrative palaeokarst evidence. Outcrop palaeokarst cavities and opening-mode fractures are mostly mineral filled but some show evidence of secondary dissolution and fault rocks are locally highly ( c . 30%) porous. Cores contain textural evidence of repeated formation of dissolution cavities and subsequent filling by cement. Calcite isotopic analyses indicate depths between c . 220 and 2000 m. Correlation of core and image logs shows abundant cement-filled vugs associated with decametre-scale fractured zones with open cavities that host hydrocarbons. A Sm–Nd isochron age of 400 ± 37 Ma for fracture-filling fluorite indicates that cavities in core formed and were partially cemented prior to the Carboniferous, predating Permian oil emplacement. Repeated creation and filling of vugs, timing constraints and the association of vugs with large cavities suggest dissolution related to fractures and faults. In the current high-strain-rate regime, corroborated by velocity gradient tensor analysis of global positioning system (GPS) data, rapid horizontal extension could promote connection of porous and/or solution-enlarged fault rock, fractures and cavities. Supplementary material: Stable isotopic analyses and the velocity gradient tensor and principal direction and magnitude calculation are available at https://doi.org/10.6084/m9.figshare.c.4946046 Thematic collection: This article is part of the The Geology of Fractured Reservoirs collection available at: https://www.lyellcollection.org/cc/the-geology-of-fractured-reservoirs

Geology↗

Prediction of Individual Social-Demographic Role Based on Travel Behavior Variability Using Long-Term GPS Data

With the development of and advances in smartphones and global positioning system (GPS) devices, travelers’ long-term travel behaviors are not impossible to obtain. This study investigates the pattern of individual travel behavior and its correlation with social-demographic features. For different social-demographic groups (e.g., full-time employees and students), the individual travel behavior may have specific temporal-spatial-mobile constraints. The study first extracts the home-based tours, including Home-to-Home and Home-to-Non-Home, from long-term raw GPS data. The travel behavior pattern is then delineated by home-based tour features, such as departure time, destination location entropy, travel time, and driving time ratio. The travel behavior variability describes the variances of travelers’ activity behavior features for an extended period. After that, the variability pattern of an individual’s travel behavior is used for estimating the individual’s social-demographic information, such as social-demographic role, by a supervised learning approach, support vector machine. In this study, a long-term (18-month) recorded GPS data set from Puget Sound Regional Council is used. The experiment’s result is very promising. The sensitivity analysis shows that as the number of tours thresholds increases, the variability of most travel behavior features converges, while the prediction performance may not change for the fixed test data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Location Generalizer

This software produces general location descriptions from time-series location data collected from mobile devices that record global positioning system (GPS) coordinates over time. The purpose of this software is to convert detailed location history data, which is considered personally identifiable information (PII), into non-traceable, anonymized, generic information that is useful to researchers but does not contain PII. The software is specifically designed for use with trigger-based data that describe the parked locations and dwell times of automobiles.

Smart, John↗

Coupled Approximation of U.S. Driving Speed and Volume Statistics using Spatial Conflation and Temporal Disaggregation

The advent of mobile devices with embedded global positioning systems has allowed commercial providers of real-time traffic data to develop highly accurate estimates of network-level vehicle speeds. Traffic speed data have far outpaced the availability and accuracy of real-time traffic volume information. Limited to a relatively small number of permanent and temporary traffic counters in any city, traffic volumes typically only cover a handful of roadways, with inconsistent temporal resolution. This work addressed this data gap by coupling a commercial data set of typical traffic speeds (by roadway and time of week) from TomTom to the U.S. Federal Highway Administration's Highway Performance Monitoring System database of annual average daily traffic (AADT) counts by roadway. This work is technically novel in its solution for establishing a national crosswalk between independent network geometries using spatial conflation and big data techniques. The resulting product is a national data set providing traffic speed and volume estimates under typical conditions for all U.S. roadways with AADT values.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamically Collected Local Density using Low-Cost Lidar and its Application to Traffic Models

This article demonstrates the use of traffic density observations collected dynamically in the vicinity of probe vehicles. Fixed position sensors cannot capture the longitudinal evolution of local traffic density in the corridor. In this research, dynamic traffic density observations were collected in a naturalistic driving setting that was free of any controlled experiment biases. Speed from global positioning system and space headway from a light detection and ranging module was collected on one arterial and one freeway segment, 2 and 4mi long, respectively. The combined data frequency was approximately 3Hz. Space headway was used to estimate the local density and consequently to identify the density of a specific location in a corridor. Besides, driver behavior was characterized using the relationship between instantaneous speed and local density under different regimes of the Wiedemann car-following model. Macroscopic traffic stream models were used to investigate the relationship between dynamically collected instantaneous speed and local density. Using the longitudinal evolution of density, precise local density across the corridor can be obtained along with the leader and follower trajectories. A method to identify driver behavior across density ranges was developed for different facility types using a microscopic relationship between instantaneous speed and local density. Overall driving behavior on the freeway segment can be represented by translating the instantaneous speed and local density relationship to macroscopic stream models.

Engineering↗

Evaluating the Interplay between Trajectory Segmentation and Mode Inference Error

Travel behavior changes are essential to transportation decarbonization. Travel diaries, consisting of sequences of trips between places, are typically used to instrument human travel behavior. However, these diaries are only as accurate as the underlying methods used to construct them. Travel diary algorithms have been a popular research topic since the advent of Global Positioning System tracking surveys. These algorithms have typically been validated using prompted recall of presegmented trips, thus disregarding the continuity of mode inference. Phone operating systems have adopted battery-conserving techniques, but the resulting data collection errors have not been studied extensively. We introduce a framework to evaluate the accuracy of trip length computations and mode inference by analyzing continuous mode-segmented trajectories for groups of trips. We then use the framework to identify the input data quality and the impact of postprocessing. Our primary inputs to this evaluation are MobilityNet, a public dataset containing information from three artificial timelines covering 15 different travel modes, and sample open-source travel diary creation algorithms from the OpenPATH project. Our framework concretely shows that the variance of the distance error drops from (0.217, 0.0848) to (o.011, 0.0407) (Android, iOS) after postprocessing. Similarly, the weighted F-scores for mode inference increase from (0.25, 0.29) to (0.60, 0.74) (iOS, Android) between random forest and geographic information system-based models. We hope that this standardized method will be adapted to evaluate other, potentially proprietary, travel diary algorithms. Finally, the results can be used to understand and improve the state of the art in the travel diary creation field.

33 ADVANCED PROPULSION SYSTEMS↗