Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physical Security Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Cyber Physical Security (CPS) Extension to Air Traffic Management (ATM) Testbed

The Air Traffic Management (ATM) Testbed is being developed at NASA to enable benefit, impact, safety and cost assessments for accelerating the deployment of Concept and Technologies (C&T) in the National Airspace System (NAS). Today, C&T introduction into the NAS takes decades. The primary reason for this is an inability to assess the operational impact of the interaction between the proposed C&T and operationally deployed systems (Realistic Technologies) in terms of NAS-wide safety, traffic flow efficiency, roles and workload of controllers and traffic managers, and impact on airline fleet operations. Transition of C&T to operations requires mathematical modeling and simulation, Human-in-the-Loop (HITL) testing and shadow-mode evaluation driven by operational data. Whereas interaction with the operational system during testing and stages of deployment is not permissible due to safety concerns, it is certainly possible to create a simulation environment that closely mimics the NAS using the same operational systems/hardware for enabling such assessments. This presentation focuses on a proposed Cyber Physical Security extension to the ATM Testbed for creating a modeling and simulation architecture to study how well the Air Traffic Management system will perform and analyze effectiveness of mitigating security measures against particular cyber-attack scenarios.

Datta, Koushik↗

ARCADES: analysis of risk from cyberattack against defensive strategies for the power grid

In this study, the authors introduce ARCADES (Analysis of Risk from Cyberattack against DEfensive Strategy), a technique to systematically explore the cybersecurity defence strategies based on contingency rankings in power systems. While cybersecurity defensive standards exist, these approaches are primarily based on expert opinions, rather than systematic studies of risk. ARCADES presents an approach to identify improved cybersecurity defensive strategies based on a graph‐based cyber‐physical security model that is evaluated by resistance‐distance metrics and then prioritised based on contingency analysis studies of the system. This study also proposed a technique that identifies the most critical cybersecurity mechanisms to protect the power grid. Planning and operation: those two applications for cybersecurity on power grid mainly explored in this study. For planning, a systematic method is developed to verify the effectiveness of security strategies and for operation, prioritised the security mechanism for auditing and monitoring purpose. As a case study, they analyse the IEEE‐14 bus, IEEE‐30 bus, and IEEE‐118 bus systems, observe the defensive strategies, and calculate substation criticality ranking by using the authors’ proposed method.

Touhiduzzaman, Md↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Development of a Commercially Viable, Modular Autonomous Robotic Systems for Converting any Vehicle to Autonomous Control

A Modular Autonomous Robotic System (MARS), consisting of a modular autonomous vehicle control system that can be retrofit on to any vehicle to convert it to autonomous control and support a modular payload for multiple applications is being developed. The MARS design is scalable, reconfigurable, and cost effective due to the use of modern open system architecture design methodologies, including serial control bus technology to simplify system wiring and enhance scalability. The design is augmented with modular, object oriented (C++) software implementing a hierarchy of five levels of control including teleoperated, continuous guidepath following, periodic guidepath following, absolute position autonomous navigation, and relative position autonomous navigation. The present effort is focused on producing a system that is commercially viable for routine autonomous patrolling of known, semistructured environments, like environmental monitoring of chemical and petroleum refineries, exterior physical security and surveillance, perimeter patrolling, and intrafacility transport applications.

guidepath position navigation control system↗

Southeastern Power Administration 2007 Annual Report

Dear Secretary Chu: I am proud to submit Southeastern Power Administration’s (Southeastern’s) fiscal year (FY) 2007 Annual Report for your review. The information included in this report reflects Southeastern’s programs, accomplishments, and financial activities for the 12-month period beginning October 1, 2006 and ending September 30, 2007. Southeastern marketed more than 5 billion kilowatt-hours of energy to 492 wholesale Federal power customers in an 11-state marketing area in FY 2007. Revenues from the sale of this power totaled approximately $219 million. Drought conditions continued to plague the southeast region of the United States during 2007 placing strains on our natural and financial resources. Southeastern purchased more than $40 million in replacement power to meet customer contract requirements to ensure the continued reliability of our nation’s power grid. With the financial assistance and support of our Federal power customers, continued funding for capitalized equipment replacements at various Corps of Engineers’ (Corps) hydroelectric projects provided much needed repairs and maintenance for aging facilities. Southeastern’s cyber and physical security program continued to be reviewed and updated to meet Department of Energy (DOE), Homeland Security, and North American Electric Reliability Corporation standards and requirements. Plans for the upcoming year include communication and cooperation with DOE, Federal power customers, and the Corps to maximize the benefits of our nation’s water resources. Competition for the use of water and the prolonged drought conditions will present another challenging year for our agency. The employees at Southeastern will be proactive in meeting these challenges and providing reliable hydroelectric power to the people in the southeast. Sincerely, Kenneth E. Legg Administrator

2007↗

A High-Fidelity Cyber-Physical Testbed-Based Benchmarking Dataset For Testing Operational Technology Specific Intrusion Detection Systems

Quality datasets serve a critical purpose in cyber security research. Data is needed to understand system behavior and develop security controls to protect critical systems. However, for critical infrastructure operational environments there is a lack of available datasets to study because of the high cost and specialized capabilities necessary to generate them. This paper documents the development of a dataset of high fidelity hardware in the loop laboratory simulated models of electric and natural gas distribution systems with real cyber attack test cases. A deep dive discussion for the experimental setup and controls for generating the data is provided along with observations from using the data in evaluating intrusion detection approaches.

Ashok, Aditya↗

Cyber100 Compass: Quantification of Cybersecurity Risks for Systems Transitioning to High Levels of Renewables (Final Report)

The shift to high levels of renewable deployment will entail a significant re-engineering of the grid. As investors, utilities, customers, and others prepare for clean energy transitions, there is need to understand how restructuring the grid to accommodate renewables will change the attack surface of the grid and accompanying cyber risk. However, today the cyber-physical risks associated with electric grids incorporating high levels of renewable deployment remain largely unknown. The Cyber100 Compass proof-of-concept application attempts to quantify future cyber-physical security risks by combining risk data gathered from subject matter experts (SMEs) with input from system planners about conditions they expect to be true about their electric systems in the future. Users provide data about their organization’s tolerance for risk; the value they place on avoiding the consequences of different cyber events; and conditions that they expect to be true on their systems at some point in the future. The SMEs provide baseline probabilities for different cyber events; the probability that an event will be low-, moderate-, or high-impact; and the amount by which user-identified conditions on their systems will change the likelihood of the cyber events. The application takes both the user and SME input and performs a series of Monte Carlo simulations to arrive at a quantification of risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-based Hierarchical Reinforcement Learning for Improved Physical Security Design: A Prototype

Prior work in FY24 developed an adversarial AI agent aid in path analysis of physical protection systems. This agent, trained using a model-based reinforcement learning algorithm, was able to successfully learn the most vulnerable path in facilities. It was able to extend the current state of practice for physical protection design by exhibiting dynamic behavior based on current environmental conditions. Whereas PathTrace largely performs a static, graph-based analysis, the AI agent was able to make decisions based on relative position in the facility, current conditions (was the adversarial agnet discovered?), and proximity to secondary targets. The agent demonstrated some novel capabilities, but had limitations that need to be resolved before it can be used for production purposes. For example, the adversarial agent generalizes poorly and takes a relatively long time to train. Nonetheless, there is still considerable promise for developing the adversarial agent further in order to explore even richer, more dynamic behaviors (e.g., adversary motivations, environmental debris, and more). This work considers a complementary idea; development of a planning agent. The planning agent is envisioned as an auto-complete-like tool that can help accelerate security system design by human experts. The agent would respect existing barriers and sensors placed by a human expert while offering cost-effective suggestions (i.e., implicitly balancing effectiveness with cost) to improve the design. The goal is for this agent to be part of an expert’s toolbox, not to totally upend the current state-of-practice, or to displace human experts. The ultimate goal would be concurrent training of both the adversarial and planning agent together, to learn entirely through self-play. This would represent an entirely new way of performing system deign. We selected a hierarchical, model-based reinforcement learning algorithm to serve as the planning agent. This is an extension of concepts used in the prior FY24 adversarial agent work. There, we had a single agent acting an environment. Here, we have two different sub-agents (policies), working together, to form a complete agent. There is a manager policy, which can select abstract goals on slower time scales, and a worker, which performs primitive actions to reach goals selected by the manager. It is worth noting that this class of algorithm is challenging to work with. From our understanding, our work is one of the first successful uses of model-based reinforcement learning (MBRL) in nuclear energy1 , and likely the first hierarchical model-based reinforcement learning application in nuclear energy. Further, this work is one of the first known attempts to apply AI to perform a design tasks in nuclear energy. Consequently, there were significant implementation challenges and the bulk of the work was focused on successful implementation and algorithm design. The results presented here are very low technology readiness level as a consequence of the lack of related literature, but still represent a significant step forward in the pursuit of applied AI for design.

42 ENGINEERING↗

Simulation and Modeling Concepts for Secure Airspace Operations

With the expected advent of new entrants including Unmanned Aerial Systems, Commercial Launch Vehicles and Urban Air Mobility aircraft, the future United States National Airspace System will have to evolve to include their operations along with the current commercial, general aviation and military operations. The National Aeronautics and Space Administration and the Federal Aviation Administration are working together to provide a vision for aviation operations in the future—2045 and beyond. Their National Airspace System Horizons initiative seeks to provide stakeholders a list of operational scenarios and technologies, concepts and strategies needed for supporting that vision. They have identified cybersecurity as one of the seven strategic interest areas for realizing this vision. Consequently, NASA is studying cyber resiliency for secure airspace operations. This paper examines cyber security vulnerabilities of Urban Air Mobility operations. While there are many pathways to attack a cyber physical system such as Urban Air Mobility, their effect is expressed in modification or corruption of data/information used for controlling vehicles and making operational decisions. The paper describes cybersecurity technologies of Encryption, Blockchain, Virtual Information Fabric Infrastructure, Trusted Platform Module and Anomaly Detection for protecting the data, thus, improving the cyber resiliency of the current and future air traffic management system.

Cybersecurity↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Simulated, Emulated, and Physical Investigative Analysis (SEPIA) of networked systems.

This report describes recent progress made in developing and utilizing hybrid Simulated, Emulated, and Physical Investigative Analysis (SEPIA) environments. Many organizations require advanced tools to analyze their information system's security, reliability, and resilience against cyber attack. Today's security analysis utilize real systems such as computers, network routers and other network equipment, computer emulations (e.g., virtual machines) and simulation models separately to analyze interplay between threats and safeguards. In contrast, this work developed new methods to combine these three approaches to provide integrated hybrid SEPIA environments. Our SEPIA environments enable an analyst to rapidly configure hybrid environments to pass network traffic and perform, from the outside, like real networks. This provides higher fidelity representations of key network nodes while still leveraging the scalability and cost advantages of simulation tools. The result is to rapidly produce large yet relatively low-cost multi-fidelity SEPIA networks of computers and routers that let analysts quickly investigate threats and test protection approaches.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Basic Energy Sciences Roundtable: Foundational Science for Carbon Dioxide Removal Technologies (Brochure)

Basic research to identify and understand the fundamental principles governing carbon dioxide removal processes of capture, conversion, and storage is essential for achieving zero carbon emissions by 2050. In March 2022, the Office of Basic Energy Sciences (BES)—in coordination with the US Department of Energy (DOE) technology Offices of Energy Efficiency and Renewable Energy, Fossil Energy and Carbon Management, and Nuclear Energy—held a roundtable titled, “Foundational Science for Carbon Dioxide Removal Technologies,” to discuss the scientific and technical barriers for CO 2 capture, conversion, and storage. Five priority research opportunities were identified to address these scientific and technical challenges and accelerate progress toward the realization of zero carbon emissions. The PROs are as follows: 1) Master Interfacial Processes of CO2 Transport and Reactivity Across Multiple Length and Time Scales; 2) Create Materials that Simultaneously Exhibit Multiple Properties for CO 2 Capture and Release or Conversion; 3) Discover Unconventional Pathways for Energy-Efficient CO 2 Capture, Release, and Conversion; 4) Control Multiphase Interactions Required for CO 2 Conversion into Minerals and Materials; and 5) Achieve Predictive Understanding of Coupled Processes in Complex Subsurface Geologic Systems for Secure Carbon Storage.

36 MATERIALS SCIENCE↗

Engineering Controls Database

Cyber-Informed Engineering (CIE) addresses the reality that cyber attacks on engineered systems can have consequences far beyond data loss or disruption of digital networks. When control systems are compromised, safety, reliability, and performance of the physical process itself may be threatened. This database is meant to establish clear examples and guidance for defining and applying engineered controls in CIE. It explains what engineered controls are, how they differ from information security measures, and how they are integrated into system design. The goal is to ensure that resilience is engineered into systems from the outset. Unlike cybersecurity protections that defend the digital layer, engineered controls act directly at the physical and algorithmic levels to guarantee that unacceptable consequences are prevented or limited. CIE keeps the consequences of a cyber attack from impacting the safety, reliability, and performance of engineered systems.

Source record↗

Cyber-Informed Engineering (CIE) – Engineered Controls Database and Use

Cyber-Informed Engineering (CIE) addresses the reality that cyber-attacks on engineered systems can have consequences far beyond data loss or disruption of digital networks. When control systems are compromised, safety, reliability, and performance of the physical process itself may be threatened. This database is meant to establish clear examples and guidance for defining and applying engineered controls in CIE. It explains what engineered controls are, how they differ from information security measures, and how they are integrated into system design. The goal is to ensure that resilience is engineered into systems from the outset. Unlike cybersecurity protections that defend the digital layer, engineered controls act directly at the physical and algorithmic levels to guarantee that unacceptable consequences are prevented or limited. CIE keeps the consequences of a cyber attack from impacting the safety, reliability, and performance of engineered systems.

42 - ENGINEERING↗

Implications of the 2015 and 2016 Ukrainian electric grid cyber attacks to nuclear power plants - 113

Nuclear plants can be vulnerable from electric grid cyber attacks. In December 2015 and December 2016, cyber attackers attacked the Ukrainian electric grid and 'turned off the lights' by opening substation protective relays. The 2015 cyber attacks targeted electric distribution systems and the 2016 cyber attacks targeted electric transmission systems. In order to accomplish the attacks, the cyber attackers compromised field control system devices to inject malware and then open protective relays in substations. There are some very significant implications to nuclear plant operations from hacking the substations and switchyard breakers that serve nuclear plants. The nuclear plant operational concerns are compromising protective relays to prevent relay protection that would result in damage to large electric equipment; spurious actuation of protective relays causing loss-of-offsite power (LOOP) conditions; and the closing and then reopening of protective relays out-of-phase with the grid causing the Aurora vulnerability damaging generators, Alternating Current (AC) motors, and transformers. All of these protective relay conditions have already occurred in actual or test conditions. The common thread to these scenarios are that switchyard and substation protective relays are out-of-scope of existing nuclear cyber security regulations yet, when compromised, have demonstrated impacts to nuclear plant operations and challenged safety systems. There is one other issue about an attack originating from a protective relay. That is, it would be irrelevant whether the nuclear plant system that would be impacted would have analog or digital instrumentation and control (I and C) systems because the impact is upstream of the I and C. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proactive Intrusion Detection and Mitigation System

SAND2023-05661O The proactive intrusion detection and mitigation system (PIDMS) provides grid-edge situational awareness for cybersecurity defense by capturing real-time distributed energy resource (DER) network traffic and performance data with a novel approach that improves the detection and prevention of cyber-physical attacks. The PIDMS addresses the grid-edge security gap with real-time analysis of both network traffic and photovoltaic performance data to deliver a novel, cyber-physical intrusion detection system (IDS) approach that increases the accuracy and effectiveness of detection and mitigation. This hybrid IDS analysis enables dual monitoring that increases the workload of the adversary; both cyber and physical data would have to be simultaneously spoofed to evade detection. Furthermore, monitoring and analyzing cyber data are insufficient in some cases. For example, in an insider threat aimed at disrupting inverter grid-support functions where proper credentials and authentication are achieved, only the altered PV performance would indicate abnormal behavior. All in all, the PIDMS provides novel capabilities for: • Distributed, real-time cyber-physical detection and mitigation analysis • Cybersecurity defense for grid-edge systems • Analysis framework that can provide situational awareness across the transmission, distribution, and DER systems The PIDMS sensor is designed to collect cyber-physical data, process the data using machine-learning algorithms, detect abnormal events, and deploy mitigations. With these goals, the main functional PIDMS objectives are: • Capability to collect cyber-physical data • Onboard storage of cyber-physical data • Peer-to-peer communication • Computationally efficient machine-learning algorithms • Online cyber-physical data analysis • Alerting/visualization capabilities • Mitigation deployment capability with bump-in-the-wire (BITW) implementation Each of these functional objectives enable PIDMS to perform effective cyber-physical intrusion detection and mitigation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jones, Christian↗

Impact of Extreme Weather Events on Physical Protection System Effectiveness for a Hypothetical Small Modular Reactor Facility: Systems Analysis and Considerations

This report will summarize the group's work to provide recommendations to secure nuclear facilities before, during and after an extreme weather event. Extreme weather events can have drastic impacts to nuclear facilities as seen by the earthquake and subsequent tsunami at the Fukushima Daiichi Nuclear Power Plant in 2011. Recent hurricanes in the United States including Hurricane Harvey demonstrate the devastating effects these storms can have on infrastructure and the surrounding communities. The group is attempting to identify the gaps that potential small modular reactor (SMR) facilities will need to address in order to provide adequate site security before, during and after extreme weather events. This effort proceeded in three parts to provide insights and recommendations to secure Small Modular Reactor facilities for extreme weather events:(1) a literature review of academic articles as well as relevant documents including the existing regulatory framework and recommendations from the IAEA, NRC, and DOE, (2) subject matter expert interviews from a wide variety of security backgrounds, and (3) modeling and simulation on a hypothetical SMR facility. Special attention was paid to the interactions between stakeholders and nuclear facility design considerations, particularly the topics of safety and security. Engineering design issues from safety and security perspectives were discussed and included in simulation. Each step informed the proceeding, with the result including full tabletop scenarios of EWE impacts to security system effectiveness on the hypothetical model. This systems-level analysis provides results to inform recommendations to secure SMR facilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Small Reactor for Deep Space Exploration

This is the first demonstration of a space nuclear reactor system to produce electricity in the United States since 1965, and an experiment demonstrated the first use of a heat pipe to cool a small nuclear reactor and then harvest the heat to power a Stirling engine at the Nevada National Security Site's Device Assembly Facility confirms basic nuclear reactor physics and heat transfer for a simple, reliable space power system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗