Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Maximum Normalized Rate as a Flying Qualities Parameter

Discrete attitude commands have become a standard task for flying qualities evaluation and control system testing. Much pilot opinion data is now available for ground-based and in-flight simulations, but adequate performance measures and prediction methods have not been established. The Step Target Tracking Prediction method, introduced in 1978, correlated time-on-target and rms tracking data with NT-33 in-flight longitudinal simulations, but did not employ parameters easily measured in manned flight and simulation. Recent application of the Step Target Tracking Prediction method to lateral flying qualities analysis has led to a new measure of performance. This quantity, called Maximum Normalized Rate (MNR), reflects the greatest attitude rate a pilot can employ during a discrete maneuver without excessive overshoot and oscillation. MNR correlates NT-33 lateral pilot opinion ratings well, and is easily measured during flight test or simulation. Futhermore, the Step Target MNR method can be used to analyze large amplitude problems concerning rate limiting and nonlinear aerodynamics.

Onstott, E. D.↗

Maximum Normalized Rate as a Flying Qualities Parameter

Discrete attitude commands have become a standard task for flying qualities evaluation and control system testing. Much pilot opinion data is now available for ground-based and in-flight simulations, but adequate performance measures and prediction methods have not been established. The Step Target Tracking Prediction method, introduced in 1978, correlated time-on-target and rms tracking data with NT-33 in-flight longitudinal simulations, but did not employ parameters easily measured in manned flight and simulation. Recent application of the Step Target Tracking Prediction method to lateral flying qualities analysis has led to a new measure of performance. This quantity, called Maximum Normalized Rate (MNR), reflects the greatest attitude rate a pilot can employ during a discrete maneuver without excessive overshoot and oscillation. MNR correlates NT-33 lateral pilot opinion ratings well, and is easily measured during night test or simulation. Furthermore, the Step Target MNR method can be used to analyze large amplitude problems concerning rate limiting and nonlinear aerodynamics.

Onstott, E. D.↗

Ground truth data for test sites (SL-4)

Field measurements performed simultaneous with Skylab overpass in order to provide comparative calibration and performance evaluation measurements for the EREP sensors are presented. Wavelength region covered include: solar radiation (400 to 1300 nanometer), and thermal radiation (8 to 14 micrometer). Measurements consisted of general conditions and near surface meteorology, atmospheric temperature and humidity vs altitude, the thermal brightness temperature, total and diffuse solar radiation, direct solar radiation (subsequently analyzed for optical depth/transmittance), and target reflectivity/radiance. The particular instruments used are discussed along with analyses performed. Detailed instrument operation, calibrations, techniques, and errors are given.

Source record↗

High-speed communication detector characterization by bit error rate measurements

Performance data taken on several candidate high data rate laser communications photodetectors is presented. Measurements of bit error rate versus signal level were made in both a 1064 nm system at 400 Mbps and a 532 nm system at 500 Mbps. RCA silicon avalanche photodiodes are superior at 1064 nm, but the Rockwell hybrid 3-5 avalanche photodiode preamplifiers offer potentially superior performance. Varian dynamic crossed field photomultipliers are superior at 532 nm, however, the RCA silicon avalanche photodiode is a close contender.

Green, S. I.↗

Ground truth data for test sites (SL-3)

Field measurements performed simultaneously with Skylab overpasses in order to provide comparative calibration and performance evaluation measurements for the EREP sensors are presented. The solar radiation region from 400 to 1300 nanometers and the thermal radiation region from 8 to 14 micrometer region were investigated. The measurements of direct solar radiation were analyzed for atmospheric optical depth; the total and reflected solar radiation were analyzed for target reflectivity. These analyses were used in conjunction with a radiative transfer computer program in order to calculate the amount and spectral distribution of solar radiation at the apertures of the EREP sensors. The instrumentation and techniques employed, calibrations and analyses performed, and results obtained are discussed.

Source record↗

Evaluating generative networks using Gaussian mixtures of image features

We develop a measure for evaluating the performance of generative networks given two sets of images. A popular performance measure currently used to do this is the Fréchet Inception Distance (FID). However, FID assumes that images featurized using the penultimate layer of Inception follow a Gaussian distribution. This assumption allows FID to be easily computed, since FID uses the 2-Wasserstein distance of two Gaussian distributions fitted to the featurized images. However, we show that Inception features of the ImageNet dataset are not Gaussian; in particular, each marginal is not Gaussian. To remedy this problem, we model the featurized images using Gaussian mixture models (GMMs) and compute the 2-Wasserstein distance restricted to GMMs. We define a performance measure, which we call WaM, on two sets of images by using inception (or another classifier) to featurize the images, estimate two GMMs, and use the restricted 2-Wasserstein distance to compare the GMMs. We experimentally show the advantages of WaM over FID, including how FID is more sensitive than WaM to image perturbations. By modelling the non-Gaussian features obtained from inception as GMMs and using a GMM metric, we can more accurately evaluate generative network performance.

machine learning, genrative adversarial networks↗

10 ps resolution, 160 ns full scale range and less than 1.5% differential non-linearity time-to-digital converter module for high performance timing measurements

We present a compact high performance time-to-digital converter (TDC) module that provides 10 ps timing resolution, 160 ns dynamic range and a differential non-linearity better than 1.5% LSB{sub rms}. The TDC can be operated either as a general-purpose time-interval measurement device, when receiving external START and STOP pulses, or in photon-timing mode, when employing the on-chip SPAD (single photon avalanche diode) detector for detecting photons and time-tagging them. The instrument precision is 15 ps{sub rms} (i.e., 36 ps{sub FWHM}) and in photon timing mode it is still better than 70 ps{sub FWHM}. The USB link to the remote PC allows the easy setting of measurement parameters, the fast download of acquired data, and their visualization and storing via an user-friendly software interface. The module proves to be the best candidate for a wide variety of applications such as: fluorescence lifetime imaging, time-of-flight ranging measurements, time-resolved positron emission tomography, single-molecule spectroscopy, fluorescence correlation spectroscopy, diffuse optical tomography, optical time-domain reflectometry, quantum optics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-Bandgap Cu(In,Ga)S 2 Photocathodes Integrated on Transparent Conductive F:SnO 2 Substrates for Chalcopyrite-Based Water Splitting Tandem Devices

Recently, whole-chalcopyrite-based tandem devices for photoelectrochemical (PEC) water splitting have emerged as a promising route for obtaining ~20% solar-to-hydrogen efficiencies. Here we pursue this approach by demonstrating integration of the top cell wide-bandgap (E G ) chalcopyrite onto a transparent conductor, which is a critical step in the realization of tandem devices. We report specifically on our efforts to synthesize photoactive Cu(In,Ga)S 2 thin films on transparent conductive F:SnO 2 (FTO), while preserving the optoelectronic properties of the FTO substrate and preventing the formation of a resistive SnS x interfacial layer. We demonstrate that such attributes can be achieved via close-space sulfurization (CSS) of lower EG Cu(In,Ga)Se 2 precursors, co-evaporated on FTO at low-temperature. Depending on Cu(In,Ga)Se 2 precursors’ Ga and In content, the resulting Cu(In,Ga)S 2 solar absorbers have E G energies spanning 2.05 eV to 2.45 eV. The CSS process, which includes a low-temperature annealing in sulfur vapor followed by a high-temperature crystallization under inert atmosphere, allowed for up to 95% Se substitution with S in the chalcopyrite lattice, tuning both E G and band edge positions that impact PEC performance. Photoelectrochemical measurements performed under AM1.5G illumination in 0.5M H 2 SO 4 on the 2.05 eV CuInGaS 2 photocathode revealed a saturation photocurrent density (J SAT ) of -5.25 mA/cm 2 , a value corresponding to 38% of the absorber’s optical limit. We further concluded that such low J SAT originates from sub-par optical absorption of Cu(In,Ga)S 2 absorbers. Further enhancements of the CSS process are expected to improve material quality towards our end goal of achieving whole-chalcopyrite tandem PEC devices.

08 HYDROGEN↗

Longitudinal coherence and short-term wind speed prediction based on a nacelle-mounted Doppler lidar

The spatial structure of turbulence in atmospheric boundary layer flows is highly relevant to wind energy. In particular, wind turbine control strategies based on inflow preview measurements require knowledge of the longitudinal evolution of turbulent flow as it approaches the rotor. These upstream measurements are usually obtained with nacelle-mounted wind lidars. In contrast to traditional in situ anemometry, lidars collect measurements within a probe volume which varies in size depending on the technology of the commercial system being used. Here, we address two issues related to the use of wind lidar to measure the incoming flow to a wind turbine: (i) whether existing longitudinal coherence models can be used to predict flow at the rotor, based on measurements performed at a distance away from the rotor; and (ii) what effect probe-volume averaging has on the inflow predictions. These two questions are critical to the design and implementation of robust wind turbine control strategies. To address these questions, we perform field measurements and large-eddy simulations to determine which incoming flow structures can be readily predicted with existing coherence models, and which require additional corrections to account for lidar volumetric averaging effects. Results reveal that the wind turbine induction zone has a negligible impact on the longitudinal coherence and first-order turbulence quantities, such as the standard deviation of velocity fluctuations. However, the phase of the signal, from which advection time periods of the turbulent structures are derived, is affected by the rotor blockage effect.

17 WIND ENERGY↗

SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric quality assurance prior to MERT application.

60 APPLIED LIFE SCIENCES↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗

The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions

This brief report describes commissioning measurements performed using a newly constructed fast neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M3FT-13OR0402054, “Imager commissioning and 3D source configuration measurements” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast Neutron Imaging to Quantify Nuclear Materials - ORNL.” In addition to representing the first measurements made with the new device, these measurements also demonstrate for the first time the ability to localize one or more neutron sources in three dimensions by combining imaging data from multiple measurements in which the imager was positioned at different locations. The development and use of fast-neutron imaging technology are motivated by a desire to locate and quantify plutonium holdup in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. Considering the goal of quantitative measurements, fast neutrons (as opposed to the more numerous gamma rays) are preferred in many situations because of their ability to penetrate equipment and nuclear material that are essentially opaque to gamma radiation. However, there are many challenges associated with constructing a practical imager for fast neutrons. For example, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager that is sufficiently compact to be suitable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Moreover, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid, unlike the organic liquid scintillators that are typically used to achieve fast-neutron detection. Last of all, a single-sided measurement geometry, as is typically used in imaging applications, necessitates accurate measurement of the location of a deposit of plutonium holdup in three dimensions in order to correctly infer the source strength. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34. This report presents a description and preliminary analysis of mock holdup measurements intended to determine the three-dimensional location of one or more neutron sources placed in prototypical equipment from a set of imaging measurements that scanned the extent of the equipment.

Hausladen, Paul↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Annual Site Environmental Report Calendar Year 2007

This report summarizes the environmental status of Ames Laboratory for calendar year 2007. It includes descriptions of the Laboratory site, its mission, the status of its compliance with applicable environmental regulations, its planning and activities to maintain compliance, and a comprehensive review of its environmental protection, surveillance and monitoring activities. Ames Laboratory is located on the campus of Iowa State University (ISU) and occupies 11 buildings owned by the Department of Energy (DOE). See the Laboratory's Web page at www.external.ameslab.gov for locations and Laboratory overview. The Laboratory also leases space in ISU owned buildings. In 2007, the Laboratory accumulated and disposed of waste under U.S. Environmental Protection Agency (EPA) issued generator numbers. All waste is handled according to all applicable EPA, State, Local and DOE Orders. In 2006 the Laboratory reduced its generator status from a Large Quantity Generator (LQG) to a Small Quantity Generator (SQG). EPA Region VII was notified of this change. The Laboratory's RCRA hazardous waste management program was inspected by EPA Region VII in April 2006. There were no notices of violations. The inspector was impressed with the improvements of the Laboratory's waste management program over the past ten years. The Laboratory was in compliance with all applicable federal, state, local and DOE regulations and orders in 2007. There were no radiological air emissions or exposures to the general public due to Laboratory activities in 2007. See U.S. Department of Energy Air Emissions Annual Report in Appendix B. As indicated in prior SERs, pollution awareness, waste minimization and recycling programs have been in practice since 1990, with improvements implemented most recently in 2003. Included in these efforts were battery and CRT recycling, waste white paper and green computer paper-recycling. Ames Laboratory also recycles/reuses salvageable metal, used oil, styrofoam peanuts, batteries, fluorescent lamps and telephone books. Ames Laboratory reported to DOE-Ames Site Office (AMSO), through the Laboratory's Self Assessment Report, on its Affirmative Procurement Performance Measure. A performance level of 'A' was achieved in 2007 for Integrated Safety, Health, and Environmental Protection. As reported in Site Environmental Reports for prior years, the Laboratory's Environmental Management System has been integrated into the Laboratory's Integrated Safety Management System since 2005. The integration of EMS into the way the Laboratory does business allows the Laboratory to systematically review, address and respond to the Laboratory's environmental impacts.

54 ENVIRONMENTAL SCIENCES↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Degradation of learned skills. Effectiveness of practice methods on simulated space flight skill retention

Manual flight control and emergency procedure task skill degradation was evaluated after time intervals of from 1 to 6 months. The tasks were associated with a simulated launch through the orbit insertion flight phase of a space vehicle. The results showed that acceptable flight control performance was retained for 2 months, rapidly deteriorating thereafter by a factor of 1.7 to 3.1 depending on the performance measure used. Procedural task performance showed unacceptable degradation after only 1 month, and exceeded an order of magnitude after 4 months. The effectiveness of static rehearsal (checklists and briefings) and dynamic warmup (simulator practice) retraining methods were compared for the two tasks. Static rehearsal effectively countered procedural skill degradation, while some combination of dynamic warmup appeared necessary for flight control skill retention. It was apparent that these differences between methods were not solely a function of task type or retraining method, but were a function of the performance measures used for each task.

Sitterley, T. E.↗

A correlational approach to predicting operator status

This paper discusses a research approach for identifying and validating candidate physiological and behavioral parameters which can be used to predict the performance capabilities of aircrew and other system operators. In this methodology, concurrent and advance correlations are computed between predictor values and criterion performance measures. Continuous performance and sleep loss are used as stressors to promote performance variation. Preliminary data are presented which suggest dependence of prediction capability on the resource allocation policy of the operator.

Shingledecker, Clark A.↗