Indoor thermal performance evaluation of Daystar solar collector

The test procedures used and results obtained from a test program to obtain thermal performance data on a Daystar Model 21B, S/N 02210, Unit 2, liquid solar collector under simulated conditions are described. The test article is a flat plate solar collector using liquid as a heat transfer medium. The absorber plate is copper and coated with black paint. Between the tempered low iron glass and absorber plate is a polycarbonate trap used to suppress convective heat loss. The collector incorporates a convector heat dump panel to limit temperature excursions during stagnation. The following tests were conducted: (1) collector thermal efficiency; (2) collector time constant; (3) collector incident angle modifier; (4) collector heat loss coefficient; and (5) collector stagnation.

Shih, K., Sr.↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

A Performance Evaluation of NACK-Oriented Protocols as the Foundation of Reliable Delay- Tolerant Networking Convergence Layers

Delay-Tolerant Networking (DTN) is an active area of research in the space communications community. DTN uses a standard layered approach with the Bundle Protocol operating on top of transport layer protocols known as convergence layers that actually transmit the data between nodes. Several different common transport layer protocols have been implemented as convergence layers in DTN implementations including User Datagram Protocol (UDP), Transmission Control Protocol (TCP), and Licklider Transmission Protocol (LTP). The purpose of this paper is to evaluate several stand-alone implementations of negative-acknowledgment based transport layer protocols to determine how they perform in a variety of different link conditions. The transport protocols chosen for this evaluation include Consultative Committee for Space Data Systems (CCSDS) File Delivery Protocol (CFDP), Licklider Transmission Protocol (LTP), NACK-Oriented Reliable Multicast (NORM), and Saratoga. The test parameters that the protocols were subjected to are characteristic of common communications links ranging from terrestrial to cis-lunar and apply different levels of delay, line rate, and error.

Iannicca, Dennis↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

Thermal hydraulic analysis of the AFIP-7 irradiation test in the Advanced test Reactor – Model correlation and performance evaluation

We report as a system level code, RELAP5 is widely used in the nuclear field for the reactor hydraulic analysis. In the component/experimental level, it is frequently employed as well. This paper demonstrates that the RELAP5 flow simulation of the AFIP-7 irradiation experiment which has a complicated 3D geometry/flow path deviates by ~28% from the flow evaluation through a computational fluid dynamics (CFD) simulation, which has been validated against a flow test performed at Oregon State University. Thermal safety compliance analysis of an experiment planned to be irradiated in the Advanced Test Reactor is usually performed using the finite element analysis code, Abaqus. This research reveals the disadvantages of the Abaqus simulation in the flow instability and departure from nucleate boiling evaluations via a conjugate heat transfer analysis of the AFIP-7 irradiation experiment. As a result, a detailed CFD simulation is suggested for irradiation experiments with complicated flow paths, rather than a simplified RELAP5 simulation or hand calculations. The validated simulation approach will be integrated with the Boehmite correlations to investigate the oxide growth prediction on the fuel cladding in Part II of this research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

Source record↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

A comparative study of two-way and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US: performance evaluation and impacts of chemistry–meteorology feedbacks on air quality

The two-way coupled Weather Research and Forecasting and Community Multiscale Air Quality (WRF-CMAQ) model has been developed to more realistically represent the atmosphere by accounting for complex chemistry–meteorology feedbacks. In this study, we present a comparative analysis of two-way (with consideration of both aerosol direct and indirect effects) and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US. Long-term (5 years from 2008 to 2012) simulations using WRF-CMAQ with both offline and two-way coupling modes are carried out with anthropogenic emissions based on multiple years of the U.S. National Emission Inventory and chemical initial and boundary conditions derived from an advanced Earth system model (i.e., a modified version of the Community Earth System Model/Community Atmospheric Model). The comprehensive model evaluations show that both two-way WRF-CMAQ and WRF-only simulations perform well for major meteorological variables such as temperature at 2 m, relative humidity at 2 m, wind speed at 10 m, precipitation (except for against the National Climatic Data Center data), and shortwave and longwave radiation. Both two-way and offline CMAQ also show good performance for ozone (O3) and fine particulate matter (PM 2.5 ). Due to the consideration of aerosol direct and indirect effects, two-way WRF-CMAQ shows improved performance over offline coupled WRF and CMAQ in terms of spatiotemporal distributions and statistics, especially for radiation, cloud forcing, O 3 , sulfate, nitrate, ammonium, elemental carbon, tropospheric O 3 residual, and column nitrogen dioxide (NO 2 ). For example, the mean biases have been reduced by more than 10 W m –2 for shortwave radiation and cloud radiative forcing and by more than 2 ppb for max 8 h O 3 . However, relatively large biases still exist for cloud predictions, some PM 2.5 species, and PM 10 that warrant follow-up studies to better understand those issues. The impacts of chemistry–meteorological feedbacks are found to play important roles in affecting regional air quality in the US by reducing domain-average concentrations of carbon monoxide (CO), O 3 , nitrogen oxide (NO x ), volatile organic compounds (VOCs), and PM 2.5 by 3.1 % (up to 27.8 %), 4.2 % (up to 16.2 %), 6.6 % (up to 50.9 %), 5.8 % (up to 46.6 %), and 8.6 % (up to 49.1 %), respectively, mainly due to reduced radiation, temperature, and wind speed. The overall performance of the two-way coupled WRF-CMAQ model achieved in this work is generally good or satisfactory and the improved performance for two-way coupled WRF-CMAQ should be considered along with other factors in developing future model applications to inform policy making.

58 GEOSCIENCES↗

Performance Evaluation of the SPT-140

As part of an on-going cooperative program with industry, an engineering model SPT-140 Hall thruster, which may be suitable for orbit insertion and station-keeping of geosynchronous communication satellites, was evaluated with respect to thrust and radiated electromagnetic interference at the NASA Lewis Research Center. Performance measurements were made using a laboratory model propellant feed system and commercial power supplies. The engine was operated in a space simulation chamber capable of providing background pressures of 4 x 10(exp -6) Torr or less during thruster operation. Thrust was measured at input powers ranging from 1.5 to 5 kilowatts with two different output filter configurations. The broadband electromagnetic emission spectra generated by the engine was also measured for a range of frequencies from 0.01 to 18,000 Mhz. These results are compared to the noise threshold of the measurement system and MIL-STD-461C where appropriate.

Manzella, David↗

Failure analysis and performance evaluation of NASA inertial reference unit (DRIRU 2) after 50 months of orbital operation

The first production DRIRU 2 (NASA standard high performance inertial reference unit) system was launched as a subsystem of the Modular Attitude Control System for the Solar Maximum Mission (SMM) spacecraft in February 1980. This hardware was retrieved during the repair of the SMM during Shuttle Flight 41-C in April 1984 and returned to Teledyne Systems Company (manufacturer) for investigation and performance measurements as directed by Goddard Space Flight Center. A failure of one of the three gyro channels occurred approximately 6.5 months after launch. The built in redundancy functioned properly, the DRIRU 2 continued to provide the required attitude control function without performance degradation. Subsequent failure of other attitude control subsystems made the SMM a candidate for the first demonstration of the shuttle in-orbit repair capabilty. The in-orbit DRIRU 2 II failure scenario and the results of the analyses/tests conducted after retrieval are discussed. Comparison of this data with similar data prior to launch demonstates the excellent stability of performance parameters achieveable with DRIRU 2.

Green, K. N.↗

Performance Evaluation of Heterogeneous GPU Programming Frameworks for Hemodynamic Simulations

Preparing for the deployment of large scientific and engineering codes on upcoming exascale systems with GPU-dense nodes is made challenging by the unprecedented diversity of device architectures and heterogeneous programming models. In this work, we evaluate the process of porting a massively parallel, fluid dynamics code written in CUDA to SYCL, HIP, and Kokkos with a range of backends, using a combination of automated tools and manual tuning. We use a proxy application along with a custom performance model to inform the results and identify additional optimization strategies. At scale performance of the programming model implementations are evaluated on pre-production GPU node architectures for Frontier and Aurora, as well as on current NVIDIA device-based systems Summit and Polaris. Real-world workloads representing 3D blood flow calculations in complex vasculature are assessed. Our analysis highlights critical trade-offs between code performance, portability, and development time.

Martin, Aristotle↗