Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of a Stochastic Infiltration Model for PPA Implementation - 19293

Performance Assessment models often require inputs representing specific hydrologic processes and properties such as infiltration, water content, groundwater flow rate, streamflow, and sediment flux. This paper details the development of a process-level infiltration model and its use in a Probabilistic Performance Assessment (PPA) model for the West Valley Site in western New York. Additionally, this paper demonstrates a method for obtaining distributions of the long-term average hydrologic processes and properties for a PA model. For this PPA, an infiltration model was developed using HELP (Hydrologic Evaluation of Landfill Performance) to evaluate the rates of infiltration, percolation, and drainage through several site soil and proposed decommissioning cover systems, as well as the volumetric water contents of each of the unsaturated layers in a modeled soil column. A particular challenge of probabilistic modeling over long periods of time is scaling parameters appropriately so that outcomes are not grossly over- or underestimated. For these models, distributions of climatic parameters such as average precipitation rate, temperature, wind speed, humidity, and solar radiation were scaled to 1000-year averages and were used to force steady-state models that predict 1000-year average infiltration rates, drainage rates, and water contents. For the HELP model, distributions were developed for the physical and hydrologic properties of each material in a given soil column or cover system, and these properties were allowed to vary stochastically along with climatic inputs. The HELP model was run 5000 times for each of seven different soil and cover systems representing various existing and proposed conditions (i.e. native soil, backfill, existing covers, and a proposed close-in-place cover). The results of the HELP model provide ranges of 1000-year average infiltration rates, drainage rates, and water contents through and within the various layers of each of the different soil and cover conditions. The model outcomes also demonstrate the effectiveness of a proposed close-in-place cover, which essentially eliminates infiltration during its operational lifetime. Following model simulation, a sensitivity analysis was performed to establish the relative importance of each stochastic input with respect to each output. The outcomes of the model simulations and the sensitivity analysis were implemented into a system-level GoldSim model via a novel sensitivity-informed nearest neighbor approach. These infiltration rates, drainage rates, and water contents are used to parameterize mixing cells within the GoldSim Contaminant Transport module, which is the primary system-level model used in the PPA. The infiltration rates are also used as boundary conditions for a stochastic groundwater flow model that is also utilized in the PPA, but not discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements in Boron Plate Coating Technology for Higher Efficiency Neutron Detection and Coincidence Counting Error Reduction

This informal report presents the measurement data and information to document the performance of the advanced Precision Data Technology, Inc. (PDT) sealed cell boron-10 plate neutron detector that makes use of the advanced coating materials and procedures. In 2015, PDT changed the boron coating materials and application procedures to significantly increase the efficiency of their basic corrugated plate detector performance. A prototype sealed cell unit was supplied to LANL for testing and comparison with prior detector cells. Also, LANL had reference detector slabs from the original neutron collar (UNCL) and the new Antech UNCL with the removable 3He tubes. The comparison data is presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for thermodynamic evaluation of battery state of health

Described are systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and battery systems and for characterizing the state of health of electrodes and battery systems. Measurement of physical attributes of electrodes and batteries corresponding to thermodynamically stabilized electrode conditions permit determination of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and battery systems, such as energy, power density, current rate, cycle life and state of health. Also provided are systems and methods for charging a battery according to its state of health.

36 MATERIALS SCIENCE↗

Methods and systems for thermodynamic evaluation of battery state of health

Described are systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and battery systems and for characterizing the state of health of electrodes and battery systems. Measurement of physical attributes of electrodes and batteries corresponding to thermodynamically stabilized electrode conditions permit determination of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and battery systems, such as energy, power density, current rate, cycle life and state of health. Also provided are systems and methods for charging a battery according to its state of health.

25 ENERGY STORAGE↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

Assessing liver function: diagnostic efficacy of parenchymal enhancement and liver volume ratio of Gd-EOB-DTPA-enhanced MRI study during interstitial and hepatobiliary phase

Aim: To assess the efficacy of signal intensity in interstitial and hepatobiliary phase normalized for liver volume, on gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) study, for the evaluation of liver function through the comparison with Child–Pugh (CP), model for end-stage liver disease (MELD), and biochemical tests. Methods: All dynamic Gd-EOB-DTPA MRI studies performed in patients with suspected liver lesions were retrospectively reviewed. The rate of liver-to-muscle ratio on T1 sequence 70 s (interstitial phase) and 20 min (hepatobiliary phase) after injection of Gd-EOB-DTPA was calculated for each MRI study and then normalized for liver volume (irINTnorm and irHEPnorm). Pearson correlation coefficient was computed to assess the correlation among these values and CP and MELD scores, and biochemical tests. Results: A total of 303 MRI studies, performed on 221 patients, were included. Mean age was 63.8 years ± 12.9 with a majority of male patients (186; 61.4%). A total of 186 out of 303 (61.4%) were cirrhotic patients. The irHEPnorm was significantly lower in cirrhotic than non-cirrhotic patients (0.0004 ± 0.0002 to 0.0005 ± 0.0003, p = 0.010). This value had a moderate, significant correlation with Child–Pugh and MELD scores (R = − 0.292, p < 0.0001 and R = − 0.192, p = 0.010, respectively). In particular, irHEPnorm progressively decreased from Child–Pugh A to C (0.0004–0.0002, p < 0.0001) and from MELD ≤ 10 to 19–24 (0.0004–0.0003, p = 0.018). Among biochemical parameters, total bilirubin, GOT, and albumin had the strongest correlation with irHEPnorm (R = − 0.258, − 0.291, and 0.262, p < 0.0001, respectively). No correlations were found between irINTnorm and CP and MELD scores. Conclusion: irHEPnorm value derived from Gd-EOB-DTPA-enhanced MRI is a reliable, non-invasive, useful tool to quantify liver function and to assess the degree of cirrhosis, offering a strict relationship with clinical scores and biochemical parameters. This could help surgeons in clinical decision-making, allowing them to choose the more suitable surgical approach for cirrhotic patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CMPLE: Correlation Modeling to Decode Photosynthesis Using the Minorize–Maximize Algorithm

In plant genomic experiments, correlations among various biological traits (phenotypes) give new insights into how genetic diversity may have tuned biological processes to enhance fitness under diverse conditions. Consequently, knowing how the correlations are affected by genetic (G) and environmental (E) factors helps develop climate-resilient plants. However, the current literature lacks any method for assessing the effect of predictors on pairwise correlations among multiple phenotypes together with easily interpretable model parameters. To address this need, we propose to model pairwise correlations directly in terms of G and E and develop a computationally efficient inference procedure. Two major novelties in our methodology are (1) the use of a composite pairwise likelihood method to avoid the positive definiteness restriction on the correlation matrix and (2) the use of a novel Minorize–Maximize (MM) algorithm for the efficient estimation of a large number of parameters. The proposed method shows excellent numerical performance on synthetic datasets. Here, the analysis of the motivating data on cowpea reveals that the rates of solar energy storage by photosynthesis (the aggregate trait) are differentially affected by different genetic loci through two distinct processes: “photoinhibition” which results from photodamage caused by excess light, and “photoprotection” which protects plants from photodamage but also results in energy loss.

Correlation modeling↗

Near-zero photon bioimaging by fusing deep learning and ultralow-light microscopy

Enhancing the reliability and reproducibility of optical microscopy by reducing specimen irradiance continues to be an important biotechnology target. As irradiance levels are reduced, however, the particle nature of light is heightened, giving rise to Poisson noise, or photon sparsity that restricts only a few (0.5%) image pixels to comprise a photon. Photon sparsity can be addressed by collecting approximately 200 photons per pixel; this, however, requires long acquisitions and, as such, suboptimal imaging rates. Here, we introduce near-zero photon bioimaging, a method that operates at kHz rates and 10,000-fold lower irradiance than standard microscopy. To achieve this level of performance, we uniquely combined a judiciously designed epifluorescence microscope enabling ultralow background levels and AI that learns to reconstruct biological images from as low as 0.01 photons per pixel. We demonstrate that near-zero photon bioimaging captures the structure of multicellular and subcellular features with high fidelity, including features represented by nearly zero photons. Beyond optical microscopy, the near-zero photon bioimaging paradigm can be applied in remote sensing, covert applications, and biomedical imaging that utilize damaging or quantum light.

AI↗

Anomalous cross-field transport in a Hall thruster inferred from direct measurement of instability growth rates

The contribution of the electron drift instability to anomalous electron transport is experimentally assessed in a Hall effect discharge. The transport is represented by an anomalous collision frequency, which is related through quasilinear theory to the energy and growth rate of the instability. The wave energy is measured directly with ion saturation probes, while estimates of the growth rate are employed based on both linearized theory and direct measurement. The latter measurement is performed with a bispectral analysis method. The wave-driven collision frequency is compared to measurements of the actual collision frequency inferred from a method based on laser- induced fluorescence. It is found that estimates for transport using linearized theory for the growth differ by over an order of magnitude from the actual anomalous collision frequency in the plasma. The wave-driven anomalous collision frequency with measured growth, however, is shown to agree with the electron collision frequency in magnitude and capture aspects of the trends in spatial variation. This result demonstrates experimentally that wave-driven effects ultimately can explain the observed cross-field transport in these devices. As a result, the implications of this finding are discussed in the context of the key lengthscales that drive the transport as well as the implications identifying reduced fidelity models that could be used to predict anomalous collision frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-298: The Impact of Modeling the Treatment Couch On Patient Specific VMAT QA

Purpose: The aim of this work is to quantify the impact of modeling the treatment couch on the passing rate of ion chamber measurements during VMAT quality assurance. Methods: For the initial characterization, attenuation and surface dose measurements were performed following the guidelines of TG-176 for the Civco Universal couch top using an Elekta VersaHD accelerator at an energy of 6 MV. A simulation CT was performed to aid in the creation of contours for representing the shape and size of the couch top in the treatment planning system (TPS). A uniform value of density for the couch wall was determined by comparing the ratios of ion chamber measurements made in a 30×30×11 cm3 water phantom with the TPS dose values of a plan with the same geometry. At our institution, patient specific quality assurance is performed using a Sun Nuclear ArcCheck with a multi-plug for chamber measurements, a 0.125cc PTW TN31010 chamber, and a Sun Nuclear 1010 electrometer. Ten VMAT plans were transferred into the phantom geometry created in the TPS with two settings: with and without the couch. The chamber measurements were compared to both treatment plans. Results: A maximum attenuation of 3.6% was observed when the gantry angle was set to 120 and 240 degrees, passing obliquely through the couch. A uniform density of 0.6 g/cm3 for the couch wall was determined in the TPS by comparison with measured data. The VMAT ion chamber measurement/plan ratios systematically improved by 1.79% ±0.53% for all patients when the couch was included in the calculation. Conclusion: The attenuation and surface dose changes produced by the Civco couch can generate observable dose difference in VMAT plans. Including a couch model in the phantom plan used for patient specific VMAT QA can improve the ionization chamber agreement by up to ∼2%.

60 APPLIED LIFE SCIENCES↗

Upcycling Polyethylene Waste to Advanced Carbon Materials for Energy Storage Applications

Polyethylene is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into high-value carbon materials, such as graphene or graphite. We address this challenge by using an air-based, thermo-oxidation process, which heats polyethylene (PE) just below the decomposition point to initiate oxidation and cross-linking of PE alkyl chains. These molecular transformations allow PE to be further graphenized or graphitized at higher temperatures without decomposing. The PE-derived graphene has a specific surface area up to 1,800 m 2/g and Raman ID/IG ratio of 0.85, which enables it to be used as an electrode material for a symmetric supercapacitor with the 1 M H2SO4 electrolyte. The PE-derived graphene material has a comparable electrochemical capacitive performance, such as power density, specific capacitance, and long cycle stability, to the commercial state of art porous carbon electrode. The stabilized PE could also be converted into highly crystalline flake graphite via low-temperature catalytic graphitization. The PE-derived graphite is used for the lithium-ion battery anode, which showed comparable electrochemical battery performance, such as reversible rate performance and long-term cyclic stability, to the current use battery-grade graphite, thus providing a scalable method to upcycle PE plastic waste into high-value carbon material.

Gao, Yuan↗

Filter-Banks for Ultra-Wideband Communications, Sensing, and Localization

Recently, filterbank multi-carrier spread spectrum (FBMC-SS) has been proposed as a candidate waveform for ultrawideband (UWB) communications. It has been noted that FBMCSS is a perfect match to this application, leading to a trivial method of matching to the required spectral mask at different regions of the world. FBMC-SS also allows easy rejection of high-power interfering signals that may appear over different parts of the UWB spectral band. In this paper, we concentrate on the use of staggered multitone spread spectrum (SMT-SS) for UWB communications. SMT makes use of offset QAM modulation to transmit data symbols over narrowband, overlapping subcarrier bands. This form of FBMC-SS is well-suited to UWB communications because it has good spectral efficiency and a flat power spectral density (PSD), resulting in good utilization of the UWB spectral mask. Additionally, we explore new methods for multi-coding that result in higher bit rates than previous FBMCSS systems. Moreover, we study methods for equalizing the UWB multipath channel and cancelling narrowband interference. Excellent performance of the proposed methods are substantiated by presenting simulation results.

99 - GENERAL AND MISCELLANEOUS↗

SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on-table motion information.

60 APPLIED LIFE SCIENCES↗

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Mitigating oxygen loss to improve the cycling performance of high capacity cation-disordered cathode materials

Recent progress in the understanding of percolation theory points to cation-disordered lithium-excess transition metal oxides as high-capacity lithium-ion cathode materials. Nevertheless, the oxygen redox processes required for these materials to deliver high capacity can trigger oxygen loss, which leads to the formation of resistive surface layers on the cathode particles. Here, we demonstrate here that, somewhat surprisingly, fluorine can be incorporated into the bulk of disordered lithium nickel titanium molybdenum oxides using a standard solid-state method to increase the nickel content, and that this compositional modification is very effective in reducing oxygen loss, improving energy density, average voltage, and rate performance. We argue that the valence reduction on the anion site, offered by fluorine incorporation, opens up significant opportunities for the design of high-capacity cation-disordered cathode materials.

25 ENERGY STORAGE↗

Quantifying the Influences of Epoxide Binding in Epoxide/CO 2 Ring Opening Copolymerization Catalysis

Understanding and predicting the effect of epoxide structure on the rate of polymerization in epoxide/CO 2 ring opening copolymerization catalysis is a long-standing challenge. Here, a known highly active Co(III)K(I) catalyst is used to investigate the influences of six different epoxides' binding strengths on their rates of copolymerization. Since calculations and experiments indicate that studying the catalytically relevant Co(III)−epoxide adduct directly is experimentally challenging, epoxide−catalyst binding interactions are quantified using a Co(II)K(I) complex to model the key catalytic intermediate. Epoxide−catalyst coordination is investigated using UV−vis spectroscopy titrations which provide fast and effective determination of association or binding constants. The epoxide−catalyst equilibrium constants show a clear exponential correlation with copolymerization rates and a new catalyst performance linear free energy relationship is revealed. Epoxides exhibiting stronger catalyst binding constants show higher copolymerization rates. The structure−activity correlation is consistent with the polymerization kinetics, mechanism and DFT calculations. Both the methods to investigate epoxide−catalyst coordination and the linear free energy relationship are shown to apply to the series of six epoxides and a second Co(III)K(I) catalyst. These structure− performance relationships are likely applicable to other transition metal catalysts and should expedite future epoxide and catalyst selection to make useful poly(carbonate) materials.

catalysts↗