Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Determining the Impact of Steady-State PV Fault Current Injections on Distribution Protection

This report investigates the fault current contribution from a single large PV system and the impact it has on existing distribution overcurrent protection devices. Assumptions are made about the modeling of the PV system under fault to perform exhaustive steady - state fault analyses throughout distribution feeder models. Each PV interconnection location is tested to determine how the size of the PV system affects the fault current measured by each protection device. This data is then searched for logical conditions that indicate whether a protection device has operated in a manner that will cause more customer outages due to the addition of the PV system. This is referred to as a protection issue , and there are four unique types of issues that have been identified in the study. The PV system size at which any issues occur are recorded to determine the feeder's PV hosting capacity limitations due to interference with protection settings. The analysis is carried out on six feeder models. The report concludes with a discussion of the prevalence and cause of each protection issue caused by PV system fault current.

30 DIRECT ENERGY CONVERSION↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Will Solar Panels Help When the Power Goes Out? Planning for PV Resilience

PV systems, like all energy systems, must chart a difficult course in order to improve resilience. They need to simultaneously withstand extreme conditions that cause grid power disruptions, be configured in a way that allows electricity to be delivered to meet the PV user's needs, and overcome disruptions arising from solar resource intermittency. Certain considerations reveal themselves as key to a PV system's resilience benefits. Choice of hardware is critical, as is site selection for the PV array. Voluminous evidence in a hurricane context demonstrates that durable hardware, properly maintained and sited, leads to PV systems surviving extreme weather with their functionality intact. Structurally weak or poorly maintained PV equipment, on the other hand, has demonstrated failures during extreme weather events. PV system stakeholders should ensure that best practices are followed for hardware procurement and siting. It is also important to understand that PV systems are not one-size-fits-all. While incorporating islanding capabilities and energy storage into the system's electrical topology will typically enhance resilience, the user's needs will determine the optimally resilient conformation of any given system. These factors - appropriate hardware, siting, maintenance, and system design - are the primary drivers of PV resilience. PV systems possess high potential for resilient energy generation due to their distributed, abundant, and free fuel supply, but the technology itself does not inherently lead to resilient outcomes. Realizing PV's potential for resilience requires consideration of these determinative factors.

14 SOLAR ENERGY↗

Resilience Metrics Framework for Solar Photovoltaics

This presentation was given at the Photovoltaic Specialist Conference (PVSC) 54 in New Orleans, Louisiana. Photovoltaic (PV) systems are routinely exposed to extreme weather, including wind and hail storms. Historically, most systems have proven to be resilient to such events, but some storms have damaged PV systems, leading to physical and financial loss. Storm hardening measures and specific system attributes can reduce this risk. This work introduces a set of resilience metrics and a framework for quantifying, comparing, and predicting PV system resilience. The framework is divided into two parts: 1) predictive, attribute metrics based on site and component characteristics, and 2) impact metrics that assess post-storm performance. Metrics are weighted and aggregated, producing hazard-specific resilience scores. We derive damage functions from storm-impacted PV systems, establishing a baseline against which post-storm performance can be compared. This damage was widely variable across hail and wind intensities, and field hail damage was less than predicted by laboratory tests, suggesting that system features - in addition to storm conditions - influence damage likelihood. Finally, the metrics framework is demonstrated using three case studies of storm damaged PV systems. Although additional data are needed to create attribute specific damage functions and establish metric weights, this study presents a methodology for evaluating PV resilience and contributes new damage functions to the literature.

14 SOLAR ENERGY↗

Weather-Corrected Performance Ratio

Photovoltaic (PV) system performance depends on both the quality of the system and the weather. One simple way to communicate the system performance is to use the performance ratio (PR): the ratio of the electricity generated to the electricity that would have been generated if the plant consistently converted sunlight to electricity at the level expected from the DC nameplate rating. The annual system yield for flat-plate PV systems is estimated by the product of the annual insolation in the plane of the array, the nameplate rating of the system, and the PR, which provides an attractive way to estimate expected annual system yield. Unfortunately, the PR is, again, a function of both the PV system efficiency and the weather. If the PR is measured during the winter or during the summer, substantially different values may be obtained, making this metric insufficient to use as the basis for a performance guarantee when precise confidence intervals are required. This technical report defines a way to modify the PR calculation to neutralize biases that may be introduced by variations in the weather, while still reporting a PR that reflects the annual PR at that site given the project design and the project weather file. This resulting weather-corrected PR gives more consistent results throughout the year, enabling its use as a metric for performance guarantees while still retaining the familiarity this metric brings to the industry and the value of its use in predicting actual annual system yield. A testing protocol is also presented to illustrate the use of this new metric with the intent of providing a reference starting point for contractual content.

14 SOLAR ENERGY↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗

Incentive Pass-through for Residential Solar Systems in California

The deployment of solar photovoltaic (PV) systems has grown rapidly over the last decade, partly because of various government incentives. In the United States, among the largest and longest-running incentives have been those established in California. Building on past research, this report addresses the still-unanswered question: to what degree have the direct PV incentives in California been passed through from installers to consumers? This report helps address this question by carefully examining the residential PV market in California (excluding a certain class of third-party-owned PV systems) and applying both a structural-modeling approach and a reduced-form regression analysis to estimate the incentive pass-through rate. The results suggest an average pass-through rate of direct incentives of nearly 100%, though with regional differences among California counties. While these results could have multiple explanations, they suggest a relatively competitive market and well-functioning subsidy program. Further analysis is required to determine whether similar results broadly apply to other states, to other customer segments, to all third-party-owned PV systems, or to all forms of financial incentives for solar (considering not only direct state subsidies, but also utility electric bill savings and federal tax incentives).

14 SOLAR ENERGY↗

Imagine Homes New Construction Occupied Test House

This report summarizes the research findings of a long-term monitoring plan to evaluate the performance of an energy-efficient home constructed in 2010 in San Antonio, Texas. Monitoring of the energy use, energy generation, and temperature conditions for this project occurred between July 2010 and October 2011. The home achieves a source energy savings of 32% without the installed photovoltaic (PV) system and 44% savings with the PV system contribution relative to the Building America House Simulation Protocols. This report summarizes the research findings related to heating, ventilation, and air conditioning system performance, estimated and actual energy use of key subsystems, electricity generation by the PV system, and performance of the solar thermal domestic hot water system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaics as a terrestrial energy source. Volume 3: An overview

Photovoltaic (PV) systems were evaluated in terms of their potential for terrestrial application A comprehensive overview of important issues which bear on photovoltaic (PV) systems development is presented. Studies of PV system costs, the societal implications of PV system development, and strategies in PV research and development in relationship to current energy policies are summarized.

Smith, J. L.↗

North American Board of Certified Energy Practitioners Final Report

The U.S. DOE’s Office of EERE National Solar Energy Technology Program (SETP) calls for a “National Accreditation and Certification Program for Installation and Acceptance of Photovoltaic Systems.” A near-term goal listed in the U.S. Photovoltaic Industry’s Roadmap, 2000 - 2020 is to work to establish standards, codes, and certifications which are essential for consumer protection and acceptance as part of the goal of building toward a viable future PV industry. This program paves the way for a voluntary national certification program for PV system practitioners and installers, initiation of the first steps toward certification of hardware, and reinforcement of all five of the technical objectives in the Systems category of SETPs Multi-Year technical Plan. Through this project, NABCEP will direct the continued initiation of and sustained implementation and administration of the NABCEP Solar PV Installer Certification Program (hereafter the “Program”). The NABCEP Program is a national, voluntary program designed to provide certification for those PV installers who demonstrate the requisite skills, abilities and knowledge typically required to install and maintain PV systems. The core document upon which the Program was developed and upon which the national exam is based, is referred to as the (Program) Task Analysis. It is a thorough descriptive document containing specific psychomotor and cognitive tasks for the purposes of identifying the types of training/assessment methods that apply. Psychomotor skills require measuring, assembling, fastening and related activities. Cognitive skills require knowledge processing, decision-making and computations. NABCEP effectively evaluates an applicant’s psychomotor skills through review of a candidate’s PV installations and hands-on training received. NABCEP evaluates the candidate’s cognitive skills through administration of its national Program exam. By first qualifying for and then obtaining the required passing score, NABCEP certificants receive an accreditation that upholds NABCEP’s standards of quality, compliance to applicable codes and safety in PV installation. The objectives of DOE’s National Solar Energy Technology Program (SETP) are intrinsic to NABCEP. As detailed in the PV Roadmap, the lifespan of a PV system is a function of reliability and value. PV system reliability is directly dependent upon the quality of components and, design, installation and maintenance of a system. The latter three are all core components of the NABCEP Task Analysis - accordingly NABCEP certified installers will be instrumental in improving reliability of systems through safe, code and manufacturer-compliant installation and necessary post-installation maintenance of PV systems. This will have the effect of ensuring and increasing the performance of installed systems and, as consumers realize the benefits of well-installed and maintained systems, increased demand will follow and manufacturers will respond - supporting further growth in the PV industry. Furthermore, as more NABCEP certified installers perform these installations and maintenance competently, additional installations (whole system re-installations) and unnecessary repairs can be avoided. This will drive down system costs. This combined with creation/enhancement of the DE-FG36-04GO14348/005 NABCEP Central Data Base of Installers – providing consumers with installation/maintenance service options will further reduce system costs and help meet the overall goal of reducing life cycle costs. As consumers receive more value from PV systems which are providing longer, trouble free, renewable energy, they will join the ranks of professionals and enthusiasts calling for reduced technological barriers to installation (particularly for grid-tied systems). States and utilities will react to pressure and begin easing onerous net-metering and other technological restrictions. The benefits of NABCEP’s Program will be evident to consumers, manufacturers, distributors, state energy officials and solar academic institutions. Consumers benefit through increased system performance and reduced costs. Manufacturers of PV and balance of system components as well as distributors support and benefit from NABCEP because of assurances that systems are installed in accordance to code (i.e., NEC) and their specifications, resulting in longer life. Collaborators including state energy officials (i.e., New York State Energy Research and Development Authority) benefit by knowing that rebate funds are spent on systems whose benefits will far exceed system costs. Program Objectives The improvements and advantages offered by a national voluntary certification program can only expand the horizons for photovoltaic applications.

14 SOLAR ENERGY↗

Using spatio-temporal graph neural networks to estimate fleet-wide photovoltaic performance degradation patterns

Accurate estimation of photovoltaic (PV) system performance is crucial for determining its feasibility as a power generation technology and financial asset. PV-based energy solutions offer a viable alternative to traditional energy resources due to their superior Levelized Cost of Energy (LCOE). A significant challenge in assessing the LCOE of PV systems lies in understanding the Performance Loss Rate (PLR) for large fleets of PV systems. Estimating the PLR of PV systems becomes increasingly important in the rapidly growing PV industry. Precise PLR estimation benefits PV users by providing real-time monitoring of PV module performance, while explainable PLR estimation assists PV manufacturers in studying and enhancing the performance of their products. However, traditional PLR estimation methods based on statistical models have notable drawbacks. Firstly, they require user knowledge and decision-making. Secondly, they fail to leverage spatial coherence for fleet-level analysis. Additionally, these methods inherently assume the linearity of degradation, which is not representative of real world degradation. To overcome these challenges, we propose a novel graph deep learning-based decomposition method called the Spatio-Temporal Graph Neural Network for fleet-level PLR estimation (PV-stGNN-PLR). PV-stGNN-PLR decomposes the power timeseries data into aging and fluctuation components, utilizing the aging component to estimate PLR. PV-stGNN-PLR exploits spatial and temporal coherence to derive PLR estimation for all systems in a fleet and imposes flatness and smoothness regularization in loss function to ensure the successful disentanglement between aging and fluctuation. We have evaluated PV-stGNN-PLR on three simulated PV datasets consisting of 100 inverters from 5 sites. Experimental results show that PV-stGNN-PLR obtains a reduction of 33.9% and 35.1% on average in Mean Absolute Percent Error (MAPE) and Euclidean Distance (ED) in PLR degradation pattern estimation compared to the state-of-the-art PLR estimation methods.

14 SOLAR ENERGY↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗

Southwest Region Experiment Station - Final Technical Report

Southwest Technology Development Institute (SWTDI), an independent, university-based research institute, has been the operator of the Southwest Region Photovoltaic Experiment Station (SWRES) for almost 30 years. The overarching mission of SWTDI is to position PV systems and solar technologies to become cost-effective, major sources of energy for the United States. Embedded in SWTDI's general mission has been the more-focused mission of the SWRES: to provide value added technical support to the DOE Solar Energy Technologies Program (SETP) to effectively and efficiently meet the R&D needs and targets specified in the SETP Multi-Year Technical Plan. : The DOE/SETP goals of growing U.S. PV manufacturing into giga-watt capacities and seeing tera-watt-hours of solar energy production in the U.S. require an infrastructure that is under development. The staff of the SWRES has supported DOE/SETP through a coherent, integrated program to address infrastructural needs inhibiting wide-scale PV deployment in three major technical categories: specialized engineering services, workforce development, and deployment facilitation. The SWRES contract underwent three major revisions during its five year period-of- performance, but all tasks and deliverables fell within the following task areas: Task 1: PV Systems Assistance Center 1. Develop a Comprehensive multi-year plan 2. Provide technical workforce development materials and workshops for PV stakeholder groups including university, professional installers, inspectors, state energy offices, Federal agencies 3. Serve on the NABCEP exam committee 4. Provide on-demand technical PV system design reviews for U.S. PV stakeholders 5. Provide PV system field testing and instrumentation, technical outreach (including extensive support for the DOE Market Transformation program) Task 2: Design-for-Manufacture PV Systems 1. Develop and install 18 kW parking carport (cost share) and PV-thermal carport (Albuquerque) deriving and publishing lessons learned Task 3: PV Codes and Standards 1. Serve as the national lead for development and preparation of all proposals (related to PV) to the National Electrical Code 2. Participate in the Standards Technical Panels for modules (UL1703) and inverters (UL1741) Task 4: Assess Inverter Long Term Reliability 1. Install and monitor identical inverters at SWRES and SERES 2. Operate and monitor all inverters for 5 years, characterizing all failures and performance trends Task 5: Test and Evaluation Support for Solar America Initiative 1. Provide test and evaluation services to the National Laboratories for stage gate and progress measurements of SAI TPP winners

14 SOLAR ENERGY↗

Photovoltaics and Firefighters' Operations: Best Practices in Selected Countries

Components of photovoltaic (PV) systems undergo rigorous safety and reliability testing protocols during manufacturing and fulfill the electrical safety requirements established by various codes and standards. These systems do not pose health, safety, or environmental risks under normal operating conditions if properly installed and maintained by trained personnel as required by electrical codes. However, with the ever-growing deployment of PV systems globally and the myriad of applications - from traditional rooftop and ground-mounted installations to more advanced building-integrated and facade systems - it is becoming increasingly important to develop practices and share knowledge on the safe management and risk mitigation of PV systems under non-routine circumstances. This focus includes conditions in which firefighters encounter a PV system that may have been installed improperly or has become damaged. This report aims to facilitate the exchange of knowledge on the best practices and standards of firefighters' operations in relation to selected countries with considerable deployment of PV systems.

14 SOLAR ENERGY↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Generic solar photovoltaic system dynamic simulation model specification

This document is intended to serve as a specification for generic solar photovoltaic (PV) system positive-sequence dynamic models to be implemented by software developers and approved by the WECC MVWG for use in bulk system dynamic simulations in accordance with NERC MOD standards. Two specific dynamic models are included in the scope of this document. The first, a Central Station PV System model, is intended to capture the most important dynamic characteristics of large scale (> 10 MW) PV systems with a central Point of Interconnection (POI) at the transmission level. The second, a Distributed PV System model, is intended to represent an aggregation of smaller, distribution-connected systems that comprise a portion of a composite load that might be modeled at a transmission load bus.

14 SOLAR ENERGY↗

A Performance Model for Photovoltaic Modules with Integrated Microinverters

Photovoltaic (PV) systems using microinverters are becoming increasingly popular in the residential system market, as such systems offer several advantages over PV systems using central inverters. PV modules with integrated microinverters, termed AC modules, are emerging to fill this market space. Existing test procedures and performance models designed for separate DC and AC components are unusable for AC modules because these do not allow ready access to the intermediate DC bus. Sandia National Laboratories' Photovoltaics and Distributed Systems department has developed a set of procedures to test, characterize, and model PV modules with integrated microinverters. The resulting empirical model is able to predict the output AC power of with RMS error of 1-2%. This document describes these procedures and provides the results of model validation efforts.

14 SOLAR ENERGY↗