Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Software Verification of VARPOW

The VARPOW program is a post-processing utility program for DIF3D, specifically DIF3DVARIANT, and it was developed to provide interface files for the thermal analysis program DASSH. The basic methodology of VARPOW is to take the neutron and gamma flux (moments) calculated by DIF3D (or GAMSOR) and combine them with the heating (coefficient) cross sections to calculate the spatial power distributions using the DIF3DVARIANT spatial basis. VARPOW can use the output from GAMSOR (both steady state neutron and gamma flux calculations) or standard DIF3D/REBUS calculations (neutron flux only). The correct approach for defining the power distribution is to use GAMSOR as its purpose was to properly compute the gamma heating throughout the modeled domain. The power desnities calculated by VARPOW are broken into fuel, cladding and coolant terms for which isotope-wise categorization is needed. VARPOW has built in options the user can select for the isotope categorization or VARPOW can import a file that details the isotope categorization. VARPOW can export the solution in the polynomial basis of DIF3D-VARIANT or the monomial basis of DIF3D-VARIANT. Recently the clad neutron damage calculation capability was introduced into VARPOW, and it now allows a pathway to get distributions of clad DPA. The purpose of this work is to verify the power distribution, fast neutron flux and clad DPA results calculated by VARPOW from both the GAMSOR and DIF3D input options and verify that the input and output options are consistent with the manual. Hand calculation and independent numerical calculation are used for this verification work.

Zhong, Zhaopeng [Argonne National Laboratory (ANL)↗

Acoustic liner optimum impedance for spinning modes with mode cut-off ratio as the design criterion

The theoretical optimum acoustic impedance for higher order spinning modes was studied in cylindrical ducts with a boundary layer at the outer edge of a uniform flow. All of the propagating modes were considered from highly propagating to nearly cut-off. It was observed that the mode cut-off ratio uniquely determined the optimum wall impedance and maximum possible attenuation for a given boundary layer thickness, Mach number and frequency. The implications of this phenomenon are quite important in noise suppressor design. Instead of the acoustic power distribution among all of the propagating modes, only the power distribution as a function of cut-off ratio needs to be known. Also, the far field radiation pattern is a function of modal cut-off ratio, and much needed information for liner design can be obtained from these more easily obtained data.

Rice, E. J.↗

Flexible Operation of Microgrids Through Operator-Configurable Microgrid Controllers

Microgrids are becoming critical assets in power distribution systems. This is partly due to the resiliency and reliability challenges faced by power distribution systems in the last decade and partly due to the increased integration of distributed energy resource assets, such as solar photovoltaic. This increased need for microgrids has created a multitude of needs for microgrid controllers. Most microgrid controllers in the past decade have been uniquely programmed or custom programmed to meet the needs of a specific microgrid. Currently, IEEE standards aim to integrate the needs and capabilities of microgrid controllers under a unified umbrella. But the standards do not recommend necessary or appropriate software development practices for microgrid controllers. In addition, the programmable nature and maintenance of controllers are also key characteristics that fall outside the coverage of the standards. In this paper, we present the best software practices that utility engineers and microgrid operators should consider in the microgrid software platform. This paper can be used as an information document for developing documentation of controller requirements and assessing microgrid controller requirements.

Banshee microgrid↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automation in the Space Station module power management and distribution Breadboard

The Space Station Module Power Management and Distribution (SSM/PMAD) Breadboard, located at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, models the power distribution within a Space Station Freedom Habitation or Laboratory module. Originally designed for 20 kHz ac power, the system is now being converted to high voltage dc power with power levels on a par with those expected for a space station module. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level process consists of fast, simple (from a computing standpoint) switchgear, capable of quickly safing the system. The next level consists of local load center processors called Lowest Level Processors (LLP's). These LLP's execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. The level above the LLP's contains a Communication and Algorithmic Controller (CAC) which coordinates communications with the highest level. Finally, at this highest level, three cooperating Artificial Intelligence (AI) systems manage load prioritization, load scheduling, load shedding, and fault recovery and management. The system provides an excellent venue for developing and examining advanced automation techniques. The current system and the plans for its future are examined.

Walls, Bryan↗

Multiobjective optimization of nuclear microreactor reactivity control system operation with swarm and evolutionary algorithms

To improve the marketability of novel microreactor designs, there is a need for automated and optimal control of these reactors. This paper presents a methodology for performing multiobjective optimization of control drum operation for a microreactor under normal and off-nominal conditions. Here, two different case studies are used where the control drum configuration is optimized for the reactor to be critical with some desired power distribution that would satisfy peaking limits. A surrogate model for power distribution is developed based on a feedforward neural network. The process for determining weights for scalarization of the multiobjective optimization problem is also detailed. Six optimization algorithms: evolutionary strategies, differential evolution, grey wolf optimization, Harris hawks optimization, moth flame optimization and particle swarm optimization, are all applied to these cases and the results analyzed. Although all these algorithms will demonstrate optima-seeking behavior, for real-time control it is necessary to identify the best algorithm to efficiently provide reasonable optima without operator interference. The moth flame optimization algorithm was found to perform particularly well on both cases. Overall, it was found that the algorithms capable of supplying the best optima were also the most consistent. Finally, the found optima were verified with the original model used to train surrogates.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of MOOSE-based Griffin reactor physics, code for heterogeneous lead-cooled fast reactor analysis

The MOOSE-based reactor physics code Griffin was assessed on a heterogeneous pin-resolved model of a prototype lead-cooled fast reactor assembly. This model was developed in preparation for future use in MOOSE-based multiphysics calculations for computing hot channel factors. Heterogeneous multigroup cross sections were prepared using the fast reactor multi-group cross section processing code MC{sup 2}-3 using a two-step method. Griffin simulations were performed using the DFEM-SN solver on 576 cores on Argonne's LCRC cluster. Diffusion-based acceleration methods were applied (NDA and CMFD). Reference solutions were generated with continuous energy MCNP and the hybrid MOC/finite element solver PROTEUS-MOC for code-to-code comparison. Space-angle convergence studies were conducted to observe convergence in k-eigenvalue and axial pin power distributions. The fully resolved Griffin calculation was within 68 pcm of the MCNP eigenvalue and exhibited max 1.2% relative error in the axial pin power distribution. Griffin produced nearly identical results to PROTEUS-MOC when using the same 9-group multigroup cross-section set. Griffin demonstrated favorable scaling in wall-clock time and memory usage when using diffusion-based acceleration methods. Griffin is capable of simulating the pin-resolved heterogeneous LFR assembly with good accuracy and performance, and is suitable for future use in coupled high-fidelity hot channel factor simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hierarchical Flexibility Offering Strategy for Integrated Hybrid Resources in Real-time Energy Markets

This paper proposes a hierarchical model for determining the energy flexibility offering strategy of integrated hybrid resources (IHRs) in power distribution systems to participate in real-time energy markets. The proposed model utilizes the scalability, fast response time, and uncertainty observation of deep reinforcement learning (DRL) to overcome the scalability issue of operating numerous flexible resources and deliverability of energy flexibility to the real-time markets in the presence of the network constraints. To that end, the power distribution system is divided into multiple IHRs, where different types of flexible loads, energy storage systems, and solar plants with controllable inverters are operated through local IHR controllers, trained by deep deterministic policy gradient (DDPG) algorithm. Active power request and reactive power capacity of IHRs are then transmitted to a central flexibility controller, where a quadratic optimization model ensures the deliverability of the energy flexibility to the real-time energy market by satisfying the distribution network constraints. The proposed model is implemented on the 123-bus test power distribution system, demonstrating the capability of DRL-based hierarchical model for scalable operation of IHRs in order to offer deliverable energy flexibility to the real-time energy market.

Majidi, Majid↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗

Integrity of Ceramic Parts Predicted When Loads and Temperatures Fluctuate Over Time

Brittle materials are being used, and being considered for use, for a wide variety of high performance applications that operate in harsh environments, including static and rotating turbine parts for unmanned aerial vehicles, auxiliary power units, and distributed power generation. Other applications include thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and microelectromechanical systems (MEMS). In order for these high-technology ceramics to be used successfully for structural applications that push the envelope of materials capabilities, design engineers must consider that brittle materials are designed and analyzed differently than metallic materials. Unlike ductile metals, brittle materials display a stochastic strength response because of the combination of low fracture toughness and the random nature of the size, orientation, and distribution of inherent microscopic flaws. This plus the fact that the strength of a component under load may degrade over time because of slow crack growth means that a probabilistic-based life-prediction methodology must be used when the tradeoffs of failure probability, performance, and useful life are being optimized. The CARES/Life code (which was developed at the NASA Glenn Research Center) predicts the probability of ceramic components failing from spontaneous catastrophic rupture when these components are subjected to multiaxial loading and slow crack growth conditions. Enhancements to CARES/Life now allow for the component survival probability to be calculated when loading and temperature vary over time.

Nemeth, Noel N.↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

Review of the Technical Basis for Properties and Fuel Performance Data Used in HEU to LEU Conversion Analysis for U-10Mo Monolithic Alloy Fuel

This report provides the technical basis for properties and fuel performance data used in conversion analysis for U.S. High Performance Research Reactors (USHPRR) that will convert from highly enriched uranium (HEU) to low-enriched uranium (LEU) using a new U-10Mo monolithic alloy fuel that is being qualified. The conditions that the fuel experiences changes between an HEU and LEU fuel element design due to many causes, including the density of the fuel, the presence of U-238 resonant absorber, changes to the plate and coolant channel dimensions, and changes in fuel management due to reactivity or optimization. These types of changes have been documented in operational and safety analyses conducted for conversions over decades for over 70 reactors. These conversions have all, or almost all, required recalculation of safety-related values as well as establishing operational characteristics of the core, including power distribution, reactor core power level, and cycle length between required fuel management. An overall objective of conversion is to change the reactor core design as little as possible while maintaining the reactors’ scientific, isotope production, medical, and engineering missions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automating a spacecraft electrical power system using expert systems

Since Skylab, Marshall Space Flight Center (MSFC) has recognized the need for large electrical power systems (EPS's) in upcoming Spacecraft. The operation of the spacecraft depends on the EPS. Therefore, it must be efficient, safe, and reliable. In 1978, as a consequence of having to supply a large number of EPS personnel to monitor and control Skylab, the Electrical power Branch of MSFC began the autonomously managed power system (AMPS) project. This project resulted in the assembly of a 25-kW high-voltage dc test facility and provided the means of getting man out of the loop as much as possible. AMPS includes several embedded controllers which allow a significant level of autonomous operation. More recently, the Electrical Division at MSFC has developed the space station module power management and distribution (SSM/PMAD) breadboard to investigate managing and distributing power in the Space Station Freedom habitation and laboratory modules. Again, the requirement for a high level of autonomy for the efficient operation over the lifetime of the station and for the benefits of enhanced safety has been demonstrated. This paper describes the two breadboards and the hierarchical approach to automation which was developed through these projects.

Lollar, L. F.↗

Advanced propulsion engine assessment based on a cermet reactor

A preferred Pratt & Whitney conceptual Nuclear Thermal Rocket Engine (NTRE) has been designed based on the fundamental NASA priorities of safety, reliability, cost, and performance. The basic philosophy underlying the design of the XNR2000 is the utilization of the most reliable form of ultrahigh temperature nuclear fuel and development of a core configuration which is optimized for uniform power distribution, operational flexibility, power maneuverability, weight, and robustness. The P&W NTRE system employs a fast spectrum, cermet fueled reactor configured in an expander cycle to ensure maximum operational safety. The cermet fuel form provides retention of fuel and fission products as well as high strength. A high level of confidence is provided by benchmark analysis and independent evaluations.

Parsley, Randy C.↗

Description of the SSF PMAD dc testbed control system data acquisition function

A functional description of the various levels of the SSF power management and distribution dc test-bed control system architecture is presented, and the data acquisition function and the status of its implementation are described. The data requirements for the test-bed control system are dictated by the functionality being implemented at each level of the architecture. The test-bed control system hierarchy data acquisition function is distributed among its various levels. Fast-acting control functions that require time critical data are implemented at the lowest level. These functions require periodic data sampling to assure safe system operation and performance. Slower response control functions are implemented at the higher levels and require data to be reported at least every second. The present data acquisition function meets the requirements for a hierarchical and distributed power management and control system.

Baez, Anastacio N.↗

Latching-Relay Driver And Continuity Checker

Driving circuit and associated continuity-checking circuit enable use of latching relay switch instead of non-latching relay switch in 120-Vdc power-distribution system. Average power consumed reduced by about 15 W. Latching-relay driver and continuity checker provides automatic turnoff relay when power fails, or alarm indicating discontinuity in turn-off circuit, respectively.

Kachelski, Thomas A.↗