Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE IDENTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

TMD PDFs in Drell-Yan lepton pair production at LHC

We consider the transverse momentum dependent (TMD) quark densities of the proton which are very important ingredients for unpolarized Drell-Yan (DY) lepton pair production. We calculate the TMD sea quark density as a convolution of the Catani-Ciafaloni-Fiorani-Marchesini (CCFM)-evolved gluon distribution and the TMD gluon-to-quark splitting function. Based on the O(α{sup 2}) production amplitude q{sup *}+(q-bar){sup *} →Z/γ{sup *}→l{sup +}+l{sup −}, calculated by taking into account the effective q{sup *}(q-bar){sup *}Z/γ{sup *} - vertex, we analyze the distributions on the dilepton invariant mass, transverse momentum and rapidity and specific angular correlations between the produced leptons as measured by the CMS, ATLAS and LHCb collaborations. We briefly duscuss also the process of assiciated lepton pair and jet production in pp collisions at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the AFP project in the ATLAS experiment

Status of the AFP project in the ATLAS experiment is summarized. The AFP system is composed of a tracker to detect intact, diffractively scattered protons, and of a time-of-flight detector serving to suppress background from pile-up interactions. The whole system, located around 210 m from the main ATLAS detector, is placed in Roman Pots which move detectors from and to the incident proton beams. A typical distance of the closest approach of the tracker to these beams is 2–3 mm. The main physics motivation lies in measuring diffractive processes in runs with not a very high amount of pile-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-peripheral heavy-ion collisions with CMS

Ultra-peripheral collisions (UPCs) of heavy ions involve long range electromagnetic interactions at impact parameters larger than twice the nuclear radius. At TeV energies, the strong electromagnetic field due to the coherent action of the Z = 82 proton charges generates a large flux of photons, which can be used for high-energy photoproduction studies. Heavy vector mesons produced in electromagnetic interactions provide direct information on the parton distribution functions in the nucleus at very low values of Bjorken-x. These events are characterized by a very low hadron multiplicity. The wide pseudo-rapidity coverage of the CMS detectors is used to separate such events from very peripheral nuclear interactions. The CMS experiment has excellent capabilities for the measurement of the heavy vector mesons in the dimuon decay channel using the tracker and the muon chambers. This analysis demonstrates CMS’s capabilities for measuring J/ψ and the two-photon process in ultra-peripheral collisions, using the 2011 PbPb and 2013 pPb data. The prospects for future measurements using the data to be collected in the 2015 PbPb run will be described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak production of strange particles off the nucleon

The strange particle production off the nucleon induced by neutrinos and antineutrinos is investigated at low and intermediate energies. We develop a microscopic model based on the SU(3) chiral Lagrangian. The studied mechanisms are the main source of single kaon production for (anti)neutrino energies up to 1.5 GeV. Using this model we have also studied the associated production of kaons and hyperons. The cross sections are large enough to be measured by experiments such as MINERνA, T2K and NOνA.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How much does the MSW effect contribute to the reactor antineutrino anomaly?

It has been pointed out that there is a 5.7 ± 2.3 discrepancy between the predicted and the observed reactor antineutrino flux in very short baseline experiments. Several causes for this anomaly have been discussed, including a possible non-standard forth sterile neutrino. In order to quantify how much non-standard this anomaly really is, the standard MSW effect is reviewed. Knowing that reactor antineutrinos are produced in a dense medium (the nuclear fuel) and is usually detected in a less dense one (water, or scintillator), non-adiabatic effects are expected to happen, creating a difference between the creation and detection mixing angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of pion production in eA with the CLAS detector

Preliminary results on semi-inclusive charged pion production in eA collisions at E{sub beam}=5 GeV/c{sup 2} are presented. The data were collected using the CLAS detector, which is a multipurpose, large acceptance, magnetic spectrometer located in Hall B at the Thomas Jefferson National Accelerator Facility. Selected distributions in W, Q{sup 2}, p{sub π}, and θ{sub π} are shown for data produced using deuterium, carbon, iron and lead targets. Preliminary comparisons with data simulated using the GENIE generator are made. The motivation for this work is to provide distributions useful for tuning the hadronic final state interaction models in order to reduce uncertainties in the results extracted from current and next-generation neutrino oscillation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of neutrino induced NC-1π{sup 0} using the T2K-ND280 tracker

Single π{sup 0} production is the one of the most important backgrounds in the υ{sub e} appearance measurement in T2K. Large uncertainties in this production make it difficult to predict. Measurement at the near detector (ND280) is required both to constrain the background prediction at the far detector (Super-K) and also at the near detector to improve knowledge of beam υ{sub e} contamination. We present an analysis based on Monte Carlo simulation of neutral current (NC) single π{sup 0} in the tracker region. NC-1π{sup 0} events are selected using a specific two-gamma signature in the tracker region. One decay gamma is reconstructed by selecting an e+/e− pair starting in the Fine-Grained target Detector (FGD) and extending into the TPC, where the leptons can be identified and their momentum measured accurately. The second gamma is then selected in-time in the Calorimeter modules surrounding the tracker. Selections cuts, efficiency and purity of the selection are presented and projection of the expected number of single π{sup 0} candidates for 3 × 10{sup 20} protons on target (PoT) exposure is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance interaction in LBNE fine-grained-tracker near detector

This talk is devoted to resonance interaction (RES) in the proposed fine-grained tracker detector (FGT) for LBNE experiment. We use fast MC to study the sensitivity of FGT to RES, and use this measurement as a handle to constrain nuclear effects. Similar analysis is performed on NOMAD data for validation and better understanding. Preliminary RES measurement result using NOMAD data will be reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast simulation of electromagnetic and hadronic showers in SpaCal calorimeter at the H1 experiment

The fast simulation of showers induced by electrons (positrons) in the H1 lead/scintillating-fiber calorimeter, SpaCal, based on shower library technique has been presented previously. In this paper we show the results on linearity and uniformity of the reconstructed electron/positron cluster energy in electromagnetic section of Spacal for the simulations based on shower library and GFLASH shower parametrisation. The shapes of the clusters originating from photon and hadron candidates in SpaCal are analysed and experimental distributions compared with the two simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multifractal moments in heavy ion Pb-Pb collisions at 158 A GeV

In present work, we use the method of scaled factorial moments to search for intermittent behavior in Pb-Pb interactions at 158 A GeV. The analysis is done on photon distributions obtained using preshower photon multiplicity detector. Scaled factorial moments are used to study short range fluctuations in pseudorapidity distributions of photons. Scaled factorial moments are calculated using horizontal corrected and vertical analysis. The results are compared with simulation analysis using VENUS event generator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identifying the theory of dark matter with direct detection

Identifying the true theory of dark matter depends crucially on accurately characterizing interactions of dark matter (DM) with other species. In the context of DM direct detection, we present a study of the prospects for correctly identifying the low-energy effective DM-nucleus scattering operators connected to UV-complete models of DM-quark interactions. We take a census of plausible UV-complete interaction models with different low-energy leading-order DM-nuclear responses. For each model (corresponding to different spin–, momentum–, and velocity-dependent responses), we create a large number of realizations of recoil-energy spectra, and use Bayesian methods to investigate the probability that experiments will be able to select the correct scattering model within a broad set of competing scattering hypotheses. We conclude that agnostic analysis of a strong signal (such as Generation-2 would see if cross sections are just below the current limits) seen on xenon and germanium experiments is likely to correctly identify momentum dependence of the dominant response, ruling out models with either “heavy” or “light” mediators, and enabling downselection of allowed models. However, a unique determination of the correct UV completion will critically depend on the availability of measurements from a wider variety of nuclear targets, including iodine or fluorine. We investigate how model-selection prospects depend on the energy window available for the analysis. In addition, we discuss accuracy of the DM particle mass determination under a wide variety of scattering models, and investigate impact of the specific types of particle-physics uncertainties on prospects for model selection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessing compatibility of direct detection data: halo-independent global likelihood analyses

We present two different halo-independent methods to assess the compatibility of several direct dark matter detection data sets for a given dark matter model using a global likelihood consisting of at least one extended likelihood and an arbitrary number of Gaussian or Poisson likelihoods. In the first method we find the global best fit halo function (we prove that it is a unique piecewise constant function with a number of down steps smaller than or equal to a maximum number that we compute) and construct a two-sided pointwise confidence band at any desired confidence level, which can then be compared with those derived from the extended likelihood alone to assess the joint compatibility of the data. In the second method we define a “constrained parameter goodness-of-fit” test statistic, whose p-value we then use to define a “plausibility region” (e.g. where p≥10%). For any halo function not entirely contained within the plausibility region, the level of compatibility of the data is very low (e.g. p<10%). We illustrate these methods by applying them to CDMS-II-Si and SuperCDMS data, assuming dark matter particles with elastic spin-independent isospin-conserving interactions or exothermic spin-independent isospin-violating interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress status for the Mu2e calorimeter system

The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of ADRIANO R&D in T1015 Collaboration

The physics program for future High Energy and High Intensity experiments requires an energy resolution of the calorimetric component of detectors at limits of traditional techniques and an excellent particle identification. The novel ADRIANO technology (A Dualreadout Integrally Active Non-segmented Option), currently under development at Fermilab, is showing excellent performance on those respects. Results from detailed Monte Carlo studies on the performance with respect to energy resolution, linear response and transverse containment and a preliminary optimization of the layout are presented. A baseline configuration is chosen with an estimated energy resolution of σ(E)/E ≈ 30%/√E , to support an extensive R&D program recently started by T1015 Collaboration at Fermilab. Furthermore, preliminary results from several test beams at the Fermilab Test Beam Facility (FTBF) of a ~ 1λI prototype are presented. Future prospects with ultra-heavy glass are, also, summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing with Silicon Sensors for Use in Calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 10 34 cm -2 s -1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation Light Detection System in LArIAT

The LArIAT experiment is currently taking data at Fermilab using a Liquid Argon TPC, with the aim of studying particle interactions and characterizing detector response for neutrino detectors using argon. In parallel, it serves as a test-bench to develop and evaluate the performance of the simulation, reconstruction, and analysis software used in LAr neutrino experiments. LArIAT also takes advantage of the scintillating capabilities of liquid argon and will evaluate the feasibility of using the light signal to determine calorimetric information and particle identification. To test this possibility, a scintillation light detection system consisting of high Quantum Efficiency (QE) PMT and Silicon Photomultiplier (SiPM) devices is installed in the cryostat, viewing the interior of the TPC. Light collection efficiency is maximized by means of lining the walls with reflector foils covered by a wavelength shifter layer. Collecting the light reflected at the boundaries of the active volume greatly improves also the uniformity of the light yield. Presented here are initial results of the LArIAT light detection system calibration together with the preliminary results of the dedicated simulation and its application in future LAr TPC experiments

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗