Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Illustration of Key Considerations Determining Hazardous Indoor Inhalation Exposures

Buildings can protect their occupants from outdoor hazards. In some cases, this protection can reduce hazardous exposures by an order of magnitude or more. The degree to which indoor exposures are reduced, relative to being outdoors, depends upon the specific building, hazardous material, and exposure pathway. This report illustrates how several key considerations interrelate to determine the building protection against indoor inhalation of outdoor airborne hazards. These considerations are the (1) outdoor plume duration, (2) loss of airborne material indoors, (3) rate at which outdoor and indoor air is exchanged, (4) importance of peak concentration to hazard toxicity, and (5) the time, after the outdoor plume has passed, that individuals exit (or ventilate) the building. This report focuses on “passive” building protection for inhalation exposures – the protection that buildings provide their occupants under normal operating conditions against outdoor inhalation hazards. With active measures, such as turning off building ventilation systems, building protection can be higher than the illustrative values shown here.

54 ENVIRONMENTAL SCIENCES↗

Building America Case Study: Evaluation of Passive Vents in New-Construction Multifamily Buildings, New York, New York

Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as a potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of phenotype stability and ecological risk of a genetically engineered alga in open pond production

Genetically engineered (GE) algae offer the promise of producing food, fuel, and other valuable products with reduced requirements for land and fresh water. While the gains in productivity measured in GE terrestrial crops are predicted to be mirrored in GE algae, the stability of phenotypes and ecological risks posed by GE algae in large-scale outdoor cultivation remain unknown. In this paper, we describe the first US Environmental Protection Agency (EPA)-sanctioned experiment aimed at understanding how GE algae perform in outdoor cultivation. Acutodesmus dimorphus was genetically engineered by the addition of two genes, one for enhanced fatty acid biosynthesis, and one for recombinant green fluorescence protein (GFP) expression; both the genes and their associated phenotypes were maintained during fifty days of outdoor cultivation. We also observed that while the GE algae dispersed from the cultivation ponds, colonization of the trap ponds by the GE strain declined rapidly with increasing distance from the source cultivation ponds. In contrast, many species of indigenous algae were found in every trap pond within a few days of starting the experiment. When inoculated in water from five local lakes, the GE algae's effect on biodiversity, species composition, and biomass of native algae was indiscernible from those of the wild-type (wt) progenitor algae, and neither the GE nor wt algae were able to outcompete native strains. We conclude that GE algae can be successfully cultivated outdoors while maintaining GE traits, and that for the specific GE algal strain tested here they did not outcompete or adversely impact native algae populations when grown in water taken from local lakes. Finally, this study provides an initial evaluation of GE algae in outdoor cultivation and a framework to evaluate GE algae risks associated with outdoor GE algae production.

09 BIOMASS FUELS↗

DISCOVR strain pipeline screening – Part II: Winter and summer season areal productivities and biomass compositional shifts in climate-simulation photobioreactor cultures

Assessing the seasonal biomass productivity and compositional shift dynamics under simulated outdoor culture conditions of the top 22 algae strains selected during Tier I flask screening is an important step in the further prioritization of strains with regard to outdoor pond cultivation. These top 22 strains were subjected to Tier II testing in the PNNL Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, simulating light and temperature conditions of 20 cm deep outdoor ponds during the Arizona winter and summer season. All strains were grown in two consecutive nutrient-replete batch culture experiments at their particular optimal medium salinity to quantify their respective seasonal linear-phase areal biomass productivities. To determine biomass compositional shifts in response to nutrient-depletion, the LEAPS cultures were allowed to enter a 9-day nutrient depletion phase at the end of the second batch run. The following strains were evaluated in winter-season climate-simulated cultures and are listed in the order from highest (7.9 g m -2 day -1 ) to lowest (2.3 g m -2 day -1 ) areal N-replete biomass productivity: Monoraphidium minutum 26B-AM, Tetraselmis striata LANL1001, Chlorella vulgaris LRB AZ-1201, Micractinium reisseri NREL14-F2, Monoraphidium sp. MONOR1, Chlorella vulgaris NREL4-C12, Scenedesmus obliquus UTEX393, Scenedesmus acutus LRB-AP-0401, Nannochloropsis oceanica CCAP849/10, and Stichococcus minutus CCALA727. The following strains were evaluated in summer-season climate-simulated cultures and are listed in the order from highest (31.8 g m -2 day -1 ) to lowest (14.2 g m -2 day -1 ) areal N-replete biomass productivity: Picochlorum renovo NREL39-A8, Scenedesmus obliquus UTEX393, Porphyridium cruentum CCMP675, Picochlorum celeri TG2-WT-CSM/EMRE, Chlorella sorokiniana DOE1116, Stichococcus minor CCMP819, Picochlorum oklahomensis CCMP2329, Chlorella sorokiniana DOE1412 (UTEXB3016), Scenedesmus rubescens NREL46B-D3, Picochlorum soloecismus DOE101, Tetraselmis striata LANL1001, Scenedesmus obliquus DOE 0152.z, and Agmenellum quadruplicatum UTEX2268. All LEAPS cultures experienced a significant reduction in areal biomass productivity in response to nutrient-depletion, from 7-16% in the winter season simulation and up to 1-60% in the summer season simulation. Finally, for 10 of the strains tested, the carbohydrate content more than doubled upon nutrient depletion, and for 9 strains, the lipid content increased by over 50% of the initial content.

09 BIOMASS FUELS↗

Effect of Ventilation Strategies on Residential Ozone Levels

Elevated outdoor ozone levels are associated with adverse health effects. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone of outdoor origin would lower population exposures and might also lead to a reduction in ozone-associated adverse health effects. In most buildings, indoor ozone levels are diminished with respect to outdoor levels to an extent that depends on surface reactions and on the degree to which ozone penetrates the building envelope. Ozone enters buildings from outdoors together with the airflows that are driven by natural and mechanical means, including deliberate ventilation used to reduce concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only the positive effects on removing pollutants of indoor origin but also the possibility that enhanced ventilation might increase indoor levels of pollutants originating outdoors. This study considers how changes in residential ventilation that are designed to comply with ASHRAE Standard 62.2 might influence indoor levels of ozone. Simulation results show that the building envelope can contribute significantly to filtration of ozone. Consequently, the use of exhaust ventilation systems is predicted to produce lower indoor ozone concentrations than would occur with balanced ventilation systems operating at the same air-­exchange rate. We also investigated a strategy for reducing exposure to ozone that would deliberately reduce ventilation rates during times of high outdoor ozone concentration while still meeting daily average ventilation requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

A measurement of forward-flight effects on the noise from a JT15D-1 turbofan engine in the NASA-Ames 40- by 80-Foot Wind Tunnel

A Pratt and Whitney JT15D-1 turbofan engine was tested in two facilities at Ames Research Center: the outdoor Static Test Facility and the 40- by 80-Foot Wind Tunnel. The primary purposes of the test were to determine the effects of forward velocity on the turbofan spectra in the forward quadrant for the cruise inlet and to compare these wind-tunnel spectra with outdoor spectra to determine the possibility of simulating forward-velocity effects from purely outdoor measurements. The wind-tunnel data show a reduction in the blade-passage frequency tones of the order of 10 dB with increasing forward velocity at subsonic fan-tip speeds. No forward-velocity variation was observed at supersonic tip speeds. Comparison of in-duct spectra for the cruise inlet at forward velocity, with spectra from outdoor tests with a distortion-control inlet shows excellent agreement for the in-duct data when allowance is made for different in-duct volumes. This is also reflected in good agreement for the far-field spectra at small forward angles. The comparisons of wind-tunnel and outdoor data also indicate that at least for the JT15D-1, it may be possible to approximate the shape of the far-field spectra at large directivity angles from an outdoor measurement with the cruise inlet, providing an effective inflow control device is used.

Ahtye, W. F.↗

A streamlined approach to characterize microalgae strains for biomass productivity under dynamic climate simulation conditions

Screening microalgae strains under static light and temperature flask conditions cannot directly quantify the biomass productivities of algae growing in the dynamically fluctuating light and temperature conditions of outdoor ponds. In this effort, we describe a testing pipeline that screens for productivity under climate simulated conditions. A validated, miniaturized Laboratory Environmental Algae Pond Simulator (mini-LEAPS) photobioreactor was used to determine optimal medium salinities and biomass productivities of cold-tolerant microalgae collected from Arctic, subarctic, Antarctic, and subalpine habitats. Strains characterized in this effort include: Chlorella antarctica UTEX1959, Chlorella sp. UTEXSNO69, Chloromonas rosae UTEXSNO11, Phaeodactylum tricornutum UTEX646, and Stichococcus minutus CCALA727. Observed productivities of the characterized strains ranged from 1.74 ± 0.25 to 8.18 ± 0.81 g m –2 day –1 (as ash-free dry weight). For each strain, a temperature tolerance profile was generated to identify the most appropriate season (s) for cultivation. The two most promising strains, Chlorella sp. UTEX SNO69 and P. tricornutum UTEX646, were tested alongside the DISCOVR winter benchmark strain Monoraphidium minutum 26B-AM in outdoor open ponds at the PNNL Algae Testbed (PAT) in Arizona. Further, under cold-season outdoor pond conditions, Chlorella sp. UTEXSNO69 achieved average areal biomass productivities of 8.21 ± 0.50 g m –2 day –1 , not significantly different from that of the benchmark strain (8.52 ± 0.43 g m –2 day –1 , p > 0.05). Under spring outdoor pond conditions, P. tricornutum UTEX646 achieved average areal biomass productivities 10.34 ± 0.27 g m –2 day –1 , not significantly different from that of the benchmark (10.07 ± 0.50 g m –2 day –1 ) under the tested conditions (p > 0.05). The streamlined pipeline was thus demonstrated to successfully characterize productive microalgae strains for outdoor deployment by weeding out algae strains that were not productive under the tested dynamic light and temperature conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System

This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of potential aerosol transmission and infectivity of SARS-CoV-2 through central ventilation systems

Here we evaluate the concentrations and probabilities of infection for both building interior and exterior exposure sources using a well-mixed model in a connected multizone building. As a central hub of many community and economic activities, buildings provide social connectivity, but the COVID-19 pandemic has reduced social connectivity due to concerns of viral spread within buildings. Although single zone models of infectious spread are well studied, the impact of aerosolized spread of SARS-CoV-2 via air handling systems in multizone buildings remains unexplored. Here we evaluate the influence of filtration, air exchange rates, and the fraction of outdoor air on the probability of infection using the well-known well-mixed modeling approach for a multizone. We find filtration lowers the concentration and probability of infection in both source and connected rooms provided at least some air is recirculated, but that probability is not zero. Filtration has no influence without recirculation or unless the outdoor air contains virus. We find that increasing the air exchange rate removes virus from the source room faster but also increases the rate of exposure to connected rooms. Therefore, slower air exchange rates reduce infectivity in connected rooms at shorter durations, but higher air exchange rates reduce infectivity at longer durations. We further find that when outdoor air is virus free, increasing the fraction of outdoor air is helpful, but, when outdoor air is infective, pathogen exposure inside can persist for hours after a short-term release.

60 APPLIED LIFE SCIENCES↗

An approach to assess the Particulate Matter exposure for the population living around a cement plant: modelling indoor air and particle deposition in the respiratory tract

In this paper we studied the exposure to three size fractions of outdoor particulate matter (PM{sub 10}, PM{sub 2.5}, and PM{sub 1}) collected in an area influenced by a cement plant. For that purpose, three groups of population were evaluated (children, adults and retired) in two seasons (summer and winter). Outdoor measured PM concentrations, as well as physiological parameters and activity patterns of the three groups of population were used as input data in two different models. The first one was an indoor air quality model, used to elucidate indoor PM concentrations in different microenvironments. The second one was a dosimetry model, used to evaluate the internal exposure and the distribution of the different PM fractions in the respiratory tract. Results from the indoor air quality model showed that special attention must be paid to the finest particles, since they penetrate indoors in a greater degree. Highest pulmonary doses for the three PM sizes were reported for retired people, being this a result of the high amount of time in outdoor environments exercising lightly. For children, the exposure was mainly influenced by the time they also spend outdoors, but in this case due to heavy intensity activities. It was noticed that deposition of fine particles was more significant in the pulmonary regions of children and retired people in comparison with adults, which has implications in the expected adverse health effects for those vulnerable groups of population. - Highlights: • PM deposition in the respiratory tract was evaluated for three population groups. • Activity patterns and different microenvironments were used in our calculation. • Outdoor activities are the main contributors to PM deposited mass. • Children experienced the highest deposition dose in the pulmonary region. • Retired registered the highest deposited mass in the respiratory tract as a whole.

54 ENVIRONMENTAL SCIENCES↗

Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates

Past field research and simulation studies have shown that high performance homes experience elevated indoor humidity levels for substantial portions of the year in humid climates. This is largely the result of lower sensible cooling loads, which reduces the moisture removed by the cooling system. These elevated humidity levels lead to concerns about occupant comfort, health and building durability. Use of mechanical ventilation at rates specified in ASHRAE Standard 62.2-2013 are often cited as an additional contributor to humidity problems in these homes. Past research has explored solutions, including supplemental dehumidification, cooling system operational enhancements and ventilation system design (e.g., ERV, supply, exhaust, etc.). This project’s goal is to develop and demonstrate (through simulations) smart ventilation strategies that can contribute to humidity control in high performance homes. These strategies must maintain IAQ via equivalence with ASHRAE Standard 62.2-2013. To be acceptable they must not result in excessive energy use. Smart controls will be compared with dehumidifier energy and moisture performance. This work explores the development and performance of smart algorithms for control of mechanical ventilation systems, with the objective of reducing high humidity in modern high performance residences. Simulations of DOE Zero-Energy Ready homes were performed using the REGCAP simulation tool. Control strategies were developed and tested using the Residential Integrated Ventilation (RIVEC) controller, which tracks pollutant exposure in real-time and controls ventilation to provide an equivalent exposure on an annual basis to homes meeting ASHRAE 62.2-2013. RIVEC is used to increase or decrease the real-time ventilation rate to reduce moisture transport into the home or increase moisture removal. This approach was implemented for no-, one- and two-sensor strategies, paired with a variety of control approaches in six humid climates (Miami, Orlando, Houston, Charleston, Memphis and Baltimore). The control options were compared to a baseline system that supplies outdoor air to a central forced air cooling (and heating) system (CFIS) that is often used in hot humid climates. Simulations were performed with CFIS ventilation systems operating on a 33% duty-cycle, consistent with 62.2-2013. The CFIS outside airflow rates were set to 0%, 50% and 100% of 62.2-2013 requirements to explore effects of ventilation rate on indoor high humidity. These simulations were performed with and without a dehumidifier in the model. Ten control algorithms were developed and tested. Analysis of outdoor humidity patterns facilitated smart control development. It was found that outdoor humidity varies most strongly seasonally—by month of the year—and that all locations follow the similar pattern of much higher humidity during summer. Daily and hourly variations in outdoor humidity were found to be progressively smaller than the monthly seasonal variation. Patterns in hourly humidity are driven by diurnal daily patterns, so they were predictable but small, and were unlikely to provide much control benefit. Variation in outdoor humidity between days was larger, but unpredictable, except by much more complex climate models. We determined that no-sensor strategies might be able to take advantage of seasonal patterns in humidity, but that real-time smart controls were required to capture variation between days. Sensor-based approaches are also required to respond dynamically to indoor conditions and variations not considered in our analysis. All smart controls face trade-offs between sensor accuracy, cost, complexity and robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of mechanical stress or abscisic acid on growth, water status and leaf abscisic acid content of eggplant seedlings

Container-grown eggplant (Solanum melongena L. var esculentum Nees. 'Burpee's Black Beauty') seedlings were conditioned with brief, periodic mechanical stress or abscisic acid (ABA) in a greenhouse prior to outdoor exposure. Mechanical stress consisted of seismic (shaking) or thigmic (stem flexing) treatment. Exogenous ABA (10(-3) or 10(-4)M) was applied as a soil drench 3 days prior to outdoor transfer. During conditioning, only thigmic stress reduced stem elongation and only 10(-3) M ABA reduced relative growth rate (RGR). Both conditioning treatments increased leaf specific chlorophyll content, but mechanical stress did not affect leaf ABA content. Outdoor exposure of unconditioned eggplant seedlings decreased RGR and leaf-specific chlorophyll content, but tended to increase leaf ABA content relative to that of plants maintained in the greenhouse. Conditioning did not affect RGR of plants subsequently transferred outdoors, but did reduce stem growth. Seismic stress applied in the greenhouse reduced dry weight gain by plants subsequently transferred outdoors. Mechanical stress treatments increased leaf water potential by 18-25% relative to that of untreated plants.

NASA Discipline Plant Biology↗

Use of the SPoRT Stoplight Product to Support NWS Decision Support Services

The National Weather Service Forecast Offices (NWSFOs) use many weather tools and observational datasets to provide support for critical decision-making by core partners such as public safety officials, emergency managers, and first responders. These core partners who need weather decision support services (DSS) for outdoor events require up-to-the-minute weather information to ensure the safety and protection of attendees and workers. Storms and lightning, potentially deadly, pose a significant threat during outdoor events and are among the weather phenomena frequently cited as a DSS requirement. According to the National Lightning Safety Council, from 2014 up to August 2024, lightning resulted in 222 fatalities in the U.S. For outdoor events with hundreds to thousands of attendees, having the right tools to detect and monitor lightning activity is of utmost importance to protect lives. Common guidelines for lightning safety include moving inside a substantial structure at the first sight of threatening skies or the first sound of thunder, and waiting 30 minutes after the last lightning flash or thunder before returning outside. Using this guidance as a framework, scientists at the NASA Short-term Prediction Research and Transition (SPoRT) center have developed the Geostationary Lightning Mapper (GLM) Stoplight tool. This experimental tool uses the GLM Flash Extent Density imagery to display the location and recency of lightning flashes. To simplify interpretation, these lightning pixels are color-coded in 10-minute bins, ranging from red (lightning detected 0 to 10 minutes ago) to yellow (10 to 20 minutes ago) to green (20 to 30 minutes ago). The Stoplight tool also allows users to place markers at the location of outdoor events with range rings around the location to help in assessing the location and relative age of lightning flashes near and upstream of the event. The goal is to help NWS forecasters provide core partners with the necessary information to make the best decisions possible. While the Stoplight tool is experimental, forecasters at NWSFO Raleigh, NC, have periodically used the Stoplight guidance to evaluate its utility within NWS DSS. This presentation will discuss how the Stoplight tool was successfully used for DSS for four outdoor events in central NC in 2023 and 2024. Future improvements to this tool, including the addition of AI applications and the merging of ground-based lightning data with GLM data, will be reviewed.

Gail Hartfield↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Compendium of photovoltaic degradation rates

Abstract Published data on photovoltaic (PV) degradation measurements were aggregated and re‐examined. The subject has seen an increased interest in recent years resulting in more than 11 000 degradation rates in almost 200 studies from 40 different countries. As studies have grown in number and size, we found an impact from sampling bias attributable to size and accuracy. Because of the correlational nature of this study we examined the data in several ways to minimize this bias. We found median degradation for x‐Si technologies in the 0.5–0.6%/year range with the mean in the 0.8–0.9%/year range. Hetero‐interface technology (HIT) and microcrystalline silicon (µc‐Si) technologies, although not as plentiful, exhibit degradation around 1%/year and resemble thin‐film products more closely than x‐Si. Several studies showing low degradation for copper indium gallium selenide (CIGS) have emerged. Higher degradation for cadmium telluride (CdTe) has been reported, but these findings could reflect a convolution of less accurate studies and longer stabilization periods for some products. Significant deviations for beginning‐of‐life measurements with respect to nameplate rating have been documented over the last 35 years. Therefore, degradation rates that use nameplate rating as reference may be significantly impacted. Studies that used nameplate rating as reference but used solar simulators showed less variation than similar studies using outdoor measurements, even when accounting for different climates. This could be associated with confounding effects of measurement uncertainty and soiling that take place outdoors. Hotter climates and mounting configurations that lead to sustained higher temperatures may lead to higher degradation in some, but not all, products. Wear‐out non‐linearities for the worst performing modules have been documented in a few select studies that took multiple measurements of an ensemble of modules during the lifetime of the system. However, the majority of these modules exhibit a fairly linear decline. Modeling these non‐linearities, whether they occur at the beginning‐of‐life or end‐of‐life in the PV life cycle, has an important impact on the levelized cost of energy. Copyright © 2016 John Wiley & Sons, Ltd.

Jordan, Dirk C.↗

Measure Guideline: Condensing Boilers - Optimizing Efficiency and Response Time During Setback Operation

Conventional wisdom surrounding space heating has told us a couple of things consistently for several years now: size the mechanical systems to the heating loads and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. Determining the appropriateness of setback for a particular project is the first step. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step by step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗