Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron generators.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Comprehensive Review of DPF-based Flash Neutron Radiography Viability

MJOLNIR (MegaJOule Neutron Imaging Radiography) is a Dense Plasma Focus (DPF) being developed by LLNL as a prototype to assess the viability of a DPF as a flash neutron radiography source. To date, MJOLNIR has discharged up to 1.3 MJ of stored energy into a deuterium plasma load and achieved yields up to 1.2 × 10 12 neutrons per discharge. The MJOLNIR pulse length already meets the preliminary requirements for flash neutron radiography and we demonstrate in this report plausible paths forward to meet the yield requirement in a deuterium plasma. MJOLNIR’s neutron spot size has been characterized to be a factor of two greater than radiography requirements and presents the greatest challenge. A path forward to sufficiently shrinking spot size is outlined in this report, using a combination of gas dopants and a smaller anode implosion radius. A DPF is a plasma device with coaxial electrodes whose discharge ends with a stagnated hot and dense plasma column on-axis, at the tip of the central anode. Inside the MJOLNIR DPF plasma column, both thermal and beam target processes generate neutrons. To understand the underlying physics of neutron generation inside the DPF, we model the experiment using a combination of kinetic, fluid, and reduced-order models we have been developing for over ten years at LLNL. Our numerical tools are also pivotal to charting the path forward because they allow us to numerically test out which modifications would improve the DPF’s characteristic output.

42 ENGINEERING↗

Fissile Material Detection Using a Prompt Fission Neutron Chamber System

The calculations supporting the design of a chamber system to detect and verify fissile material in items such as mail packages or luggage are described. Stimulated neutrons from fission are separated from those produced by the system 14 MeV neutron generators by time delay. The proposed system design has a chamber volume of 60 × 60 × 90 cm. It is anticipated that at least 1g of fissile material could be detected in as little as 5s of interrogation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydration-Dependent Dynamical Transition in Protein: Protein Interactions at 240 K

Interprotein motions in low and fully hydrated carboxymyoglobin crystals are investigated using molecular dynamics simulation. Below {approx} 240 K, the calculated dynamic structure factor exhibits a peak arising from interprotein vibration. Above {approx} 240 K, the intermolecular fluctuations of the fully hydrated crystal increase drastically, whereas the low-hydration model exhibits no transition. Autocorrelation function analysis shows the transition to be dominated by the activation of diffusive intermolecular motion. The potential of mean force for the interaction remains quasiharmonic. The results indicate useful experimental avenues on protein:protein interactions to be explored using next-generation neutron sources.

59 BASIC BIOLOGICAL SCIENCES↗

Strategy for the absolute neutron emission measurement on ITER

Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10{sup 10} n/s (neutron/second) for DT and 10{sup 8} n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Angular Distributions of Gamma Rays from the Inelastic Scattering of 14.1-MeV Neutrons by Carbon and Oxygen Nuclei

The results obtained by measuring the angular and energy distributions of gamma rays originating from the inelastic scattering of 14.1-MeV neutrons by carbon and oxygen nuclei are presented. The measurements in question were performed by the tagged-neutron method in a beam of an ING-27 standard portable neutron generator. The angular distributions of gamma rays emitted by the 2{sup +} state of {sup 12}С at 4.43 MeVand the 3{sup −} state of {sup 16}O at 6.13 MeV were obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Effect of high current electron beam in a 30 MeV radio frequency linac for neutron-time-of-flight applications

A high power pulsed radio frequency electron linac is designed by BARC, India to accelerate 30 MeV, 10 A, 10 ns beam for neutron-time-of-flight applications. It will be used as a neutron generator and will produce ∼10{sup 12}–10{sup 13} n/s. It is essential to reduce the beam instability caused by space charge effect and the beam cavity interaction. In this paper, the wakefield losses in the accelerating section due to bunch of RMS (Root mean square) length 2 mm (at the gun exit) is analysed. Loss and kick factors are numerically calculated using CST wakefield solver. Both the longitudinal and transverse wake potentials are incorporated in beam dynamics code ELEGANT to find the transverse emittance growth of the beam propagating through the linac. Beam loading effect is examined by means of numerical computation carried out in ASTRA code. Beam break up start current has been estimated at the end of the linac which arises due to deflecting modes excited by the high current beam. At the end, transverse beam dynamics of such high current beam has been analysed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of ZnO:Ga as an Ultrafast Scintillator

We report on several methods for synthesizing the ultra-fast scintillator ZnO(Ga), and measurements of the resulting products. This material has characteristics that make it an excellent alpha detector for tagging the time and direction of individual neutrons produced by t-d and d-d neutron generators (associated particle imaging). The intensity and decay time are strongly dependent on the method used for dopant incorporation. We compare samples made by diffusion of Ga metal to samples made by solid state reaction between ZnO and Ga2O3 followed by reduction in hydrogen. The latter is much more successful and has a pure, strong near-band-edge fluorescence and an ultra-fast decay time of the x-ray-excited luminescence. The luminescence increases dramatically as the temperature is reduced to 10K. We also present results of an alternate low-temperature synthesis that produces luminescent particles with a more uniform size distribution. We examine possible mechanisms for the bright near-band-edge scintillation and favor the explanation that it is due to the recombination of Ga3+ donor electrons with ionization holes trapped on H+ ion acceptors.

36 MATERIALS SCIENCE↗

250 kV 6 mA compact Cockcroft-Walton high-voltage power supply

A compact power supply system for a compact neutron generator has been developed. A 4-stage symmetrical Cockcroft-Walton circuit is adopted to produce 250 kV direct current high-voltage. A 2-stage 280 kV isolation transformer system is used to drive the ion source power supply. For a compact structure, safety, and reliability during the operation, the Cockcroft-Walton circuit and the isolation transformer system are enclosed in an epoxy vessel containing the transformer oil whose size is about ∅350 mm × 766 mm. Test results indicate that the maximum output voltage of the power supply is 282 kV, and the stability of the output voltage is better than 0.63% when the high voltage power supply is operated at 250 kV, 6.9 mA with the input voltage varying ±10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Material and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory's PINS Chemical Assay System has traditionally used a {sup 252}Cf isotopic neutron source, but recently a deuterium-tritium (DT) electronic neutron generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition

The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗

New-Generation Thermal Neutron Detectors and Electronics for High-Count-Rate Applications

Neutron measurements are important in many nonproliferation and treaty verification applications. Helium-3 proportional counters and analog electronics are the backbone of neutron detection systems. Helium-3 tubes with a 1-in. diameter have been used with classical electronics for over three decades because of the almost ideal behavior of the 3 He tube as a neutron detector. However, some demanding applications of 3 He tubes (high gamma dose rate, high count rate) and the use of non-ideal detectors (such as 10 B-lined proportional counters) mean that the limitations of these conventional systems are being reached. For example, neutron multiplicity deadtime corrections can be large, and some applications have had trouble with multiple pulsing. Also, instrumentation designs for spent fuel applications often rely on large amounts of lead shielding to reduce the gamma dose at the detector location, making them heavy and expensive. This major challenge for a short dead time and operation in high gamma fields is difficult to address by simply changing the gas admixture and tweaking the shaper time constants. Those small gains are adequate for measurements of some lower-burn-up, low-enrichment-uranium spent fuel assemblies, but not for mixed oxide (MOX) fuel or advanced fast reactor fuel, where the neutron source term is greater.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

33 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_neutron_eta35

Single particle gun for detector studies: A particle gun with single neutrons. One neutron per event. 5000 events per file, 50 files per sample. Production at (x,y,z,t)=(0,0,0,0). N and antiN are alternated. Momentum is 1, 2, 4, 8, 16, 32, .. 2^n (n=0,15). The energy is included to the file name. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-3.5, 3.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toroidal–Poloidal Magnetic Field Generation in Neutron Stars by Spacetime Frame-dragging

Neutron star magnetic fields, particularly in magnetars, have strong poloidal and toroidal components, reaching magnitudes up to 10{sup 15} T and extending into the magnetosphere, where they cause twisted magnetic fields and surface currents. Here, we show that to a large extent neutron star toroidal and poloidal magnetic fields are due to frame-dragging of spacetime in the stellar exterior. In the explicit case of linearized Kerr metric we show that general relativistic Maxwell equations admit a mixed poloidal and toroidal magnetic field configuration in which the toroidal field strength is comparable with the poloidal magnetic field. Calculations are performed to show that the frame-dragging-induced magnetic field has the observed order of magnitude at the stellar surface, and exhibits the flare-like phenomenon observed in magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗