Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Yield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Angular momentum effects in fission

Background: The role of angular momentum in fission has long been discussed but the observable effects are difficult to quantify. Purpose: Here we discuss a variety of effects associated with angular momentum in fission and present quantitative illustrations. Methods: We employ the fission simulation model freya , which is well suited for this purpose because it obeys all conservation laws, including linear and angular momentum conservation at each step of the process. We first discuss the implementation of angular momentum in freya and then assess particular observables, including various correlated observables. We also study potential effects of neutron-induced fission of the low-lying isomeric state of U 235 relative to the ground state. Results: The fluctuations inherent in the fission process ensure that the spin of the initial compound nucleus has only a small influence on the fragment spins, which are therefore nearly uncorrelated. There is a marked correlation between the spin magnitude of the fission fragments and the photon multiplicity. We also consider the dynamical anisotropy caused by the rotation of an evaporating fragment and study especially the distribution of the projected neutron-neutron opening angles, showing that while it is dominated by the effect of the evaporation recoils, it is possible to extract the signal of the dynamical anisotropy by means of a Fourier decomposition. Finally, we note that the use of an isomeric target, U 235 m ( n th ,f), may enhance the symmetric yields and can thus result in higher neutron multiplicities for low total fragment kinetic energies. Conclusions: While the initial angular momentum of the fissioning nucleus tends to have little effect on the observables, those of the produced fragments influence the emitted neutrons and photons in a significant and correlated manner which may be exploited experimentally to elucidate the fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator light yield measurements with waveform digitizers

The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only proportional to the amount of scintillation light if the temporal shape of the scintillation pulse is independent of the amount of energy deposited. Finally, this is not the case for scintillation pulses resulting from fast neutron interactions in organic scintillators. Authors measuring proton light yield should therefore report pulse integral values and ensure that the integration length is long enough to capture most of the scintillation light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining Inputs to Realistic Kilonova Simulations through Comparison to Observed r -process Abundances

Kilonovae, one source of electromagnetic emission associated with neutron star mergers, are powered by the decay of radioactive isotopes in the neutron-rich merger ejecta. Models for kilonova emission consistent with the electromagnetic counterpart to GW170817 predict characteristic abundance patterns, determined by the relative balance of different types of material in the outflow. Assuming that the observed source is prototypical, this inferred abundance pattern in turn must match r -process abundances deduced by other means, such as what is observed in the solar system. We report on analysis comparing the input mass-weighted elemental compositions adopted in our radiative transfer simulations to the mass fractions of elements in the Sun, as a practical prototype for the potentially universal abundance signature from neutron star mergers. We characterize the extent to which our parameter inference results depend on our assumed composition for the dynamical and wind ejecta and examine how the new results compare to previous work. We find that a dynamical ejecta composition calculated using the FRDM2012 nuclear mass and FRLDM fission models with extremely neutron-rich ejecta ($Y_e$ = 0.035) along with moderately neutron-rich ($Y_e$ = 0.27) wind ejecta composition yields a wind-to-dynamical mass ratio of $M_w$/$M_d$ = 0.47, which best matches the observed AT2017gfo kilonova light curves while also producing the bestmatching abundance of neutron capture elements in the solar system, though, allowing for systematics, the ratio may be as high as of order unity.

79 ASTRONOMY AND ASTROPHYSICS↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

Neutron detection and application with a novel 3D-projection scintillator tracker in the future long-baseline neutrino oscillation experiments

Neutrino oscillation experiments require a precise measurement of the neutrino energy. However, the kinematic detection of the final-state neutron in the neutrino interaction is missing in current neutrino oscillation experiments. The missing neutron kinematic detection results in a smaller detected neutrino energy than the true neutrino energy. A novel 3D-projection scintillator tracker, which consists of roughly ten million active cubes covered with an optical reflector, is capable of measuring the neutron kinetic energy and direction on an event-by-event basis using the time-of-flight technique thanks to the fast timing, fine granularity, and high light yield. The $\overline{v}$ μ interactions tend to produce neutrons in the final state. By measuring the neutron kinetic energy, the $\overline{v}$ μ energy can be reconstructed better, allowing a tighter incoming neutrino flux constraint. This article shows the detector's ability to reconstruct neutron kinetic energy and the $\overline{v}$ μ flux constraint achieved by selecting the charged-current interactions without mesons or protons in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstructing Masses of Merging Neutron Stars from Stellar r -process Abundance Signatures

We report that neutron star mergers (NSMs) are promising astrophysical sites for the rapid neutron-capture ("r") process, but can their integrated yields explain the majority of heavy-element material in the Galaxy? One method to address this question implements a forward approach that propagates NSM rates and yields along with stellar formation rates and compares those results with observed chemical abundances of r-process-rich, metal-poor stars. In this work, we take the inverse approach by utilizing r-process-element abundance ratios of metal-poor stars as input to reconstruct the properties -especially the masses - of their neutron star (NS) binary progenitors. This novel analysis provides an independent avenue for studying the population of the original NS binary systems that merged and produced the r-process material now incorporated in Galactic metal-poor halo stars. We use ratios of elements typically associated with the limited-r-process and the actinide region to those in the lanthanide region (i.e., Zr/Dy and Th/Dy) to probe the NS masses of the progenitor merger. We find that NSMs can account for all r-process material in metal-poor stars that display r-process signatures, while simultaneously reproducing the present-day distribution of double-NS systems. Notably, with our model assumptions and the studied stellar sample, we postulate that the most r-process enhanced stars (the r–II stars) on their own would require progenitor NSMs of asymmetric systems that are distinctly different from present ones in the Galaxy. We also explore variations to the model and find that the predicted degree of asymmetry is most sensitive to the electron fraction of the remnant disk wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron correlation effects on exchange interactions and spin excitations in 2D van der Waals materials

Despite serious effort, the nature of the magnetic interactions and the role of electron-correlation effects in magnetic two-dimensional (2D) van der Waals materials remains elusive. Using CrI 3 as a model system, we show that the calculated electronic structure including nonlocal electron correlations yields spin excitations consistent with inelastic neutron-scattering measurements. Remarkably, this approach identifies an unreported correlation-enhanced interlayer super-superexchange, which rotates the magnon Dirac lines off, and introduces a gap along the high-symmetry Γ-K-M path. This discovery provides a different perspective on the gap-opening mechanism observed in CrI 3 , which was previously associated with spin–orbit coupling through the Dzyaloshinskii–Moriya interaction or Kitaev interaction. Our observation elucidates the critical role of electron correlations on the spin ordering and spin dynamics in magnetic van der Waals materials and demonstrates the necessity of explicit treatment of electron correlations in the broad family of 2D magnetic materials.

36 MATERIALS SCIENCE↗

Isotopic equilibrium constants for very low-density and low-temperature nuclear matter

Yields of equatorially emitted light isotopes, 1 ≤ Z ≤ 14, observed in ternary fission in the reaction 241 Pu(n th, f) are employed to determine apparent chemical equilibrium constants for low-temperature and low-density nuclear matter. The degree of equilibration and role of medium modifications are probed through a comparison of experimentally derived reaction quotients with equilibrium constants calculated using a relativistic mean-field model employing a universal medium modification correction for the attractive σ meson coupling. The results of these comparisons indicate that equilibrium is achieved for the lighter ternary fission isotopes. For the heavier isotopes experimental reaction quotients are well below calculated equilibrium constants. This is attributed to a dynamical limitation reflecting insufficient time for full equilibrium to develop. The role of medium effects leading to yield reductions is discussed as is the apparent enhancement of yields for 8 He and other very neutron rich exotic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension of SCALE/Sampler’s sensitivity index for the assessment of cross section, fission yield, and decay data uncertainties

Accurate prediction of nuclide compositions and neutron and gamma sources and spectra for fresh and spent nuclear fuel through computational modeling and simulations is the basis for safeguards instruments design, optimization, and calibration, and for validation of the measured responses. The accuracy of these simulations can be significantly impacted by uncertainties in input parameters to the applied computer code. Input parameters are, for example, dimensions, material compositions, and temperatures of the model. Additionally, important but sometimes neglected input parameters for simulations of nuclear systems are the nuclear data that include nuclear reaction cross sections, fission product yields, and decay data. It has been shown that uncertainties of calculated results are dominated by uncertainties of these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Yield nTOF Spec A and NP Filter Holders Static and Seismic Analysis

The Neutron Time-of-Flight (nTOF) detectors located in the Alcove and at the North Pole (Spec A and Spec NP respectively) need filtering in the beam path to enable them to take data at NIF yields above 5MJ. The filtering consists of 12cm of filter material divided into four, 3cm thick “pucks.” The pucks are 7cm in diameter. Each puck is mounted into a rotatable stage, also called a Filter Flipper, that can bring it into and out of the beam path, see Figure 1-1. These stages are bolted onto a plate that connects the filter stages to the mounting hardware used to position them in the NIF Target Bay. The top-level filter mount assemblies will be permanently mounted in the facility; removal is possible if needed for NIF maintenance, but the design intent is for the assemblies to remain in their locations after alignment is completed.

42 ENGINEERING↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Investigating the weak charge of 48 Ca using a dispersive optical model

A new nonlocal dispersive-optical-model analysis has been carried out for neutrons and protons in 48 Ca that reproduces the weak-form-factor measurement of CREX. In addition to elastic-scattering angular distributions, total and reaction cross sections, single-particle energies, the neutron and proton numbers, and the charge distribution, the CREX-measured weak form factor has been fit to extract the neutron and proton self-energies both above and below the Fermi energy. The resulting single-particle propagators yield a weak form factor of F w = 0.125 ± 0.05 and a neutron skin of R skin = 0.152 ± 0.05 fm, in good agreement with CREX. The rearrangement of the neutron distribution to accommodate such a thin neutron skin results in the high-momentum content of the neutrons exceeding that of the protons, in contrast to what is expected from high-energy two-nucleon knockout measurements by the CLAS collaboration and ab initio asymmetric matter calculations. The present analysis also emphasizes the importance of neutron experimental data in constraining weak charge observables necessary for a precise description of neutron densities. Notably, the neutron reaction cross section and further parity-violating experiments weak form factor measurements are essential to generate a unique way to determine the 48 Ca neutron distribution in this framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

High-repetition-rate, multi-MeV deuteron acceleration from converging heavy water microjets at laser intensities of 10 21 W/cm 2

Herein we demonstrate high repetition-rate deuteron acceleration by irradiating a continuously flowing, ambient temperature liquid heavy water jet with the high-intensity ALEPH laser. The laser delivered up to 5.5 J (120 TW, 1.2 × 10 21 W/cm 2 ) laser energy on target at 0.5 Hz. A high repetition-rate Thomson parabola spectrometer measured the deuteron beam energy spectra on each shot for 60 sequential shots (two minutes). Peak fluxes of 5 x 10 10 deuterons/sr/pulse, corresponding to an average flux of 1.5 x 10 12 deuterons/sr/min, were demonstrated with deuteron energies reaching up to 4.4 MeV. High shot-to-shot stability is observed up to 40%–50% of the maximum deuteron energy. These deuteron beams are suited for fast neutron production through deuteron breakup in a converter yielding energies similar to deuteron–deuteron (D–D, 2.45 MeV) fusion reactions of importance for material damage studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗